Files
seismo-relay/docs
serversdownandClaude Opus 5 90ac7ff76a docs(series4): SOLVED -- call-home is an in-band wake signal, not a dial-out
From THOR's own ACH log, 4,414 lines, UM12947 over an RX55.  This overturns the
model this document has carried from the start and explains every confusing
result of the past weeks.

A MICROMATE DOES NOT DIAL ANYBODY.  It emits the ASCII string "RADIO RING" over
its serial port, and that text travels up a TCP connection THE SERVER ALREADY HAS
OPEN TO THE UNIT.  The server recognises it and runs a session on that same
connection.

  17:18:17  TcpClientSystemNet    #1: RADIO RING IS RECEIVED FROM IP:63.45.161.30 Port:9034
  17:18:17  ListenerAchRadioRing  #2 RADIO RING IS DETECTED
  17:18:17  ConnectorWorkerThread Process Request: ReadSerialNumber
  17:18:18  ListenerAchRadioRing  #3 RADIO RING UNIT SERIAL NUMBER = UM12947
  17:18:18  ACHManager            #8 RADIO RING STARTED A NEW SESSION

TcpClientSystemNet is THOR's outbound TCP CLIENT -- the ring arrives on the
connection THOR itself opened to unit:9034, the ordinary call-UP path.  No
inbound connection, no dial, nothing to accept.  THOR keeps that connection alive
on purpose: UnitWatchDogTimer reconnects continuously, 1,039 log lines in 37
minutes.

THOR's OTHER ACH path was never used.  ListenerAchTcp logs "Waiting for a ACH
connection on Port 12346" and in 4,414 lines NEVER ACCEPTED ONE.  All twelve ACH
events came through ListenerAchRadioRing.

CONSEQUENCE: bridges/mm_ach_server.py is built on the wrong model for this
deployment.  It listens for an inbound connection -- ListenerAchTcp's model, the
one THOR never exercises here.  The right shape is a POLLER that holds an
outbound connection to each unit, watches the stream for RADIO RING, identifies
the unit, and runs a session on the same socket.

That also dissolves the single-session contention that dogged every experiment
today: the receiver must hold the modem's one session slot PERMANENTLY.  Our
probes and MITM attempts were not fighting a bug, they were fighting the design.

Also captured: the full ACH state machine (15 steps), the eight request types
with counts, and two corroborations -- StartMonitoringAfterCallhome matches the
firmware string found by static analysis in September, and ReadEventRecordCount
returning "Event count: 19" independently supports the SUB 0x06 event-count
finding.

Flagged, unexplained: events are addressed as 90000001 (length 4076) in THOR's
ACH path, where our chain walk returns 055d4a81 for an event of exactly that
length.  Same event, different address space.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-14 17:55:50 -04:00
..
2026-02-24 21:19:40 +00:00