Files
seismo-relay/minimateplus/decode_check_carveouts.py
T
serversdownandClaude Opus 5.5 e25784d9db feat(decode): over range inside a histogram's intervals, as in the event
Inside an interval the rule is the event's: a peak past 2,000 units
(the mic in counts) is Blastware's OORANGE, and the interval's vector
sum is OORANGE when any geophone is.  DL2 (2026-11-09): numeric up to
1,846 (geophones) / 1,414 (mic), OORANGE from 2,001; vector sums 16 / 16
OORANGE with a geophone over, 2,862 / 2,862 numeric without.

event_file_io.over_full_scale(count, channel); the checker renders those
interval cells as OORANGE.  The saturation carve-out compares SFM's own
words properly (_differs): an OORANGE from SFM never counts as
saturation, and an OORANGE equal to Blastware's is not a difference.
Its interval tests run on the numeric values it used to see.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-09 13:35:08 -05:00

160 lines
7.3 KiB
Python

"""
minimateplus/decode_check_carveouts.py — the proven ways Blastware's report
differs from the instrument's data.
Every disagreement between SFM and Blastware is SFM's bug until shown otherwise.
A carve-out is that showing: the fields it covers, the rule it applies, and
evidence that does not rest on SFM's own output -- Blastware contradicting
itself, the instrument's own data, a third source, or Instantel documentation.
`compare` turns a covered mismatch into `accepted` only when the rule holds,
and every run counts the events each carve-out covers.
Pure: no I/O, and no import from `sfm/`.
"""
from __future__ import annotations
from dataclasses import dataclass
from typing import Callable
from .bw_xml_report import XmlReport
from .decode_check import FieldResult, SfmSide, _printed_number, series_pairs, matches_printed
@dataclass(frozen=True)
class Carveout:
id: str
fields: tuple[str, ...] # exact names, or prefixes ending in "."
evidence: str
applies: Callable[[SfmSide, XmlReport, FieldResult], bool]
_TOL = 0.0006
def _at_ceiling(value: float, r: float) -> bool:
"""SFM's value sits at the range ceiling: a decoder unit or two past nominal
full scale is the clipped count itself (32016 = 10.005 in/s). An 8x
Sensitive-range value is far above the band and does not qualify."""
return r - _TOL <= abs(value) <= r * 1.01
def _clamped(printed: str, r: float) -> bool:
if printed.strip() == "OORANGE":
return True
p = _printed_number(printed)
return p is not None and abs(p[0]) >= r - _TOL
def _differs(v: object, cell: str) -> bool:
"""A cell SFM disagrees with. SFM's own word (its OORANGE, since
2026-11-09) agrees only when Blastware printed the same word."""
if isinstance(v, str):
return " ".join(v.split()) != " ".join(cell.split())
return not matches_printed(v, cell)
def _saturation(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
try:
r = float(ref.scalars["GeoRange"])
except (KeyError, ValueError):
return False
if res.field in ("TranPPV", "VertPPV", "LongPPV"):
v = sfm.values.get(res.field)
return v is not None and _clamped(res.bw or "", r) and _at_ceiling(float(v), r)
if res.field == "PeakVectorSum":
# A vector sum can exceed the range without any clipping, so only
# Blastware's OORANGE counts. SFM's sum is bounded by three channels at
# the ceiling (11.55 on T438HGTZ.B30W), and a channel Blastware itself
# clamped must be the one SFM has at the ceiling -- an unclipped channel
# read 8x high on the Sensitive range does not qualify.
pvs = sfm.values.get("PeakVectorSum")
return ((res.bw or "").strip() == "OORANGE" and pvs is not None
and r - _TOL <= float(pvs) <= 3 ** 0.5 * r * 1.01
and any(_clamped(ref.scalars.get(f, ""), r) and sfm.values.get(f) is not None
and _at_ceiling(float(sfm.values[f]), r)
for f in ("TranPPV", "VertPPV", "LongPPV")))
got = series_pairs(sfm, ref, res.field)
