Files
seismo-relay/sfm/device_access/s3.py
T
serversdownandClaude Opus 5.5 8f68b09f5e fix(sfm): a change that fails after the send says so; the audit row records sent + states; S3 unknown states refused
Final fix wave for phase 3 (start/stop monitoring), per the whole-phase review.

- I1 + M2: every failure after the send has started is a ChangeUnconfirmed
  (audit_id, sent = "acknowledged" | "unknown", the cause's HTTP status) whose
  message says the frame was sent and names the audit record -- the ring in
  place of the ack, the four lost-ack follow-ups, and the three read-back
  paths.  Series4Session releases the line on it.  Every audit finish goes
  through one helper; a finish that fails is AuditIncomplete (500) and still
  says what happened to the unit.  The line is kept.
- I2: device_commands gains `sent` (1 acknowledged, 0 nothing sent, NULL
  unknown) and `states` (before / seen / after), with an idempotent ADD COLUMN
  in _migrate for a table created earlier on this branch.
- M1: a RADIO RING already buffered is caught before 0x96/0x97 goes out
  (pre_send = read_unsolicited, one 10 ms transport read).  That is a
  CallHomeInProgress with sent=0, not ChangeUnconfirmed.
- M3: Series 3 reads the raw 0x1C flag (new MonitorStatus.state_flag); a byte
  other than 0x00/0x10, or a short section, is unknown(...) and refused.
- M8: even_if_already on a unit already in the state notes that the read-back
  proves nothing.
- M10: a scan pins `.protocol.execute(` to sfm/device_access/s4.py; both
  scans fail closed on a file that does not parse.
- M11: docs corrected (CLAUDE.md phase-2 sentence, phase-3 bullet, REST list;
  micromate/protocol.py scope and the 0x49 read_state docstring; s4.py; route
  docstrings).  "No command has ever been originated" is NOT retracted.
- M12: GET /db/device_commands normalises the serial.
- Minors: unused imports, S3 dry-run frames and 120 s timeout pinned, test
  rename, serial-cache and short-0x49 tests, _RUN_STATES comment.

Schema: two NULLable columns on the branch-new device_commands table, added
by _migrate on open; no backfill.  No codec change, TOOL_VERSION unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 19:16:45 -04:00

282 lines
13 KiB
Python

"""Series-3 adapter. Connect-per-request, as SFM has always done for
MiniMates -- a held session waits for the bench test in the spec."""
from __future__ import annotations
import datetime
import logging
import struct
from typing import Any, Callable, Optional
from minimateplus import MiniMateClient
from minimateplus.blastware_file import blastware_filename
from minimateplus.framing import build_bw_write_frame
from minimateplus.protocol import SUB_START_MONITORING, SUB_STOP_MONITORING
from minimateplus.transport import TcpTransport
from .errors import DeviceError, EventNotFound, MalformedReply, NoAnswer, StaleEvent, WrongUnit, translate
from .change import run_change
from .events import iso_of, make_event_id, stamp_of
from .models import ChangeResult, DownloadedEvent, EventList, EventRef, UnitAddress, UnitInfo, UnitSettings, UnitStatus
log = logging.getLogger("sfm.device_access")
S3_DEFAULT_BAUD = 38400
S3_MODES = {0x00: "Single Shot", 0x01: "Continuous", 0x03: "Histogram", 0x04: "Histogram + Continuous"}
S3_EVENT_TIMEOUT = 120.0 # what the legacy event-download routes use
# The 0x1C flag byte (section[1]): the only two values ever measured.
S3_RUN_STATES = {0x00: "idle", 0x10: "monitoring"}
def s3_run_state(status: Any) -> str:
"""The change path's state name from the raw 0x1C flag -- never
`is_monitoring`, which reads every byte but 0x10 as idle. A value never
measured is `unknown(0x..)`, and the change core refuses it."""
flag = getattr(status, "state_flag", None)
if flag is None:
return "unknown(short)"
return S3_RUN_STATES.get(flag, f"unknown(0x{flag:02X})")
def default_s3_client_factory(address: UnitAddress, timeout: Optional[float] = None) -> MiniMateClient:
if address.host:
return MiniMateClient(transport=TcpTransport(address.host, port=address.tcp_port),
timeout=10.0 if timeout is None else timeout)
if timeout is None:
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD)
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD, timeout=timeout)
def _close(client: Any) -> None:
try:
client.close()
except Exception: # noqa: BLE001
log.debug("close failed", exc_info=True)
def _s3_dt(ev: Any) -> Optional[datetime.datetime]:
ts = getattr(ev, "timestamp", None)
if ts is None or ts.hour is None:
return None
try:
return datetime.datetime(ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second)
except (TypeError, ValueError):
return None
def _s3_filename(ev: Any, serial: str) -> Optional[str]:
try:
return blastware_filename(ev, serial)
except Exception: # noqa: BLE001
return None
S3_RECORD_TYPE_NOTE = "Series 3's event record does not say waveform or histogram; not decoded yet"
def _s3_ref(ev: Any, serial: str) -> EventRef:
"""record_type is always None: minimateplus's 0C decode reports "Waveform"
for every record layout, histograms included, so it cannot be trusted
here. Null rather than wrong until a histogram's 0C is captured."""
dt = _s3_dt(ev)
pv = ev.peak_values
peaks = {}
if pv is not None:
peaks = {k: v for k, v in (("tran", pv.tran), ("vert", pv.vert), ("long", pv.long))
if v is not None}
return EventRef(
event_id=make_event_id(serial, ev._waveform_key, stamp_of(dt)),
serial=serial, series=3, index=ev.index, timestamp=iso_of(dt),
record_type=None,
peak_vector_sum_ips=pv.peak_vector_sum if pv is not None else None,
peaks_ips=peaks, filename=_s3_filename(ev, serial),
detail={"mic_psi": pv.micl if pv is not None else None,
"record_type_note": S3_RECORD_TYPE_NOTE},
)
class Series3Adapter:
def __init__(self, client_factory: Callable[..., Any] = default_s3_client_factory) -> None:
self._factory = client_factory
def change_monitoring(self, address: UnitAddress, serial: str, *, start: bool, dry_run: bool,
even_if_already: bool, audit: Any, caller: str,
sleep: Callable[[float], None], verify_timeout_s: float,
verify_interval_s: float) -> ChangeResult:
"""Series-3 pieces for the shared core in change.py. One attempt, never
retried: `retry=False` stops _run's cold-boot second attempt, and the
core calls the write once."""
sub = SUB_START_MONITORING if start else SUB_STOP_MONITORING
ack_sub = 0xFF - sub
def op(client: Any) -> ChangeResult:
def read_serial() -> str:
info = client.connect() # a fresh connection: connect() is the fresh 0x15 read
return info.serial or ""
def describe_plan() -> dict:
what = "start monitoring" if start else "stop monitoring"
return {"action": what, "sends_nothing": True, "warnings": [],
"steps": [{"sub": f"0x{sub:02X}", "what": what, "offset": "0x0000",
"data_len": 0, "expect_ack": f"0x{ack_sub:02X}",
"frame": build_bw_write_frame(sub, b"").hex()}]}
def send() -> dict:
# The client validates the ack SUB; it returns nothing else, so none is claimed.
(client.start_monitoring if start else client.stop_monitoring)()
return {"subs": [f"0x{ack_sub:02X}"]}
return run_change(
serial=serial, series=3, start=start, dry_run=dry_run,
even_if_already=even_if_already, audit=audit, address=address, caller=caller,
sleep=sleep, verify_timeout_s=verify_timeout_s, verify_interval_s=verify_interval_s,
read_serial=read_serial,
read_state=lambda: s3_run_state(client.get_monitor_status()),
describe_plan=describe_plan, send=send)
return self._run(address, op, timeout=S3_EVENT_TIMEOUT, retry=False)
def _run(self, address: UnitAddress, fn: Callable[[Any], Any], timeout: Optional[float] = None,
retry: bool = True) -> Any:
def attempt() -> Any:
client = self._factory(address) if timeout is None else self._factory(address, timeout=timeout)
try:
client.open()
except Exception as exc:
_close(client)
raise translate(exc, connecting=True) from exc
try:
return fn(client)
except DeviceError:
raise
except Exception as exc:
raise translate(exc, connecting=False) from exc
finally:
_close(client)
try:
return attempt()
except NoAnswer:
