Files
seismo-relay/minimateplus/decode_check_carveouts.py
T
serversdownandClaude Opus 5.5 aec4a38473 fix(decode): histograms go to the histogram codec, and a loud interval no longer hides a short one
Three causes behind the histograms the checker found decoding wrongly:

1. The file decoder tried the waveform codec first, whatever the record
   type.  It accepted BE9440 / BE9557 / BE17354's 2018 5 s histograms and
   returned ~5x too many 'samples' (K440HDXX.XH0H: SFM 44,504, Blastware
   6,976).  The codec now follows STRT[18] (0x46 / 0x0A on 70,041 /
   70,041 DL2 files); only an unknown type falls back to trial order, and a
   chosen codec that fails is a decode problem rather than a silent switch.

2. The sub-minute layout check required each record's 'zero word' to be
   0000.  It is the high word of the interval's PVS squared, non-zero above
   1.28 in/s, so a one-block histogram with a loud interval was not
   recognised (T193KR5M.X90H, K440HA3C.JM0H, R352HFZ7.530H decoded to
   nothing).  The check is now the measured relation peak <= PVS <=
   sqrt(3) * peak, which holds on 34,502,955 / 34,502,955 DL2 sub-minute
   intervals.  The no-terminal-tail trim uses the same test.  Two test
   builders wrote PVS bytes no real record has (one still in the retracted
   little-endian layout); they now write peak^2 in the measured layout, and
   the retraction test keeps a legacy builder of its own.

3. Checker carve-out interval-count-is-duration: Blastware's Number of
   Intervals is (stop - start) / interval from the footer times, and its
   own interval table lists one block fewer when the unit never wrote the
   last minute.  SFM matches the table (T193KSWP.FF0H: 2,880 vs 2,850).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-02 16:20:32 -05:00

110 lines
4.6 KiB
Python

"""
minimateplus/decode_check_carveouts.py — the proven ways Blastware's report
differs from the instrument's data.
Every disagreement between SFM and Blastware is SFM's bug until shown otherwise.
A carve-out is that showing: the fields it covers, the rule it applies, and
evidence that does not rest on SFM's own output -- Blastware contradicting
itself, the instrument's own data, a third source, or Instantel documentation.
`compare` turns a covered mismatch into `accepted` only when the rule holds,
and every run counts the events each carve-out covers.
Pure: no I/O, and no import from `sfm/`.
"""
from __future__ import annotations
from dataclasses import dataclass
from typing import Callable
from .bw_xml_report import XmlReport
from .decode_check import FieldResult, SfmSide, _printed_number, series_pairs, matches_printed
@dataclass(frozen=True)
class Carveout:
id: str
fields: tuple[str, ...] # exact names, or prefixes ending in "."
evidence: str
applies: Callable[[SfmSide, XmlReport, FieldResult], bool]
_TOL = 0.0006
def _at_ceiling(value: float, r: float) -> bool:
"""SFM's value sits at the range ceiling: a decoder unit or two past nominal
full scale is the clipped count itself (32016 = 10.005 in/s). An 8x
Sensitive-range value is far above the band and does not qualify."""
return r - _TOL <= abs(value) <= r * 1.01
def _clamped(printed: str, r: float) -> bool:
if printed.strip() == "OORANGE":
return True
p = _printed_number(printed)
return p is not None and abs(p[0]) >= r - _TOL
def _saturation(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
try:
r = float(ref.scalars["GeoRange"])
except (KeyError, ValueError):
return False
if res.field in ("TranPPV", "VertPPV", "LongPPV"):
v = sfm.values.get(res.field)
return v is not None and _clamped(res.bw or "", r) and _at_ceiling(float(v), r)
if res.field == "PeakVectorSum":
# A vector sum can exceed the range without any clipping, so only
# Blastware's OORANGE counts. SFM's sum is bounded by three channels at
# the ceiling (11.55 on T438HGTZ.B30W), and a channel Blastware itself
# clamped must be the one SFM has at the ceiling -- an unclipped channel
# read 8x high on the Sensitive range does not qualify.
pvs = sfm.values.get("PeakVectorSum")
return ((res.bw or "").strip() == "OORANGE" and pvs is not None
and r - _TOL <= float(pvs) <= 3 ** 0.5 * r * 1.01
and any(_clamped(ref.scalars.get(f, ""), r) and sfm.values.get(f) is not None
and _at_ceiling(float(sfm.values[f]), r)
for f in ("TranPPV", "VertPPV", "LongPPV")))
got = series_pairs(sfm, ref, res.field)
if got is None or got[1]:
return False
differing = [(cell, v) for _, cell, v in got[0] if not matches_printed(v, cell)]
return bool(differing) and all(
_clamped(cell, r) and _at_ceiling(v, r)
and (cell.strip() == "OORANGE" or (v >= 0) == (_printed_number(cell)[0] >= 0))
for cell, v in differing)
SATURATION = Carveout(
id="saturation",
fields=("TranPPV", "VertPPV", "LongPPV", "PeakVectorSum",
"samples.Tran", "samples.Vert", "samples.Long",
"intervals.Tran Peak in/s", "intervals.Vert Peak in/s", "intervals.Long Peak in/s"),
evidence=("Blastware clamps a clipped channel to the range maximum and prints OORANGE; "
"the file holds counts past full scale (32016 counts = 10.005 in/s observed). "
"scratch/verify_against_ascii.py, 2026-08-28."),
applies=_saturation,
)
def _interval_count_is_duration(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
"""Blastware's count exceeds the intervals in its own table, and SFM decoded
exactly the table's."""
p = _printed_number(res.bw or "")
n = sfm.values.get("NumberofIntervals")
rows = len(ref.intervals or [])
return p is not None and n is not None and rows == n and p[0] > n
INTERVAL_COUNT_IS_DURATION = Carveout(
id="interval-count-is-duration",
fields=("NumberofIntervals",),
evidence=("Blastware's Number of Intervals is (stop - start) / interval from the file's "
"footer times -- exact on T193KSWP.FF0H (2,880), M462KSWR.1R0H (1,650) and "
"T193KY0A.740H (6,390). Its own interval table lists the intervals the file "
"holds: one block (30 at 2 s) fewer when the unit never wrote the last minute. "
"2026-11-02."),
applies=_interval_count_is_duration,
)
CARVEOUTS: tuple[Carveout, ...] = (SATURATION, INTERVAL_COUNT_IS_DURATION)