Files
seismo-relay/sfm/device_access/s3.py
T
serversdownandClaude Opus 5.5 d39f8ef360 fix(sfm): Series-3 status says its serial is unverified
Series 3 status reads no serial, so the serial shown is the requested one, not one the unit reported. detail now carries serial_verified=False.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:12:17 -04:00

124 lines
5.4 KiB
Python

"""Series-3 adapter. Connect-per-request, as SFM has always done for
MiniMates -- a held session waits for the bench test in the spec."""
from __future__ import annotations
import logging
from typing import Any, Callable
from minimateplus import MiniMateClient
from minimateplus.transport import TcpTransport
from .errors import DeviceError, MalformedReply, NoAnswer, WrongUnit, translate
from .models import UnitAddress, UnitInfo, UnitSettings, UnitStatus
log = logging.getLogger("sfm.device_access")
S3_DEFAULT_BAUD = 38400
S3_MODES = {0x00: "Single Shot", 0x01: "Continuous", 0x03: "Histogram", 0x04: "Histogram + Continuous"}
def default_s3_client_factory(address: UnitAddress, timeout: float = 10.0) -> MiniMateClient:
if address.host:
return MiniMateClient(transport=TcpTransport(address.host, port=address.tcp_port), timeout=timeout)
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD)
def _close(client: Any) -> None:
try:
client.close()
except Exception: # noqa: BLE001
log.debug("close failed", exc_info=True)
class Series3Adapter:
def __init__(self, client_factory: Callable[[UnitAddress], Any] = default_s3_client_factory) -> None:
self._factory = client_factory
def _run(self, address: UnitAddress, fn: Callable[[Any], Any]) -> Any:
def attempt() -> Any:
client = self._factory(address)
try:
client.open()
except Exception as exc:
_close(client)
raise translate(exc, connecting=True) from exc
try:
return fn(client)
except DeviceError:
raise
except Exception as exc:
raise translate(exc, connecting=False) from exc
finally:
_close(client)
try:
return attempt()
except NoAnswer:
# A MiniMate that has just had its serial lines asserted can take
# 5-10 s to boot, and shows it as silence; one retry covers it. TCP
# only -- on a serial cable a silence is a real fault. Narrower than
# server._run_with_retry (any protocol error): retrying a
# MalformedReply would also retry "no settings block", which a
# reconnect cannot fix.
if not address.host:
raise
log.info("Series 3 at %s: no clean answer, retrying once (unit may be cold)", address.key)
return attempt()
@staticmethod
def _check(serial_reported: str, serial: str, address: UnitAddress) -> None:
if (serial_reported or "").strip().upper() != serial:
raise WrongUnit(f"asked for {serial} but {serial_reported} answered at {address.key}")
def identify(self, address: UnitAddress, serial: str) -> UnitInfo:
def op(client: Any) -> UnitInfo:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
return UnitInfo(
serial=info.serial, series=3, model=info.model, firmware=info.firmware_version,
monitoring=None, active_setup=cc.setup_name if cc else None,
detail={"manufacturer": info.manufacturer, "dsp_version": info.dsp_version},
)
return self._run(address, op)
def status(self, address: UnitAddress, serial: str) -> UnitStatus:
def op(client: Any) -> UnitStatus:
client.poll()
ms = client.get_monitor_status()
return UnitStatus(
serial=serial, series=3, monitoring=ms.is_monitoring,
battery_volts=round(ms.battery_v, 2) if ms.battery_v is not None else None,
memory_total_bytes=ms.memory_total, memory_free_bytes=ms.memory_free,
device_time=None, event_count=None,
# Series 3 status reads no serial, so the serial shown is the one requested, not one the unit reported.
detail={"serial_verified": False},
)
return self._run(address, op)
def settings(self, address: UnitAddress, serial: str) -> UnitSettings:
def op(client: Any) -> UnitSettings:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
if cc is None:
raise MalformedReply("could not read the unit's settings (SUB 0x1A)")
mode = None
if cc.recording_mode is not None:
mode = S3_MODES.get(cc.recording_mode, f"unknown (0x{cc.recording_mode:02x})")
notes = {
label: value for label, value in (
("Project", cc.project), ("Client", cc.client), ("User Name", cc.operator),
("Seis Loc", cc.sensor_location), ("Extended Notes", cc.notes),
) if value is not None
}
return UnitSettings(
serial=info.serial, series=3, setup_name=cc.setup_name, record_mode=mode,
sample_rate=cc.sample_rate, record_time_s=cc.record_time,
histogram_interval_s=cc.histogram_interval_sec, geo_trigger_ips=cc.trigger_level_geo,
notes=notes,
detail={"record_mode_code": cc.recording_mode, "alarm_level_geo": cc.alarm_level_geo,
"geo_range": cc.geo_range},
)
return self._run(address, op)