Settled by a clean experiment. The call-modem setting was changed on the keypad from 'generic' to 'USB to PC', then the ACTIVE SETUP was switched from TEST1 to test2 on the device. The setting did not change. So it is device-global, in the SysParm.cfg the firmware strings already hinted at alongside SysPref.bMonitorScheduler -- not a per-setup field. That closes a hypothesis this document was chasing: the ~102 bytes a .MMB file carries beyond the 2,090-byte config block are NOT where this lives. Those bytes remain unexplained but are no longer a candidate. CORRECTS an over-reading in an earlier commit. "The call-home block (0x2C) was byte-identical across 218 samples today" does not bear on this question: the last 0x2C sample was at 13:30:23 and the keypad change came around 13:35, so no sample exists on the far side of it. Why the split is right, and the operator's reading of it: you do not want modem settings reachable remotely, because getting them wrong over the air destroys the connection you would need to put them back, and the unit must then be visited. So SUB 0x2C is not an incomplete view of the modem configuration -- it is the deliberately-chosen subset that is SAFE to change remotely (enable, dial string, retries, timings), and the unreachable remainder is unreachable on purpose. Records the design principle for SFM: for settings whose misconfiguration destroys the channel you would use to fix them, either do not expose them for remote write, or require commit/confirm with automatic rollback (apply, require a call-back within N minutes, revert otherwise). Always allow READING them, so an operator can diagnose a unit they cannot reconfigure. Instantel chose the first option and given the failure mode that is worth copying rather than improving on. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
107 KiB
Micromate Protocol Reference — Thor / Micromate Series IV, live wire protocol
Sibling to instantel_protocol_reference.md
(Series III, "the Rosetta Stone") and
idf_protocol_reference.md (Series IV file
format). This document covers the Series IV live device protocol — what
the unit says over the wire, as opposed to what it writes into a .IDFW.
Status (2026-09-23): opening session. Everything below was established in a single bench session against one unit. Treat it as a strong start, not a settled spec — in particular, everything here comes from one unit, over USB, with no events stored.
The headline
A Micromate running the Blastware firmware answers Series III command frames.
An unmodified Series III POLL (SUB 0x5B), built by
minimateplus.framing.build_bw_frame with no changes at all, produced a
complete two-step probe/data cycle. Ten Series III read commands were then
tried and all ten answered, every one obeying the Series III response-SUB
rule.
⚠ That qualifier is load-bearing, and it was discovered after the fact. Instantel ships the Micromate in two firmware lines:
| firmware | Instantel's own description |
|---|---|
11.0CB |
"Utilize with Blastware" |
11.0BD |
"Utilize with THOR, Vision, Vision II" |
The bench unit reports 11.0CB — the Blastware build. So the clean
Series III behaviour above is very likely because the unit is in Blastware
mode, not because the Micromate natively speaks Series III. Nothing here
should be assumed to hold on a 11.0BD unit until tested.
This reframes the project. The question is no longer only "what is the Series IV protocol" but "which firmware line do we target, and does one of them let the existing Series III stack drive the whole fleet?"
Firmware — the variable nobody knew was a variable
This explains a production problem TMI has lived with: two ACH servers, two machines, and units that will not cross over. It is not a misconfiguration. Instantel ships different firmware for different host software, and the wire protocol differs with it.
Fleet audit (physical, 2026-09-22/23)
| unit | firmware | line | location |
|---|---|---|---|
| UM11719 | 11.0CB |
Blastware | Ped Bridge Loc 2 |
| UM6047 | 11.0CB |
Blastware | Brookville Loc 9 |
| UM12947 | 11.0CB |
Blastware | bench |
| UM14133 | 11.0CB |
Blastware | Pitt-Music Bldg Loc 1 |
| UM11402 | 11.0BD |
Thor | Ped Bridge Loc 1 |
| UM20147 | 11.0BD |
Thor | bench |
| UM13981 | 11.0AK |
pre-split | RKM Loc 1 |
| UM20146 | 11.0AK |
pre-split | Karns Loc 2 |
| UM12420 | 10.90GC |
pre-split | RKM Loc 2 |
4 Blastware / 2 Thor / 3 pre-split. The Blastware line is already the plurality, which makes "standardise on Blastware" less disruptive than it first appeared.
A store-derived audit (firmware is recorded in every .sfm.json sidecar as
extensions.idf_report.version) agreed with the physical audit on 7 of 9.
The two that differed — UM6047 and UM14133 — are the most recently deployed
units, reflashed after their last stored event. Useful technique: the fleet's
firmware history is reconstructable from the store without touching a unit,
but it lags reality by one deployment.
Firmware is not stable per-unit over time — five of nine have been reflashed at least once. Any fleet-wide claim needs a fresh audit.
⚠ Retraction: firmware line does NOT determine Thor compatibility
An earlier draft of this document suggested that UM12947's trouble with Thor was explained by its being on the Blastware build. That is not supported.
Ped Bridge runs UM11402 (11.0BD) and UM11719 (11.0CB) side by side, both
deployed 2026-04-20, and both call Thor successfully — UM11719 has 331
Thor-collected events in the store while on 11.0CB, through 2026-08-23.
So a Blastware-line unit does feed Thor. Whatever the CB/BD split changes, it is not "which host software can collect from it", and UM12947's specific problem remains unexplained.
What is actually established: a 11.0CB unit answers Series III command
frames. Whether a 11.0BD unit does is untested — and UM20147 (11.0BD)
is on the bench, which makes that a direct A/B away.
The version is readable over the wire from SUB 0x01 as two separate ASCII
runs — "0CB" then "11" — with no single concatenated string.
The strategic fork
- Option A — standardise the fleet on the Blastware line. Every unit,
MiniMate and Micromate alike, then speaks Series III, and the existing
minimateplus/stack drives all of it. One protocol, one call-home receiver. Dramatically cheaper if it holds up. - Option B — reverse-engineer the Thor line (
11.0BD) and support both.
Option A is the shortcut, but it is unproven and carries real unknowns, all of which are cheap to answer on the bench and expensive to discover later:
- What file format does a
11.0CBunit produce? If it emits Blastware binaries rather than.IDFW/.IDFH, the (now exact) Series III decoder applies and the IDF codec becomes a legacy path. Not a loss — we have both — but it changes what the ingest pipeline sees. - Does Thor still work with a
11.0CBunit? If not, flashing a production unit breaks data collection until the replacement path exists. - Are any Micromate-specific capabilities lost on the Blastware line?
- Is the flash reversible in the field, and what does it cost in downtime?
How this was obtained
No Thor, no modem, no Windows machine. The Micromate exposes its protocol on a USB CDC-ACM virtual serial port:
ID 2504:0300 Instantel Inc. MICROMATE COM PORT
driver: cdc_acm ATTRS{serial}=="V1.00"
→ /dev/ttyACM0
Plain CDC ACM, so no vendor driver and no proprietary USB layer — any host that can open a serial port can talk to the unit.
Baud is irrelevant over USB. Identical byte-for-byte responses at 38400 and 115200; CDC-ACM ignores the line rate. TMI provisions Micromate modem links at 115200 (Series III uses 38400) — that matters for the cellular path, not for USB.
The device never speaks first. 20 s of passive listening on an idle open port produced zero bytes. It is strictly request/response.
Physical + framing layer
Requests — Series III format, unmodified
Every frame in this session was produced by build_bw_frame(sub, offset) with
no Series IV changes, and the device accepted all of them:
[ACK 0x41] [STX 0x02] [10 10] [flags 00] [SUB] [00] [00] [offset] [params×10] [chk] [ETX 0x03]
⚠ Only the doubled BW_CMD (10 10) form has been exercised. Whether other
literal 0x10 bytes inside params require stuffing is untested — none of
the probes sent carried one.
Responses — Series III minus the DLE prefix
Series III: [DLE 0x10] [STX 0x02] … [chk] [ETX 0x03]
Micromate: [STX 0x02] … [chk] [ETX 0x03] ← no leading DLE
This single byte matters operationally: Blastware's parser locates frames by
scanning for DLE+STX, so it will never find a frame boundary in Micromate
traffic no matter what else is correct. That is a structural reason a
Micromate cannot call into a Blastware ACH server, independent of any baud
mismatch.
Response payload header
[0] CMD 0x00 same as Series III
[1] flags 0xC5 ← Series III uses 0x10. Constant across all 10 SUBs.
[2] SUB 0xFF − request_SUB
[3] PAGE_HI
[4] PAGE_LO
[5+] data
Checksum — the DLE-aware variant
chk = sum(b for b in payload if b != 0x10) & 0xFF
Confirmed on every frame captured. The POLL probe response contains no
0x10 and so cannot distinguish plain SUM8 from the DLE-aware form; the
POLL data response contains a 0x10 at payload offset 42, and only the
DLE-aware rule matches there. This is the same checksum Series III uses for
its 5A bulk-stream and write frames — not the plain SUM8 of ordinary
Series III reads.
The probe response carries the data length
Series III hardcodes DATA_LENGTHS per SUB. On the Micromate the probe
response tells you, as a uint16 BE at payload[8:10]:
⚠ Corrected 2026-09-23. An earlier draft read this as a single byte at
payload[9]. That is right only while the high byte is zero, and it is
catastrophically wrong for SUB 0x1A, whose real length is 0x082C = 2092
— read as a byte it gives 44, a 47× under-read. Always read the pair.
| SUB | command | payload[9] |
Series III constant |
|---|---|---|---|
0x15 |
serial number | 0x0A |
0x0A ✓ |
0x01 |
device info | 0x98 |
0x98 ✓ |
0x1C |
monitor status | 0x2C |
0x2C ✓ |
0x06 |
storage range | 0x24 |
0x24 ✓ |
0x2C |
call-home config | 0x7E |
0x7C ✗ differs by 2 |
0x08 |
event index | 0x5A |
— |
0x1E |
event header | 0x08 |
— |
0x1A |
compliance config | 0x082C (2092) |
— |
0x0A |
waveform header | 0x00 |
— (no event context) |
0xFE |
full config | 0x00 |
— (see note) |
Four of four known Series III lengths match exactly. Read the length from the probe rather than hardcoding it — it is free, and it already caught the call-home divergence.
Confirmed commands (read-only)
All ten below answered with a correct 0xFF − SUB response. Nothing that
writes, erases, or changes monitoring state has been sent to a unit.
| SUB | RSP | Command | Data proven |
|---|---|---|---|
0x5B |
0xA4 |
POLL / handshake | yes — ID block |
0x15 |
0xEA |
Serial number | yes — UM12947 |
0x01 |
0xFE |
Device info | yes — 152 B |
0x2C |
0xD3 |
Call-home config | yes — 126 B |
0x1C |
0xE3 |
Monitor status | yes — 44 B |
0x06 |
0xF9 |
Event storage range | yes — 36 B |
0x08 |
0xF7 |
Event index | probe only |
0x1E |
0xE1 |
Event header / first key | probe only |
0x0A |
0xF5 |
Waveform header | probe only |
0x1A |
0xE5 |
Compliance config | probe only |
Decoded so far
SUB 0x15 — serial. ASCII, null-terminated: UM12947.
SUB 0x5B / 0x01 — identification strings.
Instantel\0 and MM/ISEE/S/IO (MicroMate / ISEE standard). 0x01 also
carries eight consecutive 3f 80 00 00 float32 values (= 1.0f) — almost
certainly per-channel calibration/scale factors, by analogy with Series III's
geo_hardware_constant. Unverified.
SUB 0x1C — monitor status. Series III field offsets apply unchanged:
| field | offset | read |
|---|---|---|
| battery × 100 | payload[-10:-8] uint16 BE |
0x017D → 3.81 V |
| memory total | payload[-8:-4] uint32 BE |
15,000,000 |
| memory free | payload[-4:] uint32 BE |
15,000,000 (empty) |
| date | payload[18:22] |
day 23, month 9, year 0x07EA = 2026 |
The battery reading independently corroborates: Thor's own event reports for
these units print BatteryLevel : 3.8 volts.
SUB 0x2C — call-home config. Contains the ASCII string RADIO RING.
Worth flagging: that is the exact string seen in the RV50 ALEOS_SERIAL
debug during the BE12599 incident —
'ATQ1^MATE0^MATS0=2^M^MRADIO RING^M'. So this block holds the modem dial /
answer strings, and it is the most directly relevant command to the
call-home-receiver goal. Field layout not yet mapped; Series III's map
(raw[5] enabled, raw[6:46] dial string) is a starting hypothesis only, and
the length already differs (0x7E vs 0x7C).
