serversdownandClaude Opus 5.5 ba826dfac6 fix(mlg): final-review fixes
A fresh whole-branch review found four Important issues; three of its
Minors and one item it set aside were re-graded up.  Each has a test that
failed first.

- A windowed timeline 500'd when a file came without its modified time
  (Python 3.10 rejects the 'Z' of received_at).  received_at is now
  +00:00 and timeline times parse 'Z' too.
- On the clock-step day an event-triggered call-in moved the event into
  the next session and lost the step.  An event now joins the 'monitoring
  started' record of its own file.
- A call-in whose records came first in another file (a cable download)
  read 'nothing_new'.  Each file now keeps its own call summary
  (last_stop, no_file_stops) from when it arrived.
- Sessions and call-ins now carry record_ids / file_ids / file_id, the
  shot report's proof (spec 5).
- A non-'started' record with no stop made the unit's timeline 500 for
  good; it now opens a session whose end is unknown.
- A serial from a file's bytes (or a hint) could write outside the store;
  only plain serials are used, and records with no serial are refused, not
  dropped.
- Times with a UTC offset, an empty 'at', or a bad mtimes value gave 500s
  (or stored half a request); they are now 400s, checked first.
- A missing call-in file made the gap after its Modem Exit read 'not
  monitoring' for days.  Files are numbered <serial><counter>; a gap
  across a missing number is now 'records missing' (unknown).  A long gap
  after a call-in with no number missing is 'no restart after a call-in':
  real outages on the DL2 data (BE6907 14 days from 2026-10-07; BE8081
  over Labor Day 2019).  Real fixtures BE6907 #899-#902 added.
- Docs: BE8081 did write one empty file (BE80811.MLG).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R9LdWawLzUxwewZGA1
2026-11-13 14:17:08 -05:00

19 KiB
Raw Blame History

Monitor logs (.MLG) and each unit's monitoring timeline — design

Date: 2026-11-09 · Branch: feat/mlg-import (worktree ~/seismo-relay-mlg) · Status: design, for review

Why this exists

Every Series-3 unit sends a Blastware monitor log, an .MLG file, at every call-in, whatever mode it is recording in. It lists each time the unit started monitoring, each event, and each time it stopped and why. Event files cannot replace it: a unit in continuous (waveform) mode sends an event file only when something triggers, so a quiet day leaves no file at all.

Brian named two uses (2026-11-09):

  1. Shot reports. Every event from every unit on a site goes in the report. A unit that did not trigger (often the farthest one) is listed as "did not trigger", with its printed .MLG attached as proof it was monitoring at the time of the blast. Example: BE6907 and BE12844 monitored the same job, June to November 2026, both in continuous mode. BE6907 is much farther away and recorded 10 events to BE12844's 55.
  2. Outage history. It is good to know when a unit was not recording, for how long, and why. A unit on solar and battery can die for a weekend and nobody would notice. Most units keep recording when they cannot call in; only losing the power and then the internal battery stops them. So this is history seen once the unit calls in again, not a live alarm.

The .MLG is also what the watcher's heartbeat sniffs today to show that a unit is still calling in. SFM holding the files would later let it answer that itself.

Goals

  1. Read a Blastware .MLG into its records, with every record's checksum verified.
  2. Accept forwarded .MLGs through a new import route, storing each record once.
  3. Keep each unit's monitoring timeline, derived from its records: when it was recording, how each session ended, the events inside, and the call-ins. It must answer two questions:
    • was unit X monitoring at time T, and with what trigger level?
    • when was it not monitoring, for how long, and why?
  4. Serve the records and the timeline through /db/*, for Terra-View to use later.
  5. Bulk-import a directory of .MLGs (DL2 holds about 86,000), and cross-check the records against the event files' footers.

Non-goals

  • The watcher forwarding .MLGs. That is a change in ../series3-watcher, Brian's call, and a separate piece. Until it lands, .MLGs reach SFM only through the import route and the bulk tool.
  • Anything in Terra-View: the timeline view, the shot report, taking "last call-in" from SFM instead of the heartbeat. Later pieces.
  • Live "missed its call-in" alerts. A dead unit sends nothing; this timeline shows the gap once it is back.
  • Series 4. Thor writes no .MLG.
  • Editing the event decoders (event_file_io.py, decode_check.py, histogram_codec.py, waveform_codec.py). Another session owns them; this project imports from them only.

Anti-goals (would make it a failure even if it works)

  • Claiming monitoring the data does not show. A session still open at the last call-in is "running at the last call-in", never "running now". Where a session's end is not recorded, the timeline says so and gives the window it lies in.
  • Dropping a damaged file or record silently. A record that fails its checksum is reported, never half-read into the timeline.
  • Taking the serial from the file name when the file carries it. Names are <serial><counter> with nothing between, so BE11010304 cannot be split by reading it.
  • Mixing clocks. Record times are the unit's own local clock. File times are the PC's. They are stored and labelled separately.

