Files
seismo-relay/docs
serversdownandClaude Opus 5 b9c52442a7 docs(series4): the Series III behaviour is firmware-conditional
The bench unit reports 11.0CB -- Instantel's *Blastware* firmware line. It
almost certainly answers Series III commands because it is in Blastware mode,
not because the Micromate natively speaks Series III. Instantel ships two
lines: 11.0CB (Blastware) and 11.0BD (THOR, Vision, Vision II).

That also explains the two-ACH-server problem as designed behaviour rather
than misconfiguration.

Corpus firmware audit: 932 event files from 11.0AK, 83 from 10.90GC. UM12947
itself produced 10.90GC files in production last year and reports 11.0CB now,
so units get reflashed and firmware is not stable per-unit over time.

Records the resulting strategic fork (standardise on the Blastware line vs
reverse-engineer the Thor line) with the four unknowns that decide it.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-23 16:04:42 -04:00
..
2026-02-24 21:19:40 +00:00