Files
seismo-relay/sfm/device_access/s3.py
T
serversdownandClaude Opus 5.5 b6ed5f5bd5 feat(sfm): SFM's MiniMate files carry the W/H type letter Blastware's direct downloads leave off
Blastware names a direct download K441LTON.900 and only its call-in copy
K441LTON.900H, so a folder of directly downloaded events cannot be sorted by
kind.  SFM's own files now always carry the letter.  It is read from the file's
own record-type byte (STRT[18], #41) by the new with_type_letter() -- not from
the recording mode: BE9441's K441LTOK.R10 is a waveform that triggered 2 s into
histogram K441LTOK.QZ0 (Histogram+Continuous).  A file whose type does not read
keeps the plain name; a name never fails a download.

All three paths that name a MiniMate file SFM builds: the device-access
download (the page's event list), WaveformStore.save (the legacy route's store
copy, the bench call-in server), and the legacy /device/event/{i}/blastware_file
download.  Verified on BE9441's recorded 5A walk: 0111f210 -> K441LTON.900H,
011106a0 -> K441LTOK.R10W, byte-identical to Blastware's files.

find_event_by_blastware_name tightens with it: a lettered name matches itself
and the letterless form, not the other letter (a waveform and a histogram in the
same second are different events); a letterless name still matches all three.

Store consequence: new downloads only; rows and files stored before keep their
names, and 'already stored' still finds them.  No schema change, no migration.
The event list shows the plain name until the event is downloaded (the type is
not known before the 5A).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-30 00:36:26 -04:00

420 lines
21 KiB
Python

"""Series-3 adapter. Connect-per-request, as SFM has always done for
MiniMates -- a held session waits for the bench test in the spec."""
from __future__ import annotations
import datetime
import logging
import struct
from typing import Any, Callable, Optional
from minimateplus import MiniMateClient
from minimateplus.blastware_file import blastware_file_bytes, blastware_filename, with_type_letter
from minimateplus.event_file_io import _GEO_INT16_FS
from minimateplus.framing import build_bw_write_frame
from minimateplus.protocol import SUB_START_MONITORING, SUB_STOP_MONITORING
from minimateplus.transport import TcpTransport
from .errors import DeviceError, EventNotFound, MalformedReply, NoAnswer, StaleEvent, WrongUnit, translate
from .change import run_change
from .events import iso_of, make_event_id, stamp_of
from .models import ChangeResult, DownloadedEvent, EventList, EventRef, UnitAddress, UnitInfo, UnitSettings, UnitStatus
log = logging.getLogger("sfm.device_access")
S3_DEFAULT_BAUD = 38400
S3_MODES = {0x00: "Single Shot", 0x01: "Continuous", 0x03: "Histogram", 0x04: "Histogram + Continuous"}
S3_EVENT_TIMEOUT = 120.0 # what the legacy event-download routes use
# The 0x1C flag byte (section[1]): the only values ever measured. 0x10 is
# BE11529 monitoring (2026-04-08); 0x0B is BE9441 recording a histogram,
# confirmed at the unit (2026-10-26). Anything else is refused for a change.
S3_RUN_STATES = {0x00: "idle", 0x10: "monitoring", 0x0B: "monitoring"}
def s3_run_state(status: Any) -> str:
"""The change path's state name from the raw 0x1C flag -- never
`is_monitoring`, which reads every byte but 0x10 as idle. A value never
measured is `unknown(0x..)`, and the change core refuses it."""
flag = getattr(status, "state_flag", None)
if flag is None:
return "unknown(short)"
return S3_RUN_STATES.get(flag, f"unknown(0x{flag:02X})")
# A start makes the unit run its sensor check before "Recording..." -- ~30 s
# (Brian, 2026-10-26), ~40 s on BE11529 (2026-04-08). A start's read-back waits
# this long before asking, then wakes the unit with retries (S3_WAKE_*).
S3_SENSOR_CHECK_S = 30.0
S3_WAKE_ATTEMPT_S = 5.0
S3_WAKE_DEADLINE_S = 60.0
def _woken_state(client: Any) -> str:
"""The run state, read after waking the unit: SESSION_RESET + POLL first,
re-sent until it answers.
