docs: the first commands this project originated -- start/stop on UM20147
Bench, 2026-10-25, Brian's go per send: 0x96 acked in 464 ms and read back monitoring at the first 2 s poll (during the sensor check); 0x97 acked in 116 ms, then 0x49 read a new value 0x01 for ~18 s (inferred: the unit's call-home attempts after a stop) before idle; two stops to an idle unit acked in 10 ms and changed nothing. Retracts "no command has ever been originated" in place in CLAUDE.md and the reference's untested list; answers the spec's stop-while-stopped question. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
b1c87ecccd
commit
4b911b1c0c
3 files changed
+135
-7
No files matched your search
@@ -677,6 +677,13 @@ Open questions:
|
||||
on its own, in which case SFM never sees a ring and THOR gets the call
|
||||
while SFM is still connected.
|
||||
- The ack for start/stop when the unit is already in that state.
|
||||
✅ **Answered for stop (2026-10-25, UM20147):** a stop sent to an idle unit
|
||||
is acked `0x68` in 10 ms (twice) and changes nothing: not the state, the
|
||||
events, memory or the screen. Start while already monitoring has not been
|
||||
tried. Also measured at that bench: `0x49` reads `0x01` for ~18 s after a
|
||||
real stop. Its meaning is inferred to be the unit's call-home attempts, and
|
||||
Run A/B can settle it: the inference predicts `0x01` → `0x03` when the modem
|
||||
connects.
|
||||
- The offset rule, and whether `0x68`/`0x82` are required, for the setup push.
|
||||
- Whether the device ever refuses a write while monitoring. Only THOR's policy
|
||||
has been seen.
|
||||
|
||||
Reference in new issue
Block a user