docs: the first commands this project originated -- start/stop on UM20147

Bench, 2026-10-25, Brian's go per send: 0x96 acked in 464 ms and read back
monitoring at the first 2 s poll (during the sensor check); 0x97 acked in
116 ms, then 0x49 read a new value 0x01 for ~18 s (inferred: the unit's
call-home attempts after a stop) before idle; two stops to an idle unit acked
in 10 ms and changed nothing.  Retracts "no command has ever been originated"
in place in CLAUDE.md and the reference's untested list; answers the spec's
stop-while-stopped question.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-25 15:56:18 -04:00
1 parent b1c87ecccd
commit 4b911b1c0c
3 files changed
+135 -7

No files matched your search

+16 -5
View File
@@ -10,7 +10,7 @@ pair — lives in `../terra-view/docs/tmi-stack.md`, which is also loaded as
---
## Where things stand (updated 2026-10-19)
## Where things stand (updated 2026-10-25)
Read this first when picking the project back up.
@@ -24,9 +24,15 @@ Read this first when picking the project back up.
by 47x). Read path, event chain, setups, scheduler, monitoring control and
per-event delete are all mapped — **and as of 2026-10-14 so is the inbound
call-home session.** There are no protocol unknowns left.
⚠ **No command has ever been originated against a unit by this project.**
~~⚠ **No command has ever been originated against a unit by this project.**
Every write was performed by THOR while we recorded. That line is worth
keeping.
keeping.~~ **Retracted 2026-10-25:** the first commands this project
originated were `0x96` / `0x97` (start / stop monitoring) to **UM20147 on
2026-10-25**, sent by SFM at the bench with Brian's go for each send — 4
sends, each acked and read back, each audited. Every *other* write
(call-home, setup push, delete, scheduler) is still THOR-only, never sent by
us. Details: `docs/micromate_protocol_reference.md` → *The first commands
this project originated*.
**Series-4 write path, phase 2 is done (2026-10-22):** the write encoder, a
send-side opcode gate and write *plans* for start/stop, call-home enable and
the setup rewrite, reproduced byte for byte against THOR's captured frames.
@@ -123,8 +129,13 @@ Read this first when picking the project back up.
5 events, a waveform that verified, a histogram, one call-up for the whole
sequence. ⚠ The MiniMate header walk is **unproven on a unit; a MiniMate
bench check is owed before the branch merges.** Next: 1c (webapp).
- **✅ Phase 3: start / stop monitoring by serial (2026-10-23) — built and
reviewed offline; the first live send is pending at the bench.** Both
- **✅ Phase 3: start / stop monitoring by serial (2026-10-23) — built,
reviewed, and bench-verified on UM20147 (2026-10-25).** Start acked in
0.46 s and read back as monitoring at the first 2 s poll (during the sensor
check); stop acked in 0.12 s, then `0x49` read a new value **`0x01` for ~18 s**
(inferred: the unit's call-home attempts after a stop — refused as unmeasured
until settled) before idle; a stop while idle is a harmless 10 ms no-op. The
Series-3 path is unproven on a unit (MiniMate bench check owed). Both
series go through one safety core, `sfm/device_access/change.py`: a fresh
identity read, the run state (calling home or never measured is refused),
`dry_run` (the exact frames, nothing sent), a row in the new