A monitoring MiniMate ignores a bare request until it is woken (measured
2026-04-08). On 2026-10-26 BE9441 acked a start, then left a bare 0x1C, and
later a single SESSION_RESET + POLL, unanswered for 120 s: both went out 2 s
after the start, inside the sensor check, and were never re-sent."""
client.wake(attempt_s=S3_WAKE_ATTEMPT_S, deadline_s=S3_WAKE_DEADLINE_S)
return s3_run_state(client.get_monitor_status())
def default_s3_client_factory(address: UnitAddress, timeout: Optional[float] = None) -> MiniMateClient:
if address.host:
return MiniMateClient(transport=TcpTransport(address.host, port=address.tcp_port),
timeout=10.0 if timeout is None else timeout)
if timeout is None:
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD)
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD, timeout=timeout)
def _close(client: Any) -> None:
try:
client.close()
except Exception: # noqa: BLE001
log.debug("close failed", exc_info=True)
def _s3_dt(ev: Any) -> Optional[datetime.datetime]:
ts = getattr(ev, "timestamp", None)
if ts is None or ts.hour is None:
return None
try:
return datetime.datetime(ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second)
except (TypeError, ValueError):
return None
def _s3_filename(ev: Any, serial: str) -> Optional[str]:
try:
return blastware_filename(ev, serial)
except Exception: # noqa: BLE001
return None
S3_RECORD_TYPE_NOTE = "Series 3's event record does not say waveform or histogram; not decoded yet"
def _s3_ref(ev: Any, serial: str) -> EventRef:
"""record_type is always None: minimateplus's 0C decode reports "Waveform"
for every record layout, histograms included, so it cannot be trusted
here. Null rather than wrong until a histogram's 0C is captured."""
dt = _s3_dt(ev)
pv = ev.peak_values
peaks = {}
if pv is not None:
peaks = {k: v for k, v in (("tran", pv.tran), ("vert", pv.vert), ("long", pv.long))
if v is not None}
return EventRef(
event_id=make_event_id(serial, ev._waveform_key, stamp_of(dt)),
serial=serial, series=3, index=ev.index, timestamp=iso_of(dt),
record_type=None,
peak_vector_sum_ips=pv.peak_vector_sum if pv is not None else None,
peaks_ips=peaks, filename=_s3_filename(ev, serial),
detail={"mic_psi": pv.micl if pv is not None else None,
"record_type_note": S3_RECORD_TYPE_NOTE},
)
_GEO_FULL_SCALE_IPS = 10.0 # normal range; one decoder step = 0.005 in/s
_PEAK_TOLERANCE_IPS = 0.0051 # one 0.005 in/s step, plus the 0C's float32 slop
def verify_s3_download(ev: Any, compliance: Any, body: Optional[bytes] = None) -> tuple:
"""Check a downloaded event against itself and the unit's own 0C record: (verified, why).
A short or misassembled event must not reach the store -- BE9441's bench
(2026-10-25) stored two as successes before this existed. `body` is the
event's 5A body (taken from `ev._a5_frames` when not given). In order:
* No waveform decode: it must decode as a histogram (stored unverified --
its peaks are not compared yet), or it is refused. 0 of ~430 fixture
histograms decode as a waveform; a corrupted waveform decodes as neither.
* A waveform's record chain must end on its END record (0x06), as the
file reader requires; a cut-short stream does not.
* All three geophone channels must be the same length.
* Each channel's peak must be the unit's own to one 0.005 in/s step (a
clipped blast -- both at full scale -- counts as a match). Only for a
unit confirmed in normal range: a sensitive-range unit's scale is still
open (the 8x discrepancy), and an unread range is not assumed.
Raises MalformedReply ("not saved") on any failure.