SUB 0x06 — storage range. All zeros on this unit, consistent with
memory free == memory total. Series III reads first/last event keys from
the final 8 bytes; untestable until the unit holds events.
The event chain — walked end to end (2026-09-23, 5 events)
With 5 events on the bench unit (4 waveform + 1 histogram), the Series III browse walk works unmodified:
1E (all-zero params) -> first key + size
0A (key) -> partial record, histogram only
0C (key) -> 210-byte waveform record
1F (all-zero params/browse) -> next key + size
... repeat ...
1F -> all-zero key = NULL SENTINEL, chain ends
The sentinel terminated correctly after exactly 5 events.
Event keys are sequential, not addresses
055d4a81 055d4a82 055d4a83 055d4a84 055d4a85
This is a real divergence. Series III keys are flash-buffer addresses
(01110000, 011121F2, …) that advance by the event's byte length, which is
why its 5A chunk walk is address-arithmetic. Micromate keys are a plain
incrementing counter. Any port of the Series III download walk must not
assume key arithmetic means anything.
The 4 bytes after the key are the event's size
1E/1F return [key 4B][size 4B]. Series III uses that slot as an offset
to the next key; here it is a byte count:
| key | size | kind |
|---|---|---|
055d4a81 |
4,076 | histogram |
055d4a82 |
11,032 | waveform |
055d4a83 |
11,502 | waveform |
055d4a84 |
13,424 | waveform |
055d4a85 |
8,746 | waveform |
Consistent with real file sizes (corpus .IDFH ≈ 3.7–25 KB, .IDFW ≈
8.6–15.8 KB), and the histogram is unmistakably the small one. ⚠ Inferred,
not proven: the sizes sum to 48,780 while monitor status reports 57,344 bytes
used, so ~8.5 KB of overhead is unaccounted for.
SUB 0x0C — waveform record, and it carries the job metadata
Length 0xD2 = 210 bytes — identical to Series III. Contents confirmed
across all 5 events:
- the event key, echoed
- date + time (
17 09 07 ea→ 23 Sep 2026, then10 21→ 16:33 — matching the actual bench recording time) - title note
"Location" - the project string —
"Univ of Pitt-1st Yr Housing-Loc1 Ruskin" - serial
"UM12947" - channel labels
Tran/Vert/Long/Mic— the same labels Series III uses, and the same label-relative float32 layout - per-event float32 peaks: 3.5152, 1.3720, 2.3542, 3.5152, 0.4227 in/s across the five events (varied deliberately during recording)
This closes the biggest open question for the call-home-receiver goal.
The job identity strings (project / client / operator / setup) that
today arrive only via Thor's .txt sidecar — and which no amount of sample
decoding can reconstruct — are available over the wire from 0x0C. A
direct-to-SFM event need not arrive with blank metadata.
SUB 0x0A — partial record, histogram only
0x0A returned len = 0x1E (30 B) for the histogram and len = 0x00 for all
four waveforms. The histogram payload carries two timestamps and the
ASCII string "\r Vert: 0.300 in/s" — structurally the Series III
monitor-log partial record (0x2C type), which likewise holds a start/stop
pair and a "Geo: <float> in/s" trigger string.
So on the Micromate the division of labour is: 0x0A describes interval-style
records, 0x0C describes triggered events. Series III uses 0x0A's
response length (0x46 vs 0x2C) to tell real events from boundaries;
that discriminator does not apply here.
DLE stuffing in responses — confirmed present
Earlier marked untested. The 0x0C timestamp field contains 10 10, which
destuffs to a single 0x10 and yields a sensible clock reading. Responses
are DLE-stuffed, so a parser must destuff before applying field offsets.
A/B: Blastware build vs Thor build (2026-09-23)
UM12947 (11.0CB) and UM20147 (11.0BD) were each put on the bench and given
the identical read-only sweep. Both answer Series III command frames.
UM12947 11.0CB |
UM20147 11.0BD |
|
|---|---|---|
| POLL answers | ✓ | ✓ |
| All 10 read SUBs answer | ✓ | ✓ |
response_SUB = 0xFF − req |
✓ | ✓ |
| DLE-aware checksum valid | ✓ | ✓ |
| Two-step probe/data read | ✓ | ✓ |
| ID string | MM/ISEE/S/IO |
MM/ISEE/S |
| flags byte | 0xC5 |
0x03 |
0x1C length |
0x2C |
0x30 |
The firmware line does not change the wire protocol. One protocol stack can drive the whole fleet regardless of which build a unit is on. This is the single most consequential finding so far: "standardise the fleet on one firmware" becomes an optional convenience rather than a prerequisite for building a call-home receiver.
The two differences that do exist
1. The flags byte identifies the build. Response payload[1] is 0xC5
on the Blastware line and 0x03 on the Thor line, constant across all ten
SUBs on both units. That makes firmware line detectable from any response,
without reading device info. ⚠ Two units, one each — treat as a strong
hypothesis, not a proven encoding.
Note 0x03 is ETX, so on Thor-line units it arrives DLE-escaped as 10 03.
A parser that fails to destuff will mis-locate every field by one byte on
exactly half your fleet.
2. SUB 0x1C (monitor status) is 4 bytes longer on the Thor line —
0x30 vs 0x2C — with four extra trailing bytes (0f a0 00 00, purpose
unknown).
⚠ This breaks relative-to-end parsing. Series III reads battery and
memory from the end of the 0x1C block ([-10:-8], [-8:-4], [-4:]).
Those offsets are correct on 11.0CB and wrong on 11.0BD — applying them
blindly to UM20147 yields a battery reading of 577.92 V. Parse forward
from the declared length instead of backward from the end.
With the offsets shifted by 4, UM20147 reads correctly: battery 3.81 V, memory 15,000,000 total and free (no events stored).
Divergences from Series III (running list)
- No
DLEprefix on responses — bareSTX. - Response flags byte is
0xC5, not0x10. - Call-home config is 126 bytes, not 124.
- Data lengths are discoverable from the probe response at
payload[9]. 4b. Event keys are a sequential counter, not flash addresses. 4c.1E/1Freturn the event size, where Series III returns an offset. 4d.0x0Avs0x0Csplit by record type, not by the0x46/0x2Clength discriminator Series III uses. 4e. Responsepayload[1](flags) encodes the firmware line —0xC5Blastware,0x03Thor — where Series III has a constant0x10. - Modem serial rate is 115200, not 38400 (per TMI provisioning practice; not independently verified here).
- Reads are single-step — Thor asks for
offset = 0xFFFFand gets the whole block; Series III always probes first. (2026-09-24) - Setup writes are preceded by
SUB 0xDA, which names the target.MMBfile. Series III has no equivalent — it has one config, not named files. - The compliance block is written in ONE
0x71frame, not Series III's three chunks. 0x69/0x74(waveform data write) are absent from a setup push.- Six channel blocks (
Tran/Vert/Long/Mic/LMic/SMic) on a 48-byte stride, against Series III's four. - The notes block is four fixed-width
[label:22][value:42]entries on a 64-byte stride, with different labels — not Series III'slabel: valuescan targets. - The geophone scale factor is
3.10308, exactly half Series III's6.206053, with an ADC of 10,000 counts per volt. - The monitoring flag is
0x0E, where Series III uses0x10— and it sits atSUB 0x1Cdata[12]. A second indicator lives atSUB 0x49data[11](0x02monitoring), which Series III has no equivalent of. - Setup files are enumerated with a
0x3F/0x40first/next walk. Series III has one config and nothing to enumerate. SUB 0x1Ccarries the device clock (day/month/year/h/m/s atdata[13:21]). Nothing else read so far reports the unit's own time.- Deletion is per-event (
0xA8+ a key, then0xAA), where Series III can only erase everything (0xA3/0xA2). SUB 0x93arms each event before1E/1F, replacing Series III's1E(token=0xFE)— no token, no params.- Event keys are a sequential counter (
055D4A81…86), not flash addresses. - The ACH enable is
0x05/0x04, not Series III's0x01/0x00— bit 0 is the flag, bit 2 is set in both states. - There is a generic file transfer addressed by full path —
0x94/0x48read,0x8D/0x8Ewrite. Series III has nothing comparable; its config is reachable only through dedicated commands. - The scheduler is a separate file,
\system\schedule\schedule.dat, and a schedule entry names a setup file to load.
The firmware images are unencrypted — and they document themselves
ref-stuff/micromate-firmware/MICROMATE(CB).BIN and MICROMATE(BD).BIN,
~2.77 MB each and within 192 bytes of one another.
- Entropy 6.08 bits/byte — neither encrypted nor compressed. Plain code and data.
- Header is a big-endian vector table, handlers at
0x4010_30xx. - ~16,700 extractable strings, including the developers' own debug
printfformat strings with function names intact.
This is a legitimate interoperability reference for hardware TMI owns, and it short-circuits work I had scoped as "only answerable from a live modem capture".
The call-home state machine, verbatim
ACH_NOT_STARTED → ACH_IDLE → ACH_INITIALIZING → ACH_CONNECTING
→ ACH_CONNECTED → ACH_TRANSFER_DATA
→ ACH_RETRY / ACH_QUITTING (also ACH_STARTED)
Supporting strings:
ACH: Entry StartCallHome()
ACH: CallHome_task ; CheckAliveTime CANCEL ; TimeBetweenRetries = %d
ACH: CallHome_task ; !ExpectedCommunicationsDetected() CANCEL ; TimeBetweenRetries = %d
ACH: CallHomeCommectionCompleteProcessing() ACH=%s EAMWC=%s
ACH: %s() three attempts and it's over
ACH: %s() Send CMD_START_MONITOR
ACH: %s() Send CMD_STOP_MONITOR
ACH: Start Ignore request, Call Home is in progress
What this tells us without a single captured packet:
- Retry limit is three — "three attempts and it's over".
ExpectedCommunicationsDetected()gates the session. If the host does not say something the unit recognises, the call is cancelled and rescheduled afterTimeBetweenRetries. A homebrew receiver must satisfy this check or units will retry forever — which is exactly the failure mode seen on BE12599.- The unit stops monitoring to call home and restarts afterwards
(
Send CMD_STOP_MONITOR/CMD_START_MONITOR). Relevant to any wedged-unit rescue: the monitoring state around a call is the device's own doing, not ours. - Calls are not re-entrant — "Call Home is in progress" is ignored.
Internal command table
CMD_CALLHOME, CMD_CALLHOME_CANCEL, CMD_CALLHOME_CONNECTION_CONFIRMED,
CMD_CALLHOME_CONNECTION_COMPLETE, CMD_CALLHOME_SET_SCHEDULE,
CMD_CALLHOME_CLEAR_SCHEDULE, CMD_STOP_CALLHOME_FILETRANSFER,
CMD_DUTYCYCLE_AUTOCALLHOME, CMD_PURGE_EVENT_FLASH.
CONNECTION_CONFIRMED as a distinct state from CONNECTION_COMPLETE implies
a handshake the host must complete before data flows — the concrete shape
of ExpectedCommunicationsDetected().
Event delivery — the mechanism, probably
All Events Uploaded
Mark/Unmark File Delete Marked Events Marked Events were Deleted
MONITOR::MESG PURGE_EVENT_FLASH BEGIN / END
A marking mechanism exists, alongside a distinct "all uploaded" terminal state. 🔶 Inferred: events are marked as transferred rather than deleted on send, and purging is a separate explicit act. If so, a receiver that fails to mark would see the same events re-offered every call — the question that gates a safe homebrew receiver. Not yet confirmed; needs either a live call-home capture or disassembly around these strings.
A full user manual is embedded
The firmware carries its own HTML help, which documents configuration we would otherwise have to infer:
- Modem mode:
Generic(through a modem) vsUSB to PC. - Modem baud: 9600 / 19200 / 38400 / 57600 / 115200 / 230400 — "must match the expected rate of the PC or modem". Confirms 115200 is a setting, not a fixed rate.
- Modem relay + warmup (0–300 s), auxiliary mode, warning/alarm hold.
- Record modes: Waveform, Waveform Manual, Histogram, Histogram-Combo; sample rates 1024 / 2048 / 4096.
- A scheduler downloaded from THOR that can start/stop monitoring, change
record mode, trigger a call home, or run a self check on a daily/weekly
schedule. Pairs with
CMD_CALLHOME_SET_SCHEDULE.
Still worth doing
Diffing the two images should isolate exactly what the CB/BD split changes —
we know the wire protocol is not it, and the flags byte (0xC5 vs 0x03)
gives a concrete anchor to search for.
SUB 0x5A — bulk download. It streams the .IDFW file verbatim.
The complete read path works with no Instantel software in the loop.
