feat: persistent monitor_enabled flag + auto-start keepalive on boot

Makes live monitoring (and therefore alerting) genuinely 24/7 and
restart-surviving, instead of runtime-only keepalive.

- NL43Config.monitor_enabled (default True) + migrate_add_monitor_enabled.py.
- On startup, auto-start keepalive monitors for every monitor_enabled +
  tcp_enabled unit — so feeds/alerts resume after a restart with no manual step.
- /monitor/start and /monitor/stop now PERSIST monitor_enabled (start=True,
  stop=False) in addition to applying keepalive at runtime, so the toggle
  sticks. Roster output includes monitor_enabled for the admin UI to read.

On by default: configure a unit -> it's monitored 24/7 unless toggled off.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
This commit is contained in:
2026-06-09 19:27:25 +00:00
parent 9d34779171
commit 43e72ae3c3
4 changed files with 89 additions and 7 deletions
+19
View File
@@ -38,6 +38,25 @@ async def lifespan(app: FastAPI):
await poller.start() await poller.start()
logger.info("Background poller started") logger.info("Background poller started")
# Auto-start keepalive live monitors for units configured for 24/7 monitoring
# (monitor_enabled). This is what keeps alerting running unattended across
# restarts — without it a feed only runs while someone has the live view open.
try:
from app.monitor import monitor_manager
from app.database import SessionLocal
from app.models import NL43Config
db = SessionLocal()
try:
units = db.query(NL43Config).filter_by(monitor_enabled=True, tcp_enabled=True).all()
for cfg in units:
m = await monitor_manager.get(cfg.unit_id)
await m.set_keepalive(True)
logger.info(f"Auto-started keepalive monitor for {cfg.unit_id}")
finally:
db.close()
except Exception as e:
logger.error(f"Failed to auto-start monitors: {e}")
yield # Application runs yield # Application runs
# Shutdown # Shutdown
+4
View File
@@ -23,6 +23,10 @@ class NL43Config(Base):
poll_interval_seconds = Column(Integer, nullable=True, default=60) # Polling interval (10-3600 seconds) poll_interval_seconds = Column(Integer, nullable=True, default=60) # Polling interval (10-3600 seconds)
poll_enabled = Column(Boolean, default=True) # Enable/disable background polling for this device poll_enabled = Column(Boolean, default=True) # Enable/disable background polling for this device
# Live monitor (fan-out DOD feed). Keepalive runs it 24/7 even with no viewer,
# which is what makes alerting continuous. On by default; toggleable from the UI.
monitor_enabled = Column(Boolean, default=True)
class NL43Status(Base): class NL43Status(Base):
""" """
+18 -7
View File
@@ -295,22 +295,32 @@ async def monitor_stream(websocket: WebSocket, unit_id: str):
@router.post("/{unit_id}/monitor/start") @router.post("/{unit_id}/monitor/start")
async def monitor_start(unit_id: str): async def monitor_start(unit_id: str, db: Session = Depends(get_db)):
"""Keep the device's feed running even with no browser attached, so alerting """Enable 24/7 keepalive monitoring: persist monitor_enabled and start the feed
evaluates continuously. Runtime-only (resets on restart).""" now, so alerting evaluates continuously even with no viewer. Survives restarts
(auto-started on boot from the persisted flag)."""
cfg = db.query(NL43Config).filter_by(unit_id=unit_id).first()
if cfg:
cfg.monitor_enabled = True
db.commit()
from app.monitor import monitor_manager from app.monitor import monitor_manager
monitor = await monitor_manager.get(unit_id) monitor = await monitor_manager.get(unit_id)
await monitor.set_keepalive(True) await monitor.set_keepalive(True)
return {"status": "ok", "unit_id": unit_id, "running": monitor.running, "keepalive": True} return {"status": "ok", "unit_id": unit_id, "monitor_enabled": True, "running": monitor.running}
@router.post("/{unit_id}/monitor/stop") @router.post("/{unit_id}/monitor/stop")
async def monitor_stop(unit_id: str): async def monitor_stop(unit_id: str, db: Session = Depends(get_db)):
"""Drop the keep-alive; the feed stops once no browser subscribers remain.""" """Disable keepalive monitoring: persist monitor_enabled=False and drop the
keepalive (the feed stops once no browser subscribers remain)."""
cfg = db.query(NL43Config).filter_by(unit_id=unit_id).first()
if cfg:
cfg.monitor_enabled = False
db.commit()
from app.monitor import monitor_manager from app.monitor import monitor_manager
monitor = await monitor_manager.get(unit_id) monitor = await monitor_manager.get(unit_id)
await monitor.set_keepalive(False) await monitor.set_keepalive(False)
return {"status": "ok", "unit_id": unit_id, "keepalive": False} return {"status": "ok", "unit_id": unit_id, "monitor_enabled": False}
@router.get("/_monitor/status") @router.get("/_monitor/status")
@@ -501,6 +511,7 @@ def get_roster(db: Session = Depends(get_db)):
"web_enabled": cfg.web_enabled, "web_enabled": cfg.web_enabled,
"poll_enabled": cfg.poll_enabled, "poll_enabled": cfg.poll_enabled,
"poll_interval_seconds": cfg.poll_interval_seconds, "poll_interval_seconds": cfg.poll_interval_seconds,
"monitor_enabled": cfg.monitor_enabled,
"status": None "status": None
} }
+48
View File
@@ -0,0 +1,48 @@
#!/usr/bin/env python3
"""
Migration: add monitor_enabled column to nl43_config.
Controls whether the live fan-out DOD monitor is kept alive 24/7 for a unit
(which is what makes alerting continuous). Defaults to enabled. Run once per DB.
"""
import sqlite3
import sys
from pathlib import Path
DB_PATH = Path(__file__).parent / "data" / "slmm.db"
def migrate():
if not DB_PATH.exists():
print(f"Database not found at {DB_PATH}")
print("No migration needed - database will be created with new schema")
return
conn = sqlite3.connect(DB_PATH)
cursor = conn.cursor()
try:
cursor.execute("PRAGMA table_info(nl43_config)")
columns = [row[1] for row in cursor.fetchall()]
if "monitor_enabled" in columns:
print("✓ monitor_enabled column already exists, no migration needed")
return
print("Adding monitor_enabled column (default enabled)...")
# SQLite stores booleans as 0/1; default 1 = enabled.
cursor.execute("ALTER TABLE nl43_config ADD COLUMN monitor_enabled BOOLEAN DEFAULT 1")
conn.commit()
print("✓ Added monitor_enabled column")
print("\n✓ Migration completed successfully!")
except Exception as e:
conn.rollback()
print(f"✗ Migration failed: {e}", file=sys.stderr)
sys.exit(1)
finally:
conn.close()
if __name__ == "__main__":