"""
from minimateplus.blastware_file import extract_body_bytes
from minimateplus.histogram_codec import decode_histogram_body
from minimateplus.waveform_codec import STREAM_END_ID, walk_records
if body is None:
frames = getattr(ev, "_a5_frames", None)
body = extract_body_bytes(frames)[1] if frames else b""
samples = getattr(ev, "raw_samples", None) or {}
chans = ("Tran", "Vert", "Long")
if not all(samples.get(c) for c in chans):
if body and decode_histogram_body(body):
return None, "a histogram: stored unverified (its peaks are not compared yet)"
raise MalformedReply(
"the downloaded event decodes as neither a waveform nor a histogram -- the "
"download is incomplete or misassembled; not saved")
try:
recs = walk_records(body)
except Exception: # noqa: BLE001 -- treated as no chain
recs = []
tail = recs[-1]["end"] if recs else None
if tail is None or tail + 5 > len(body) or body[tail + 4] != STREAM_END_ID:
raise MalformedReply(
"the downloaded waveform's record chain has no end record -- the download is "
"cut short; not saved")
lengths = {c: len(samples[c]) for c in chans}
if len(set(lengths.values())) != 1:
raise MalformedReply(
f"the downloaded waveform's channels have different lengths {lengths} -- the "
"download is incomplete or misassembled; not saved")
if getattr(compliance, "geo_range", None) != 0:
return None, ("whole, but peaks not checked: the unit is not confirmed in normal "
"range (a sensitive-range scale is not settled)")
pv = ev.peak_values
unit = {"Tran": pv.tran, "Vert": pv.vert, "Long": pv.long} if pv else {}
clip = _GEO_FULL_SCALE_IPS - _PEAK_TOLERANCE_IPS
for c in chans:
if unit.get(c) is None:
return None, f"whole, but the unit's record gives no {c} peak to check against"
decoded = max(abs(x) for x in samples[c]) * _GEO_FULL_SCALE_IPS / _GEO_INT16_FS
if decoded >= clip and unit[c] >= clip:
continue # both at full scale: a clipped blast
if abs(decoded - unit[c]) > _PEAK_TOLERANCE_IPS:
raise MalformedReply(
f"the downloaded {c} peak is {decoded:.4f} in/s but the unit's own record says "
f"{unit[c]:.4f} -- the download is incomplete or misassembled; not saved")
return True, f"{lengths['Tran']} samples per channel, peaks match the unit's own"
class Series3Adapter:
def __init__(self, client_factory: Callable[..., Any] = default_s3_client_factory) -> None:
self._factory = client_factory
def change_monitoring(self, address: UnitAddress, serial: str, *, start: bool, dry_run: bool,
even_if_already: bool, audit: Any, caller: str,
sleep: Callable[[float], None], verify_timeout_s: float,
verify_interval_s: float) -> ChangeResult:
"""Series-3 pieces for the shared core in change.py. One attempt, never
retried: `retry=False` stops _run's cold-boot second attempt, and the
core calls the write once."""
sub = SUB_START_MONITORING if start else SUB_STOP_MONITORING
ack_sub = 0xFF - sub
def op(client: Any) -> ChangeResult:
def read_serial() -> str:
info = client.connect() # a fresh connection: connect() is the fresh 0x15 read
return info.serial or ""
def describe_plan() -> dict:
what = "start monitoring" if start else "stop monitoring"
return {"action": what, "sends_nothing": True, "warnings": [],
"steps": [{"sub": f"0x{sub:02X}", "what": what, "offset": "0x0000",
"data_len": 0, "expect_ack": f"0x{ack_sub:02X}",
"frame": build_bw_write_frame(sub, b"").hex()}]}
settle: list = []
def send() -> dict:
# The client validates the ack SUB; it returns nothing else, so none is claimed.
(client.start_monitoring if start else client.stop_monitoring)()
if start:
settle.append(S3_SENSOR_CHECK_S) # the first read waits out the check
return {"subs": [f"0x{ack_sub:02X}"]}
reconnected: list = []
def read_state() -> str:
if settle:
sleep(settle.pop())
try:
return _woken_state(client)
except OSError as exc:
# The modem can drop the line while the unit sensor-checks
# after a start: BE9441's first wake hit "[Errno 32] Broken
# pipe" (2026-10-29), and a fresh connection read it as
# monitoring. Reconnect once, TCP only (opening a MiniMate's
# serial port reboots it), check it is still the same unit,
# and read. A read -- nothing is re-sent.
if reconnected or not address.host:
raise
reconnected.append(True)
log.warning("Series 3 at %s: the line dropped during the read-back (%s) -- "
"reconnecting to read the state; nothing is re-sent",
address.key, exc)
client.close()
client.open()
# Wake first: the identity read is a bare 0x15, which a unit that
# has just started ignores until SESSION_RESET + POLL (the order
# the status read and the legacy write routes use: poll, then read).
client.wake(attempt_s=S3_WAKE_ATTEMPT_S, deadline_s=S3_WAKE_DEADLINE_S)
self._check(client.read_serial(), serial, address)
return s3_run_state(client.get_monitor_status())
return run_change(
serial=serial, series=3, start=start, dry_run=dry_run,
even_if_already=even_if_already, audit=audit, address=address, caller=caller,
sleep=sleep, verify_timeout_s=verify_timeout_s, verify_interval_s=verify_interval_s,
read_serial=read_serial,
read_state=read_state,
describe_plan=describe_plan, send=send)
return self._run(address, op, timeout=S3_EVENT_TIMEOUT, retry=False)
def _run(self, address: UnitAddress, fn: Callable[[Any], Any], timeout: Optional[float] = None,
retry: bool = True) -> Any:
def attempt() -> Any:
client = self._factory(address) if timeout is None else self._factory(address, timeout=timeout)
try:
client.open()
except Exception as exc:
_close(client)
raise translate(exc, connecting=True) from exc
try:
return fn(client)
except DeviceError:
raise
except Exception as exc:
raise translate(exc, connecting=False) from exc
finally:
_close(client)
try:
return attempt()
except NoAnswer:
# A MiniMate that has just had its serial lines asserted can take
# 5-10 s to boot, and shows it as silence; one retry covers it. TCP
# only -- on a serial cable a silence is a real fault. Narrower than
# server._run_with_retry (any protocol error): retrying a
# MalformedReply would also retry "no settings block", which a
# reconnect cannot fix.
if not retry or not address.host:
raise
log.info("Series 3 at %s: no clean answer, retrying once (unit may be cold)", address.key)
return attempt()
@staticmethod
def _check(serial_reported: str, serial: str, address: UnitAddress) -> None:
if (serial_reported or "").strip().upper() != serial:
raise WrongUnit(f"asked for {serial} but {serial_reported} answered at {address.key}")
def identify(self, address: UnitAddress, serial: str) -> UnitInfo:
def op(client: Any) -> UnitInfo:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
return UnitInfo(
serial=info.serial, series=3, model=info.model, firmware=info.firmware_version,
monitoring=None, active_setup=cc.setup_name if cc else None,
detail={"manufacturer": info.manufacturer, "dsp_version": info.dsp_version},
)
return self._run(address, op)
def status(self, address: UnitAddress, serial: str) -> UnitStatus:
def op(client: Any) -> UnitStatus:
client.poll()
ms = client.get_monitor_status()
# The change path's reading, not a guess: an unmeasured flag is None.
monitoring = {"monitoring": True, "idle": False}.get(s3_run_state(ms))
