The setup block has Series IV's 0x1A layout here too: report flags at
k - 9 (bit 0x02 = job number shown) and the number, uint16 BE, at k - 8,
kept while switched off. The flag matches Blastware's JobNumber on
2,997 / 2,997 DL2 events that print one and 66,986 / 66,986 that don't.
Every printed value is 1 and matches; hidden ones hold real numbers
(802, 1012, 1013, 622), so the value is only proven for 1.
- ProjectInfo.job_number_enabled / job_number, named as in
micromate.setup_block.
- write_event_hdf5 stores both as .h5 attrs when read (additive).
- The checker reports the number only when shown, and scores a number
only SFM shows as a mismatch. The old test that pinned JobNumber as
sfm_blank now checks only the ZC cases it also covered.
Not carried into the DB, the API or the PDF report yet (needs a column).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9