It needs no arming sequence
Series III ignores a 5A probe unless preceded by
1E → 0A → 1E(token 0xFE) → 0C → 1F(token 0xFE) → POLL × 3. The Micromate
answers a bare 5A request with nothing before it. That whole ritual is
gone.
The offset word is a LENGTH, not a position
This is the key divergence. Series III walks chunks by absolute flash
address, stepping 0x0200 per request. On the Micromate the offset word
requests how much to send:
offset_word = 0x1000 + 2 × pages pages = ceil(event_size / 512)
offset_word |
pages | destuffed file bytes |
|---|---|---|
0x1002 |
1 | 518 |
0x1004 |
2 | 1,030 |
0x1006 |
3 | 1,541 |
0x102C |
22 | 11,033 — the whole event |
event_size comes from the chain walk (the 4 bytes after the key in
1E/1F). One request returns the entire event; there is no chunk loop,
no STRT end-offset parsing, and no TERM frame. Over-requesting is safe —
0x1030 (24 pages) returned exactly the same bytes as 0x102C, so the device
caps at the real size.
Params are the Series III probe form: [0x00][key4][6 × 0x00].
The payload is the .IDFW file, byte for byte
[18-byte frame header] [ .IDFW file ] [chk] [ETX] ← raw wire
^ destuffed offset 16
The file begins 00 12 01 00 00 00 "Instantel\0" — _THOR_PREFIX +
_INSTANTEL_TAG from micromate/idf_file.py. The first 32 bytes are
identical to a production .IDFW pulled from the store.
⚠ Responses are DLE-stuffed. Destuff before locating the file, or the raw byte count overshoots (11,781 raw → 11,049 destuffed for an 11,032-byte event).
End-to-end proof
Event 055d4a82 downloaded over USB and fed straight to read_idf_file():
serial UM12947
timestamp 2026-09-23 16:33:19
samples Tran 3072 Vert 3072 Long 3072 MicL 3072
peaks Tran 0.2433 Vert 1.3706 Long 0.2672 in/s
All four channels equal length, and the timestamp matches the 0x0C record
for the same key. Independent cross-check: 0x0C reports a stored peak
of 1.3720 for this event; the decoded samples give 1.3706 — two
unrelated paths agreeing to 0.1%.
Consequence: no new codec work is needed. The bytes off the wire are the
same bytes thor-watcher forwards today, so /db/import/idf_file ingests a
directly-downloaded event unchanged. Everything the IDF decoder already does
per-sample-exact applies.
What a full read now looks like
1E → first key + size
0C(key) → project/client/operator, timestamp, peaks
5A(key, 0x1000+2×ceil(size/512)) → the whole .IDFW
1F → next key + size (until null sentinel)
Setups are FILES, not a config block
Series III has one compliance config you overwrite. Series IV keeps named setup files on an on-device filesystem, with a pointer to the current one. From the firmware:
csetup.MMB the current setup
factory.MMB Factory Default Setup File
callhome.MMB call-home config is a file too
"Current Setup File: " "Can Not Delete Active Setup File"
GetSelectedSetupFilePathName() CSelectSetupFiles CSaveSetupFile
Names are up to 20 characters and may contain spaces, hyphens, underscores. The unit's help text describes selecting, renaming and deleting them, and the event list records which setup file produced each event.
Filesystem primitives exist internally (NS_ReadFile_internal,
NS_WriteFile_internal, NS_SeekFile_internal).
⚠ RETRACTED 2026-09-24. This section originally concluded "no generic file-transfer command is exposed on the wire", reasoning from the absence of firmware strings. That was wrong.
SUB 0x94/0x48/0x8D/0x8Eare exactly that — a read/write file transfer addressed by full filesystem path — and they were caught in the open on the first capture that touched the scheduler. See The scheduler, and a generic file transfer below.The lesson is the usual one: absence of a firmware string is not absence of a command. The dispatch is a 68K jump table and the commands carry no strings of their own.
The setups half of the original claim survives: setups are not pushed as raw
.MMBblobs. They go through0xDA+ the ordinary config block.
SUB 0x1A reads the whole active setup — 2,092 bytes
Structurally close to Series III's ~2,126-byte compliance block, and it carries everything a setup consists of:
- the setup file name —
Univ of Pitt-1st Yr. Housing-Loc1 Ruskin.MMB - all four title note/value pairs —
Location,Client,Company,General Notes, with their strings - the sensor location string (
Loc 1) - per-channel labels and units:
Tran in./s.,Vert in./s.,Long in./s.,Mic psi (L),LMic psi (L),SMic (A)
Note LMic / SMic — linear and sound-level microphone variants that
Series III does not have.
This is the read half of setup management, and it means a setup can be round-tripped: read the active config, modify, write it back. ✅ The write half was observed on 2026-09-24 — see The write path below, which confirms the round-trip: the written block is the read block, 91% byte-identical.
The write path — observed end to end (2026-09-24)
⚠ We have still never sent a write command to a unit. Thor did every write
below; seismo_lab's TCP bridge sat between Thor and the unit and recorded both
directions. Capture: bridges/captures/be12599-diag/9-24-26 - micromate2/
(raw_bw_* = Thor, raw_s3_* = unit), UM12947 on the USB PC port, relayed
to TCP by socat on mint-mac. Operation: push a setup named TEST1.mmb.
All 12 device responses checksum-validate and every write is acked.
The sequence
Thor: 5B │ 41 │ 08 │ 2E │ 1A │ DA │ 68 → 73 │ 82 → 83 │ 71 → 72
unit: A4 │ BE │ F7 │ D1 │ E5 │ 25 │ 97 8C │ 7D 7C │ 8E 8D
└──────── reads ────────┘ └──────────── writes ────────────┘
Series III, for comparison: 68→73 │ 71×3→72 │ 82→83 │ 69→74→72.
Same write SUBs, and every response SUB matches the Series III table
exactly (68→97, 73→8C, 82→7D, 83→7C, 71→8E, 72→8D).
Three differences:
SUB 0xDAis new and comes first — see below.0x71is a single write, not three chunks. Series III splits the compliance block into 1027 + 1055 + remainder; the Micromate takes all 2,090 bytes in one frame.0x69/0x74(waveform data write) do not appear at all.
Every write ack is a 16-byte zero-data frame, same shape as Series III's.
Three new read commands
| SUB | rsp | payload | what it carries |
|---|---|---|---|
0x41 |
0xBE |
271 B | the active setup's file name, e.g. TEST1.mmb |
0x2E |
0xD1 |
44 B | trigger-config block; mirrors what 0x82 writes |
0xDA |
0x25 |
272 B (write) | declares the target setup file — see below |
SUB 0xDA — name the setup file you are about to write
Data is exactly 256 bytes: the file name, null-padded, nothing else.
54 45 53 54 31 2e 6d 6d 62 00 00 … "TEST1.mmb" + 247 × 0x00
This is the missing link in setups are files: Thor names the target file, then
writes the ordinary config block into it. The unit acks with 0x25 before any
config bytes are sent.
Note 0xDA takes a bare filename null-padded to 256 bytes. That is a
different mechanism from the path-addressed file transfer (0x94 / 0x8D,
which carry \system\schedule\schedule.dat unpadded) — setups do not go through
the file transfer, and the file transfer is not how setups are written.
Reads are single-step — no probe
Series III sends every read twice (probe at offset=0x00 to learn the length,
then a data step). Thor skips the probe and asks for
offset = 0xFFFF, getting the whole block in one response:
41 02 10 10 00 1a 00 ff ff 00 … SUB 0x1A, offset 0xFFFF
→ 2,103-byte response
POLL is the exception — it uses offset = 0x0030 (48), its data length.
This does not contradict the probe response documented above; the probe still
works and still reports its length at payload[8:10]. Thor simply does not
need it.
Write-frame destuffing — 10 XX → XX, uniformly
Only the leading BW_CMD is doubled (10 10); after that every 10 XX pair
on the wire destuffs to XX, including 10 03.
This was settled by checksum, not by assumption. Four candidate rules were tested against all four data-carrying write frames; only this one makes all four checksums validate:
| rule | 0xDA |
0x68 |
0x82 |
0x71 |
|---|---|---|---|---|
10 XX → XX |
ok | ok | ok | ok |
only 10 03 → 03 |
ok | BAD | ok | BAD |
10 10→10, 10 03→03 |
ok | BAD | ok | BAD |
| nothing collapses | ok | BAD | ok | BAD |
0x71's data contains 4 literal 0x03 bytes, escaped as 10 03 on the
wire. A writer that does not escape 0x03 will emit a frame the device
terminates early — this is the same defensive ETX escaping Blastware does, and
it is mandatory, not optional.
Checksum is plain SUM8 of the destuffed payload; the DLE-aware form gives the same answer once destuffing is correct, so it does not discriminate.
The offset field is a per-command constant
| SUB | data bytes | offset |
note |
|---|---|---|---|
0xDA |
256 | 0x0100 = 256 |
= the name-field size |
0x68 |
88 | 0x005A = 90 |
identical to Series III's documented value |
0x82 |
28 | 0x001C = 28 |
identical to Series III's documented value |
0x71 |
2090 | 0x082C = 2092 |
= the length SUB 0x1A reports |
⚠ There is no single length formula — two are len, two are len + 2, and
Series III's data[1] + 2 rule does not reproduce either. Treat these as
observed constants the device accepted. Pinning the actual rule needs a second
capture whose payloads differ in size. (This document has already been wrong
once by inferring a length field; do not infer this one.)
The write body is the read body
The 0x71 write payload and the 0xE5 read response align at a fixed
11-byte shift with 1902/2090 bytes equal (91.0%) — the remaining 9% is
exactly what was edited.
So a setup is read-modify-write, the same shape as Series III, and a write client does not need to synthesise a config block from scratch.
Field map, from the read/write diff
Twelve differing regions, all accounted for. Offsets are into the 0x71
data section (= the read response's data + 11).
| offset | size | field | this capture |
|---|---|---|---|
0x0000 |
3 | block length echo | 08 2a (=2090) → zeroed on write |
0x0009 |
1 | unidentified | 3c → 02 |
0x0013 |
1 | unidentified | 00 → 40 |
0x002A |
44 | setup file name | → TEST1.mmb |
0x0090 |
42 | note 1 value — Location |
→ Test Location 1 - 1234 electric boogaloo |
0x00D0 |
42 | note 2 value — Client |
→ TMI |
0x0110 |
42 | note 3 value — Company |
→ ServersDownLabs |
0x0150 |
42 | note 4 value — General Notes |
→ Hopefully this works! |
0x0428 |
16 | sensor location | → Test Config Send |
0x06CA |
4 | Tran trigger level float32 BE | 0.3 → 0.5 in/s |
0x06FA |
4 | Vert trigger level | 0.3 → 0.5 in/s |
0x072A |
4 | Long trigger level | 0.3 → 0.5 in/s |
Notes block: four entries on a 64-byte stride, each [label: 22][value: 42],
labels at 0x008A + 64n. The labels are Location, Client, Company,
General Notes — not Series III's Project: / Client: / User Name: /
Seis Loc:, and they are fixed-width fields, not label: value pairs.
Channel blocks: six, 48 bytes each, from 0x06BC — Tran, Vert, Long,
Mic, LMic, SMic. Trigger level sits at label + 30.
The geophone scale factor is in the config block — and it confirms our LSB
Each geo channel block carries a float32 BE at label + 24:
40 46 98 dd = 3.10308003…
Which closes a loop from the file-decode work:
3.10308003… / 10000 = 0.000310308 = _GEO_LSB_IPS, to 8 figures
10.0 / 3.10308003… × 10000 = 32226.046 = the 32226.05 full scale
_GEO_LSB_IPS was derived statistically — intersecting 991,415 rounding
constraints from Thor's own CSV exports (see idf_protocol_reference.md).
The unit reports the constant directly, and it agrees. That upgrades the
value from a fit to a reading, and explains the odd full-scale count: the
Micromate's ADC is 10,000 counts per volt, and 3.10308 in/s per volt is
exactly half Series III's documented 6.206053 (ratio 1.99997).
Do not retune _GEO_LSB_IPS — this is corroboration, not a correction.
Still unknown on the write path
- What
0x68and0x82actually contain. Both were written with near-zero payloads here and nothing in them changed, so no field is located. Series III maps backlight/power-save/LCD-cycle into0x68; unverified here. - The three header bytes at data
0x0000/0x0009/0x0013. - Scheduler / call-home writes.
callhome.MMBis a file too, so it may go through the same0xDA+ block-write shape with a different target name.
✅ 0xDA CREATES setup files (confirmed on the device, 2026-09-24)
TEST1.mmb did not exist on the unit before the push. Afterwards it is
present in the unit's setup list and selected as the active config —
verified on the Micromate's own screen, not inferred from the ack.
