Brian's method, and better than v2's whole-record median: the pre-trigger
window is definitionally quiet (the buffer captured before the trigger fired),
whereas a median is merely robust to the event. Requiring the floor to hold
across pre-trigger / middle / end rejects transients that a median cannot.
per channel: pre/mid/end medians, spread = max - min
offset when |pre| >= floor AND spread <= 0.02 in/s
real fault >= 3 consecutive flagged events on that channel
The empirical noise floor justifies the threshold and validates the decoder:
across 19,244 non-flagged channel-events the pre-trigger floor is 62.7% exactly
0.000, 94.5% within +/-1 quantisation unit, median +0.0000, mean -0.0008. There
is no systematic zero-point bias — an independent confirmation of the
32000-count geo scale.
The result is threshold-insensitive across a 2x range (0.020 to 0.040 in/s),
which is what separates a real signal from a tuned one:
FINAL: 5 of 45 units (11%) — BE9558, BE11529, BE12599, BE13117, BE18438
BE11007 and BE10895 drop out; the spread test identifies them as transients
rather than pedestals. v1's 11% headline was right by luck — it included
BE11007 and named the wrong channel on most units.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog