feat(codec): one settings codec for both series, on the shared layout

micromate/setup_fields.py: the fields an operator can change (record
mode, sample rate, interval, record time, geophone trigger, Series 3's
range and -- read-only until benched -- alarm, job number and its report
flag, the four notes by slot), the units' own limits from Instantel's
manuals, field-only byte patching (bit fields bit by bit; Series 3's
[26:28] as Blastware writes it; Series 4's CRC recomputed), the
read-back verdict compared by bytes, and the preview revision.

All 11 Blastware compliance writes reproduce from the block before them
(BE11529's first also shows Blastware re-rendering two mic levels
through its dB value; SFM echoes the unit's bytes); Series 4 keypad
fixtures reproduce pairwise.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-03 21:33:01 -05:00
1 parent 1bb15573fc
commit 5ba72740dd
4 files changed
+712 -1

No files matched your search

+1 -1
View File
@@ -11,7 +11,7 @@
| Date | Section | Change |
|---|---|---|
| 2026-11-03 | SUB 1A / 71 / 69 (settings read and write) | **The settings block, read and written as content (measured, BE9441's 10-26 recording and BE11529's 2026-04-20 captures).** **Read:** unescape each 1A data frame and take `data[11:]`; every frame but the last starts with one `00` that is not content; dropped, the frames join into **2,090 bytes headed by N = 2090: Series IV's `0x1A` content layout** (12 / 12 reads, Blastware's 4 × 512 + 42 and SFM's 1024 + 1024 + 42). The old "stable anchor" `be 80 00 00 00 00` is content `[12:18]` (pre-trigger −0.25 + stop mode Fixed). **Round trip:** the read after each of Blastware's two 10-26 writes equals the image it had just written, all 2,090 bytes (2 / 2). While monitoring, the read returns the device-info block (`0e 'BE9441' …`, 5 / 5). **`[26:28]`:** Blastware writes `00 00` on all 11 writes; the unit reads `01 7f` after a monitoring session (BE9441 10-26, BE11529 4-20 15:19) and sets it by itself; meaning unknown. **The two bytes after the block** (`[2090:2092]` of the 0x71 image) are Blastware's own per-unit constant -- `7c ea` on all nine of BE11529's writes, `0c e9` on both of BE9441's -- not the block's CRC-16/AUG, and in no reply of BE9441's three-hour session; SFM sends `00 00`. **`0x09` `[200:202]`:** Blastware echoed the unit's `8c 76` on all nine April writes; on 10-26 it read `17 17` and wrote `78 76` (read back so); meaning unknown. Code: `minimateplus.protocol.assemble_compliance_content`, `read_compliance_content`; tests `tests/test_s3_settings_read.py`. |
| 2026-11-03 | SUB 1A / 71 / 69 (settings read and write) | **The settings block, read and written as content (measured, BE9441's 10-26 recording and BE11529's 2026-04-20 captures).** **Read:** unescape each 1A data frame and take `data[11:]`; every frame but the last starts with one `00` that is not content; dropped, the frames join into **2,090 bytes headed by N = 2090: Series IV's `0x1A` content layout** (12 / 12 reads, Blastware's 4 × 512 + 42 and SFM's 1024 + 1024 + 42). The old "stable anchor" `be 80 00 00 00 00` is content `[12:18]` (pre-trigger −0.25 + stop mode Fixed). **Round trip:** the read after each of Blastware's two 10-26 writes equals the image it had just written, all 2,090 bytes (2 / 2). While monitoring, the read returns the device-info block (`0e 'BE9441' …`, 5 / 5). **`[26:28]`:** Blastware writes `00 00` on all 11 writes; the unit reads `01 7f` after a monitoring session (BE9441 10-26, BE11529 4-20 15:19) and sets it by itself; meaning unknown. **The two bytes after the block** (`[2090:2092]` of the 0x71 image) are Blastware's own per-unit constant -- `7c ea` on all nine of BE11529's writes, `0c e9` on both of BE9441's -- not the block's CRC-16/AUG, and in no reply of BE9441's three-hour session; SFM sends `00 00`. **`0x09` `[200:202]`:** Blastware echoed the unit's `8c 76` on all nine April writes; on 10-26 it read `17 17` and wrote `78 76` (read back so); meaning unknown. **Blastware re-renders the mic trigger level:** on