So the four commands below are the complete setup-management path, and a homebrew client needs no file-transfer primitive and no pre-existing target:
0x41 read the active setup's name
0x1A read its config block ─┐ read
0xDA name the target .MMB ─┘ modify
0x71 → 0x72 write the block back write (creates the file if absent)
That closes the last open question about whether Series IV setup management is reachable from outside Thor. It is.
✅ Overwriting is protocol-identical to creating (2026-09-24)
The firmware carries strings that suggest an overwrite handshake:
Overwrite File MFS FILE EXISTS
Cannot be Overwritten Can Not Delete Active Setup File
There is no such handshake on the wire. A second push to TEST1.mmb — a
name that now existed, and which SUB 0x41 confirmed was the active setup —
produced a byte-for-byte identical command sequence:
| create | overwrite | |
|---|---|---|
| SUBs, and their order | 5B 41 08 2E 1A DA 68 73 82 83 71 72 |
identical |
every offset field |
— | identical |
0xDA / 0x68 / 0x82 data |
— | 0 bytes differ |
0x71 data |
— | 18 bytes differ = the one edited note |
| all seven write acks | 11 zero bytes | identical, still all-zero |
No extra command, no confirm step, no error status, and no dialog on Thor.
Those firmware strings belong to the on-device Save screen (the
CSaveSetupFile UI class), not to the protocol.
The overwrite was verified on the unit itself — the edited General Notes
string is present in the setup on the device, so the write applied, silently and
in place.
This is the case that mattered most, and it landed the right way round: the target was the active setup, which is what a real remote config push would hit. Being active bought it no protection — it was overwritten directly. A writer therefore needs no exists-check and no overwrite negotiation.
⚠ That cuts both ways. A remote push to the active setup of a monitoring unit changes the config it is recording with, with no prompt, no warning and no distinguishable ack. Whatever SFM eventually exposes should gate this on the operator, not on the protocol — the device will not stop anyone.
⚠ Two overwrite cases remain untested: a non-active setup file, and
factory.MMB, which Cannot be Overwritten probably guards. Neither blocks a
writer — the active setup is the one worth pushing to.
⚠ Note also that the write acks are all-zero in every case observed, across
a create and an overwrite. We have never seen this protocol report a failed
write, so do not treat a zero ack as proof a write was applied. Read the
config back and compare; SUB 0x41 plus SUB 0x1A make that cheap.
The scheduler, and a generic file transfer (2026-09-24)
Capture: bridges/captures/9-24-26 - micromate2/*_read_scheduler.bin.
25 request frames, 25 responses, every checksum valid.
Four operations in one capture, segmented by Thor's POLL preamble (marks are
not written into the raw .bin — in TCP mode seismo_lab logs them to the
on-screen log only):
| frames | operation |
|---|---|
| 0–4 | read the schedule off the unit |
| 5–18 | push a setup — the sequence already documented above, unchanged |
| 19–21 | write the schedule back |
| 22–24 | enable the scheduler |
🔑 SUB 0x94 / 0x48 / 0x8D / 0x8E — file transfer by path
The unit will read and write files addressed by full filesystem path.
0x94 <path> → 0x6B open for READ
0x48 → 0xB7 read next page; repeat until an all-zero response
0x8D <path> → 0x72 open for WRITE
0x8E <body> → 0x71 write the file body
The path is plain ASCII, unpadded, with offset = its exact length:
5c 73 79 73 74 65 6d 5c 73 63 68 65 64 75 6c 65 5c 73 63 68 65 64 75 6c 65 2e 64 61 74
\system\schedule\schedule.dat 29 bytes, offset = 0x001D
0x94 and 0x8D sent byte-identical 29-byte payloads — the same path, only
the command distinguishing read from write.
The 0x48 read is paged, and the page number comes back in the response header
at payload[3:5]:
| call | page | payload | content |
|---|---|---|---|
| 1st | 0x0000 |
15 B | descriptor — 04 00 … 01 00 00 00 00 00 01 |
| 2nd | 0x0002 |
535 B | the file body |
| 3rd | 0x0000 |
11 B | all zeros = end of file |
⚠ This is the single most consequential find of the session, because it is not
specific to the scheduler. callhome.MMB is a file too, and the call-home
config is the last unsolved piece of the project. Reading it should be a
matter of pointing 0x94 at the right path. That is a lead, not a result —
no path other than schedule.dat has been tried.
The schedule file itself
The write body is the read body minus an 11-byte response prefix (524 vs 535), so both describe the same structure:
03 00 00 00 0f 03 02 [namelen] [setup-file name] …zeros… 27 03 10
[namelen]is a length prefix:0x28= 40 for the 40-character name read off the unit,0x09= 9 forTEST1.mmbwritten back. Confirmed both ways.- The trailing
27 03 10sits at0x108in the write body and0x113in the read — the same offset once the 11-byte prefix is accounted for.
A schedule entry names a setup file. That is how the help text's "change the record mode" works: an entry says at this time, load this setup. It also means the scheduler and the setup list are coupled — deleting a setup that a schedule references is a foot-gun worth checking before we ever expose either.
✅ The entry internals ARE decoded — see The schedule record format below.
The file turned out to hold two 260-byte records, not one: 27 03 10 is the
second record's time/day fields, not a trailer. 1/2h is a half-hour slot and
both times check out against what the operator entered.
SUB 0x47 — the scheduler enable, probably
Step 4 is two bare 0x47 frames with no data, differing only in params[7]:
req params = 00 00 00 00 00 00 00 [01] 00 00 → rsp 04 00 … 00 [01] 00 00 00 00 00 01
req params = 00 00 00 00 00 00 00 [03] 00 00 → rsp 04 00 … 00 [03] 00 00 00 00 00 01
The response echoes the selector and ends 01. Its 15-byte shape is identical
to the descriptor 0x48 returns on page 0.
⚠ Whether 0x47 sets or merely reads is genuinely undetermined. Both calls
returned the same trailing 01, and there is no before/after to compare — the
scheduler was enabled in this same capture, so no "disabled" reading exists.
params[7] is also the token position Series III uses, which is suggestive but
not evidence. Do not implement an enable against this until a
disable-then-enable capture settles it.
The scheduler enable is NOT in the setup config block
A prediction made before this capture — that the Scheduler On/Off switch would
appear as a byte in the 0x71 block, because the unit's help text lists it in
the same edit screen as Record Mode and Sample Rate — did not hold.
The 0x71, 0x68 and 0x82 payloads are byte-identical to the previous
capture's, all three, zero differences. The scheduler was enabled without any
of them changing.
⚠ The test is weaker than it looks: the operator re-sent the same config, so
a byte-identical block is also what "nothing changed" looks like. What it does
establish is that enabling the scheduler did not require a config write —
whatever 0x47 does, it does alone.
Monitoring control and the setup list (2026-09-24)
Capture: bridges/captures/9-24-26 - micromate2/*_turn_on_monitormode_*.
Thor started monitoring, listed the unit's setups, and stopped monitoring.
40 request frames and 40 responses, every checksum valid.
Thor's per-operation preamble
Thor re-runs this before every operation — three times in this one capture:
POLL (0x5B) → SERIAL (0x15) → 0x49 → POLL (0x5B) → <the operation>
⚠ Whether the unit requires this is untested — see Thor's conventions vs
the protocol's requirements. Thor sends it before trivial reads too, so it may
be habit rather than handshake. Do not assume it is mandatory. Note POLL here carries offset = 0x0030 (its data
length), not 0xFFFF — POLL is the one read Thor still addresses by length.
SUB 0x96 / 0x97 — start and stop monitoring ✅
Identical to Series III, including the acks:
| request | ack | effect |
|---|---|---|
0x96 |
0x69 |
start monitoring |
0x97 |
0x68 |
stop monitoring |
Both are bare frames — no params, no data — and both ack with the usual 16-byte
zero-data response. Thor follows each with a SUB 0x1C status read to confirm.
SUB 0x1C — monitor status, 55-byte data
data[12] monitoring flag NON-ZERO = monitoring, 0x00 = idle
data[13] day
data[14] month
data[15:17] year, uint16 BE
data[17] ⚠ unidentified — 32 while monitoring, 100 when idle
data[18] hour ─┐ device clock, verified against the capture's
data[19] minute │ own wall time (19:12:25 → 19:13:34 EDT)
data[20] second ─┘
data[-8:-4] memory total, uint32 BE = 15,000,000 bytes exactly
data[-4:] memory free, uint32 BE
⚠ Test data[12] for non-zero — do NOT compare against a constant. It read
0x0E on 2026-09-24 and 0x0C on 2026-09-25, both while monitoring, so it
carries sub-state in its low bits rather than being a flag. Series III's 0x10
does not apply either. SUB 0x49 data[11] read 0x02 in every monitoring
sample so far, but the same caution applies until more values are seen. Only five bytes differ between the monitoring and idle
responses: the flag, data[17], the clock, and the memory-free field.
Memory free dropped by exactly 4,096 bytes across the ~70-second monitoring session — monitoring allocates as it runs, so free memory is not a stable value to compare against.
The device clock is free here, on a command Thor already sends. That is worth having: nothing else read so far reports the unit's own time.
SUB 0x49 → 0xB6 — a cheap state check
16-byte data, in Thor's preamble before every operation:
05 00 00 00 00 00 00 00 00 00 00 [ST] e8 00 0b 00
↑ data[11]: 0x02 monitoring, 0x00 idle
A second monitoring indicator, in a 21-byte response instead of 0x1C's 60.
Different encoding from 0x1C's flag (0x02 vs 0x0E), so they are separate
fields, not the same byte read twice. For a polling client this is the cheaper
of the two, and Thor evidently treats it as the routine one.
SUB 0x3F / 0x40 — walking the setup-file list ✅
The same first/next shape as Series III's 1E/1F event walk, applied to
setup files:
| request | ack | meaning |
|---|---|---|
0x3F |
0xC0 |
first setup record |
0x40 |
0xBF |
next setup record; repeat until the name is empty |
Every record is 266 bytes of data and carries nothing but the name:
ff 00 00 00 00 00 00 00 00 00 00 <null-terminated name> 00 …
└──────────── 11-byte header ─────┘
The walk ends on a record whose name is empty — 24 records for 23 setups.
factory.MMB comes first, from 0x3F.
There is no active-setup flag in the list. The header is byte-identical on
every record including the terminator, and the tail is all zeros. The active
setup is identified only by SUB 0x41, whose response uses this exact record
format. (On the unit's own screen the active setup is marked with a trailing
asterisk — that is a UI decoration, not a field.)
TEST1.mmb, created over the wire earlier the same day, appears in the list and
is what 0x41 reports as active — independent confirmation that a written setup
becomes a real, enumerable file.
Thor refuses to send a setup while a unit is monitoring
Send-to-unit is greyed out in Thor's UI when the unit is monitoring, and
nothing is transmitted — this capture contains no 0xDA or 0x71 at all.
That is a Thor-side policy, not a device refusal: nothing observed suggests the Micromate would reject the write. It squares with the earlier finding that a push to the active setup overwrites silently — Thor is preventing exactly the footgun the protocol leaves open.
The reason behind the rule is sound and SFM should honour it — but not
necessarily by copying the greyed-out button. Stop → push → restart as a single
operation is what an operator usually wants, and 0x49 data[11] (or 0x1C
data[12]) makes the state check cheap either way.
Static analysis of the firmware (2026-09-23, solo session)
Architecture
ColdFire / 68K, big-endian, Freescale MQX RTOS — not ARM as the vector
table first suggested. The giveaway is the function epilogue/prologue
4E 5E 4E 75 4E 56 = UNLK A6 / RTS / LINK A6, littered through both
images, plus an MQX_OK assertion string.
CB vs BD: the same source, ~10 lines apart
A byte diff is useless — 68% of bytes differ because the two are separately linked builds with everything relocated. A string-set diff is position-independent and tells the real story: 17,128 strings shared, and almost every "unique" string is the same message with a different source line number:
CB: MONITOR[3268]: STATUS_BATTERY_LOW
BD: MONITOR[3258]: STATUS_BATTERY_LOW ← consistently 10 lines apart
The offset is exactly 10 across STATUS_BATTERY_LOW, STATUS_BATTERY_CRITICAL,
Battery Critical Exit Monitor, histogram interval size of 0 and
Offsets by channel — so one ~10-line block differs in the monitor module and
essentially nothing else. The only functional string unique to either build is
CITIZEN (a receipt-printer brand) in BD.