return UnitStatus(
serial=serial, series=3, monitoring=monitoring,
battery_volts=round(ms.battery_v, 2) if ms.battery_v is not None else None,
memory_total_bytes=ms.memory_total, memory_free_bytes=ms.memory_free,
device_time=None, event_count=None,
# Series 3 status reads no serial, so the serial shown is the one requested, not one the unit reported.
detail={"serial_verified": False},
)
return self._run(address, op)
def settings(self, address: UnitAddress, serial: str) -> UnitSettings:
def op(client: Any) -> UnitSettings:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
if cc is None:
raise MalformedReply("could not read the unit's settings (SUB 0x1A)")
mode = None
if cc.recording_mode is not None:
mode = S3_MODES.get(cc.recording_mode, f"unknown (0x{cc.recording_mode:02x})")
notes = {
label: value for label, value in (
("Project", cc.project), ("Client", cc.client), ("User Name", cc.operator),
("Seis Loc", cc.sensor_location), ("Extended Notes", cc.notes),
) if value is not None
}
return UnitSettings(
serial=info.serial, series=3, setup_name=cc.setup_name, record_mode=mode,
sample_rate=cc.sample_rate, record_time_s=cc.record_time,
histogram_interval_s=cc.histogram_interval_sec, geo_trigger_ips=cc.trigger_level_geo,
notes=notes,
detail={"record_mode_code": cc.recording_mode, "alarm_level_geo": cc.alarm_level_geo,
"geo_range": cc.geo_range},
)
return self._run(address, op)
def list_events(self, address: UnitAddress, serial: str) -> EventList:
def op(client: Any) -> EventList:
info = client.connect()
self._check(info.serial, serial, address)
return EventList(serial=serial, series=3,
events=[_s3_ref(ev, serial) for ev in client.list_event_headers()])
# The default timeout: a header walk is small replies only, so a lost
# one costs 10 s (TCP) with the unit locked, not 120 s.
return self._run(address, op)
def download_event(self, address: UnitAddress, serial: str, key: bytes,
stamp: Optional[str]) -> DownloadedEvent:
# The walk compares this with the target's 0C and, on a mismatch, sends
# no 5A: a stale id costs a header walk, not a full download of the
# wrong event.
iso = datetime.datetime.strptime(stamp, "%Y%m%d%H%M%S").isoformat() if stamp is not None else None
def op(client: Any) -> DownloadedEvent:
info = client.connect()
self._check(info.serial, serial, address)
try:
ev = client.download_event_by_key(key, expected_timestamp=iso)
except struct.error as exc:
# Defensive. This once caught the 64 KB page bug (TERM's offset driven
# negative); the walk is 32-bit linear since 2026-10-26 and no longer
# produces it, so reaching here is a new fault.
raise MalformedReply(
f"event {key.hex()}: its download could not be assembled ({exc}); not saved"
) from exc
if ev is None:
raise EventNotFound(f"no event {key.hex()} on {serial} -- list the events again")
found = stamp_of(_s3_dt(ev))
if stamp is not None and found is None:
raise MalformedReply(
f"could not read event {key.hex()}'s record (0C) to confirm it is the one "
"listed -- not downloaded; try again")
if stamp is not None and found != stamp:
raise StaleEvent(
f"the event at {key.hex()} on {serial} is from {found}, not {stamp} -- "
"the unit was erased or wrapped since the list was read; list again")
if not ev._a5_frames:
raise MalformedReply(f"event {key.hex()}: no waveform data received (the 5A download failed)")
filename = _s3_filename(ev, serial)
if filename is None:
raise MalformedReply(f"event {key.hex()} has no usable timestamp, so it cannot be named or stored")
verified, why = verify_s3_download(ev, info.compliance_config)
try:
bw_bytes = blastware_file_bytes(ev, ev._a5_frames)
except ValueError as exc:
raise MalformedReply(
f"event {key.hex()}: its Blastware file could not be assembled ({exc}); not saved"
) from exc
filename = with_type_letter(filename, bw_bytes) # ...900 -> ...900H, from the file's own bytes
return DownloadedEvent(
event_id=make_event_id(serial, key, found), serial=serial, series=3,
filename=filename, verified=verified, event=ev, a5_frames=ev._a5_frames,
bw_bytes=bw_bytes,
compliance=info.compliance_config, timestamp=_s3_dt(ev),
detail={"a5_frames": len(ev._a5_frames), "check": why},
)
return self._run(address, op, timeout=S3_EVENT_TIMEOUT)