docs: serial parameter, settings/hangup endpoints, single-worker rule, cool-down prerequisite for 1c
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
d393a149f8
commit
080e8f4704
3 files changed
+25
No files matched your search
@@ -1410,8 +1410,15 @@ GET /device/event?host=1.2.3.4&tcp_port=9034&index=0
|
||||
GET /device/monitor/status?host=1.2.3.4&tcp_port=9034 ← battery, memory, mode
|
||||
POST /device/monitor/start?host=1.2.3.4&tcp_port=9034 ← start recording
|
||||
POST /device/monitor/stop?host=1.2.3.4&tcp_port=9034 ← stop recording
|
||||
GET /device/settings?serial=UM20147&host=1.2.3.4&tcp_port=9034 ← shared-model settings, either series
|
||||
POST /device/hangup?host=1.2.3.4&tcp_port=9034 ← release a held Series-4 line
|
||||
```
|
||||
|
||||
`serial=` (UM = Series 4, BE/BA = Series 3) on `/device/info`, `/connect`,
|
||||
`/monitor/status`, `/settings` returns the shared model, uncached. A `UM` serial on any
|
||||
other `/device/*` route is 501; serial-less requests at a held Series-4 address are 409.
|
||||
SFM must run a single uvicorn worker (locks and held lines are per process).
|
||||
|
||||
Server retries once on `ProtocolError` for TCP connections (handles cold-boot timing).
|
||||
|
||||
### DB read endpoints (query seismo_relay.db written by ach_server.py)
|
||||
|
||||
@@ -177,10 +177,22 @@ via a thread-safe `_LiveCache` (plain Python dict + `threading.Lock`):
|
||||
| `POST` | `/device/monitor/start` | Sends SUB 0x96; immediately evicts status cache |
|
||||
| `POST` | `/device/monitor/stop` | Sends SUB 0x97; immediately evicts status cache |
|
||||
| `POST` | `/device/call_home` | Reads, patches specified fields, writes back to device |
|
||||
| `GET` | `/device/settings` | Recording settings in the shared model, either series; serial required; never cached |
|
||||
| `POST` | `/device/hangup` | Releases a held Series-4 line now; `{"hung_up": bool}` |
|
||||
|
||||
**Cache bypass** — All cached endpoints accept `?force=true` to skip the cache and
|
||||
force a fresh read from the device.
|
||||
|
||||
**Serial-named requests (Series 3 and 4)** — `/device/info`, `/device/connect`,
|
||||
`/device/monitor/status` and `/device/settings` accept `serial` (`UM...` = Series 4
|
||||
Micromate, `BE...`/`BA...` = Series 3 MiniMate Plus) and return one shared model
|
||||
for either series. Serial-named requests are **not cached** and ignore `force`.
|
||||
Without `serial` the legacy Series-3 behaviour is unchanged. Any other `/device/*`
|
||||
route given a `UM` serial answers **501** ("not supported for Series 4 yet"), and a
|
||||
serial-less request at an address holding a Series-4 line answers **409** (use
|
||||
`POST /device/hangup` first). Series-4 lines are held open between requests, so
|
||||
SFM must run a **single uvicorn worker**: locks and held lines are per process.
|
||||
|
||||
**Cache stats** — `GET /cache/stats` returns hit/miss counts and TTL info; `DELETE /cache/device`
|
||||
clears the device cache immediately.
|
||||
|
||||
|
||||
@@ -332,6 +332,12 @@ Each safety piece arrives with its first real use, so nothing sits untested.
|
||||
- 1b. Event list and download for both series (rows 4–5).
|
||||
- 1c. **The webapp:** serial + address, and the same read panels for both
|
||||
series.
|
||||
- **HARD PREREQUISITE:** before any poller or webapp sends `serial`, add a
|
||||
per-address cool-down after a RADIO RING: call-ups to that address answer
|
||||
503 + `Retry-After` until it expires, and `POST /device/hangup` clears it.
|
||||
The length must come from the unit's measured call-home retry timing (a
|
||||
bench test). Without it a poller can re-grab the modem's single TCP
|
||||
session through every retry, and the call never reaches THOR.
|
||||
2. **Encoder + opcode guard + dry run + frame-reproduction tests.** Still
|
||||
nothing sent.
|
||||
3. **Start/stop monitoring** (row 7): the first live write, at the bench.
|
||||
|
||||
Reference in new issue
Block a user