"""Write plans for a Micromate: the exact frames a write would send, in order.
|
|
|
|
A plan is what a dry run returns. Building one sends nothing; transmitting it
|
|
also needs a protocol constructed with those SUBs in `allowed_writes`, which no
|
|
code does yet (see `micromate.opcodes`).
|
|
|
|
Every input is the unit's OWN read of the block being written (content, i.e.
|
|
response data[11:]), and every plan sends back exactly what was read except
|
|
the one thing the operation changes. THOR works the same way, and the
|
|
reproduction tests hold the plans to THOR's frames byte for byte.
|
|
|
|
Offsets are THOR's observed constants. 🔶 Each was seen at one block size
|
|
only, so a plan refuses a block of any other size rather than guess.
|
|
"""
|
|
from __future__ import annotations
|
|
|
|
from dataclasses import dataclass, field
|
|
from typing import FrozenSet, List, Tuple
|
|
|
|
from .framing import build_request
|
|
from .opcodes import CROSS_SERIES_COLLISIONS, WRITE_SUBS, OpcodeRefused
|
|
from .setup_block import crc_ok
|
|
|
|
_CONFIRM = 0xFFFF
|
|
|
|
# block content sizes THOR's offsets were observed at (all on UM12947 / 11.0CB)
|
|
_PREFS_LEN, _TRIGGER_LEN, _SETUP_LEN, _CALL_HOME_LEN = 90, 28, 2092, 126
|
|
_NAME_FIELD = 256
|
|
|
|
|
|
@dataclass(frozen=True)
|
|
class WriteStep:
|
|
sub: int
|
|
offset: int
|
|
data: bytes = b""
|
|
params: bytes = field(default=bytes(10))
|
|
what: str = ""
|
|
|
|
def __post_init__(self) -> None:
|
|
# Freeze the bytes: a caller's bytearray must not change a validated step.
|
|
object.__setattr__(self, "data", bytes(self.data))
|
|
object.__setattr__(self, "params", bytes(self.params))
|
|
if len(self.params) != 10:
|
|
raise ValueError(f"params must be 10 bytes, got {len(self.params)}")
|
|
if not 0 <= self.offset <= 0xFFFF:
|
|
raise ValueError(f"offset 0x{self.offset:X} does not fit a uint16")
|
|
if not 0 <= self.sub <= 0xFF:
|
|
raise ValueError(f"SUB {self.sub!r} does not fit a byte")
|
|
|
|
@property
|
|
def ack_sub(self) -> int:
|
|
return 0xFF - self.sub
|
|
|
|
@property
|
|
def frame(self) -> bytes:
|
|
return build_request(self.sub, self.offset, self.params, self.data)
|
|
|
|
def describe(self) -> dict:
|
|
return {"sub": f"0x{self.sub:02X}", "what": self.what,
|
|
"offset": f"0x{self.offset:04X}", "data_len": len(self.data),
|
|
"expect_ack": f"0x{self.ack_sub:02X}", "frame": self.frame.hex()}
|
|
|
|
|
|
@dataclass(frozen=True)
|
|
class WritePlan:
|
|
action: str
|
|
steps: Tuple[WriteStep, ...]
|
|
warnings: Tuple[str, ...] = ()
|
|
|
|
def __post_init__(self) -> None:
|
|
# Copy: a caller's list must not be able to add a step after validation.
|
|
object.__setattr__(self, "steps", tuple(self.steps))
|
|
object.__setattr__(self, "warnings", tuple(self.warnings))
|
|
for s in self.steps:
|
|
if not isinstance(s, WriteStep):
|
|
raise TypeError(f"a plan holds WriteStep objects, got {type(s).__name__}")
|
|
if s.sub in CROSS_SERIES_COLLISIONS:
|
|
raise OpcodeRefused(
|
|
f"a plan cannot hold SUB 0x{s.sub:02X}: {CROSS_SERIES_COLLISIONS[s.sub]}")
|
|
if s.sub not in WRITE_SUBS:
|
|
raise ValueError(f"SUB 0x{s.sub:02X} is not a write opcode")
|
|
|
|
@property
|
|
def subs(self) -> FrozenSet[int]:
|
|
return frozenset(s.sub for s in self.steps)
|
|
|
|
def frames(self) -> List[bytes]:
|
|
return [s.frame for s in self.steps]
|
|
|
|
def describe(self) -> dict:
|
|
return {"action": self.action, "sends_nothing": True,
|
|
"warnings": list(self.warnings),
|
|
"steps": [s.describe() for s in self.steps]}
|
|
|
|
|
|
def plan_start_monitoring() -> WritePlan:
|
|
return WritePlan("start monitoring", (WriteStep(0x96, _CONFIRM, what="start monitoring"),))
|
|
|
|
|
|
def plan_stop_monitoring() -> WritePlan:
|
|
return WritePlan("stop monitoring", (WriteStep(0x97, _CONFIRM, what="stop monitoring"),))
|
|
|
|
|
|
def plan_call_home_enabled(call_home: bytes, enabled: bool) -> WritePlan:
|
|
"""Read `0x2C`, flip bit 0 of content[5], send the rest back byte for byte.
