Completes the SLMM side of the L1/L10 live-display contract. The NL-43's
DOD response carries percentile slots LN1-LN5 (channel 1, parts[5]/[6]);
parse the first two and expose them as ln1/ln2 end to end:
- NL43Snapshot dataclass: ln1/ln2 fields
- NL43Status model: ln1/ln2 columns (+ migrate_add_ln_percentiles.py)
- DOD parser: snap.ln1=parts[5], snap.ln2=parts[6]
- persist_snapshot writes them
- all /status data dicts, StatusPayload, and the DRD stream payload emit
ln1/ln2 (null on the DRD stream itself, which doesn't carry percentiles)
Labels: device LN1 defaults to L5, not L1 — Terra-View defaults the label
to L1/L10, so the device's Ln1/Ln2 slots must be set to 1%/10% for the
labels to be accurate (dynamic label emission is a follow-up).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- db cache dump on diagnostics request.
- individual device logs, db and files.
-Device logs api endpoints and diagnostics UI.
Fix:
- slmm standalone now uses local TZ (was UTC only before)
- fixed measurement start time logic.
- Implement migration script to add ftp_username and ftp_password columns to nl43_config table.
- Create set_ftp_credentials.py script for updating FTP credentials in the database.
- Update requirements.txt to include aioftp for FTP functionality.
- Enhance index.html with FTP controls including enable, disable, check status, and list files features.
- Add JavaScript functions for handling FTP operations and displaying file lists.