This corroborates the bench A/B from the other direction: the CB/BD split is a tiny code delta, not two protocol stacks. Whatever drives Instantel to ship two downloads, it is not a different wire protocol.
⚠ The SUB dispatch is a 68K switch jump table (CMPI.L bounds check →
MOVE.W (table,PC,Dn) → JMP (d8,PC,Xn)). Byte-pattern hunting will not
isolate the write opcodes — that needs a real disassembler.
Call-home config field names, from the firmware's own debug dump
CallHome.Enable = %s
CallHome.DialString = "%s"
CallHome.Retries = %d
CallHome.SessionTimeout = %d
CallHome.WaitForConnection = %d
CallHome.WarmupTime = %d
CallHome.PowerSave = %s
Seven fields, which is what the 126-byte SUB 0x2C block has to encode. Note
SessionTimeout and PowerSave have no Series III equivalent, and Series III's
scheduled-time fields (time1/time2 hour/min) are absent here — consistent
with Series IV moving scheduling into the THOR-downloaded scheduler instead.
Also present: AT+CSQ (signal quality), so the firmware talks AT to the modem
directly.
All five bench events, downloaded and decoded
Read-only, over USB, no Instantel software:
| key | declared size | got | decoded |
|---|---|---|---|
055d4a81 |
4,076 | 4,076 | histogram, 1 interval, 16:33:16 |
055d4a82 |
11,032 | 11,032 | waveform, 3072 × 4 ch, 16:33:19 |
055d4a83 |
11,502 | 11,502 | waveform, 3072 × 4 ch, 16:33:27 |
055d4a84 |
13,424 | 13,424 | waveform, 3072 × 4 ch, 16:33:34 |
055d4a85 |
8,746 | 8,746 | waveform, 2048 × 4 ch, 16:33:36 |
Every event arrived at exactly its declared size, every channel came out equal length, and the timestamps are sequential across the recording session.
Record type + filename: generate it, don't detect it
read_idf_file() decides waveform vs histogram from the filename suffix —
and there is no filename when downloading over the wire.
⚠ Worth correcting a natural assumption: Series III does not detect this from
content either. event_file_io.derive_record_type_from_filename() reads the
last character of the extension (M529LKIQ.G10H → H → Histogram). Nothing
in the codebase infers record type from file content, for either family.
And there is no obvious type field to find. The first 64 bytes of a histogram
and a waveform are byte-identical; they diverge at ~0x0947 into wholly
different structures rather than differing by a flag.
The answer is the Series III pattern — generate the name. Series III has
blastware_filename(), which builds a name from serial + timestamp + type.
Series IV needs the same thing, and its convention is far simpler:
<serial>_<YYYYMMDDHHMMSS>.IDF{W,H} e.g. UM12947_20260923163319.IDFW
versus Series III's <letter><serial3><4-char base-36 stem><AB0T ext>, where
the stem is base-36 of seconds-since-1985 ÷ 1296.
All three inputs are already available on a direct download:
| input | source |
|---|---|
| serial | extract_binary_metadata() — decoded from the IDF header |
| timestamp | extract_binary_metadata() — same |
| type | the chain walk — SUB 0x0A length 0x1E = histogram, 0x00 = waveform |
Verified against all five bench events: the generated names match the
convention of real files in the production store byte for byte. A directly
downloaded event can therefore be filed under exactly the name Thor would have
given it, and /db/import/idf_file needs no change at all.
⚠ The type still comes from the protocol, not the payload — so a downloader must carry it out of the chain walk. Losing it means losing the ability to name the file correctly.
⚠ Unresolved: the 0x0C peak float
The float32 extracted from 0x0C runs 2–5% above max(Tran, Vert, Long) from
the decoded samples:
| key | 0x0C float |
max channel |
|---|---|---|
…81 |
3.5152 | 3.4419 |
…82 |
1.3720 | 1.3706 |
…83 |
2.3542 | 2.2227 |
…84 |
3.5152 | 3.4419 |
…85 |
0.4227 | 0.4198 |
It is not peak vector sum either (computed PVS runs higher than both). The field may not be the peak at all — its offset was inferred from a byte marker, not established. Do not rely on it until it is pinned properly.
Worth noting the histogram (…81) and the loudest waveform (…84) report
identical peaks to four decimals, in both measures. That is self-consistent:
the histogram's single 1-minute interval spans the whole thumping session, so
its maximum should equal the loudest event in it.
Event download, per-event delete, and ACH config (2026-09-25)
Three captures with operator-supplied ground truth, including Thor screenshots of the event list and the schedule. All Thor-originated; we still send nothing.
✅ Day is the day of week — and [0] is the schedule type
A weekly schedule settles both fields. Thor's screen: "multiday, Repeat Weekly: Disabled, Start Monitoring at 8:00 AM every day, alternating TEST1 / test2." The file is 7 × 260 + 4 = 1,824 bytes, and every record matches:
| rec | 1/2h |
time | Day |
[6] |
name | |
|---|---|---|---|---|---|---|
| @0 | 16 | 08:00 | 0 | Sun | 2 | TEST1.mmb |
| @260 | 16 | 08:00 | 1 | Mon | 2 | test2.mmb |
| @520 | 16 | 08:00 | 2 | Tue | 2 | TEST1.mmb |
| @780 | 16 | 08:00 | 3 | Wed | 2 | test2.mmb |
| @1040 | 16 | 08:00 | 4 | Thu | 2 | TEST1.mmb |
| @1300 | 16 | 08:00 | 5 | Fri | 2 | test2.mmb |
| @1560 | 16 | 08:00 | 6 | Sat | 2 | TEST1.mmb |
Day = 0 Sunday … 6 Saturday, and the alternating setup names line up with
the screen row for row.
[0] on record 0 read 4 here, against 2 and 3 in the daily schedules —
so it carries the schedule type as well as Repeat:
[0] |
meaning |
|---|---|
2 |
Daily, repeat off |
3 |
Daily, repeat on |
4 |
Weekly, repeat off |
5 |
Weekly, repeat on — ⚠ predicted, not observed |
Bit 0 is Repeat; 2 and 4 are the Day/Week bases. Same bitmask style as
[6].
⚠ In daily schedules Day reads 3 in every record of every capture. With
[0] already saying "daily", the field is presumably ignored there — but that is
inference, and 3 is unexplained.
Event download — SUB 0x93 arms each event
Thor's download of six events:
POLL 0x15 0x49 POLL 0x1C 0x15 0x49 0x06
0x93 0x1E 0x0C 0x5A×4 ← event 1
0x93 0x1F 0x0C 0x5A×11 ← event 2
0x93 0x1F 0x0C 0x5A×12 ← event 3
0x93 0x1F 0x0C 0x5A×14 ← event 4
0x93 0x1F 0x0C 0x5A×9 ← event 5
0x93 0x1F 0x0C 0x5A×6 ← event 6
0x93 0x06 0x93 0x1E 0x0A×9 ← re-walk the list
SUB 0x93 → ack 0x6C is sent before every event, with empty params and an
all-zero ack. It is the Series IV analogue of Series III's 1E(token=0xFE) arm
step, and it is simpler: no token, no params.
Event keys are a plain sequential counter. The six events walked as
055D4A81 … 055D4A86, consecutive, at data[11:15] of the 0x1E/0x1F
response, with the event's byte size at data[17:19]. Nothing like Series III's
flash addresses.
SUB 0x0A walks the event list returning 30-byte records carrying start and
stop timestamps ([11] day, [12] month, [13:15] year BE …), terminating on
an all-zero record. The dates match Thor's event list exactly (five events on
09/23/2026, one on 09/24/2026).
🔑 Delete is PER-EVENT — SUB 0xA8 + 0xAA
0xA8 params[0:4] = <event key> → ack 0x57
0xAA params = zeros → ack 0x55
The operator deleted the top row of Thor's list — the newest event — and
0xA8 carried 05 5d 4a 86, the highest key from the walk. Thor lists
newest-first, so newest = highest key. Confirmed end to end.
This is the last piece a homebrew ACH receiver was missing. The manual established that collection state is server-side bookkeeping and that "delete events from unit" is a separate server-issued action; this is that action's opcodes.
Two things worth noting against Series III:
- Series III erases everything (
0xA3 → 0x1C → 0x06 → 0xA2). Series IV deletes one named event, which is strictly safer — a receiver can delete exactly what it has confirmed it stored. - The opcodes are different. Do not reach for
0xA3/0xA2here.
⚠ SUB 0x06 (storage range) read identically before and after the delete in
this capture, so it is not a quick way to confirm a deletion landed. Re-walk the
event list instead.
✅ ACH config — 0x2C / 0x7E / 0x7F, exactly Series III
Thor enabling then disabling Auto Call Home, twice through the same sequence:
POLL → 0x15 → 0x49 → POLL → 0x2C (read) → 0x7E (write, 126 B) → 0x7F (confirm)
Same SUBs and the same acks as Series III — 0x2C→0xD3, 0x7E→0x81,
0x7F→0x80. The write payload is 126 bytes with offset = 0x007E, and
the 0x2C read returns those same 126 bytes behind an 11-byte prefix, so
read[n + 11] is write[n].
The enable flag is write[5] (= read[16]):
| value | state |
|---|---|
0x05 |
Auto Call Home enabled |
0x04 |
disabled |
Bit 0 is the enable — the same bit position Series III uses at raw[5], but with
bit 2 set as well in both states. Do not test for 0x01/0x00.
write[6:] holds the dial string, null-padded — "RADIO RING" on this unit,
matching Series III's raw[6:46].
⚠ write[118:120] — a field the UNIT maintains
Three samples:
| when | enable | field |
|---|---|---|
| 00:50, idle (schedule session) | 0x04 |
43 23 |
| 01:16, ACH read #1 | 0x04 |
43 23 — unchanged after 26 min |
| 01:16, ACH read #2, after a config write | 0x05 |
2e 5e |
Thor echoes back whatever it last read, including a value that no longer matches the config it is sending — and the write is accepted anyway.
What that rules out:
- Not a clock or timer — identical across 26 minutes of idle. Only a config write moved it.
- Not a counter — it went down, 17187 → 11870.
- Not computed by Thor — Thor demonstrably sends a stale value.
- Not a standard CRC16. Brute-forced all 65,536 polynomials × init
{
0x0000,0xFFFF} × all four reflection combinations, over four candidate regions ([0:118],[0:118]+[120:],[5:118], and the payload with the field zeroed). No match. Recorded so nobody repeats the sweep.
It behaves like a hash or checksum the unit computes over the stored config: a
one-byte input change (0x04→0x05) scattered the output completely, XOR
0x6D7D, where a sum would have moved by 1. But two samples cannot separate
that from a nonce regenerated on each write.
✅ Operationally this does not matter. The unit does not validate the field on input — Thor proved that twice in one capture. Read the config, change your field, send everything else back byte-for-byte. Never synthesise or zero it. Same read-modify-write shape as the setup block.
Resolving it properly needs more samples: several config writes with the times noted, which is cheap to collect during any future ACH capture.
Neighbouring bytes: write[117] is 0x03, lining up with Series III's
num_retries of 3, and write[120:122] is 00 3c = 60.
⚠ Beyond the enable byte and the dial string, the field map is not established — only one setting was varied. Series III's offsets are a starting hypothesis, not a transfer.
What the THOR manual settles about the ACH session (2026-09-24)
Source: manuals/723U0201 THOR Operator Manual Rev 08.pdf §6.2, §3.6.
⚠ This is vendor documentation, not observed bytes. It tells us the shape of
the session and the vocabulary; it does not give opcodes. Treated as a strong
prior, not as confirmed protocol.
🔑 A unit does NOT learn that an event was accepted — the server decides
This document previously listed, as the thing gating any homebrew receiver:
how a unit announces itself, and how it learns an event was accepted so it stops re-sending it.
That was the wrong question. There is no acknowledgement mechanism to discover, because the unit is not tracking what has been collected. Per §6.2.2.2 the ACH session is a list of server-chosen actions, and two of them are independent:
| ACH action | what it does |
|---|---|
| Copy events | downloads events — "Only applies to events not previously downloaded" |
| Copy monitor log | downloads the monitor log |
| Delete events and Logs from Unit | explicitly deletes them from the unit |
| Set Date/Time | unit synchronises its clock from the computer |
| Send Events / Schedule to Vision | Instantel cloud, not relevant to us |
"Not previously downloaded" is computer-side bookkeeping. The unit keeps its events until a server tells it to erase them, and the manual's own warning proves the two are decoupled:
⚠ "If you enable 'Delete Events and Logs from Unit' but disable 'Copy Events'. The events and logs will be deleted without being uploaded."
A server that never issues the delete simply re-reads the same events forever.