if got is None or got[1]:
return False
if res.field == "intervals.Geo PVS in/s":
# Per interval, as PeakVectorSum: an OORANGE vector sum, SFM's sum within
# three channels at the ceiling, and a channel Blastware itself clamped in
# that interval. 17 / 17 DL2 cells, SFM 10.01 .. 17.33 (2026-11-03).
cols = ref.interval_columns or []
peaks = [cols.index(c) for c in ("Tran Peak in/s", "Vert Peak in/s", "Long Peak in/s")
if c in cols]
rows = ref.intervals or []
differing = [(j, cell, v) for j, cell, v in got[0] if _differs(v, cell)]
return bool(differing) and all(
cell.strip() == "OORANGE" and not isinstance(v, str)
and r - _TOL <= v <= 3 ** 0.5 * r * 1.01
and any(_clamped(rows[j][1][p], r) for p in peaks if p < len(rows[j][1]))
for j, cell, v in differing)
differing = [(cell, v) for _, cell, v in got[0] if _differs(v, cell)]
return bool(differing) and all(
not isinstance(v, str) and _clamped(cell, r) and _at_ceiling(v, r)
and (cell.strip() == "OORANGE" or (v >= 0) == (_printed_number(cell)[0] >= 0))
for cell, v in differing)
SATURATION = Carveout(
id="saturation",
fields=("TranPPV", "VertPPV", "LongPPV", "PeakVectorSum",
"samples.Tran", "samples.Vert", "samples.Long",
"intervals.Tran Peak in/s", "intervals.Vert Peak in/s", "intervals.Long Peak in/s",
"intervals.Geo PVS in/s"),
evidence=("Blastware clamps a clipped channel to the range maximum and prints OORANGE; "
"the file holds counts past full scale (32016 counts = 10.005 in/s observed). "
"scratch/verify_against_ascii.py, 2026-08-28. An interval's vector sum prints "
"OORANGE when it exceeds the range in an interval with a clamped channel: 17 / 17 "
"DL2 cells, 2026-11-03."),
applies=_saturation,
)
def _interval_count_is_duration(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
"""Blastware's count exceeds the intervals in its own table, and SFM decoded
exactly the table's."""
p = _printed_number(res.bw or "")
n = sfm.values.get("NumberofIntervals")
rows = len(ref.intervals or [])
return p is not None and n is not None and rows == n and p[0] > n
INTERVAL_COUNT_IS_DURATION = Carveout(
id="interval-count-is-duration",
fields=("NumberofIntervals",),
evidence=("Blastware's Number of Intervals is (stop - start) / interval from the file's "
"footer times -- exact on T193KSWP.FF0H (2,880), M462KSWR.1R0H (1,650) and "
"T193KY0A.740H (6,390). Its own interval table lists the intervals the file "
"holds: one block (30 at 2 s) fewer when the unit never wrote the last minute. "
"2026-11-02."),
applies=_interval_count_is_duration,
)
_MIC_UNITS = ("in/s and dB(L)", "in/s and psi(L)")
def _units_is_a_display_preference(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
"""Both sides say the event has a mic; they differ only in dB against psi."""
return (" ".join((res.bw or "").split()) in _MIC_UNITS
and sfm.values.get("Units") in _MIC_UNITS)
UNITS_IS_A_DISPLAY_PREFERENCE = Carveout(
id="units-is-a-display-preference",
fields=("Units",),
evidence=("dB(L) or psi(L) is Blastware's display preference on the PC when it wrote the "
"report, not the unit's: in report-write order (the _XML.XML mtimes) DL2's 70,034 "
"reports switch fleet-wide in 61 clean runs, every unit at once, and no byte or "
"bit of the event file separates the two (k-240 .. k+520, nor the 1.2 KB before "
"the footer). Instantel documents both settings: the unit's own Microphone "
"Units (MiniMate Plus manual 716U0101 Rev 15 §3.9.7: psi(L), dB(L) or Pa(L), "
"keypad Right Arrow + Setups) and Blastware's report preference (Blastware "
"manual 714U0301 Rev 22 §4, Preferences > Units and Channel: Show Mic in dB / "
"in Linear Units). 2026-11-03."),
applies=_units_is_a_display_preference,
)
CARVEOUTS: tuple[Carveout, ...] = (SATURATION, INTERVAL_COUNT_IS_DURATION,
UNITS_IS_A_DISPLAY_PREFERENCE)