What was measured

Grades: measured means checked on the files named; inferred means a reading of them that has not been tested.

Files examined: 1,273 .MLGs from DL2's C:\Blastware 10\Event\autocall home (BE6907 369 and BE12844 197, from 2026; BE8081 707, 2018–19), in ~/dl2-archive/mlg/. Also the 9 bench files in example-events/. Analysis scripts used for this section are in the session scratchpad and are not part of the build.

The file format (measured on all 1,282 files)

  • Layout: an 18-byte prefix 10 00 01 80 00 00 "Instantel\0" 07 2c, then whole 292-byte records. The size is always 18 + 292·n.
  • Every record is [length uint16 LE = 0x0122 (290)][id 2 bytes] … [CRC 2 bytes]. Id 0e a0 is the header record (one, first, carrying the serial). Id 0e 80 is a log record.
  • Checksum: CRC-16/AUG-CCITT (poly 0x1021, init 0x1D0F, no reflection) over the record's bytes [0:288], stored little-endian at [290:292]. Bytes [288:290] are 00 00 and not covered. This is the rule the Micromate setup blocks use (micromate.setup_block). It matches 3,329 of 3,329 records, with no failures.
    • The reference (D.4.2) put a CRC at the start of each record. That was the previous record's tail, which is also why every file had 2 unexplained bytes at its end.
  • A log record (offsets from its length field):
offset field
[4:12] start: day, month, year LE, 0, hour, min, sec
[12:20] stop, same format; all zeros = no stop
[20:22] monitor-log flag word, uint16 LE: the same word as the event footer's (D.6.14)
[22:24] trigger source, uint16 LE: 0x0001–0x0008 a channel, 0x0400 a histogram
[24:34] serial, null-padded ASCII
[34:…] text, null-padded (below)
  • Text:
    • a "monitoring started" record: Trigger Level : Geo: 0.0500 in/s Mic: 125.0 dB(L), or Trigger Level : Histogram
    • an event record: 08, then the event time in 8 bytes (LE year), then Geo: 0.0500 in/s Mic: 125.0 dB(L)
    • a closed session: Geo: 0.0500 in/s Mic: 125.0 dB(L)
  • Empty files: some files are the 18-byte prefix alone, with no records and so no serial inside.

How Blastware writes them (measured on the 3 DL2 units)

  • One file per call-in, named <serial><counter>.MLG, the counter going up by one each time.
  • No record appears in two files. Each holds what happened since the previous call-in.
  • A file is written 1–2 minutes after the unit stops for its call-in ("Modem Exit"). The unit's clock and DL2's agree to within those 2 minutes.
    • ⚠ Dates of files that came through a Windows zip read an hour early from March to October. Windows converts with the offset in force at zip time, not the one at the file's date. A robocopy copy keeps the true time.
  • BE6907 writes two empty files 2–3 minutes after nearly every real one (230 of its 369). BE12844 never does; BE8081 did once in 707 (BE80811.MLG, 2018-02-19; corrected 2026-11-13 by the final review). Inferred: the unit calls back in and has nothing new.
  • Some files hold more than one Modem Exit: 38 files (BE8081 33, BE6907 3, BE12844 2). A file is written just after its last Modem Exit. The earlier ones are calls that left no file. Example: BE8081321 holds Modem Exits on 2019-04-12 18:33, 04-13 07:00 and 04-15 17:15.
    • Inferred: the call failed, or the PC did not take it.
    • Either way, this is the "missed call-in" history Brian asked about.
  • The unit's clock steps back an hour at the first call-in after daylight saving ends. On 2026-11-01 BE12844 ran 06:00:13 → 18:45:00 (unit still on EDT). It called in at 17:46 EST, and its next session is 17:47:25 → 18:45:00. BE6907 shows the same. So local times on that day overlap. Inferred: Blastware sets the unit's clock at the call-in, and in spring the clock steps forward the same way.
  • Blastware writes the text, not the unit. The two bench copies of the same records (ach-vs-manual/BE11529.MLG, BE115292.MLG) differ only in Trigger Level: Histogram vs Trigger Level : Histogram. A record's identity must not include its text or its checksum.
  • Cable or direct downloads are cumulative. The bench 4-3-26-multi/BE11529.MLG repeats the 4-1 records. Only the call-in files hold "only what is new".

How a session appears (measured on the 3 DL2 units)

  • A session with no events is one closed record: start, stop and why it stopped. BE12844's day: 06:00:13 → 18:45:00 "Modem Exit" (its call-in), then 18:47 → 20:00 "Timer Stop" (a work-hours timer).