|
|
|
|
Bit 0 of `[5]` is the enable. 🔶 UM12947 (THOR's unit) read 0x05 enabled /
|
|
0x04 disabled, bit 2 set in both; UM20147 reads 0x01 (measured, phase-2 dry
|
|
run). So on UM20147 "off" writes 0x00, a value no capture shows being
|
|
written: the target value there is unobserved, and the plan's `warnings`
|
|
say so. `[118:120]` is unit-maintained and THOR echoes it.
|
|
"""
|
|
if len(call_home) != _CALL_HOME_LEN:
|
|
raise ValueError(f"call-home content must be {_CALL_HOME_LEN} B "
|
|
f"(the size THOR's offset was seen at), got {len(call_home)}")
|
|
b5 = (call_home[5] | 0x01) if enabled else (call_home[5] & 0xFE)
|
|
data = call_home[:5] + bytes([b5]) + call_home[6:]
|
|
what = "call-home " + ("enable" if enabled else "disable")
|
|
start = call_home[5]
|
|
warnings = []
|
|
if start not in (0x04, 0x05) or b5 not in (0x04, 0x05):
|
|
warnings.append(f"content[5] 0x{start:02X} -> 0x{b5:02X}: THOR was only ever "
|
|
"seen writing 0x04/0x05 (UM12947); this value is unobserved")
|
|
if b5 == start:
|
|
warnings.append(f"the unit is already call-home {'enabled' if enabled else 'disabled'}"
|
|
" -- this write changes nothing")
|
|
return WritePlan(what, (
|
|
WriteStep(0x7E, 0x007E, data, what="call-home config write"),
|
|
WriteStep(0x7F, _CONFIRM, what="call-home config confirm"),
|
|
), tuple(warnings))
|
|
|
|
|
|
def _checked(block: bytes, size: int, label: str) -> bytes:
|
|
if len(block) != size:
|
|
raise ValueError(f"{label} block size {len(block)} B is not the {size} B "
|
|
"THOR's offset was observed at -- refusing to guess")
|
|
if int.from_bytes(block[0:2], "big") != size - 2:
|
|
raise ValueError(f"{label} block's own header says "
|
|
f"{int.from_bytes(block[0:2], 'big')}, expected {size - 2} -- "
|
|
"not the block it claims to be")
|
|
if not crc_ok(block):
|
|
raise ValueError(f"{label} block failed its checksum -- refusing to write a "
|
|
"corrupt read back to the unit")
|
|
return block
|
|
|
|
|
|
def plan_setup_push(prefs: bytes, trigger: bytes, setup: bytes, name: str) -> WritePlan:
|
|
"""Rewrite a setup as THOR does: read 0x08, 0x2E, 0x1A, send each back.
|
|
|
|
No field editing here (phase 5). Each block goes back with its length echo
|
|
[0:3] zeroed; the unit recomputes the CRCs, so 0x68 and 0x71 drop the CRC
|
|
slot and 0x82 sends it zeroed -- exactly THOR's frames.
|
|
|
|
⚠ `0x1A` reads the keypad's edit buffer live. A setup read taken while
|
|
someone is in the unit's menu includes their unsaved edits, and pushing
|
|
this plan would commit them.
|
|
|
|
The name goes out exactly as given. `MicromateClient.get_active_setup()`
|
|
strips whitespace, so a setup name with leading or trailing spaces would
|
|
not round-trip through it; phase 5 decides whether to take the unstripped
|
|
name from the 0x41 read.
|
|
"""
|
|
_checked(prefs, _PREFS_LEN, "preferences (0x08)")
|
|
_checked(trigger, _TRIGGER_LEN, "trigger (0x2E)")
|
|
_checked(setup, _SETUP_LEN, "setup (0x1A)")
|
|
try:
|
|
raw = name.encode("ascii")
|
|
except UnicodeEncodeError:
|
|
raise ValueError(f"setup name must be ASCII: {name!r}") from None
|
|
if not raw or b"\x00" in raw or len(raw) >= _NAME_FIELD:
|
|
raise ValueError(f"setup name must be 1-{_NAME_FIELD - 1} ASCII bytes "
|
|
f"with no NUL: {name!r}")
|
|
return WritePlan(f"setup push: {name}", (
|
|
WriteStep(0xDA, 0x0100, raw.ljust(_NAME_FIELD, b"\x00"), what="setup file name"),
|
|
WriteStep(0x68, 0x005A, bytes(3) + prefs[3:88], what="preferences block"),
|
|
WriteStep(0x73, _CONFIRM, what="preferences confirm"),
|
|
WriteStep(0x82, 0x001C, bytes(3) + trigger[3:26] + bytes(2), what="trigger block"),
|
|
WriteStep(0x83, _CONFIRM, what="trigger confirm"),
|
|
WriteStep(0x71, 0x082C, bytes(3) + setup[3:2090], what="setup block"),
|
|