Series-4 write path, phase 2: encoder, opcode guard, dry run — Implementation Plan

For agentic workers: REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (- [ ]) syntax for tracking.

Goal: Build every Micromate write a later phase needs as an exact, reviewable write plan, proven byte for byte against THOR's captured frames. Make it impossible for any code path to transmit a write opcode, or 0xA2 ever, by accident. Nothing is sent to a unit.

Architecture:

  • micromate/framing.py: build_request() gains an optional data section, using the same escape set and SUM8 it already applies.
  • micromate/opcodes.py (new): one table of write SUBs and one of cross-series collisions (0xA2).
  • The send-side gate. MicromateProtocol._send() now reads each outgoing frame's SUB. It refuses any write SUB the protocol object was not explicitly allowed, and always refuses a collision. No production caller allows anything in this phase.
  • micromate/writes.py (new): pure functions that turn the unit's own reads into a WritePlan, i.e. the frames, in order, with expected acks. That plan is what each later write endpoint's dry_run=true returns.
  • A bench tool, bridges/mm_dry_run.py, does the reads on a live unit and prints the plan, sending nothing else. It is step 1 of the spec's bench protocol for every first live write.

Tech Stack: Python 3, pytest. micromate/ codec + protocol (no sfm imports).

Spec: docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md. The sections that apply are The safety layer (opcode guard), Series-4 write path (encoder, dry run, per-operation table, setup-push details), Testing (frame reproduction) and Build phases item 2.

Global Constraints

  • Nothing but reads reaches a unit. No task may construct MicromateProtocol / MicromateClient with a non-empty allowed_writes outside a test that uses a scripted transport. Task 5 (bench) sends reads only.
  • 0xA2 is never transmitted on Series 4. The collision guard refuses it even when "allowed". Lifting that needs a spec change, not a parameter.
  • A call-home plan changes exactly bit 0 of content byte [5]. Every other byte, including the unit-maintained [118:120], is echoed from the read. Never write modem baud or modem type.
  • The setup-push read-modify-write sends back only what was read. No field editing in this phase. Field encoding is phase 5.
  • Codec purity: nothing in micromate/ imports sfm. micromate/ may import minimateplus.transport only, as today.
  • Never move, rename or delete bridges/captures/, even temporarily: it holds irreplaceable research captures. Read it only.
  • Fixtures: tests/fixtures/ and bridges/captures/ are gitignored. Fixtures cut from captures go in tests/fixtures/micromate-writes/ and are force-added (git add -f). Tests that read bridges/captures/ directly must skipif when it is absent.
  • The suite's 16 pre-existing failures (test_bw_ascii_report.py 15, test_event_file_io.py 1; missing gitignored fixtures) stay exactly that set.
  • Branch feat/series4-sfm-parity.
    • Never commit to main or dev.
    • Do not edit CHANGELOG.md.
    • After each commit, run git push.
  • Hardware: only Task 5 touches /dev/ttyACM0 (UM20147), under sg dialout -c "...". Never start a server on port 8200.
  • Every commit message ends with:
    Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
    Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
    

Review Focus

These are the inputs most likely to bite, each with a test in the named task.

  1. A write opcode reaching the wire by any path. This includes _exchange, a direct _send, a scratch tool calling protocol._send, and a frame built by hand. It must be refused with nothing written to the transport (Task 2).
  2. 0xA2 in a plan or a send. It is refused even when explicitly allowed (Tasks 2, 4).
  3. A read whose block fails its CRC, or has a size THOR's offset was never observed at. Building a plan from it must be refused. Otherwise it would write corruption back, or use an unverified offset (Task 4).
  4. Escape bytes inside data, including a literal 0x10 (never captured in write data) and a checksum that lands on 02/03/04/10. The frame must still be correct (Task 1).
  5. The call-home plan must flip exactly one bit. Every other byte must equal the read (Task 4).

File map

file change
micromate/framing.py build_request(..., data=b""); new request_sub(frame)
micromate/opcodes.py new: WRITE_SUBS, CROSS_SERIES_COLLISIONS, OpcodeRefused, check_transmit()
micromate/protocol.py MicromateProtocol(allowed_writes=frozenset()); _send gate; docstring
micromate/client.py docstring only ("reads only" now enforced)
micromate/writes.py new: WriteStep, WritePlan, plan_start_monitoring, plan_stop_monitoring, plan_call_home_enabled, plan_setup_push
scratch/mm_write_fixtures.py new: cuts fixtures out of the captures (reproducible provenance)
tests/fixtures/micromate-writes/*.json new, force-added: seven captured sessions
bridges/mm_dry_run.py new: live dry run, reads only
tests test_micromate_framing.py (+), test_micromate_opcodes.py (new), test_micromate_write_fixtures.py (new), test_micromate_writes.py (new)
docs docs/micromate_protocol_reference.md, CLAUDE.md (Task 5)

Task 1: The encoder — a data section on build_request

Files:

  • Modify: micromate/framing.py, build_request (line 129)
  • Test: tests/test_micromate_framing.py (append)

Interfaces:

  • Produces:

    • build_request(sub: int, offset: int = 0, params: bytes = bytes(10), data: bytes = b"") -> bytes. The data goes after params, inside the stuffing and the checksum.
    • request_sub(frame: bytes) -> int, the SUB of a built host→unit frame. It raises ValueError on anything that isn't one.
  • Step 1: Write the failing tests. Append to tests/test_micromate_framing.py:

# ── the data section (writes) ─────────────────────────────────────────────────

from micromate.framing import request_sub, unstuff               # noqa: E402


def _destuffed_payload(frame: bytes) -> bytes:
    body = unstuff(frame[2:-1])
    return body[:-1]                       # drop the checksum byte


def test_data_goes_after_the_params_inside_the_checksum():
    data = bytes(range(0x20, 0x40))
    f = build_request(0x7E, 0x007E, bytes(10), data)
    payload = _destuffed_payload(f)
    assert payload[:6] == bytes([0x10, 0x00, 0x7E, 0x00, 0x00, 0x7E])
    assert payload[6:16] == bytes(10) and payload[16:] == data
    assert unstuff(f[2:-1])[-1] == sum(payload) & 0xFF