This is exactly the model our Series III ACH server already implements —
ach_state.json with downloaded_keys / max_downloaded_key, and erase as a
separate deliberate step. No new mechanism is needed for Series IV.
So a homebrew receiver needs: accept the connection, identify the unit, walk the
events (already solved — 0x08/0x1E/0x0A/0x5A), keep our own high-water
mark, and optionally erase. The erase opcodes are the only genuinely missing
piece, and they remain on the unsafe list.
The session is server-driven
Which matches the firmware's state machine and its
CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING /
Call Home Deleting Events strings: the unit dials in, then waits to be told
what to do, and returns to monitoring when the server is finished.
Scheduled ACH and event-triggered ACH behave differently (§3.6.1):
- Event-triggered (ACH enabled on the unit, an event occurred) — "Records events + transfer data, no stopping to monitor." Governed by Monitoring While Calling Home; with MWCH enabled "the monitor log will not be copied, events will not be deleted, and time will not synchronize".
- Scheduled — "Stop monitoring + transfer data (or delete events, or synchronize)." Monitoring stops and in-progress events complete first.
⚠ Worth noting for SFM: with MWCH on, an event-triggered session cannot delete or sync. A receiver that relies on erase to avoid re-reading will silently never erase on those units. Our high-water mark must be the primary mechanism, with erase as an optimisation — which is how Series III already does it.
Session Time Out is unit-side only
§6.2 is explicit that THOR configures ACH on both ends "with one exception; the
Session Time Out. This must be configured directly on the unit." That matches
the firmware's CallHome.SessionTimeout field, and means it lives in
callhome.MMB rather than anywhere THOR reaches — one more reason to read that
file with 0x94.
Unit identification is by serial number, with wildcards
§6.2.2.2: filters match against the serial number the unit presents, *
wildcards allowed, best-match wins — UM* all Micromates, MP* all Minimate
Pros, BE/BC Minimate Plus variants.
So the unit announces its serial early enough for the server to route on it.
SUB 0x15 returns the serial and is in Thor's standard preamble, which is
consistent, though the inbound direction has still never been observed.
⚠ The manual's worked example contradicts its own table — it says "To filter Micromate units type MP"* and "To filter Minimate Pro units type UM"*, which is backwards. The table is right. Noted so nobody copies the error.
Thor requires Idle for configuration
§6.2.1 step 3: "The Monitoring Mode must be 'Idle'." Independent confirmation that the greyed-out send observed on the bench is deliberate Thor policy, applied to ACH setup as well as compliance setup — and still not evidence the device refuses.
The schedule's actions, from the UI side
§3.6 lists exactly four actions THOR exposes: Start monitoring, Stop
monitoring, Self-check, Auto Call Home. The firmware has five — it also has
a setup-less DUTYCYCLE_START_MONITOR.
§3.6.2 step 8 confirms the coupling is Thor's own requirement: "Select the
appropriate Action and the Unit Setup. (A Unit Setup must exist…)" — while §3.6.2
step 1 notes "The unit will execute any actions in a schedule using its current
settings." The two statements sit a paragraph apart and pull in opposite
directions, which is consistent with START_MONITOR existing and THOR never
emitting it.
Also from §3.6: schedules are Day or Week ("Select Day… Select Week"), have a
Repeat Daily / Repeat Weekly flag, carry a Name, Description and Unit Type,
and "Saving a schedule will only store it on the computer, it must still be sent
to the unit and enabled" — which is why the capture shows 0x8E (send) and
0x47 (enable) as separate steps.
Those are the fields to look for when the schedule entry is finally decoded:
action, setup name, time, day-or-week, day selection, repeat. The one
captured entry (03 00 00 00 0f 03 02 …) has seven bytes before the name, which
is the right order of magnitude for that field list.
What THOR's "status check" actually is (2026-09-25)
Captured with bridges/mm_link.py standing in for the modem, THOR configured
Communication: TCP, Check connection every 5 s, Check status every 5 s.
It is eleven commands, not one
POLL → DEVICE_INFO → 0x49 → 0x5C → MONITOR_STATUS → SETUP_NAME_READ
→ STORAGE_RANGE → 0x02 → OPERATOR → 0x47 → CALLHOME_CFG
Each check opens a new TCP connection, runs all eleven exchanges in ~300 ms, and closes it. Measured over 21 consecutive checks:
| request payload | 236 B |
| response payload | 936 B |
| TCP connect + teardown | ~1,000 B (fresh handshake every time) |
| per check | ~2.2 KB |
The cost
| cadence | checks/day | per unit |
|---|---|---|
| every 10 s (as observed) | 8,640 | 18.8 MB/day — 563 MB/month |
| every 60 s | 1,440 | 3.1 MB/day — 94 MB/month |
| every 15 min | 96 | 0.2 MB/day — 6 MB/month |
⚠ On a metered cellular plan this is real money, and most of it is waste.
A status check re-reads the call-home config, the operator name, the active setup
name and the full device info block every ten seconds — none of which changes
between checks. SETUP_NAME_READ alone returns 274 bytes each time.
A genuine liveness + state check is POLL + MONITOR_STATUS: two commands,
131 bytes of response. Same information about whether the unit is alive and
whether it is monitoring, for a ninth of the traffic.
There are TWO checks, and only one of the dials is honoured
The eleven-command sequence is the status check. There is also a much cheaper connection check — three commands:
connection check POLL → SERIAL → 0x49
status check POLL → DEVICE_INFO → 0x49 → 0x5C → MONITOR_STATUS
→ SETUP_NAME_READ → STORAGE_RANGE → 0x02 → OPERATOR
→ 0x47 → CALLHOME_CFG
⚠ With both dials equal, the connection check never runs separately at all — every connection observed was the full eleven. It only appears once the two intervals differ. That alone explains a lot of "changing the settings does nothing": at equal values you only ever get the expensive one.
With connection check = 10 s and status check = 30 s, the steady state over 14 consecutive cycles is:
FULL at T
short at T + 10.1
short at T + 25.3 (+15.2)
FULL at T + 30.4 (+5.1)
| dial | set to | observed | |
|---|---|---|---|
| status check | 30 s | 30.4 s | ✅ honoured |
| connection check | 10 s | 15.2 s | ❌ 52% slow |
27 consecutive connection-check gaps, all 15.1–15.3 s. That is systematic, not jitter.
⚠ A "half the status period" hypothesis was raised here and REFUTED. It predicted that with status at 60 s the connection check would run at 30 s. Measured: 60.5 s. Recorded rather than deleted — the prediction was sharp and it was wrong.
Modem settings live in SysParm.cfg, not in the setup — and that is deliberate
Settled by experiment (2026-09-25). The unit's call modem setting was
changed on the keypad from generic to USB to PC. Then the active setup was
switched from TEST1 to test2 on the device, and the setting was checked
again: unchanged.
So it does not travel with the setup. It is device-global, in the SysParm.cfg
the firmware strings already hinted at, alongside SysPref.bMonitorScheduler.
That closes a hypothesis this document was pursuing: the ~102 bytes a .MMB
file carries beyond the 2,090-byte config block are not where this lives.
Those bytes remain unexplained, but they are no longer a candidate for it.
⚠ It also means the earlier observation "the call-home block (0x2C) was
byte-identical across 218 samples today" does not bear on this — the last
0x2C sample was at 13:30:23 and the keypad change came around 13:35. No sample
exists on the far side of it.
Why the split is the right design
The operator's reading, and it is convincing: you do not want modem settings reachable remotely. Get them wrong over the air and you lose the connection you would need to put them back — the unit must then be visited physically.
That explains the shape of the protocol rather than treating it as an oddity:
| reachable over the wire? | |
|---|---|
Call Home enable, dial string, retries, timings (0x2C / 0x7E) |
yes — recoverable if wrong |
Modem type and the rest of SysParm.cfg |
no — a wrong value is unrecoverable remotely |
SUB 0x2C is not an incomplete view of the modem configuration. It is the
deliberately-chosen subset that is safe to change remotely, and the
unreachable remainder is unreachable on purpose.
Design principle for SFM
There is a class of setting whose misconfiguration destroys the channel you would use to fix it — modem type, baud, serial parameters, the call-home destination itself. For those:
- Do not expose them for remote write, or gate them behind an explicit confirmation that names the risk.
- If they must be writable, use a commit/confirm with automatic rollback — apply, require the unit to call back within N minutes, revert if it does not.
- Always allow reading them, so an operator can diagnose a unit they cannot reconfigure.
Instantel chose option 1. Given the failure mode, that is defensible, and worth copying rather than improving on.
The connection dial sets a COUNT, not a period
Three configurations, each measured over many cycles:
| status | connection | status observed | connection observed | separate conn checks per status cycle |
|---|---|---|---|---|
| 10 s | 10 s | 10.1 s ✅ | — | 0 (none ever ran) |
| 30 s | 10 s | 30.4 s ✅ | 15.2 s ❌ | 2 |
| 60 s | 30 s | 60.5 s ✅ | 60.5 s ❌ | 1 |
The status dial is honoured in all three — within about 1%.
The connection dial is not honoured in any of them. What actually holds is:
separate connection checks per status cycle = (status ÷ connection) − 1
1 → 0 checks, 3 → 2 checks, 2 → 1 check. So the field does not set a period; it sets how many checks fit inside a status cycle, and it is off by one.
Consequences worth naming:
- Setting the two dials equal yields zero connection checks. Every connection is then the expensive eleven-command status check. That is the default-looking configuration, and it is the worst one.
- "Every 30 s" with status at 60 s gives one check per minute — half the advertised rate.
- The observed cadences are not multiples of the connection setting at all (10 s → 15.2 s; 30 s → 60.5 s), so no simple scale factor describes it either.
⚠ The timing within a cycle is still not fully explained. At status 30 / connection 10 the two short checks landed at T+10.1 and T+25.3, where an evenly divided cycle would put them at T+10 and T+20. The count rule holds across all three configurations; the phase does not follow from it.
For SFM: this is the concrete argument against exposing a dial whose behaviour is not what it says. If a control sets an interval, it should set that interval — and if the effective rate is derived from something else, the UI should show the derived value, not the input.
Traffic at each configuration
| status / connection | per minute | per day | per month |
|---|---|---|---|
| 10 s / 10 s | ~13 KB | 18.8 MB | 563 MB |
| 60 s / 30 s (current) | ~3.4 KB | 4.9 MB | 147 MB |
| a minimal check at 60 s | ~0.2 KB | 0.3 MB | 9 MB |
The last row is POLL + MONITOR_STATUS only — enough to answer "alive?" and
"monitoring?".
⚠ What this means for the "won't stay connected" failure
Because idle polling opens a fresh connection each time, a silently-dead link is less dangerous here than expected — a dead socket fails at connect and the next cycle simply tries again. The earlier hypothesis (THOR wedged on a half-open socket during polling) is weakened by this.
The exposure is during operations, not polling: THOR was observed holding one connection from 00:30 to 00:47 — seventeen minutes — while downloading events and pushing setups. A link that dies silently mid-operation leaves THOR waiting on a socket the OS will not fail for roughly the default keepalive (~2 h). That remains the best candidate for a unit that will not come back and where refresh does nothing.
Testable with mm_link.py: set blackhole during a download or config
push rather than while idle, and watch whether THOR ever gives up, whether
refresh emits any bytes, and whether it recovers when pass is restored.
Design notes for SFM
Three things this argues for, all cheap:
- Separate liveness from inventory. Poll
POLL+MONITOR_STATUSfrequently; read config, setup name and call-home settings only when something says they changed, or on demand. - Show the connection attempt. Every check here has a visible outcome — connected, frames exchanged, closed. THOR surfaces none of it, which is why a failing unit is undiagnosable from the UI. The log this section is built from took one afternoon to produce and answers questions THOR cannot.
- Bound every operation with its own timeout, independent of TCP's. Do not rely on the socket to report a dead peer.
Reproduced: THOR stops polling after a connection drops mid-download
2026-09-25, one trial, on the bench link. This is the failure the operator described in the field on UM12947 — "just wouldn't stay connected… clicking the little refresh button did nothing… no way to view the status of a connection attempt."
What was done
THOR was downloading events. Partway through the bulk transfer the link was faulted, the connection died, and the link was then fully restored.
⚠ What THOR actually experienced was a TCP close mid-download, not the silent
link that was intended — mm_link.py had a bug (socket.timeout subclasses
OSError, so 200 ms of quiet was mistaken for a closed socket). Fixed, but the
run stands as a drop-mid-download test, which is arguably the more realistic
case: a modem losing its tower often does produce a real close.
