Connect-per-request with the TCP cold-boot retry kept; a different unit answering is refused (409) whenever the serial is already in hand. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
122 lines
5.2 KiB
Python
122 lines
5.2 KiB
Python
"""Series-3 adapter. Connect-per-request, as SFM has always done for
|
|
MiniMates -- a held session waits for the bench test in the spec."""
|
|
from __future__ import annotations
|
|
|
|
import logging
|
|
from typing import Any, Callable
|
|
|
|
from minimateplus import MiniMateClient
|
|
from minimateplus.transport import TcpTransport
|
|
|
|
from .errors import DeviceError, MalformedReply, NoAnswer, WrongUnit, translate
|
|
from .models import UnitAddress, UnitInfo, UnitSettings, UnitStatus
|
|
|
|
log = logging.getLogger("sfm.device_access")
|
|
|
|
S3_DEFAULT_BAUD = 38400
|
|
S3_MODES = {0x00: "Single Shot", 0x01: "Continuous", 0x03: "Histogram", 0x04: "Histogram + Continuous"}
|
|
|
|
|
|
def default_s3_client_factory(address: UnitAddress, timeout: float = 10.0) -> MiniMateClient:
|
|
if address.host:
|
|
return MiniMateClient(transport=TcpTransport(address.host, port=address.tcp_port), timeout=timeout)
|
|
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD)
|
|
|
|
|
|
def _close(client: Any) -> None:
|
|
try:
|
|
client.close()
|
|
except Exception: # noqa: BLE001
|
|
log.debug("close failed", exc_info=True)
|
|
|
|
|
|
class Series3Adapter:
|
|
def __init__(self, client_factory: Callable[[UnitAddress], Any] = default_s3_client_factory) -> None:
|
|
self._factory = client_factory
|
|
|
|
def _run(self, address: UnitAddress, fn: Callable[[Any], Any]) -> Any:
|
|
def attempt() -> Any:
|
|
client = self._factory(address)
|
|
try:
|
|
client.open()
|
|
except Exception as exc:
|
|
_close(client)
|
|
raise translate(exc, connecting=True) from exc
|
|
try:
|
|
return fn(client)
|
|
except DeviceError:
|
|
raise
|
|
except Exception as exc:
|
|
raise translate(exc, connecting=False) from exc
|
|
finally:
|
|
_close(client)
|
|
|
|
try:
|
|
return attempt()
|
|
except NoAnswer:
|
|
# A MiniMate that has just had its serial lines asserted can take
|
|
# 5-10 s to boot, and shows it as silence; one retry covers it. TCP
|
|
# only -- on a serial cable a silence is a real fault. Narrower than
|
|
# server._run_with_retry (any protocol error): retrying a
|
|
# MalformedReply would also retry "no settings block", which a
|
|
# reconnect cannot fix.
|
|
if not address.host:
|
|
raise
|
|
log.info("Series 3 at %s: no clean answer, retrying once (unit may be cold)", address.key)
|
|
return attempt()
|
|
|
|
@staticmethod
|
|
def _check(serial_reported: str, serial: str, address: UnitAddress) -> None:
|
|
if (serial_reported or "").strip().upper() != serial:
|
|
raise WrongUnit(f"asked for {serial} but {serial_reported} answered at {address.key}")
|
|
|
|
def identify(self, address: UnitAddress, serial: str) -> UnitInfo:
|
|
def op(client: Any) -> UnitInfo:
|
|
info = client.connect()
|
|
self._check(info.serial, serial, address)
|
|
cc = info.compliance_config
|
|
return UnitInfo(
|
|
serial=info.serial, series=3, model=info.model, firmware=info.firmware_version,
|
|
monitoring=None, active_setup=cc.setup_name if cc else None,
|
|
detail={"manufacturer": info.manufacturer, "dsp_version": info.dsp_version},
|
|
)
|
|
return self._run(address, op)
|
|
|
|
def status(self, address: UnitAddress, serial: str) -> UnitStatus:
|
|
def op(client: Any) -> UnitStatus:
|
|
client.poll()
|
|
ms = client.get_monitor_status()
|
|
return UnitStatus(
|
|
serial=serial, series=3, monitoring=ms.is_monitoring,
|
|
battery_volts=round(ms.battery_v, 2) if ms.battery_v is not None else None,
|
|
memory_total_bytes=ms.memory_total, memory_free_bytes=ms.memory_free,
|
|
device_time=None, event_count=None,
|
|
)
|
|
return self._run(address, op)
|
|
|
|
def settings(self, address: UnitAddress, serial: str) -> UnitSettings:
|
|
def op(client: Any) -> UnitSettings:
|
|
info = client.connect()
|
|
self._check(info.serial, serial, address)
|
|
cc = info.compliance_config
|
|
if cc is None:
|
|
raise MalformedReply("could not read the unit's settings (SUB 0x1A)")
|
|
mode = None
|
|
if cc.recording_mode is not None:
|
|
mode = S3_MODES.get(cc.recording_mode, f"unknown (0x{cc.recording_mode:02x})")
|
|
notes = {
|
|
label: value for label, value in (
|
|
("Project", cc.project), ("Client", cc.client), ("User Name", cc.operator),
|
|
("Seis Loc", cc.sensor_location), ("Extended Notes", cc.notes),
|
|
) if value is not None
|
|
}
|
|
return UnitSettings(
|
|
serial=info.serial, series=3, setup_name=cc.setup_name, record_mode=mode,
|
|
sample_rate=cc.sample_rate, record_time_s=cc.record_time,
|
|
histogram_interval_s=cc.histogram_interval_sec, geo_trigger_ips=cc.trigger_level_geo,
|
|
notes=notes,
|
|
detail={"record_mode_code": cc.recording_mode, "alarm_level_geo": cc.alarm_level_geo,
|
|
"geo_range": cc.geo_range},
|
|
)
|
|
return self._run(address, op)
|