@pytest.mark.parametrize("b", [0x02, 0x03, 0x04, 0x10])
def test_every_escape_byte_in_data_is_escaped_on_the_wire(b):
    f = build_request(0x71, 0x082C, bytes(10), bytes([0x55, b, 0x55]))
    assert bytes([0x55, DLE, b, 0x55]) in f
    assert _destuffed_payload(f)[16:] == bytes([0x55, b, 0x55])


def test_a_literal_0x10_in_data_round_trips():
    # Never captured in write data; params already prove `10 10` (SUB 0x5A).
    data = b"\x10\x10\x00\x10"
    assert _destuffed_payload(build_request(0x71, 0x082C, bytes(10), data))[16:] == data


def test_a_checksum_that_lands_on_an_escape_byte_is_escaped():
    # Pick the last data byte so SUM8 of the payload is exactly 0x03.
    head = bytes([0x10, 0x00, 0x7E, 0x00, 0x00, 0x7E]) + bytes(10) + b"\x01\x02"
    last = (0x03 - sum(head)) & 0xFF
    f = build_request(0x7E, 0x007E, bytes(10), b"\x01\x02" + bytes([last]))
    assert f[-3:] == bytes([DLE, 0x03, ETX])


def test_without_data_the_frame_is_unchanged():
    assert build_request(0x5B, 0x0030) == build_request(0x5B, 0x0030, bytes(10), b"")


def test_request_sub_reads_the_sub_back_even_when_stuffed():
    assert request_sub(build_request(0x96, 0xFFFF)) == 0x96
    assert request_sub(build_request(0x10, 0x0000)) == 0x10       # SUB itself escaped
    assert request_sub(build_request(0x71, 0x082C, bytes(10), b"\x03" * 5)) == 0x71


@pytest.mark.parametrize("junk", [b"", b"\x41\x02\x03", b"\x02\x10\x10\x00\x96\x03", b"hello"])
def test_request_sub_refuses_anything_that_is_not_a_request_frame(junk):
    with pytest.raises(ValueError):
        request_sub(junk)


@pytest.mark.skipif(
    not _CAPTURES.is_dir(),
    reason="capture directory is gitignored; present only on a dev box",
)
def test_builder_reproduces_every_captured_request_frame_including_writes():
    """251/251: the 218 reads plus the 33 data-carrying writes."""
    checked = 0
    for path in sorted(_CAPTURES.rglob("raw_bw_*.bin")):
        blob = path.read_bytes()
        i = 0
        while i < len(blob):
            if not (blob[i] == ACK and i + 1 < len(blob) and blob[i + 1] == STX):
                i += 1
                continue
            j = i + 2
            body = bytearray()
            while j < len(blob):
                if blob[j] == DLE and j + 1 < len(blob):
                    body.append(blob[j + 1])
                    j += 2
                    continue
                if blob[j] == ETX:
                    break
                body.append(blob[j])
                j += 1
            payload = bytes(body[:-1])
            sub = payload[2]
            offset = (payload[4] << 8) | payload[5]
            assert build_request(sub, offset, payload[6:16], payload[16:]) == blob[i:j + 1], (
                f"{path.name} @0x{i:04x} SUB=0x{sub:02x}"
            )
            checked += 1
            i = j + 1
    assert checked == 251, f"expected 251 request frames, checked {checked}"
  • Step 2: Run them, and watch them fail. Run: .venv/bin/python -m pytest tests/test_micromate_framing.py -q Expected: FAIL with ImportError: cannot import name 'request_sub'.

  • Step 3: Implement. In micromate/framing.py:

    • Change the signature to def build_request(sub: int, offset: int = 0, params: bytes = bytes(10), data: bytes = b"") -> bytes:.
    • Add to its docstring's Args:
        data:   the write section after params (empty for every read and for
                write confirms).  Escaped and checksummed exactly like the rest
                of the payload -- reproduces all 33 data-carrying THOR frames.
  • Change the payload = ... line to:
    payload = (bytes([MM_CMD, 0x00, sub, 0x00, (offset >> 8) & 0xFF, offset & 0xFF])
               + params + bytes(data))
  • Add after build_request:
def request_sub(frame: bytes) -> int:
    """The SUB of a built host->unit frame (`41 02 <stuffed body> 03`).

    Used by the protocol's send-side opcode gate, which must see exactly what is
    about to go on the wire rather than trust the caller's word for it.
    """
    if len(frame) < 5 or frame[0] != ACK or frame[1] != STX or frame[-1] != ETX:
        raise ValueError(f"not a host->unit request frame: {bytes(frame[:8]).hex()}")
    body = unstuff(frame[2:-1])
    if len(body) < 17 or body[0] != MM_CMD:
        raise ValueError(f"not a host->unit request frame: {bytes(frame[:8]).hex()}")
    return body[2]
  • Step 4: Run the tests, and watch them pass. Run: .venv/bin/python -m pytest tests/test_micromate_framing.py -q Expected: all pass, including both capture-gated tests on this box (218 and 251).

  • Step 5: Commit and push. Message: feat(micromate): build_request carries a data section -- reproduces all 251 THOR request frames.


Task 2: The opcode table and the send-side gate

Files:

  • Create: micromate/opcodes.py
  • Modify: micromate/protocol.py: MicromateProtocol.__init__ (line 241), _send (line 511) and the module docstring. Also micromate/client.py, docstring line 5.
  • Test: tests/test_micromate_opcodes.py (new)

Interfaces:

  • Consumes: Task 1's request_sub.

  • Produces:

    • WRITE_SUBS: dict[int, str]
    • CROSS_SERIES_COLLISIONS: dict[int, str]
    • class OpcodeRefused(RuntimeError)
    • check_transmit(sub, allowed_writes=frozenset()) -> None
    • MicromateProtocol(transport, recv_timeout=..., strict_checksums=True, allowed_writes: frozenset = frozenset())
  • Step 1: Write the failing tests in tests/test_micromate_opcodes.py:

"""The send-side gate: no write opcode reaches the wire unless allowed, and 0xA2 never."""
from __future__ import annotations

import os
import sys

import pytest

sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))

import micromate.protocol as mm_proto                                  # noqa: E402
from micromate.framing import build_request                           # noqa: E402
from micromate.opcodes import (                                       # noqa: E402
    CROSS_SERIES_COLLISIONS, WRITE_SUBS, OpcodeRefused, check_transmit,
)
from test_micromate_protocol import frame, proto                      # noqa: E402