# A MiniMate that has just had its serial lines asserted can take
# 5-10 s to boot, and shows it as silence; one retry covers it. TCP
# only -- on a serial cable a silence is a real fault. Narrower than
# server._run_with_retry (any protocol error): retrying a
# MalformedReply would also retry "no settings block", which a
# reconnect cannot fix.
if not retry or not address.host:
raise
log.info("Series 3 at %s: no clean answer, retrying once (unit may be cold)", address.key)
return attempt()
@staticmethod
def _check(serial_reported: str, serial: str, address: UnitAddress) -> None:
if (serial_reported or "").strip().upper() != serial:
raise WrongUnit(f"asked for {serial} but {serial_reported} answered at {address.key}")
def identify(self, address: UnitAddress, serial: str) -> UnitInfo:
def op(client: Any) -> UnitInfo:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
return UnitInfo(
serial=info.serial, series=3, model=info.model, firmware=info.firmware_version,
monitoring=None, active_setup=cc.setup_name if cc else None,
detail={"manufacturer": info.manufacturer, "dsp_version": info.dsp_version},
)
return self._run(address, op)
def status(self, address: UnitAddress, serial: str) -> UnitStatus:
def op(client: Any) -> UnitStatus:
client.poll()
ms = client.get_monitor_status()
return UnitStatus(
serial=serial, series=3, monitoring=ms.is_monitoring,
battery_volts=round(ms.battery_v, 2) if ms.battery_v is not None else None,
memory_total_bytes=ms.memory_total, memory_free_bytes=ms.memory_free,
device_time=None, event_count=None,
# Series 3 status reads no serial, so the serial shown is the one requested, not one the unit reported.
detail={"serial_verified": False},
)
return self._run(address, op)
def settings(self, address: UnitAddress, serial: str) -> UnitSettings:
def op(client: Any) -> UnitSettings:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
if cc is None:
raise MalformedReply("could not read the unit's settings (SUB 0x1A)")
mode = None
if cc.recording_mode is not None:
mode = S3_MODES.get(cc.recording_mode, f"unknown (0x{cc.recording_mode:02x})")
notes = {
label: value for label, value in (
("Project", cc.project), ("Client", cc.client), ("User Name", cc.operator),
("Seis Loc", cc.sensor_location), ("Extended Notes", cc.notes),
) if value is not None
}
return UnitSettings(
serial=info.serial, series=3, setup_name=cc.setup_name, record_mode=mode,
sample_rate=cc.sample_rate, record_time_s=cc.record_time,
histogram_interval_s=cc.histogram_interval_sec, geo_trigger_ips=cc.trigger_level_geo,
notes=notes,
detail={"record_mode_code": cc.recording_mode, "alarm_level_geo": cc.alarm_level_geo,
"geo_range": cc.geo_range},
)
return self._run(address, op)
def list_events(self, address: UnitAddress, serial: str) -> EventList:
def op(client: Any) -> EventList:
info = client.connect()
self._check(info.serial, serial, address)
return EventList(serial=serial, series=3,
events=[_s3_ref(ev, serial) for ev in client.list_event_headers()])
# The default timeout: a header walk is small replies only, so a lost
# one costs 10 s (TCP) with the unit locked, not 120 s.
return self._run(address, op)
def download_event(self, address: UnitAddress, serial: str, key: bytes,
stamp: Optional[str]) -> DownloadedEvent:
# The walk compares this with the target's 0C and, on a mismatch, sends
# no 5A: a stale id costs a header walk, not a full download of the
# wrong event.
iso = datetime.datetime.strptime(stamp, "%Y%m%d%H%M%S").isoformat() if stamp is not None else None
def op(client: Any) -> DownloadedEvent:
info = client.connect()
self._check(info.serial, serial, address)
try:
ev = client.download_event_by_key(key, expected_timestamp=iso)
except struct.error as exc:
# Inferred, not measured here: the known 5A page bug. An event past the unit's
# first 64 KB drives TERM's offset negative, and struct.pack rejects it
# (seismo-relay CLAUDE.md, "KNOWN BUG").
raise MalformedReply(
f"event {key.hex()}: its download could not be assembled ({exc}) -- most "
"likely the known bug with events past the unit's first 64 KB; not saved"
) from exc
if ev is None:
raise EventNotFound(f"no event {key.hex()} on {serial} -- list the events again")
found = stamp_of(_s3_dt(ev))
if stamp is not None and found is None:
raise MalformedReply(
f"could not read event {key.hex()}'s record (0C) to confirm it is the one "
"listed -- not downloaded; try again")
if stamp is not None and found != stamp:
raise StaleEvent(
f"the event at {key.hex()} on {serial} is from {found}, not {stamp} -- "
"the unit was erased or wrapped since the list was read; list again")
if not ev._a5_frames:
raise MalformedReply(f"event {key.hex()}: no waveform data received (the 5A download failed)")
filename = _s3_filename(ev, serial)
if filename is None:
raise MalformedReply(f"event {key.hex()} has no usable timestamp, so it cannot be named or stored")
return DownloadedEvent(
event_id=make_event_id(serial, key, found), serial=serial, series=3,
filename=filename, verified=None, event=ev, a5_frames=ev._a5_frames,
compliance=info.compliance_config, timestamp=_s3_dt(ev),
detail={"a5_frames": len(ev._a5_frames)},
)
return self._run(address, op, timeout=S3_EVENT_TIMEOUT)