BE11529's first write (4-20 15:19) the unit read 0.005 and 0.01 psi in its two `MicL` channel blocks (3 and 7; Series 3 carries 8 channel blocks of 48 bytes from `[1708]`, the second four prefixed `0x32`) and Blastware wrote 0.004983 and 0.010058 -- the same levels to its 0.1 dB; every other write left them alone. **Every one of the 11 Blastware writes reproduces** from the block before it with only the fields Blastware changed (plus that re-render and, on 10-26, the mic bit of `[25]`). Code: `minimateplus.protocol.assemble_compliance_content`, `read_compliance_content`, `micromate.setup_fields`; tests `tests/test_s3_settings_read.py`, `tests/test_setup_fields.py`. |
| 2026-11-03 | Appendix D.3.3, D.6.1, D.6.3, D.6.5, D.6.7, §8 | ✅ **File-only decode, second pass (on `dev`).** **D.3.3:** the footer is the file's last 26 bytes (70,041 / 70,041); an earlier stop-time record fooled the first-match search on 14 files, making histograms a day late. Its `[18:24]` is **not** fixed (retracted). **D.6.1:** STRT[18] now picks the codec; the waveform codec had claimed 2018 5 s histograms. **D.6.3:** the job number (flags `k − 9` bit `0x02`, uint16 at `k − 8`; 2,997 / 2,997). **D.6.5:** the PVS² high word is non-zero above 1.28 in/s (retracted "reads 0000"), so the layout check now uses peak ≤ PVS ≤ √3·peak (34,502,955 / 34,502,955); Blastware's "Number of Intervals" is the monitoring time ÷ the interval. **§8:** where the 1995 default-clock events come from. 18 of 88 report fields now match on every DL2 event. |
| 2026-11-03 | call home (SUB 2C / 7E / 7F) | **SFM's call-home write, measured both ways.** SFM's 0x7E image (`write_image` of the 0x2C read with byte 5 set, framed ONCE) and its 0x7F confirm reproduce Blastware's 2026-04-20 enable and disable writes byte for byte (BE11529; `tests/test_s3_call_home_bw_frames.py`). Live on BE9441, idle: a no-op, on and off were all acked (0x81 / 0x80) and read back, and the unit's menu agreed. Only byte 5 changes: no unit-maintained field, unlike Series 4's `[118:120]`. Byte 5 is read from the UNESCAPED block. ⚠ Unescaping is not idempotent, so a built image must never pass through `write_image` again: a call-in time of 16:02-16:04 is `10 02`-`10 04` in the image. ⚠ **While monitoring, the unit answers the 0x2C read with its DEVICE-INFO block** ('Instantel', 'MiniMate Plus', its serial), as it answers 1A. Idle again, minutes later, it returns the call-home block. So a monitoring unit's call-home cannot be read-modify-written; SFM refuses with 'stop monitoring first'. A blind write while monitoring stays untested on purpose. |
| 2026-11-02 | Appendix D.3.1, D.6 (NEW), §15 | ✅ **Event fields SFM reads from the file alone (v0.33.0, plus the range on `dev`).** New D.6 records the bytes and the DL2 verification for each field: the record type `STRT[18]`, the recording-setup block (sample rate, pre-trigger, record time, the four notes), the geophone range (label + 29 in the setup's channel blocks), each histogram interval's PVS², and the mic scale (one count = 0.25 Pa). **Retracted in place:** D.3.1's `STRT[20]` = record time (it is `00` on every DL2 file; the "70 s" SFM used to report was `STRT[18]`, the record-type byte), and the 2026-08-26 reading of sub-minute histogram records as little-endian (big-endian from byte 5 since v0.32.0, #47/#49). **For #48:** the file's copy of the block puts the pre-trigger where the 1A "stable anchor" `be 80 00 00 00 00` sits. In the file, though, it is each event's own pre-trigger, which varies on the same unit on the same day (253–256 samples at 1024 sps), and Blastware reports it per event. So the file says little about whether the live 1A loses its anchor, and #48 stays open. |
+14
View File
@@ -88,6 +88,20 @@ def crc_ok(content: bytes) -> bool:
return _crc16_aug_ccitt(content[: n - 2]) == int.from_bytes(content[n : n + 2], "big")
def with_crc(content: bytes) -> bytes:
"""`content` with its trailing checksum recomputed: CRC-16/AUG-CCITT over
``[0:N-2]``, stored big-endian at ``[N:N+2]`` (the rule `crc_ok` checks).