# THOR's captured end-call-home frame -- byte-identical to Series III's CONFIRM ERASE.
A2_WIRE = bytes.fromhex("4102101000a200ffff00000000000000000000b003")


def test_no_read_command_is_classed_as_a_write():
    reads = {v for k, v in vars(mm_proto).items() if k.startswith("SUB_")}
    assert reads and not (reads & set(WRITE_SUBS))


def test_0xa2_is_a_collision_and_a_write():
    assert 0xA2 in CROSS_SERIES_COLLISIONS and 0xA2 in WRITE_SUBS


def test_a_write_is_refused_unless_allowed():
    with pytest.raises(OpcodeRefused, match="0x96"):
        check_transmit(0x96)
    check_transmit(0x96, frozenset({0x96}))
    check_transmit(0x5B)                                   # a read needs no permission


def test_0xa2_is_refused_even_when_allowed():
    with pytest.raises(OpcodeRefused, match="ERASE"):
        check_transmit(0xA2, frozenset({0xA2}))


def test_the_protocol_refuses_a_write_and_writes_nothing():
    p, t = proto([])
    with pytest.raises(OpcodeRefused):
        p._exchange(0x96, offset=0xFFFF)
    with pytest.raises(OpcodeRefused):
        p._send(build_request(0x97, 0xFFFF))                # a direct _send is gated too
    assert t.written == []


def test_the_protocol_refuses_the_captured_0xa2_frame_byte_for_byte():
    p, t = proto([], allowed_writes=frozenset({0xA2}))
    with pytest.raises(OpcodeRefused):
        p._send(A2_WIRE)
    assert t.written == []


def test_an_explicitly_allowed_write_goes_out_on_a_scripted_transport():
    p, t = proto([frame(0x69, bytes(11))], allowed_writes=frozenset({0x96}))
    p._exchange(0x96, offset=0xFFFF)
    assert t.written == [build_request(0x96, 0xFFFF)]


def test_reads_are_unaffected_by_the_gate():
    p, t = proto([frame(0xA4, bytes(11))])
    p.poll()
    assert len(t.written) == 1


def test_a_frame_that_is_not_a_request_is_refused_not_sent():
    p, t = proto([])
    with pytest.raises(ValueError):
        p._send(b"\x41\x03")
    assert t.written == []

Before running, check tests/test_micromate_protocol.py:

  • Does proto(responses, **kw) forward **kw to MicromateProtocol?
  • Is frame(rsp_sub, data, ...) the response builder?
  • If either differs, adapt only the import lines and the call shape, and say so in the report.

Also check what POLL's response SUB is: 0xFF - 0x5B = 0xA4.

  • Step 2: Run them, and watch them fail. Run: .venv/bin/python -m pytest tests/test_micromate_opcodes.py -q Expected: FAIL with ModuleNotFoundError: No module named 'micromate.opcodes'.

  • Step 3: Implement. Create micromate/opcodes.py:

"""Micromate (Series IV) opcode table: which SUBs write, and which collide.

One place, as the parity spec requires.  `MicromateProtocol._send` consults it
on every outgoing frame, so a write cannot reach a unit by a path nobody
thought about -- a scratch tool calling `protocol._send`, a hand-built frame, a
method added later.

Every SUB here was seen as a host->unit request in THOR's captures
(`docs/micromate_protocol_reference.md`).  The table classifies REQUESTS: a few
of these values are also ACK SUBs of other commands (0x71 acks 0x8E, 0x72 acks
0x8D), which is irrelevant to a send-side check.
"""
from __future__ import annotations

from typing import Dict, FrozenSet

WRITE_SUBS: Dict[int, str] = {
    0x47: "scheduler enable/disable",
    0x68: "setup push: preferences block (0x08)",
    0x71: "setup push: setup block (0x1A)",
    0x72: "setup push: setup confirm",
    0x73: "setup push: preferences confirm",
    0x7E: "call-home config write (0x2C)",
    0x7F: "call-home config confirm",
    0x82: "setup push: trigger block (0x2E)",
    0x83: "setup push: trigger confirm",
    0x8D: "file open for write",
    0x8E: "file body write",
    0x96: "start monitoring",
    0x97: "stop monitoring",
    0xA2: "end call-home",
    0xA8: "delete one event",
    0xAA: "delete-event confirm",
    0xDA: "setup push: file name",
}

# Same bytes, opposite consequence on the other series.  Never transmitted on
# Series IV, allowed or not: if a Series-III unit is at the address (a moved
# modem, a stale IP), it would execute the other meaning.  Lifting an entry is
# a spec change, not a parameter.
CROSS_SERIES_COLLISIONS: Dict[int, str] = {
    0xA2: "CONFIRM ERASE on Series III -- erases every stored event; "
          "'end call-home' on Series IV",
}


class OpcodeRefused(RuntimeError):
    """A frame was stopped before it reached the wire."""


def check_transmit(sub: int, allowed_writes: FrozenSet[int] = frozenset()) -> None:
    if sub in CROSS_SERIES_COLLISIONS:
        raise OpcodeRefused(
            f"refused to transmit SUB 0x{sub:02X}: {CROSS_SERIES_COLLISIONS[sub]}")
    if sub in WRITE_SUBS and sub not in allowed_writes:
        raise OpcodeRefused(
            f"refused to transmit SUB 0x{sub:02X} ({WRITE_SUBS[sub]}): writes are "
            "not enabled on this connection")

In micromate/protocol.py:

  • Imports: extend from .framing import ... with request_sub, and add from .opcodes import check_transmit.
  • __init__: add the parameter allowed_writes: frozenset = frozenset(), after strict_checksums, and set self._allowed_writes = frozenset(allowed_writes) with the other assignments. Add to the docstring:
            allowed_writes: write SUBs this connection may transmit.  Empty by
                default -- every write opcode in `micromate.opcodes` is refused
                at `_send`, and `0xA2` is refused whatever this says.
  • _send:
    def _send(self, frame: bytes) -> None:
        # The gate sees the bytes that are about to go out, not the caller's
        # intent: every transmit in this package passes through here.
        check_transmit(request_sub(frame), self._allowed_writes)
        log.debug("TX %d bytes: %s", len(frame), frame.hex())
        self._transport.write(frame)
  • Module docstring: replace the paragraph that begins Scope: **reads only.** up to ...not a side effect of a client that grew a method. with:
Scope: **reads only on the wire, enforced.**  Every outgoing frame passes
`micromate.opcodes.check_transmit()` in `_send`: a write opcode is refused
unless this connection was constructed with it in `allowed_writes` (nothing in
the codebase does so yet), and `0xA2` -- CONFIRM ERASE on Series III -- is
refused always.  No command has ever been originated against a unit by this
project; every write in ``docs/micromate_protocol_reference.md`` was performed
by THOR while we recorded.  The first thing this codebase ever sends to a
customer's instrument should be a decision someone made on purpose, not a side
effect of a client that grew a method.  Write frames are *built* in
``micromate.writes`` as reviewable plans; building one sends nothing.