  • A session with events is an open "monitoring started" record (flag word ffff, no stop), then one record per event (0x0001 + the channel). The unit calls in minutes after each event, and monitoring resumes as a new session minutes later. Example, BE12844 on 9-8:

    • 06:00:13 started, then an event 13:38:22 → 13:38:25 (Tran)
    • a file written about a minute later
    • next file: 13:41:16 → 18:45:00 "Modem Exit"

    The first session's end is not written anywhere. It lies between the last event's stop and the next session's start (inferred: the call-in after the event ended it).

  • A histogram session is a "monitoring started" record at T, then a histogram record from T+1 s to the stop, carrying the stop reason (0x0021 = Event Recorded + Modem Exit, source 0x0400).

  • A histogram + waveform session also has waveform event records whose start falls inside the histogram record's span (BE8081, 5 in 2018). Example: histogram 15:15:32 → 15:15:49, with a Vert event 15:15:47 → 15:15:49. Its trigger-level text says only "Histogram". The geophone level appears only on its event records.

Cross-check against the event files (measured)

Each "Event Recorded" record was matched to DL2's event files by stop time + flag word + trigger source:

  • BE8081: 785 / 785 records match an event file, and all 785 of its DL2 event files in that period have a record. 714 histogram footers start exactly at the session's "monitoring started" record; the other 71 start where the record does.
  • BE6907 / BE12844: 25 / 25 event files have a record. The 42 records with no file all stop after 2026-08-25, where the DL2 copy ends.
  • On 2026-08-27 both units triggered at 13:00:42 / 13:00:43, the same blast.

Design

1. The reader (codec library: pure, no I/O beyond the file)

read_mlg(path) replaces the stub in minimateplus/blastware_file.py and returns a new model (MlgFile, MlgRecord in models.py). It does not reuse MonitorLogEntry, which is the live 0x0A shape. Per record:

  • start, stop (None when open), flag word, trigger source
  • Blastware's words, from event_file_io.monitor_log_description() (imported, not copied)
  • the text, plus the trigger level and the event time parsed from it
  • whether the checksum passed

Per file: the serial (from the header record; None for an empty file), the records, whether the file is whole. A file whose size is not 18 + 292·n, or with a bad prefix, raises. A record that fails its checksum is returned flagged; the caller decides.

2. write_mlg() (last, small)

Fix it to write what Blastware writes: little-endian times, the length-led framing and the CRC. Test: rebuild bench and DL2 files byte for byte from what the reader returns. If the header record's unread bytes stop that, say so and leave the writer as it is.

3. Storage (sfm/database.py)

  • The original file is kept, byte for byte, in the waveform store beside the unit's event files. Files are tiny (18 bytes to a few KB). It is the shot-report proof, and Blastware can open and print it. Rows alone cannot rebuild it, because Blastware's text varies.

  • mlg_files: one row per file received:

    • serial, file name, size, SHA-256, record count, an empty flag
    • received time, and the file's modified time (UTC, when the sender gives it)
    • whether it is a call-in file (default yes; a cable download is not)

    The same name with the same bytes is a re-send and is skipped. Empty files all share one hash, so the name keeps them apart. Some names have no counter (BE8081.MLG was DL2's first), so name alone is not enough. This table is the call-in history, and the only trace of an empty file.

  • mlg_records: one row per log record: serial, start, stop, flag word, trigger source, text, and the file it first came in. Stored once:

    • unique on (serial, start, stop, flag word, trigger source)
    • ⚠ an open record's stop is NULL, and SQLite treats NULLs as distinct in a UNIQUE constraint. The key must handle that, for example with an index on COALESCE(stop, '').
  • The existing monitor_log table is left alone. It holds live 0x0A rows from bridges/ach_server.py, which is not in production. A future SFM call-in server would write .MLG-shaped records into mlg_records instead.

4. The timeline (computed when asked, not stored)

From a unit's records in time order:

  • A closed record with no event bit is a session [start, stop], ended for its reason.
  • A histogram record is a session from its "monitoring started" record (or its own start, when there is none) to its stop, ended for its reason.
  • A "monitoring started" record followed by events is a session from that start. Its end is "between the last event's stop and the next session's start".
  • A "monitoring started" record with nothing after it yet is "running at the last call-in".