THOR's write omits the checksum and the unit computes its own; this keeps a
patched block self-consistent so a plan's integrity check still means
something."""
n = int.from_bytes(content[0:2], "big")
if n < 2 or len(content) < n + 2:
raise ValueError(f"block header says {n} but the block is {len(content)} B")
out = bytearray(content)
out[n : n + 2] = _crc16_aug_ccitt(content[: n - 2]).to_bytes(2, "big")
return bytes(out)
def _f32(c: bytes, offset: int) -> float:
return struct.unpack_from(">f", c, offset)[0]
+407
View File
@@ -0,0 +1,407 @@
"""setup_fields.py -- the settings an operator can change, for both series (phase 5).
Pure byte interpretation: no I/O, no device, no `sfm` and no `minimateplus`
imports. Every offset is into the settings block's CONTENT:
* Series 4: the `0x1A` content, 2,092 bytes (N = 2090, then its CRC).
* Series 3: the 1A read assembled by `minimateplus.protocol.
assemble_compliance_content`, 2,090 bytes (N = 2090, no CRC in the read).
**One layout.** Measured 2026-11-03: Blastware's MiniMate compliance image IS
Series IV's `0x1A` content layout (`decode_setup` reads it), and each of
BE11529's nine 2026-04-20 Blastware writes moved exactly the bytes of the field
it changed. Series 4's offsets are from the 47-snapshot keypad pass on UM20147
(2026-10-17/19). Fields measured on one series only are offered on that series
only.
**Limits are the units' own, from Instantel's manuals** (Brian, 2026-11-03: "I
want to use the actual unit limits, not just what we have done in the past"):
* geophone trigger 0.005-10 in/s in steps of 0.001 -- MiniMate Plus manual
716U0101 Rev 15, Appendix *Series III Specifications*; Micromate manual
721U0201 Rev 06, *Geophone Trigger Level* -- and at most the range's full
scale;
* record time: Micromate 1-90 s (*Record Time*); MiniMate up to §4.4's
*Maximum Record Times* for a 1 MB unit, channels 1-4, at the sample rate,
and 13 s in Histogram Combo (§3.8.9);
* job number 1-9999 (both manuals).
What a unit does not take, the read-back shows (`settings_state`).
tests/test_setup_fields.py holds this to Blastware's writes and the keypad
fixtures byte for byte.
"""
from __future__ import annotations
import hashlib
import math
import struct
from typing import Any, Dict, List, Optional, Set
from .setup_block import crc_ok, with_crc
class SettingsValueError(ValueError):
"""A requested change SFM will not make, said plainly. Nothing is sent."""
# ── Layout ──────────────────────────────────────────────────────────────────
_MODE = 5
_SAMPLE_RATE = slice(6, 8) # u16 BE
_HIST_INTERVAL = slice(8, 10) # u16 BE seconds
_RECORD_TIME = 18 # f32 BE seconds
_REPORT_FLAGS = 39 # bit 0x02 = job number on the report (measured both series)
_JOB_SHOWN = 0x02
_JOB_NUMBER = slice(40, 42) # u16 BE
_NOTE_LABEL, _NOTE_VALUE, _NOTE_STRIDE, _NOTES = 122, 144, 64, 4
_NOTE_LABEL_WIDTH, _NOTE_WIDTH = 22, 42
NOTE_MAX = _NOTE_WIDTH - 1 # a NUL always ends the value
_CHANNELS, _CHANNEL_SIZE, _GEOPHONES = 1708, 48, (0, 1, 2)
_CH_RANGE = 29 # u8: 0 Normal (10 in/s), 1 Sensitive (1.25 in/s) -- Series 3, measured
_CH_TRIGGER = 30 # f32 BE, in/s for a geophone
_CH_UNIT = slice(34, 38) # "in." / "in" (the keypad re-renders it); NOT an identifier