In micromate/client.py, change the docstring line saying reads only, at line 5, to say reads only, enforced by the protocol's opcode gate (micromate.opcodes).

  • Step 4: Run the tests, and watch them pass. Run: .venv/bin/python -m pytest tests/test_micromate_opcodes.py tests/test_micromate_protocol.py tests/test_micromate_client.py tests/test_micromate_events.py -q Expected: all pass, including the THOR replay tests on this box. If a replay test now raises OpcodeRefused, it was transmitting a captured write through the protocol. STOP and report it; do not allow writes to make it pass.

  • Step 5: Full suite. Run .venv/bin/python -m pytest -q 2>&1 | tail -3. Only the 16 pre-existing failures are allowed.

  • Step 6: Commit and push. Message: feat(micromate): one opcode table and a send-side gate -- writes refused unless allowed, 0xA2 always.


Task 3: Fixtures cut from THOR's write captures

Files:

  • Create: scratch/mm_write_fixtures.py
  • Create, force-added: tests/fixtures/micromate-writes/*.json
  • Test: tests/test_micromate_write_fixtures.py (new)

Interfaces:

  • Produces: one JSON file per captured session, in this schema:
{
  "source": "bridges/captures/9-24-26 - micromate2/<raw_bw file name>",
  "source_sha256": {"bw": "<hex>", "s3": "<hex>"},
  "unit": "UM12947",
  "firmware_line": "11.0CB",
  "exchanges": [
    {"sub": 65, "request": "<request wire hex>", "response_sub": 190, "response_data": "<response data hex>"}
  ]
}

The sessions and their slugs:

slug capture (under bridges/captures/9-24-26 - micromate2/)
setup-push-new-test1 raw_{bw,s3}_20260924_181942_send_TEST1_to_unit.bin
setup-push-overwrite-test1 overwritetest/raw_{bw,s3}_20260924_185113_test1_overwrite_check.bin
setup-push-read-scheduler raw_{bw,s3}_20260924_191835_read_scheduler.bin
setup-push-pull-schedule raw_{bw,s3}_20260925_003029_pull_schedule,_turn_off_repeat_daily,_push_schedule.bin
setup-push-multiday raw_{bw,s3}_20260925_011907_send_multiday_schedule.bin
call-home-enable-disable raw_{bw,s3}_20260925_011620_ACH-change_1_setting.bin
monitor-start-stop raw_{bw,s3}_20260924_191214_turn_on_monitormode_then_attempt_to_write_config.bin
  • Step 1: Write the extraction script scratch/mm_write_fixtures.py:
#!/usr/bin/env python3
"""Cut Micromate write-session fixtures out of THOR's captures.

bridges/captures/ is gitignored, so the reproduction tests read these instead.
Each fixture is every request (as wire bytes) and every response (as its data
section) of one captured THOR session, paired in order, with the sha256 of the
capture files it came from.  Re-run to regenerate:

    .venv/bin/python scratch/mm_write_fixtures.py
"""
from __future__ import annotations

import hashlib
import json
import sys
from pathlib import Path

REPO = Path(__file__).resolve().parent.parent
sys.path.insert(0, str(REPO))

from micromate.framing import ACK, DLE, ETX, STX, MicromateFrameParser  # noqa: E402

CAP = REPO / "bridges" / "captures" / "9-24-26 - micromate2"
OUT = REPO / "tests" / "fixtures" / "micromate-writes"
SESSIONS = {
    "setup-push-new-test1": "20260924_181942_send_TEST1_to_unit",
    "setup-push-overwrite-test1": "overwritetest/*20260924_185113_test1_overwrite_check",
    "setup-push-read-scheduler": "20260924_191835_read_scheduler",
    "setup-push-pull-schedule": "20260925_003029_pull_schedule,_turn_off_repeat_daily,_push_schedule",
    "setup-push-multiday": "20260925_011907_send_multiday_schedule",
    "call-home-enable-disable": "20260925_011620_ACH-change_1_setting",
    "monitor-start-stop": "20260924_191214_turn_on_monitormode_then_attempt_to_write_config",
}


def _find(stem: str, kind: str) -> Path:
    if "/" in stem:
        sub, rest = stem.split("/", 1)
        hits = sorted((CAP / sub).glob(f"raw_{kind}_{rest.lstrip('*')}.bin"))
    else:
        hits = sorted(CAP.glob(f"raw_{kind}_{stem}.bin"))
    if len(hits) != 1:
        raise SystemExit(f"expected one raw_{kind} file for {stem!r}, found {hits}")
    return hits[0]


def requests(blob: bytes) -> list[bytes]:
    out, i = [], 0
    while i < len(blob):
        if not (blob[i] == ACK and i + 1 < len(blob) and blob[i + 1] == STX):
            i += 1
            continue
        j = i + 2
        while j < len(blob):
            if blob[j] == DLE and j + 1 < len(blob):
                j += 2
                continue
            if blob[j] == ETX:
                break
            j += 1
        out.append(blob[i:j + 1])
        i = j + 1
    return out


def main() -> None:
    OUT.mkdir(parents=True, exist_ok=True)
    for slug, stem in SESSIONS.items():
        bw, s3 = _find(stem, "bw"), _find(stem, "s3")
        reqs = requests(bw.read_bytes())
        parser = MicromateFrameParser()
        rsps = parser.feed(s3.read_bytes())
        if len(reqs) != len(rsps):
            raise SystemExit(f"{slug}: {len(reqs)} requests vs {len(rsps)} responses")
        exchanges = []
        for rq, rp in zip(reqs, rsps):
            from micromate.framing import request_sub
            sub = request_sub(rq)
            if rp.sub != 0xFF - sub or not rp.checksum_valid:
                raise SystemExit(f"{slug}: response 0x{rp.sub:02X} does not answer 0x{sub:02X}")
            exchanges.append({"sub": sub, "request": rq.hex(), "response_sub": rp.sub,
                              "response_data": rp.data.hex()})
        doc = {
            "source": str(bw.relative_to(REPO)),
            "source_sha256": {"bw": hashlib.sha256(bw.read_bytes()).hexdigest(),
                              "s3": hashlib.sha256(s3.read_bytes()).hexdigest()},
            "unit": "UM12947", "firmware_line": "11.0CB",
            "exchanges": exchanges,
        }
        (OUT / f"{slug}.json").write_text(json.dumps(doc, indent=1) + "\n")
        print(f"{slug}: {len(exchanges)} exchanges")


if __name__ == "__main__":
    main()

Check two things before running:

  • MicromateFrameParser().feed() returns a list of MicromateFrame with .sub, .data and .checksum_valid (micromate/framing.py).
  • Responses index-align with requests. The survey measured equal counts in every pair; the script refuses otherwise.