What happened
13:02:49.0 THOR connects, bulk download running (165 BULK_DOWNLOAD frames in)
13:02:50.0 link faulted -> connection dies mid-transfer
13:03:10.4 THOR reconnects once, 20 s later, sends SUB_1F (advance event
pointer) — an attempt to resume
13:03:10.8 that attempt dies too
13:03:33.3 link fully restored and healthy
... 48 s of complete silence ...
13:04:21.4 operator clicks Refresh -> full 11-command check, every response
correct, unit perfectly healthy
... 2 min 6 s of complete silence ...
13:06:27 still nothing. That refresh is the ONLY connection since 13:03:10.
Before the fault THOR was connecting every 30 s without a miss for over an hour.
What this establishes
- One retry, then give up. THOR retried once after 20 s and stopped. No backoff, no further attempts.
- The automatic poll loop dies with it. Not just the download — the 30 s connection check and 60 s status check both stopped entirely.
- It does not recover when the link returns. Sixteen minutes of healthy link produced no automatic connection attempts at all — only ones an operator initiated by hand.
- Refresh works, but only once. The manual check succeeded completely — all eleven commands, correct responses. It did not restart the automatic loop; two minutes later there was still nothing.
⚠ Point 4 is the dangerous one. Refresh makes the UI report a healthy unit while nothing is actually watching it. The operator sees a successful check and moves on; the background loop stays dead. That is worse than a refresh button that plainly fails, because the failure is silent and looks like success.
🔑 "Not polling" and "unreachable" are different states — and THOR conflates them
Demonstrated directly. At 13:10:44 an independent POLL through the same
relay succeeded with a correct response while THOR's automatic polling was dead.
⚠ A correction, recorded because the first version of this claim was sloppy.
It originally read "THOR connections since 13:04:22 : 0". That count was an
artifact of a time filter (13:0[4-9]) that silently dropped everything from
13:10 onward. THOR had connected four times, at 13:10:03–13:10:37.
Inspecting those four shows the conclusion survives — but for a better reason than the one first given. They were user-initiated commands, not polling:
13:10:03 POLL → SUB_96 (start monitoring) 13:10:05 MONITOR_STATUS
13:10:35 POLL → SUB_97 (stop monitoring) 13:10:37 MONITOR_STATUS
Single commands a human clicked, each followed by one status read. Neither the eleven-command status check nor the three-command connection check appears.
Automatic polling did not resume, and by 13:19:53 had been absent for 16 minutes. Every THOR connection in that window was something an operator clicked: the refresh at 13:04:21, then start and stop monitoring at 13:10.
The unit is reachable. The link is fine. THOR is simply not asking.
THOR reports Connection Status: Connected. Captured at 13:15, eleven
minutes after its last contact with the unit:
Connection Status : Connected <- false; nothing checked in 11 min
Last Updated : 09/25/2026 01:04:22 PM <- true, and that is the REFRESH
Notification : "Unable to download event(s) from UM12947 due to:
Did not receive response from unit." (01:03:31 PM)
Three things worth separating:
- The green tile is false. It reports a live connection that has not been exercised for eleven minutes.
Last Updatedis true — and it is the only honest field on the screen. THOR knows when it last succeeded. It renders that as small grey text under the unit name, unhighlighted, with nothing marking it stale, beneath a large green Connected tile. The operator must read a timestamp and do mental arithmetic to discover the headline is wrong.- The failure THOR did report was the download, not the poller stopping. Those are treated as unrelated events; nothing says "automatic checking has ceased."
So the state "I have given up checking this unit" is not merely undisplayed — THOR holds the data that would reveal it and presents a contradicting summary instead. So an operator cannot separate the unit is down from the poller is asleep — and those demand completely different responses: a site visit versus a mouse click.
This also settles a question the previous section left open. It does not much matter whether stopping after one retry is an intentional design choice or a defect: the reporting is wrong either way, because both plausible displays misrepresent reality.
It explains, too, why the field symptom resisted characterisation. The unit is perfectly reachable throughout. Poke it and it answers. Nothing is wrong with the unit, the modem, or the link.
The stale display extends to monitoring state — a live unit shown as Idle
The operator's own test: start monitoring from the unit's keypad, and see whether THOR ever notices.
At 13:21:15, verified by an independent probe through the same relay:
unit, on the wire SUB 0x49 data[11] = 0x02 MONITORING
SUB 0x1C data[12] = 0x0c MONITORING
device clock 13:21:14
THOR's last contact 13:10:37 (a stop-monitoring command it issued itself)
THOR's display Connected · Monitoring Mode: Idle · Last Updated 1:04:22 PM
A unit is actively recording and THOR shows it as Idle. Had an event triggered in that window, THOR would not have known and would not have collected it. This is the operational consequence of the wedge: not merely a wrong indicator, but a monitoring system that has silently stopped monitoring its monitor.
One further detail. THOR did contact the unit at 13:10:37 and read
MONITOR_STATUS — yet Last Updated still reads 1:04:22. So a successful
exchange does not refresh that timestamp; only the full status check does. The
single honest field on the screen is honest about the wrong thing, which makes it
useless as a staleness indicator precisely when staleness is the problem.
Design consequences for SFM
- Connection status must EXPIRE. The single highest-value fix here. If the last successful check is older than a small multiple of the check interval, the state is stale / unknown — never Connected. THOR already has the timestamp; it simply does not let it invalidate the summary.
- Retry must be unbounded with backoff, never one-and-done. A transient link fault should not take a unit out of service until a human notices.
- A manual check must restart the automatic loop, or the UI must state clearly that automatic checking is stopped. A green tick that means "it worked when you asked" is a trap.
- Surface the poll loop's own state — last successful check, last attempt, next scheduled attempt, consecutive failures. All four were invisible here, and every one of them would have made this diagnosable in seconds.
- Distinguish "unit unreachable" from "we stopped checking." Proven above to be different states that THOR cannot tell apart. A unit's displayed state should be one of: checks passing, checks failing (with the attempt count and last error), or not being checked (with why, and a way to resume). Collapsing the last two into one indicator is the root of this whole failure being undiagnosable.
Caveats
- One trial. Not yet repeated, and not yet tried with a true silent link
(
blackholewith the fixed tool) or with a cleandrop. - THOR's UI state during the dead window was not recorded — worth capturing on a repeat, since what the operator sees is half the problem.
- Whether a THOR restart is required, or whether it eventually recovers on a longer timescale, was not tested.
Thor's conventions vs the protocol's requirements
SFM is not meant to reimplement Thor. Thor is the only available teacher of the wire protocol, but almost nothing about how it sequences its work has been shown to be required by the device. Those are two different things and this document should not blur them.
The distinction matters because several observations above were written as "a client should do X" when the honest statement is "Thor does X, and we have not checked whether the unit cares."
| Thor does this | required? | what it means for SFM |
|---|---|---|
POLL → 0x15 → 0x49 → POLL before every operation |
unknown | Series III needed POLL×3 before 5A specifically, so a preamble requirement is plausible — but Thor sends this before trivial reads too. Testable: issue one operation cold and see if it answers. |
Reads with offset = 0xFFFF, skipping the probe |
no — the probe works | We have a genuine choice, and the probe is arguably better: it reports the length instead of making us trust a fixed one. This is the one place Thor's shortcut is probably worse. |
Sends 0x68 + 0x82 in every setup push |
unknown | In both setup captures these carried near-zero payloads and changed nothing. If they are optional, a setup write is 3 frames instead of 7, with less to get wrong. Worth testing before we build the writer. |
| Rewrites the whole 2,090-byte config for a one-field change | unknown | No narrower write has been observed. Read-modify-write is safe and known; a targeted write would be nicer but is unevidenced. |
Reads 0x41 twice in a row (scheduler capture, frames 6 and 8) |
no | Plainly redundant. A reminder that Thor's sequence is not a minimal one. |
| Greys out send-to-unit while monitoring | Thor policy | The reason is real — a push to the active setup overwrites silently. But "the button is grey and you figure it out" is a UX choice, not the only answer. SFM could offer stop → push → restart as one operation, which is what an operator actually wants. |
Names the target with 0xDA before a config write |
almost certainly required | The unit has to know which file to write. Closest thing here to a genuine protocol requirement. |
The schedule↔config coupling is Thor's, not the protocol's
In Thor, putting "start monitoring" in a schedule forces you to attach a setup, and sending the schedule pushes that setup at the same time — overwriting whatever already has that name. The protocol does not require any of this.
The evidence, from the scheduler capture:
-
The two writes are separate operations, not one transaction. The config write ends at frame 18 (
0x72), then Thor sends a freshPOLLpreamble, and only then opens the schedule for writing at frame 20. Different commands, different paths, no shared state:config 0xDA → 0x68/0x73 → 0x82/0x83 → 0x71/0x72 schedule 0x8D → 0x8E -
The schedule stores a NAME, not a config. A length-prefixed filename is all an entry carries. It is a reference, and references do not require the referent to be rewritten.
-
The config Thor pushed was already on the unit, unchanged. Its 2,090-byte
0x71payload is byte-identical to the previous capture's — zero differences. Thor spent a full block write re-sending a setup the device already had, purely to satisfy its own coupling.
So the sequencing is a Thor UI decision, and a costly one.
What SFM can do instead, with today's protocol and nothing new:
- Enumerate the unit's setups with
0x3F/0x40— cheap, read-only, and it yields the exact names a schedule may legally reference. - Write only the schedule (
0x8D/0x8E) when the referenced setup is already present. - Push a config only when it is actually missing, or when the operator deliberately edited it — and say so explicitly rather than silently.
That removes the write entirely from the common case: scheduling against a setup that already exists becomes a 524-byte schedule write instead of 524 bytes plus a 2,090-byte config overwrite.
⚠ And it removes a real hazard. Because the reference is by name, and because a same-name write overwrites silently with an indistinguishable ack, Thor's pattern means scheduling something can quietly rewrite a setup that other schedules — or the operator's own saved work — depend on. Nothing in the protocol or the ack reports that this happened. Validating the reference instead of rewriting the referent avoids the whole class of problem.
✅ The schedule record format — DECODED (2026-09-24)
A debug printf in the scheduler names the fields outright:
SCHEDULER : _ReadRecord(%d) -> %s (Action=%u, 1/2h=%u, Day=%u, Setup="%s") [WDAY=%d]
The captured file is two 260-byte records plus four zero bytes — 524 bytes exactly. Every non-zero byte in the file falls inside those two records.
offset field size notes
[0] schedule flags 1 record 0 ONLY — 3 = repeat on, 2 = repeat off
[1:4] padding 3 zero in every record observed
[4] 1/2h 1 half-hour slot, 0–47
[5] Day 1 3 in every record observed — undetermined
[6] Action 1 bitmask: 2 start, 4 stop, 8 self-check, 16 ACH
[7] name length 1
[8:260] Setup name 252 null-padded; empty for actions that take no setup
⚠ [0] and [6] were mislabelled twice before a five-entry schedule
separated them — see CORRECTED below.
Decoded against the operator's own description of what they entered — "start monitoring TEST1 at 7:30 AM, Auto Call Home at 7:30 PM":
| record @0 | record @260 | |
|---|---|---|
Action |
3 | 0 |
1/2h |
15 → 07:30 ✅ | 39 → 19:30 ✅ |
Day |
3 | 3 |
[6] |
2 | 16 |
| name length | 9 | 0 |
| Setup | TEST1.mmb |
(none) ✅ |
Five independent confirmations, no fitting required:
- Slot 15 = 07:30 and slot 39 = 19:30, both matching the operator's stated times, on a 30-minute grid — and 39 − 15 = 24 slots = exactly 12 hours.
- The name-length byte reads 9 for
TEST1.mmb, 40 for the 40-character name in the read capture, and 0 for the Auto Call Home entry. - Auto Call Home carries no setup name — which is what it should do, and direct proof that a schedule entry can exist with no setup attached.
- The 260-byte stride lands the second record's
1/2hexactly at[264]. 2 × 260 + 4 = 524, the whole body, with nothing left over.
⚠ Correction: the 27 03 10 bytes at [264] were previously recorded here as
a possible trailer. They are record 2's 1/2h, Day and [6] fields. Not
a trailer — a second record hiding behind an assumption that the file held one.