Gaps between sessions take the reason the previous session ended with:

previous session ended with the gap means
Modem Exit a call-in
Timer Stop scheduled off
Battery Low Exit lost power
Keyboard Exit / Remote Exit stopped by a person
Memory Full Exit memory full
none known unknown
  • Waveform events inside a histogram session belong to that session. They are not sessions of their own.
  • Trigger level is reported as logged: the session's text, plus any geophone level its event records carry. It is never borrowed from a neighbouring session. A histogram session with no events says "Histogram", geophone level not logged.
  • Clock steps: a session that starts before the previous one stopped is a clock step, not an overlap. The timeline shows it as such, with no negative gap. Times are the unit's local clock, as SFM's event times are; at, from_dt and to_dt are in that clock. If at falls in a repeated hour and matches two sessions, monitoring_at returns both and says so. The spring step forward will show as a gap an hour too long on that one day; that is accepted.

Call-ins are listed by the call each file came from:

  • Delivered: a call-in file's last Modem Exit (unit clock), paired with the file (PC clock).
  • No file: the earlier Modem Exits in the same file. Calls that left no file.
  • Nothing new: an empty file, at its file time.

Cable-download files are not call-ins.

5. Routes (sfm/server.py)

  • POST /db/import/mlg_file: one or more files, an optional serial hint, each file's modified time when the sender has it, and call_in (default true).
    • Mirrors /db/import/blastware_file: each file gets its own status, and good files are stored even when another in the same request is not.
    • Per file it returns the serial, records inserted and skipped, and whether it was empty.
    • A file with any failed checksum, or that is not whole, stores nothing of itself. Its status names the record.
  • GET /db/mlg_files/{id}: the original file, for printing or opening in Blastware.
  • GET /db/units/{serial}/timeline?from_dt=&to_dt=: sessions (start, end or end window, how it ended, its events, its trigger level), gaps with their meaning, and call-ins.
  • GET /db/units/{serial}/monitoring_at?at=: monitoring / not_monitoring / unknown, with the session and records that say so, and the trigger level. This is the shot report's question.
  • GET /db/mlg_records?serial=&from_dt=&to_dt=: the raw records.

6. Serial of an empty file

An empty file holds no serial. Take, in order:

  1. the request's serial hint
  2. the longest serial SFM already knows (units, events, .MLG headers) that the name starts with
  3. otherwise store the file with no serial and report it as unresolved

7. Tools

  • scripts/import_mlg_dir.py <dir>: imports a directory tree of .MLGs straight into the DB, with a dry run that prints the counts. Same pattern as the backfill scripts. For DL2's ~86,000.
    • Every file it reads is a call-in file (it is pointed at the ACH folder's copy).
    • It records file times as found, but they matter only for empty files. A zipped copy's times are an hour early from March to October.
    • The full DL2 import should come from a robocopy copy, which keeps true times.
  • scratch/check_mlg_vs_events.py <mlg dir> <event dir>: the cross-check above, in both directions, for the whole archive.

8. Documentation

  • Rewrite the reference's D.4 (docs/instantel_protocol_reference.md) with the measured framing, checksum, fields and file behaviour, keeping the old text as a retraction. Mark D.4.3 solved. The file is CRLF: edit it with the Edit tool.
  • 🔑 The event-file footer's checksum (D.3.3, open since April) is the same rule: AUG-CCITT over the footer record from its length 00 1a through byte 24, stored big-endian, 70,041 / 70,041 DL2 files. Recorded on dev by the decoder session (8544e9c, 2026-11-11). Inferred: every record in the event file's tail chain (D.6.13) carries one.

Testing

TDD. Fixtures go in a dated tests/fixtures/ directory (force-added if ignored). A small set covering each shape:

  • a closed-records day (BE12844)
  • a session with an event (BE12844 #3067–#3068)
  • a histogram day (BE8081)
  • a Battery Low Exit (BE8081)
  • an empty 18-byte file (BE6907)
  • a file with calls that left no file (BE8081321)
  • the clock step back (BE12844 #3155–#3156)
  • a histogram + waveform session (BE8081.MLG, 2018-02-16)
  • the 4 bench files, including the ach-vs-manual pair whose text differs

Plus one file with a byte flipped, for the checksum.

The reader, the storage (including that an open record imported twice is stored once), the timeline cases above and the routes each get tests. The full suite has 16 known failures; read the failure list before committing.

Left to the builder

  • Model and helper names; the exact JSON shapes of the routes.
  • Whether read_mlg moves into its own module later.
  • What the header record's other bytes hold (all zero on the files seen).
  • Not in this project: linking a session's events to SFM's stored event ids. Terra-View may want that later. It needs a matcher, because the events table stores neither the stop time nor the flag word, and its times moved in 0.32.0 and 0.34.0.

Later pieces (not this project)

  • The watcher forwards .MLGs with their modified time, and the heartbeat stops sniffing them.
  • Terra-View shows each unit's timeline, puts "monitoring during the blast" on shot reports, and takes "last call-in" from SFM.
  • BE6907's extra call-ins: worth a look at its modem and call-home settings.