Move the request_sub import to the top imports. It is shown inline above only for clarity.

  • Step 2: Run it. .venv/bin/python scratch/mm_write_fixtures.py. Expect 7 lines, one per slug. Check the count for each kind of session:

    • setup push: 12 to 25 exchanges;
    • call-home: 14;
    • start/stop: about 40.

    If any session fails alignment, STOP and report it.

  • Step 3: Write the tests in tests/test_micromate_write_fixtures.py:

"""The write-session fixtures are what they claim to be: THOR's own frames, paired."""
from __future__ import annotations

import json
import os
import sys
from pathlib import Path

import pytest

sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))

from micromate.framing import request_sub, unstuff                   # noqa: E402

FIX = Path(__file__).parent / "fixtures" / "micromate-writes"
ALL = sorted(FIX.glob("*.json"))


def test_all_seven_sessions_are_present():
    assert {p.stem for p in ALL} == {
        "setup-push-new-test1", "setup-push-overwrite-test1", "setup-push-read-scheduler",
        "setup-push-pull-schedule", "setup-push-multiday", "call-home-enable-disable",
        "monitor-start-stop"}


@pytest.mark.parametrize("path", ALL, ids=lambda p: p.stem)
def test_every_request_is_a_valid_frame_and_every_response_answers_it(path):
    doc = json.loads(path.read_text())
    assert doc["source_sha256"]["bw"] and doc["exchanges"]
    for ex in doc["exchanges"]:
        wire = bytes.fromhex(ex["request"])
        assert request_sub(wire) == ex["sub"]
        body = unstuff(wire[2:-1])
        assert body[-1] == sum(body[:-1]) & 0xFF            # plain SUM8
        assert ex["response_sub"] == 0xFF - ex["sub"]


@pytest.mark.parametrize("slug,subs", [
    ("setup-push-new-test1", [0x41, 0x08, 0x2E, 0x1A, 0xDA, 0x68, 0x73, 0x82, 0x83, 0x71, 0x72]),
    ("call-home-enable-disable", [0x2C, 0x7E, 0x7F]),
    ("monitor-start-stop", [0x96, 0x97]),
])
def test_each_session_holds_the_frames_its_tests_need(slug, subs):
    seen = [ex["sub"] for ex in json.loads((FIX / f"{slug}.json").read_text())["exchanges"]]
    for s in subs:
        assert s in seen, f"{slug}: no SUB 0x{s:02X}"
  • Step 4: Run the tests and watch them pass. Run: .venv/bin/python -m pytest tests/test_micromate_write_fixtures.py -q. To show the fixtures stand alone, check that neither the fixture tests nor Task 4's tests reference the capture directory: grep -n "captures" tests/test_micromate_write_fixtures.py must print nothing. ⚠ Never move, rename or delete bridges/captures/, not even temporarily. It holds irreplaceable research captures.

  • Step 5: Commit and push. Use git add -f tests/fixtures/micromate-writes/*.json and git add scratch/mm_write_fixtures.py tests/test_micromate_write_fixtures.py. Message: test(micromate): THOR's write sessions as fixtures -- seven captures, paired, with provenance.


Task 4: Write plans, reproduced byte for byte

Files:

  • Create: micromate/writes.py
  • Test: tests/test_micromate_writes.py (new)

Interfaces:

  • Consumes:

    • Task 1's build_request(data=);
    • Task 2's WRITE_SUBS, CROSS_SERIES_COLLISIONS and OpcodeRefused;
    • micromate.setup_block.crc_ok;
    • Task 3's fixtures.
  • Produces:

    • WriteStep(sub, offset, data=b"", params=bytes(10), what="") with .ack_sub, .frame and .describe();
    • WritePlan(action, steps) with .subs, .frames() and .describe();
    • plan_start_monitoring(), plan_stop_monitoring();
    • plan_call_home_enabled(call_home: bytes, enabled: bool);
    • plan_setup_push(prefs: bytes, trigger: bytes, setup: bytes, name: str).

    All inputs are block content: response data [11:].

  • Step 1: Write the failing tests in tests/test_micromate_writes.py:

"""Write plans: built from the unit's own reads, equal to THOR's frames byte for byte."""
from __future__ import annotations

import json
import os
import sys
from pathlib import Path

import pytest

sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))

from micromate.opcodes import OpcodeRefused                                    # noqa: E402
from micromate.writes import (                                                 # noqa: E402
    WritePlan, WriteStep, plan_call_home_enabled, plan_setup_push,
    plan_start_monitoring, plan_stop_monitoring,
)

FIX = Path(__file__).parent / "fixtures" / "micromate-writes"
PUSHES = ["setup-push-new-test1", "setup-push-overwrite-test1", "setup-push-read-scheduler",
          "setup-push-pull-schedule", "setup-push-multiday"]
NO_EDIT_PUSHES = ["setup-push-read-scheduler", "setup-push-pull-schedule", "setup-push-multiday"]


def _session(slug):
    return json.loads((FIX / f"{slug}.json").read_text())["exchanges"]


def _content(ex):
    return bytes.fromhex(ex["response_data"])[11:]


def _first_push(slug):
    """The reads (by SUB) and THOR's writes (by SUB) of the session's first push."""
    ex = _session(slug)
    start = next(i for i, e in enumerate(ex) if e["sub"] == 0xDA)
    reads = {}
    for e in ex[:start]:
        reads[e["sub"]] = _content(e)          # the LAST read of each SUB before the push
    writes = {}
    for e in ex[start:]:
        if e["sub"] in writes:
            break
        writes[e["sub"]] = bytes.fromhex(e["request"])
        if e["sub"] == 0x72:
            break
    return reads, writes


def _name_from_active(content):
    # Mirror how MicromateClient.get_active_setup() extracts the name from the
    # 0x41 content -- check it and copy its slicing if the name does not start
    # at content[0].
    return content.split(b"\x00", 1)[0].decode("ascii")


