docs(changelog): Unreleased -- identity, battery and trigger settings from the file

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-03 17:23:07 -05:00
1 parent 3ee9923f81
commit 06a4be9445
1 file changed
+42
+42
View File
@@ -92,6 +92,48 @@ All notable changes to seismo-relay are documented here.
change.
### Added
- **A Blastware file's identity, battery and trigger settings** (group A of the
file-only decode). Every field is matched against every DL2 report
(2026-11-03).
- **Identity block** before the setup name: what the live read gets from
SUB FE.
- serial `k − 202`, firmware `k − 147`, DSP version `k − 138`, firmware
minor `k − 193`
- calibration date `k − 132` and "by" `k − 128`
- manufacturer `k − 94`, model `k − 72`
- Filled into `Event.device_info`; `DeviceInfo` gains `calibration_date` /
`calibrated_by`.
- Serial, Version and Calibration match 70,042 / 70,042.
- **Battery:** uint16 hundredths of a volt at `k − 190`
(`Event.battery_volts`), 70,042 / 70,042. Blastware rounds half up
(6.25 → "6.3 Volts").
- **Trigger source:** the two bytes between the embedded event record's lead
and `fe 80`, a bitmask (`0x01` Tran, `0x02` Vert, `0x04` Long, `0x08`
MicL, `0x200` Manual). 6,524 / 6,524 (`Event.triggered_by`).
- **Trigger settings,** in Series IV's `0x1A` layout:
- the sources bitmask at `k − 19`
- the stop mode at `k − 31` (0 = Fixed)
- each channel's float32 level at label + 30 (geo in/s, mic psi)
- the mic type code at MicL + 4 (2 = Linear Weighting)
Blastware prints a level when its channel is a trigger source and the
event wasn't Manual. Geo level 6,484 / 6,484, mic level 4,412 / 4,412
(its dB uses 6895 Pa/psi).
- **`.h5`:** all of them as attributes (additive).
- **Decode checker:** 444,188 comparisons fixed, 0 regressions, 28 of 88
fields fully match (was 18).
- A mic level is now compared in the unit it is printed in: K441LA17.IN0W
prints dB under psi Units.
- New carve-out `units-is-a-display-preference` (3,532 events). dB or psi
in a Blastware report is that PC's Blastware preference when it wrote the
report (Blastware manual §4, Preferences → Units and Channel), not the
unit's Microphone Units setting (MiniMate Plus manual §3.9.7). DL2's
reports switch fleet-wide in 61 clean runs by write time, and no byte of
the file separates them.
- Single-value fields are proven for that value only: Version `10.72-8.17`,
stop mode Fixed, mic type Linear.
- ⚠ **Codec change:** it rides the next release's `TOOL_VERSION` bump and
backfill. No schema change.
- **A Blastware file's job number, and whether Blastware shows it.**
- **Where it is:** the setup block has Series IV's `0x1A` layout here too.
The report flags sit at 9 bytes before the setup name, with bit `0x02`