_CH_ALARM = 38 # f32 BE -- Series 3, read; a write waits for the bench
_FULL_SCALE = {0: 10.0, 1: 1.25}
_RANGES = {"normal": 0, "sensitive": 1}
# Blastware writes these bytes as a fixed value on every write on record (11 of 11,
# both units); the unit reads `01 7f` there after a monitoring session. Meaning
# unknown -- SFM writes what Blastware writes. Series 3 only.
S3_BLASTWARE_FIXED = {26: b"\x00\x00"}
# A Series-3 alarm-level write has never been seen; the bench measures one, with
# Brian's go, before this turns on.
S3_ALARM_WRITE_MEASURED = False
MODES = {
3: {"single_shot": 0x00, "continuous": 0x01, "histogram": 0x03, "histogram_continuous": 0x04},
4: {"waveform": 0x01, "manual": 0x02, "histogram": 0x03, "combo": 0x04},
}
_MODE_LABELS = {
"single_shot": "Single Shot", "continuous": "Continuous", "histogram": "Histogram",
"histogram_continuous": "Histogram + Continuous", "waveform": "Waveform", "manual": "Manual",
"combo": "Combo",
}
SAMPLE_RATES = (1024, 2048, 4096)
INTERVALS = (2, 5, 15, 60, 300, 900)
TRIGGER_MIN, TRIGGER_MAX, TRIGGER_STEP = 0.005, 10.0, 0.001
RECORD_MIN_S = 1.0
S4_MAX_RECORD_S = 90.0
S3_MAX_RECORD_S = {1024: 104.0, 2048: 52.0, 4096: 26.0}
S3_COMBO_MAX_RECORD_S = 13.0
JOB_MIN, JOB_MAX = 1, 9999
_SERIES_FIELDS = {
3: ("record_mode", "sample_rate", "histogram_interval_s", "record_time_s", "geo_trigger_ips",
"geo_range", "geo_alarm_ips", "job_number", "job_number_shown",
"note_1", "note_2", "note_3", "note_4"),
4: ("record_mode", "sample_rate", "histogram_interval_s", "record_time_s", "geo_trigger_ips",
"job_number", "job_number_shown", "note_1", "note_2", "note_3", "note_4"),
}
_LEVELS = ("geo_trigger_ips", "geo_alarm_ips")
def _ch(k: int) -> int:
return _CHANNELS + _CHANNEL_SIZE * k
def _f32(c: bytes, offset: int) -> float:
return struct.unpack_from(">f", c, offset)[0]
def _shown(v: float) -> float:
"""An f32 as an operator typed it: 0.30000001192 is 0.3."""
return round(v, 6)
def _note_offsets(n: int) -> tuple:
label = _NOTE_LABEL + n * _NOTE_STRIDE
value = _NOTE_VALUE + n * _NOTE_STRIDE
return label, value
def _note_label(c: bytes, n: int) -> str:
start, _ = _note_offsets(n)
raw = c[start:start + _NOTE_LABEL_WIDTH].split(b"\x00")[0]
text = raw.decode("ascii", "replace").strip().rstrip(":").strip()
return text or f"Note {n + 1}"
def _note_value(c: bytes, n: int) -> str:
_, start = _note_offsets(n)
return c[start:start + _NOTE_WIDTH].split(b"\x00")[0].decode("ascii", "replace")
def field_bytes(series: int) -> Dict[str, Set[int]]:
"""Every byte each field may move, by content offset."""