# ── start / stop ──────────────────────────────────────────────────────────────

def test_start_and_stop_equal_thors_frames():
    thor = {e["sub"]: bytes.fromhex(e["request"]) for e in _session("monitor-start-stop")
            if e["sub"] in (0x96, 0x97)}
    assert plan_start_monitoring().frames() == [thor[0x96]]
    assert plan_stop_monitoring().frames() == [thor[0x97]]
    assert thor[0x96].hex() == "41021010009600ffff00000000000000000000a403"


# ── call-home ─────────────────────────────────────────────────────────────────

def test_call_home_enable_then_disable_equal_thors_frames():
    ex = _session("call-home-enable-disable")
    pairs, last_read = [], None
    for e in ex:
        if e["sub"] == 0x2C:
            last_read = _content(e)
        elif e["sub"] == 0x7E:
            pairs.append((last_read, bytes.fromhex(e["request"])))
    confirms = [bytes.fromhex(e["request"]) for e in ex if e["sub"] == 0x7F]
    assert len(pairs) == 2 and len(confirms) == 2
    (r1, w1), (r2, w2) = pairs
    on, off = plan_call_home_enabled(r1, True), plan_call_home_enabled(r2, False)
    assert on.frames() == [w1, confirms[0]]
    assert off.frames() == [w2, confirms[1]]


def test_call_home_flips_exactly_one_bit_and_echoes_everything_else():
    r1 = next(_content(e) for e in _session("call-home-enable-disable") if e["sub"] == 0x2C)
    for enabled in (True, False):
        data = plan_call_home_enabled(r1, enabled).steps[0].data
        diff = [i for i in range(len(r1)) if data[i] != r1[i]]
        assert set(diff) <= {5}
        assert data[5] & 0x01 == (1 if enabled else 0)
        assert data[5] & 0xFE == r1[5] & 0xFE
        assert data[118:120] == r1[118:120]


def test_call_home_refuses_an_unobserved_size():
    with pytest.raises(ValueError, match="126"):
        plan_call_home_enabled(bytes(125), True)


# ── setup push ────────────────────────────────────────────────────────────────

@pytest.mark.parametrize("slug", PUSHES)
def test_setup_push_name_prefs_trigger_and_confirms_equal_thors_frames(slug):
    reads, thor = _first_push(slug)
    name = ("TEST1.mmb" if slug == "setup-push-new-test1"
            else _name_from_active(reads[0x41]))
    plan = plan_setup_push(reads[0x08], reads[0x2E], reads[0x1A], name)
    ours = {s.sub: s.frame for s in plan.steps}
    for sub in (0xDA, 0x68, 0x73, 0x82, 0x83, 0x72):
        assert ours[sub] == thor[sub], f"{slug}: SUB 0x{sub:02X}"
    assert [s.sub for s in plan.steps] == [0xDA, 0x68, 0x73, 0x82, 0x83, 0x71, 0x72]


@pytest.mark.parametrize("slug", NO_EDIT_PUSHES)
def test_a_no_edit_push_reproduces_thors_setup_block_frame(slug):
    reads, thor = _first_push(slug)
    plan = plan_setup_push(reads[0x08], reads[0x2E], reads[0x1A], _name_from_active(reads[0x41]))
    assert next(s.frame for s in plan.steps if s.sub == 0x71) == thor[0x71]


def test_setup_push_refuses_a_read_that_fails_its_checksum():
    reads, _ = _first_push("setup-push-multiday")
    bad = bytearray(reads[0x1A])
    bad[100] ^= 0xFF
    with pytest.raises(ValueError, match="checksum"):
        plan_setup_push(reads[0x08], reads[0x2E], bytes(bad), "x.mmb")


@pytest.mark.parametrize("which", ["prefs", "trigger", "setup"])
def test_setup_push_refuses_an_unobserved_block_size(which):
    reads, _ = _first_push("setup-push-multiday")
    args = {"prefs": reads[0x08], "trigger": reads[0x2E], "setup": reads[0x1A]}
    args[which] = args[which] + b"\x00\x00"
    with pytest.raises(ValueError, match="size"):
        plan_setup_push(args["prefs"], args["trigger"], args["setup"], "x.mmb")


@pytest.mark.parametrize("name", ["", "a\x00b", "é.mmb", "x" * 256])
def test_setup_push_refuses_a_bad_name(name):
    reads, _ = _first_push("setup-push-multiday")
    with pytest.raises(ValueError):
        plan_setup_push(reads[0x08], reads[0x2E], reads[0x1A], name)


# ── the plan object ───────────────────────────────────────────────────────────

def test_a_plan_cannot_hold_a_collision_opcode():
    with pytest.raises(OpcodeRefused):
        WritePlan("end call-home", (WriteStep(0xA2, 0xFFFF),))


def test_a_plan_cannot_hold_a_read():
    with pytest.raises(ValueError):
        WritePlan("poll", (WriteStep(0x5B, 0x0030),))


def test_describe_is_the_dry_run_shape():
    d = plan_stop_monitoring().describe()
    assert d["action"] == "stop monitoring" and d["sends_nothing"] is True
    step = d["steps"][0]
    assert step == {"sub": "0x97", "what": "stop monitoring", "offset": "0xFFFF",
                    "data_len": 0, "expect_ack": "0x68",
                    "frame": "41021010009700ffff00000000000000000000a503"}
  • Step 2: Run them, and watch them fail. Run: .venv/bin/python -m pytest tests/test_micromate_writes.py -q Expected: FAIL with ModuleNotFoundError: No module named 'micromate.writes'.

  • Step 3: Implement micromate/writes.py:

"""Write plans for a Micromate: the exact frames a write would send, in order.

A plan is what a dry run returns.  Building one sends nothing; transmitting it
also needs a protocol constructed with those SUBs in `allowed_writes`, which no
code does yet (see `micromate.opcodes`).

Every input is the unit's OWN read of the block being written (content, i.e.
response data[11:]), and every plan sends back exactly what was read except
the one thing the operation changes.  THOR works the same way, and the
reproduction tests hold the plans to THOR's frames byte for byte.

