serversdownandClaude Opus 5.5 cdc6360ec0 fix(sfm): an audit finish that fails on a hang-up path still releases the line
The final fix wave's AuditIncomplete landed in _exchange's `except DeviceError`,
which keeps the line -- so on the nine ring / link-fault paths (and a refusal) a
failed audit write turned a hang-up into a held Series-4 line, blocking a THOR
call-home for up to the 5-minute idle hang-up and making "SFM hung up" false.
AuditIncomplete now carries release_line, set by every finish whose path hangs
up anyway, and _exchange honours it.  Also pins the Series-3 change path's
retry=False again (the rewritten lost-ack test no longer could).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 19:36:00 -04:00

117 lines
3.4 KiB
Python

"""Typed device errors, each with the HTTP status the endpoints return."""
from __future__ import annotations
import micromate.protocol as _mm_proto
import minimateplus.protocol as _mmp_proto
class DeviceError(Exception):
http_status = 500
class BadRequest(DeviceError):
http_status = 422
class NotSupported(DeviceError):
http_status = 501
class WrongUnit(DeviceError):
http_status = 409
class UnitStateUnknown(DeviceError):
"""The unit reports a run state that has never been measured."""
http_status = 409
class AuditUnavailable(DeviceError):
"""The audit row could not be written, so nothing was sent."""
http_status = 503
class AuditIncomplete(DeviceError):
"""The unit was dealt with, but its audit row could not be finished. The
message says what happened to the unit first, then names the row.
`release_line` is True when the path would have hung up had the finish
worked (a ring, a link fault, a refusal): the failed write to the audit log
must not turn that into a held line, which would block a call-home."""
http_status = 500
def __init__(self, message: str, *, release_line: bool = False) -> None:
super().__init__(message)
self.release_line = release_line
class ChangeUnconfirmed(DeviceError):
"""A change failed after its frame went out, or may have gone out.
`sent` is "acknowledged" (the ack came back; the read-back failed) or
"unknown" (the ack was lost, or a call-home took its place). The status is
the one the cause would have had, set per instance, and the message names
the audit record. It never means "nothing was sent".
"""
http_status = 500
def __init__(self, message: str, *, audit_id: str, sent: str, http_status: int) -> None:
if sent not in ("acknowledged", "unknown"):
raise ValueError(f"sent must be 'acknowledged' or 'unknown', not {sent!r}")
super().__init__(message)
self.audit_id = audit_id
self.sent = sent
self.http_status = http_status
class UnitBusy(DeviceError):
http_status = 423
class ConnectFailed(DeviceError):
http_status = 503
class CallHomeInProgress(DeviceError):
http_status = 503
class NoAnswer(DeviceError):
http_status = 504
class MalformedReply(DeviceError):
http_status = 502
class EventNotFound(DeviceError):
http_status = 404
class StaleEvent(DeviceError):
"""The event at that key is not the one listed -- the unit was erased, or
its memory wrapped, since the list was read."""
http_status = 409
_TIMEOUTS = (_mm_proto.TimeoutError, _mmp_proto.TimeoutError)
_PROTOCOL = (_mm_proto.ProtocolError, _mmp_proto.ProtocolError)
def translate(exc: BaseException, *, connecting: bool) -> DeviceError:
"""Map a library exception to a typed error.
Order matters: each library's TimeoutError is a ProtocolError subclass, and
the builtin TimeoutError (a failed TCP connect) is an OSError.
"""
if isinstance(exc, DeviceError):
return exc
if isinstance(exc, _TIMEOUTS):
return NoAnswer(f"the unit did not answer: {exc}")
if isinstance(exc, _PROTOCOL):
return MalformedReply(f"bad reply from the unit: {exc}")
if isinstance(exc, OSError):
what = "could not connect" if connecting else "connection lost"
return ConnectFailed(f"{what}: {exc}")
return DeviceError(f"device error: {exc}")