Files
seismo-relay/docs
serversdownandClaude Opus 5.5 b6e726f850 docs: the event-file fields SFM reads from the file alone (reference Appendix D.6)
New Appendix D.6 records the bytes and DL2 verification for every field
SFM reads from a Blastware event file: record type STRT[18], the
recording-setup block (sample rate k-42, pre-trigger k-36, record time
k-30, the four notes), the geophone range (label+29), each histogram
interval's PVS^2, and the mic scale (0.25 Pa per count, dB offset
81.9384).  None of these were written down outside code and issues.

Retracted in place:
- D.3.1's STRT[20] = record time: it is 00 on 70,041 / 70,041 DL2 files.
- the 2026-08-26 reading of sub-minute histogram records as little-
  endian: big-endian from byte 5 since v0.32.0 (#47/#49), and the
  '2-word tail' is the PVS^2.  Also in CLAUDE.md.

Measured for #48 (files only): the 1A 'stable anchor' be 80 00 00 00 00
is the setup's pre-trigger -0.25 s plus 00 00.  It is present only on
the 3,886 / 6,541 DL2 waveforms recorded at exactly -0.25 s, and on no
histogram.  The live 1A read is still unmeasured.

CLAUDE.md: Where things stand reflects the range fix on dev (6,524 /
6,524 waveforms exact); the 8x sensitive-range item and the MicL dB
item are marked resolved in place.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-02 14:03:47 -05:00
..
2026-02-24 21:19:40 +00:00