Offsets are THOR's observed constants.  🔶 Each was seen at one block size
only, so a plan refuses a block of any other size rather than guess.
"""
from __future__ import annotations

from dataclasses import dataclass, field
from typing import FrozenSet, List, Tuple

from .framing import build_request
from .opcodes import CROSS_SERIES_COLLISIONS, WRITE_SUBS, OpcodeRefused
from .setup_block import crc_ok

_CONFIRM = 0xFFFF

# block content sizes THOR's offsets were observed at (all on UM12947 / 11.0CB)
_PREFS_LEN, _TRIGGER_LEN, _SETUP_LEN, _CALL_HOME_LEN = 90, 28, 2092, 126
_NAME_FIELD = 256


@dataclass(frozen=True)
class WriteStep:
    sub: int
    offset: int
    data: bytes = b""
    params: bytes = field(default=bytes(10))
    what: str = ""

    @property
    def ack_sub(self) -> int:
        return 0xFF - self.sub

    @property
    def frame(self) -> bytes:
        return build_request(self.sub, self.offset, self.params, self.data)

    def describe(self) -> dict:
        return {"sub": f"0x{self.sub:02X}", "what": self.what,
                "offset": f"0x{self.offset:04X}", "data_len": len(self.data),
                "expect_ack": f"0x{self.ack_sub:02X}", "frame": self.frame.hex()}


@dataclass(frozen=True)
class WritePlan:
    action: str
    steps: Tuple[WriteStep, ...]

    def __post_init__(self) -> None:
        for s in self.steps:
            if s.sub in CROSS_SERIES_COLLISIONS:
                raise OpcodeRefused(
                    f"a plan cannot hold SUB 0x{s.sub:02X}: {CROSS_SERIES_COLLISIONS[s.sub]}")
            if s.sub not in WRITE_SUBS:
                raise ValueError(f"SUB 0x{s.sub:02X} is not a write opcode")

    @property
    def subs(self) -> FrozenSet[int]:
        return frozenset(s.sub for s in self.steps)

    def frames(self) -> List[bytes]:
        return [s.frame for s in self.steps]

    def describe(self) -> dict:
        return {"action": self.action, "sends_nothing": True,
                "steps": [s.describe() for s in self.steps]}


def plan_start_monitoring() -> WritePlan:
    return WritePlan("start monitoring", (WriteStep(0x96, _CONFIRM, what="start monitoring"),))


def plan_stop_monitoring() -> WritePlan:
    return WritePlan("stop monitoring", (WriteStep(0x97, _CONFIRM, what="stop monitoring"),))


def plan_call_home_enabled(call_home: bytes, enabled: bool) -> WritePlan:
    """Read `0x2C`, flip bit 0 of content[5], send the rest back byte for byte.

    `[5]` reads 0x05 enabled / 0x04 disabled; bit 2 is set in both, so only
    bit 0 is the enable.  `[118:120]` is unit-maintained and THOR echoes it.
    """
    if len(call_home) != _CALL_HOME_LEN:
        raise ValueError(f"call-home content must be {_CALL_HOME_LEN} B "
                         f"(the size THOR's offset was seen at), got {len(call_home)}")
    b5 = (call_home[5] | 0x01) if enabled else (call_home[5] & 0xFE)
    data = call_home[:5] + bytes([b5]) + call_home[6:]
    what = "call-home " + ("enable" if enabled else "disable")
    return WritePlan(what, (
        WriteStep(0x7E, 0x007E, data, what="call-home config write"),
        WriteStep(0x7F, _CONFIRM, what="call-home config confirm"),
    ))


def _checked(block: bytes, size: int, label: str) -> bytes:
    if len(block) != size:
        raise ValueError(f"{label} block size {len(block)} B is not the {size} B "
                         "THOR's offset was observed at -- refusing to guess")
    if not crc_ok(block):
        raise ValueError(f"{label} block failed its checksum -- refusing to write a "
                         "corrupt read back to the unit")
    return block


def plan_setup_push(prefs: bytes, trigger: bytes, setup: bytes, name: str) -> WritePlan:
    """Rewrite a setup as THOR does: read 0x08, 0x2E, 0x1A, send each back.

    No field editing here (phase 5).  Each block goes back with its length echo
    [0:3] zeroed; the unit recomputes the CRCs, so 0x68 and 0x71 drop the CRC
    slot and 0x82 sends it zeroed -- exactly THOR's frames.
    """
    _checked(prefs, _PREFS_LEN, "preferences (0x08)")
    _checked(trigger, _TRIGGER_LEN, "trigger (0x2E)")
    _checked(setup, _SETUP_LEN, "setup (0x1A)")
    try:
        raw = name.encode("ascii")
    except UnicodeEncodeError:
        raise ValueError(f"setup name must be ASCII: {name!r}") from None
    if not raw or b"\x00" in raw or len(raw) >= _NAME_FIELD:
        raise ValueError(f"setup name must be 1-{_NAME_FIELD - 1} ASCII bytes "
                         f"with no NUL: {name!r}")
    return WritePlan(f"setup push: {name}", (
        WriteStep(0xDA, 0x0100, raw.ljust(_NAME_FIELD, b"\x00"), what="setup file name"),
        WriteStep(0x68, 0x005A, bytes(3) + prefs[3:88], what="preferences block"),
        WriteStep(0x73, _CONFIRM, what="preferences confirm"),
        WriteStep(0x82, 0x001C, bytes(3) + trigger[3:26] + bytes(2), what="trigger block"),
        WriteStep(0x83, _CONFIRM, what="trigger confirm"),
        WriteStep(0x71, 0x082C, bytes(3) + setup[3:2090], what="setup block"),
        WriteStep(0x72, _CONFIRM, what="setup confirm"),
    ))

If a reproduction assertion fails, do NOT adjust the builder to match one capture. Report the exact byte difference. The builder rules come from the survey's measured diffs (0x68 = 0x08 content[0:88] with [0:3] zeroed; 0x82 = 0x2E content[0:28] with [0:3] and [26:28] zeroed; 0x71 = 0x1A content[0:2090] with [0:3] zeroed; 0xDA = the name, null-padded to 256). A mismatch means a rule is wrong, and that is a finding.

  • Step 4: Run the tests, and watch them pass. Run: .venv/bin/python -m pytest tests/test_micromate_writes.py -q Expected: all pass.

  • Step 5: Run the full suite. Only the 16 pre-existing failures are allowed.

  • Step 6: Commit and push. Message: feat(micromate): write plans for start/stop, call-home and setup push -- THOR's frames byte for byte.


Task 5: The dry-run bench tool, run on UM20147

Files:

  • Create: bridges/mm_dry_run.py
  • Modify: docs/micromate_protocol_reference.md, CLAUDE.md

Read-only on the unit. UM20147 is on /dev/ttyACM0, which needs sg dialout -c "...".

  • Step 1: Write the tool bridges/mm_dry_run.py:
#!/usr/bin/env python3
"""Dry run a Micromate write against a live unit: do the reads, print the plan.