Action codes, so far:
| value | action |
|---|---|
0 |
Auto Call Home |
3 |
Start monitoring, with setup |
⚠ CORRECTED — [6] is the Action, and it is a bitmask (2026-09-25)
A five-entry schedule settled this, and it overturns the two previous readings of this record. The operator's Thor screen, captured alongside:
actioncheck — Micromate — Repeat Daily: Disabled
7:30 AM Start Monitoring TEST1
8:00 AM Stop Monitoring
8:30 AM Self Check
9:00 AM Start Monitoring test2
7:30 PM Auto Call Home
Five entries, and the file holds exactly five 260-byte records:
| rec | [0] |
1/2h |
Day |
[6] |
len | name |
|---|---|---|---|---|---|---|
| @0 | 2 | 15 = 07:30 | 3 | 2 | 9 | TEST1.mmb |
| @260 | 0 | 16 = 08:00 | 3 | 4 | 0 | |
| @520 | 0 | 17 = 08:30 | 3 | 8 | 0 | |
| @780 | 0 | 18 = 09:00 | 3 | 2 | 9 | test2.mmb |
| @1040 | 0 | 39 = 19:30 | 3 | 16 | 0 |
[6] tracks the action exactly, and the values are powers of two:
[6] |
action |
|---|---|
2 |
Start Monitoring |
4 |
Stop Monitoring |
8 |
Self Check |
16 |
Auto Call Home |
Bits 1–4 of a bitmask. Bit 0 (value 1) is unobserved — a natural home for
the setup-less DUTYCYCLE_START_MONITOR, but that is a guess, not a finding.
Two retractions:
[6]was recorded as "the one unidentified field" and predicted to be the Repeat flag. It is the Action.[0]was labelled Action, then "Action with repeat folded in". Both wrong.[0]is non-zero only on record 0 — including here, where record 0 and record 3 are the same action with different[0]values. It is a schedule-level field carried in the first record, and it holds the Repeat flag:3repeat on,2repeat off, matching "Repeat Daily: Disabled" on the screen.
The earlier repeat capture was consistent with both readings because it had one start entry and changed one byte. A single-variable test is not always enough — it took a schedule with four distinct actions to separate the two fields.
Day is 3 on all five records across every capture. Still undetermined.
✅ SUB 0x47 is the scheduler enable — confirmed by Thor's own notifications
Previously recorded as "genuinely undetermined" whether 0x47 sets or reads.
Thor's notification pane timestamps it:
00:51:29 schedule write (0x8E) completes
00:51:31 Thor: "actioncheck has been successfully SENT to ... UM12947"
00:51:31 → 0x47 params[7] = 0x01
00:51:33 → 0x47 params[7] = 0x03 (on the wire as 10 03 — DLE-escaped)
00:51:35 Thor: "actioncheck was successfully ENABLED on ... UM12947"
The only frames between sent and enabled are the 0x47 pair. 0x47
performs the enable.
⚠ The meaning of params[7] ∈ {1, 3} is still open — a single 0x47 with
params[7] = 3 also appears at session start, where nothing is being enabled,
so the byte is more likely a selector than a value. Note it must be
DLE-escaped: a bare 0x03 in params truncates the frame at what the device
reads as ETX.
🔑 Setups ARE written as raw .MMB files — second retraction
This document twice stated that setups are not pushed as raw .MMB blobs and
go only through 0xDA + the config block. Wrong. In this session Thor did
both, choosing by whether the setup is the active one:
| setup | how it was written |
|---|---|
TEST1.mmb (active) |
0xDA → 0x68/0x73 → 0x82/0x83 → 0x71/0x72 |
test2.mmb (not active) |
0x8D \system\setups\test2.mmb → 0x8E (2,192 B) |
So \system\setups\<name>.mmb is the setup directory, and the generic file
transfer writes there directly.
The .MMB file is nearly the compliance block: aligning the two gives
1,968 / 2,086 bytes equal (94.3%) at a 4-byte shift. The file is 102 bytes
longer (2,192 vs 2,090) and puts the setup name at offset 38 where the 0x71
block has it at 42. So the on-disk setup and the wire compliance block are the
same structure with different framing — not two formats.
This is the cleaner path for SFM. Writing a setup as a file needs two frames
and no 0xDA/0x68/0x82 ritual, and it does not disturb the active setup.
File writes are chunked
The schedule's 1,304 bytes went as two 0x8E frames, 1,024 + 280, each with
offset = that chunk's own length. The 2,192-byte setup file went in one
frame, so 1,024 is not a hard ceiling — the chunking rule is unexplained and
recorded as observed.
Six duty-cycle actions, not five
The full _PSA() dispatch — the scheduler's own action processor, reading records
via _ReadRecord:
DUTYCYCLE_START_MONITOR ← no setup
DUTYCYCLE_START_MONITOR_WITH_SETUP
DUTYCYCLE_START_MONITOR_WITH_SETUP_STOP_COMPLETE ← a third start variant
DUTYCYCLE_STOP_MONITOR
DUTYCYCLE_CALLHOME
DUTYCYCLE_SELF_CHECK
THOR exposes four. Two start variants it never offers, one of which needs no setup file at all.
_PSA() send ->> CMD_DUTYCYCLE_START_MONITOR shows the setup-less action is live
code that the scheduler genuinely dispatches, not a dead case — it sends a real
message. And since every one of these cases sits in the function that consumes
_ReadRecord's Action field, a schedule record can carry it.
An alternative explanation was checked and ruled out: the Micromate does have a
separate Timer Mode (MODE_TIMER, MODE_MONITOR_TIMER, Monitor Once Only,
under Special Setup), so START_MONITOR could have belonged to that path
instead. It does not — it is in _PSA(), the scheduler's dispatcher.
The scheduler enable lives in SysPref, not in the setup
SysPref.bMonitorScheduler = %s
_Task() CMD_SET_SCHEDULE - MonitorScheduler ENABLED
_Task() CMD_SET_SCHEDULE - ! MonitorScheduler NOT Enabled
This confirms the failed prediction above from the other side: the
Scheduler On/Off switch is a system preference, which is why the 0x71
compliance block was byte-identical when the scheduler was turned on. It was
never going to be in there.
It also suggests 0x47 — the two bare frames at the end of the capture — is a
SysPref get/set rather than anything scheduler-specific, which would explain its
params[7] selector and its 15-byte response shape being shared with 0x48's
page-0 descriptor. ⚠ Still a hypothesis; the disable/enable capture settles it.
The schedule has a setup-less start action — Thor just never uses it
The coupling above looked like it might be a workaround for the unit crashing on a missing setup. The firmware says otherwise: there are two distinct start-monitoring actions, and only one of them involves a setup file.
_PSA() case DUTYCYCLE_START_MONITOR
_PSA() case DUTYCYCLE_START_MONITOR_WITH_SETUP
The full duty-cycle action set, from the scheduler task's own dispatch strings:
| action | notes |
|---|---|
DUTYCYCLE_START_MONITOR |
no setup involved — uses whatever config is loaded |
DUTYCYCLE_START_MONITOR_WITH_SETUP |
the variant Thor always emits |
DUTYCYCLE_STOP_MONITOR |
|
DUTYCYCLE_CALLHOME |
send ==> CMD_SCHEDULE_CALL_HOME |
DUTYCYCLE_SELF_CHECK |
call DailySelfCheck() |
DUTYCYCLE_ON / OFF / NEXT |
scheduler state, not per-entry actions |
So the schedule↔config coupling is not a crash workaround — Thor picks the more
demanding of two available actions, every time. SFM can emit
START_MONITOR and skip the config entirely.
On whether a missing setup would break the unit: the firmware suggests
graceful degradation rather than a crash — Setup File Not Found exists, and so
does Invalid parameters reset to factory default - please review setup, which
is a deliberate fallback. ⚠ Untested, and not worth relying on until it is.
⚠ Hypothesis, not a finding: the schedule entry's leading byte may be the
action code — the one captured entry reads 03 00 00 00 0f 03 02 [namelen] [name], and 03 would fit START_MONITOR_WITH_SETUP in an enum of the above.
Unverified; there is one entry and nothing to diff against.
The capture that would settle it (more valuable than the 0x47
disable/enable test): build a schedule whose entry is stop monitoring or
call home — an action with no setup attached. That would (a) confirm or kill
the action-code hypothesis, since a setup-less action should change the leading
byte and drop the name, and (b) prove from the other direction that a schedule
can be sent with no config push at all.
Note also DUTYCYCLE_CALLHOME → CMD_SCHEDULE_CALL_HOME: a scheduled
call-home is a way to make a unit dial out on demand, which is the one
remaining lever on the unsolved call-home direction.
What this implies for the build order
The read path is fully known and needs no Thor-shaped decisions, so a read-only
client can be written now with confidence. The write path should not be built
by transcribing Thor's sequence — the 0x68/0x82 question above decides
whether our setup write is 3 frames or 7, and it is answerable with one capture
plus one careful experiment.
Two reliability problems worth designing against, both observed rather than assumed:
- A zero ack does not mean a write applied. Every ack seen is 11 zero
bytes, across creates and overwrites alike, and no failing write has ever been
observed. Whatever SFM does, it should read back and compare rather than
trust the ack.
0x41+0x1Amakes that cheap. - Nothing warns before clobbering a monitoring unit's active setup. The device will not stop it and the ack will not distinguish it. That guard has to live in SFM.
⚠ Untested and unsafe-until-agreed
Nothing below has been sent to a unit by us, and nothing should be without an explicit decision.
Note the distinction introduced on 2026-09-24: the setup-write sequence
(0xDA, 0x68/0x73, 0x82/0x83, 0x71/0x72) has now been observed,
because Thor performed it while we recorded. Observed is not the same as
exercised — we have still never originated a write frame. The wire format
is known; our encoder is unwritten and unproven.
- Writes (
0x68–0x83) — format known, never sent by us - Call-home write (
0x7E/0x7F) — ✅ observed 2026-09-25, acks0x81/0x80; enable flag isolated - Per-event delete (
0xA8/0xAA) — ✅ observed 2026-09-25, acks0x57/0x55. Destructive. Series III's0xA3/0xA2erase-all has not been seen on Series IV and may not exist - Start / stop monitoring (
0x96/0x97) — observed via Thor 2026-09-24, acks0x69/0x68 - Scheduler enable (
0x47) — observed;params[7]semantics still unclear
Every one of these is now observed. None has ever been originated by us, and that is the line that still matters: the wire format is known, our encoder is unwritten and unproven.
0x1F(advance event pointer) — non-destructive on Series III but it does move device state, so it is parked with the rest
Also unknown:
-
Whether
0x10bytes inside request params need stuffing. (Write-frame data stuffing is now settled —10 XX→XX; see The write path.) -
The call-home session's bytes — the device-initiated direction has still not been observed at all, and cannot be over USB.
✅ The second half of this item is resolved (2026-09-24, from the THOR manual): "how it learns an event was accepted so it stops re-sending it" was the wrong question — it does not learn. Collection state is server-side bookkeeping and erase is a separate, optional, server-issued action. See What the THOR manual settles about the ACH session. What remains unknown is the framing of the inbound session and the erase opcodes, not any acknowledgement mechanism.
Session provenance
Unit UM12947, firmware 11.0CB (Blastware line), on the bench via
USB. Every response in this document was checksum-validated.
Three sittings, all on the same unit:
| date | state | what was exercised |
|---|---|---|
| 2026-09-23 | zero events stored | read commands, direct from Python |
| 2026-09-23 | 5 events (4 waveform, 1 histogram) | the event chain + 0x5A |
| 2026-09-24 | 5 events | Thor pushing a setup, via a recording relay |
The 2026-09-24/25 sittings used a topology worth keeping, because it is
reusable: socat on mint-mac shares /dev/ttyACM0 on TCP, seismo_lab's TCP
bridge relays Thor to it and records both directions. Thor is configured with
the unit at 127.0.0.1:<bridge port> exactly as if it were a field modem. No
modem, no SIM, and nothing on the production Thor box is touched.
Run the relay with -x and keep its log. It hex-dumps every forwarded byte
in both directions, which makes it a complete second copy of every capture,
independent of whether seismo_lab was recording:
socat -d -d -x TCP-LISTEN:12345,reuseaddr,fork /dev/ttyACM0,raw,echo=0,b115200 \
> ~/mm-captures/socat_<ts>.log 2>&1
That paid off on 2026-09-25, when a capture's .bin files never left the Windows
machine — the session was rebuilt from the relay log with
scratch/socat_log_split.py. When the real bins arrived later the
reconstruction was byte-for-byte identical in both directions (3,595 and
4,004 bytes), so the log is a validated fallback rather than an approximation.
Sessions concatenate in one log; split them on the accepting connection
markers.
⚠ Firmware is the single biggest caveat on this document. Every finding here
is from one unit on the Blastware build. A 11.0BD unit has not been
touched.
✅ The original "empty unit" limitation is gone — 0x08, 0x1E, 0x0A and
0x06 were all exercised against 5 stored events on 2026-09-23.