Files
seismo-relay/sfm/device_access/errors.py
T
serversdownandClaude Opus 5.5 8f68b09f5e fix(sfm): a change that fails after the send says so; the audit row records sent + states; S3 unknown states refused
Final fix wave for phase 3 (start/stop monitoring), per the whole-phase review.

- I1 + M2: every failure after the send has started is a ChangeUnconfirmed
  (audit_id, sent = "acknowledged" | "unknown", the cause's HTTP status) whose
  message says the frame was sent and names the audit record -- the ring in
  place of the ack, the four lost-ack follow-ups, and the three read-back
  paths.  Series4Session releases the line on it.  Every audit finish goes
  through one helper; a finish that fails is AuditIncomplete (500) and still
  says what happened to the unit.  The line is kept.
- I2: device_commands gains `sent` (1 acknowledged, 0 nothing sent, NULL
  unknown) and `states` (before / seen / after), with an idempotent ADD COLUMN
  in _migrate for a table created earlier on this branch.
- M1: a RADIO RING already buffered is caught before 0x96/0x97 goes out
  (pre_send = read_unsolicited, one 10 ms transport read).  That is a
  CallHomeInProgress with sent=0, not ChangeUnconfirmed.
- M3: Series 3 reads the raw 0x1C flag (new MonitorStatus.state_flag); a byte
  other than 0x00/0x10, or a short section, is unknown(...) and refused.
- M8: even_if_already on a unit already in the state notes that the read-back
  proves nothing.
- M10: a scan pins `.protocol.execute(` to sfm/device_access/s4.py; both
  scans fail closed on a file that does not parse.
- M11: docs corrected (CLAUDE.md phase-2 sentence, phase-3 bullet, REST list;
  micromate/protocol.py scope and the 0x49 read_state docstring; s4.py; route
  docstrings).  "No command has ever been originated" is NOT retracted.
- M12: GET /db/device_commands normalises the serial.
- Minors: unused imports, S3 dry-run frames and 120 s timeout pinned, test
  rename, serial-cache and short-0x49 tests, _RUN_STATES comment.

Schema: two NULLable columns on the branch-new device_commands table, added
by _migrate on open; no backfill.  No codec change, TOOL_VERSION unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 19:16:45 -04:00

109 lines
3.0 KiB
Python

"""Typed device errors, each with the HTTP status the endpoints return."""
from __future__ import annotations
import micromate.protocol as _mm_proto
import minimateplus.protocol as _mmp_proto
class DeviceError(Exception):
http_status = 500
class BadRequest(DeviceError):
http_status = 422
class NotSupported(DeviceError):
http_status = 501
class WrongUnit(DeviceError):
http_status = 409
class UnitStateUnknown(DeviceError):
"""The unit reports a run state that has never been measured."""
http_status = 409
class AuditUnavailable(DeviceError):
"""The audit row could not be written, so nothing was sent."""
http_status = 503
class AuditIncomplete(DeviceError):
"""The unit was dealt with, but its audit row could not be finished. The
message says what happened to the unit first, then names the row."""
http_status = 500
class ChangeUnconfirmed(DeviceError):
"""A change failed after its frame went out, or may have gone out.
`sent` is "acknowledged" (the ack came back; the read-back failed) or
"unknown" (the ack was lost, or a call-home took its place). The status is
the one the cause would have had, set per instance, and the message names
the audit record. It never means "nothing was sent".
"""
http_status = 500
def __init__(self, message: str, *, audit_id: str, sent: str, http_status: int) -> None:
if sent not in ("acknowledged", "unknown"):
raise ValueError(f"sent must be 'acknowledged' or 'unknown', not {sent!r}")
super().__init__(message)
self.audit_id = audit_id
self.sent = sent
self.http_status = http_status
class UnitBusy(DeviceError):
http_status = 423
class ConnectFailed(DeviceError):
http_status = 503
class CallHomeInProgress(DeviceError):
http_status = 503
class NoAnswer(DeviceError):
http_status = 504
class MalformedReply(DeviceError):
http_status = 502
class EventNotFound(DeviceError):
http_status = 404
class StaleEvent(DeviceError):
"""The event at that key is not the one listed -- the unit was erased, or
its memory wrapped, since the list was read."""
http_status = 409
_TIMEOUTS = (_mm_proto.TimeoutError, _mmp_proto.TimeoutError)
_PROTOCOL = (_mm_proto.ProtocolError, _mmp_proto.ProtocolError)
def translate(exc: BaseException, *, connecting: bool) -> DeviceError:
"""Map a library exception to a typed error.
Order matters: each library's TimeoutError is a ProtocolError subclass, and
the builtin TimeoutError (a failed TCP connect) is an OSError.
"""
if isinstance(exc, DeviceError):
return exc
if isinstance(exc, _TIMEOUTS):
return NoAnswer(f"the unit did not answer: {exc}")
if isinstance(exc, _PROTOCOL):
return MalformedReply(f"bad reply from the unit: {exc}")
if isinstance(exc, OSError):
what = "could not connect" if connecting else "connection lost"
return ConnectFailed(f"{what}: {exc}")
return DeviceError(f"device error: {exc}")