Sends READS only.  The write frames are built from the unit's own blocks and
printed for review -- step 1 of the bench protocol for every first live write
(parity spec, Testing).  The protocol's opcode gate refuses every write SUB on
this connection, so nothing else can go out even by mistake.

    sg dialout -c ".venv/bin/python bridges/mm_dry_run.py /dev/ttyACM0 call-home-off"
    .venv/bin/python bridges/mm_dry_run.py --host 10.0.0.5 --tcp-port 9034 setup-rewrite
"""
from __future__ import annotations

import argparse
import json
import sys
from pathlib import Path

sys.path.insert(0, str(Path(__file__).resolve().parent.parent))

from micromate.client import MicromateClient                         # noqa: E402
from micromate.writes import (                                        # noqa: E402
    plan_call_home_enabled, plan_setup_push, plan_start_monitoring, plan_stop_monitoring,
)
from minimateplus.transport import SerialTransport, TcpTransport      # noqa: E402

ACTIONS = ("start", "stop", "call-home-on", "call-home-off", "setup-rewrite")


def _content(data: bytes) -> bytes:
    return bytes(data)[11:]


def main() -> int:
    ap = argparse.ArgumentParser(description=__doc__.splitlines()[0])
    ap.add_argument("port", nargs="?", help="serial port, e.g. /dev/ttyACM0")
    ap.add_argument("action", choices=ACTIONS)
    ap.add_argument("--host")
    ap.add_argument("--tcp-port", type=int, default=9034)
    ap.add_argument("--baud", type=int, default=115200)
    a = ap.parse_args()
    if not (a.port or a.host):
        ap.error("give a serial port or --host")
    transport = TcpTransport(a.host, port=a.tcp_port) if a.host else SerialTransport(a.port, a.baud)
    mm = MicromateClient(transport)
    mm.open()
    try:
        info = mm.connect()
        p = mm.protocol
        if a.action == "start":
            plan = plan_start_monitoring()
        elif a.action == "stop":
            plan = plan_stop_monitoring()
        elif a.action.startswith("call-home"):
            plan = plan_call_home_enabled(_content(p.read_call_home_config()),
                                          a.action == "call-home-on")
        else:
            name = mm.get_active_setup()
            plan = plan_setup_push(_content(p.read_event_index()), _content(p.read_trigger_config()),
                                   _content(p.read_compliance_config()), name)
        out = plan.describe()
        out["unit"] = {"serial": info.serial, "firmware_line": info.firmware_line}
        print(json.dumps(out, indent=1))
    finally:
        mm.close()
    return 0


if __name__ == "__main__":
    sys.exit(main())

Before running, check the real names and return types of these:

  • MicromateProtocol.read_call_home_config, read_event_index (the 0x08 preferences block), read_trigger_config and read_compliance_config. Do they return the response data or a frame?
  • MicromateClient.get_active_setup(). Does it return the file name string, e.g. "test2.MMB"?

Adapt _content() and the calls to the real API. Mention any adaptation in the report.

  • Step 2: Run it on UM20147, one action at a time. Run each as its own command, under sg dialout:

    • start
    • stop
    • call-home-on
    • call-home-off
    • setup-rewrite

    Save each output to <scratchpad>/dryrun/<action>.json. The scratchpad is /tmp/claude-1000/-home-serversdown-seismo-relay/fc1049ca-ccbd-41ba-ac35-6b7c3996ffcd/scratchpad.

    Expected for every action:

    • JSON with sends_nothing: true and the planned frames.
    • No OpcodeRefused traceback. The tool only calls reads; a traceback would mean a write was attempted, which is a bug to report.

    If a setup or call-home block is not the observed size on this unit's firmware (11.0BD), the plan is refused with a size error. Record that. It is a finding: THOR's offsets would then be unverified on this firmware. Do not change the size table.

  • Step 3: Compare with THOR's frames (UM12947, 11.0CB, from the fixtures). For each action, tabulate SUB order, offsets and data lengths, ours against THOR's. They should match exactly; only data content differs, since it is the unit's own blocks.

    • Also confirm the setup-rewrite plan's 0x71 data equals the unit's 0x1A content [3:2090] with three zero bytes in front. That is a no-edit rewrite.
    • For call-home-off / call-home-on, also confirm exactly one byte ([5]) differs between the two plans' 0x7E data.
  • Step 4: Record.

    • In docs/micromate_protocol_reference.md, near the setup-push and call-home write sections, add a dated, graded line: "2026-10-22 — UM20147 (11.0BD) block sizes equal UM12947's (11.0CB): …; so THOR's write offsets apply to both firmware lines as far as size goes (measured, one unit each; nothing sent)". Use whatever was actually measured.
    • In CLAUDE.md, add a sentence in the Series-4 "Where things stand" area:
      • Phase 2 is done: the write encoder, the opcode gate and write plans.
      • It covers start/stop, call-home and the setup rewrite, reproduced byte for byte against THOR (counts).
      • bridges/mm_dry_run.py prints a write's planned frames from a live unit's reads.
      • The protocol's _send gate refuses every write opcode unless explicitly allowed, and 0xA2 always.
      • "No command has ever been originated against a unit by this project" is still true, and is now enforced in code.
  • Step 5: Commit and push the tool and both docs. Message: feat(bridges): mm_dry_run -- a write's planned frames from a live unit's reads; bench-checked on UM20147.


Self-review notes

  • Spec coverage:
    • Encoder: Task 1.
    • Opcode guard (one table; 0xA2): Task 2.
    • Dry run: Task 4 (WritePlan.describe()) and Task 5 (live). The write endpoints' dry_run=true parameter arrives with each write in phases 3–5 and returns describe().
    • Frame reproduction for 0x96/0x97, 0x7E/0x7F and the full setup push: Tasks 1, 3 and 4. The 0x71 edit pushes reproduce everything but 0x71, because field editing is phase 5.
    • Fixtures force-added: Task 3.
  • Not in phase 2:
    • Any transmit of a write.
    • The identity check, audit table and read-back framework (phase 3).
    • Field encoding (phase 5).
    • Per-event delete. It is destructive tier; its SUBs are in the opcode table only.
    • Scheduler 0x47 and file 0x8D/0x8E (table only).
  • Never captured, and so only synthetic:
    • A checksum on an escape byte.
    • A literal 0x10 in data.
    • Start or stop when the unit is already in that state.
    • Any write on 11.0BD.