Added: Ability to change store name and overwrite protection
This commit is contained in:
111
migrate_field_names.py
Normal file
111
migrate_field_names.py
Normal file
@@ -0,0 +1,111 @@
|
||||
#!/usr/bin/env python3
|
||||
"""
|
||||
Migration script to rename NL43 measurement field names to match actual device output.
|
||||
|
||||
Changes:
|
||||
- lp -> laeq (A-weighted equivalent continuous sound level)
|
||||
- leq -> lae (A-weighted sound exposure level)
|
||||
- lmax -> lasmax (A-weighted slow maximum)
|
||||
- lmin -> lasmin (A-weighted slow minimum)
|
||||
- lpeak -> lapeak (A-weighted peak)
|
||||
"""
|
||||
|
||||
import sqlite3
|
||||
import sys
|
||||
from pathlib import Path
|
||||
|
||||
def migrate_database(db_path: str):
|
||||
"""Migrate the database schema to use correct field names."""
|
||||
|
||||
print(f"Migrating database: {db_path}")
|
||||
|
||||
# Connect to database
|
||||
conn = sqlite3.connect(db_path)
|
||||
cur = conn.cursor()
|
||||
|
||||
try:
|
||||
# Check if migration is needed
|
||||
cur.execute("PRAGMA table_info(nl43_status)")
|
||||
columns = [row[1] for row in cur.fetchall()]
|
||||
|
||||
if 'laeq' in columns:
|
||||
print("✓ Database already migrated")
|
||||
return
|
||||
|
||||
if 'lp' not in columns:
|
||||
print("✗ Database schema does not match expected format")
|
||||
sys.exit(1)
|
||||
|
||||
print("Starting migration...")
|
||||
|
||||
# SQLite doesn't support column renaming directly, so we need to:
|
||||
# 1. Create new table with correct column names
|
||||
# 2. Copy data from old table
|
||||
# 3. Drop old table
|
||||
# 4. Rename new table
|
||||
|
||||
# Create new table with correct column names
|
||||
cur.execute("""
|
||||
CREATE TABLE nl43_status_new (
|
||||
unit_id VARCHAR PRIMARY KEY,
|
||||
last_seen DATETIME,
|
||||
measurement_state VARCHAR,
|
||||
laeq VARCHAR,
|
||||
lae VARCHAR,
|
||||
lasmax VARCHAR,
|
||||
lasmin VARCHAR,
|
||||
lapeak VARCHAR,
|
||||
battery_level VARCHAR,
|
||||
power_source VARCHAR,
|
||||
sd_remaining_mb VARCHAR,
|
||||
sd_free_ratio VARCHAR,
|
||||
raw_payload TEXT
|
||||
)
|
||||
""")
|
||||
print("✓ Created new table with correct column names")
|
||||
|
||||
# Copy data from old table to new table
|
||||
cur.execute("""
|
||||
INSERT INTO nl43_status_new
|
||||
(unit_id, last_seen, measurement_state, laeq, lae, lasmax, lasmin, lapeak,
|
||||
battery_level, power_source, sd_remaining_mb, sd_free_ratio, raw_payload)
|
||||
SELECT
|
||||
unit_id, last_seen, measurement_state, lp, leq, lmax, lmin, lpeak,
|
||||
battery_level, power_source, sd_remaining_mb, sd_free_ratio, raw_payload
|
||||
FROM nl43_status
|
||||
""")
|
||||
rows_copied = cur.rowcount
|
||||
print(f"✓ Copied {rows_copied} rows from old table")
|
||||
|
||||
# Drop old table
|
||||
cur.execute("DROP TABLE nl43_status")
|
||||
print("✓ Dropped old table")
|
||||
|
||||
# Rename new table
|
||||
cur.execute("ALTER TABLE nl43_status_new RENAME TO nl43_status")
|
||||
print("✓ Renamed new table to nl43_status")
|
||||
|
||||
# Commit changes
|
||||
conn.commit()
|
||||
print("✓ Migration completed successfully")
|
||||
|
||||
except Exception as e:
|
||||
conn.rollback()
|
||||
print(f"✗ Migration failed: {e}")
|
||||
sys.exit(1)
|
||||
finally:
|
||||
conn.close()
|
||||
|
||||
if __name__ == "__main__":
|
||||
# Default database path
|
||||
db_path = Path(__file__).parent / "data" / "slmm.db"
|
||||
|
||||
# Allow custom path as command line argument
|
||||
if len(sys.argv) > 1:
|
||||
db_path = Path(sys.argv[1])
|
||||
|
||||
if not db_path.exists():
|
||||
print(f"✗ Database not found: {db_path}")
|
||||
sys.exit(1)
|
||||
|
||||
migrate_database(str(db_path))
|
||||
Reference in New Issue