docs: the Micromate line hold stays for now; SFM handling call-ins is the long-term fix
Brian, 2026-10-29: not expected to be a problem in practice. Settles the 1c ring-path merge gate; Run B stays open, not blocking. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
7491cd4b6f
commit
335f70ff46
2 files changed
+11
-7
No files matched your search
@@ -198,8 +198,9 @@ Read this first when picking the project back up.
|
||||
reaches THOR when nobody holds the line, and **is lost when SFM holds it** --
|
||||
the unit takes SFM's connection for the call, times out and does not retry.
|
||||
While THOR polls a unit, SFM gets no reply and does not disturb THOR.
|
||||
⚠ **Before merge: decide the Micromate line hold** (shorter / none, or SFM
|
||||
runs the call-home session). THOR's log: `C:\THORDATA\Logs\`.
|
||||
✅ **Line hold decided (Brian, 2026-10-29): keep it as is for now; the
|
||||
long-term fix is SFM handling auto call-ins itself.** The ring-path merge gate
|
||||
is settled. THOR's log: `C:\THORDATA\Logs\`.
|
||||
Next: a short fix plan for the findings, then phases 4 and 5.
|
||||
- **✅ Phase 3: start / stop monitoring by serial (2026-10-23) — built,
|
||||
reviewed, and bench-verified on UM20147 (2026-10-25).** Start acked in
|
||||
|
||||
@@ -515,11 +515,14 @@ Each safety piece arrives with its first real use, so nothing sits untested.
|
||||
the unit takes SFM's connection for the call, sits in "call home data
|
||||
transfer", times out, goes idle and does not retry. With THOR polling, SFM
|
||||
cannot reach the unit at all and does not disturb THOR (A2, step 1).
|
||||
⚠ **Decision owed before merge:** the 5-minute Micromate line hold makes
|
||||
SFM a call-home sink whenever THOR is not holding the line. Options: a
|
||||
much shorter hold or none (hang up after each request), or SFM runs the
|
||||
call-home session itself (the ADR 0003 call-in server). A cool-down alone
|
||||
does not help: the unit does not retry.
|
||||
The 5-minute Micromate line hold makes SFM a call-home sink whenever THOR
|
||||
is not holding the line; a cool-down alone would not help (the unit does
|
||||
not retry).
|
||||
✅ **Decided 2026-10-29 (Brian): keep the hold as it is for now** -- not
|
||||
expected to be a problem in practice -- and the long-term fix is **SFM
|
||||
handling auto call-ins itself** (the ADR 0003 call-in server). This
|
||||
settles the 1c ring-path merge gate; Run B (a poller in THOR's reconnect
|
||||
gap) stays open, not blocking.
|
||||
- Of the items parked for 1c below: **CORS ordering** does not bite the
|
||||
page, which SFM serves itself (same origin); the **Series-4 mic** is not
|
||||
shown (the event list shows geophone peaks only). The rest are server-side
|
||||
|
||||
Reference in new issue
Block a user