def chans(rel: int, width: int) -> Set[int]:
return {_ch(k) + rel + i for k in _GEOPHONES for i in range(width)}
out = {
"record_mode": {_MODE},
"sample_rate": set(range(6, 8)),
"histogram_interval_s": set(range(8, 10)),
"record_time_s": set(range(_RECORD_TIME, _RECORD_TIME + 4)),
"geo_trigger_ips": chans(_CH_TRIGGER, 4),
"geo_range": chans(_CH_RANGE, 1),
"geo_alarm_ips": chans(_CH_ALARM, 4),
"job_number": set(range(40, 42)),
"job_number_shown": {_REPORT_FLAGS},
}
for n in range(_NOTES):
_, v = _note_offsets(n)
out[f"note_{n + 1}"] = set(range(v, v + _NOTE_WIDTH))
return {f: out[f] for f in _SERIES_FIELDS[series]}
# ── Reading ─────────────────────────────────────────────────────────────────
def _mode_name(c: bytes, series: int) -> str:
code = c[_MODE]
for name, value in MODES[series].items():
if value == code:
return name
return f"unknown(0x{code:02x})"
def _range_code(c: bytes) -> int:
return c[_ch(0) + _CH_RANGE]
def _full_scale(c: bytes, series: int, range_name: Optional[str] = None) -> Optional[float]:
if series == 4:
return _FULL_SCALE[0] # Series 4's range byte is not mapped; 10 in/s is the hardware's
code = _RANGES[range_name] if range_name is not None else _range_code(c)
return _FULL_SCALE.get(code)
def _s3_max_record(rate: int, mode: str) -> Optional[float]:
top = S3_MAX_RECORD_S.get(rate)
if top is None:
return None
return min(top, S3_COMBO_MAX_RECORD_S) if mode == "histogram_continuous" else top
def _unit_string(c: bytes) -> List[str]:
return [c[_ch(k) + _CH_UNIT.start:_ch(k) + _CH_UNIT.stop].replace(b"\x00", b"")
.replace(b".", b"").decode("ascii", "replace") for k in _GEOPHONES]
def editable_fields(content: bytes, series: int) -> List[Dict[str, Any]]:
"""The fields an operator can change, described for a form: field, label,
kind ("number" / "choice" / "text" / "bool"), value, and as relevant unit,
min, max, step, choices [{value, label}], maxlength, readonly."""
c = content
rate = int.from_bytes(c[_SAMPLE_RATE], "big")
mode = _mode_name(c, series)
out: List[Dict[str, Any]] = [
{"field": "record_mode", "label": "Record mode", "kind": "choice", "value": mode,
"choices": [{"value": n, "label": _MODE_LABELS[n]} for n in MODES[series]]},
{"field": "sample_rate", "label": "Sample rate", "kind": "choice", "value": rate, "unit": "sps",
"choices": [{"value": r, "label": f"{r} sps"} for r in SAMPLE_RATES]},
{"field": "histogram_interval_s", "label": "Histogram interval", "kind": "choice",
"value": int.from_bytes(c[_HIST_INTERVAL], "big"),
"choices": [{"value": s, "label": f"{s} s" if s < 60 else f"{s // 60} min"} for s in INTERVALS]},
{"field": "record_time_s", "label": "Record time", "kind": "number", "unit": "s",
"value": _shown(_f32(c, _RECORD_TIME)), "min": RECORD_MIN_S,
"max": S4_MAX_RECORD_S if series == 4 else _s3_max_record(rate, mode)},
{"field": "geo_trigger_ips", "label": "Geophone trigger", "kind": "number", "unit": "in/s",
"value": _shown(_f32(c, _ch(0) + _CH_TRIGGER)), "min": TRIGGER_MIN,
"max": min(TRIGGER_MAX, _full_scale(c, series) or TRIGGER_MAX), "step": TRIGGER_STEP},
]
if series == 3:
code = _range_code(c)
name = next((n for n, v in _RANGES.items() if v == code), f"unknown(0x{code:02x})")
out.append({"field": "geo_range", "label": "Geophone range", "kind": "choice", "value": name,
"choices": [{"value": "normal", "label": "Normal (10 in/s)"},
{"value": "sensitive", "label": "Sensitive (1.25 in/s)"}]})
out.append({"field": "geo_alarm_ips", "label": "Geophone alarm", "kind": "number",
"unit": "in/s", "value": _shown(_f32(c, _ch(0) + _CH_ALARM)),
"min": TRIGGER_MIN, "max": _full_scale(c, 3) or TRIGGER_MAX,
"step": TRIGGER_STEP, "readonly": not S3_ALARM_WRITE_MEASURED})
out.append({"field": "job_number", "label": "Job number", "kind": "number",
"value": int.from_bytes(c[_JOB_NUMBER], "big"), "min": JOB_MIN, "max": JOB_MAX, "step": 1})
out.append({"field": "job_number_shown", "label": "Job number on report", "kind": "bool",
"value": bool(c[_REPORT_FLAGS] & _JOB_SHOWN)})
for n in range(_NOTES):
out.append({"field": f"note_{n + 1}", "label": _note_label(c, n), "kind": "text",
"value": _note_value(c, n), "maxlength": NOTE_MAX})
return out
def field_values(content: bytes, series: int) -> Dict[str, Any]:
return {d["field"]: d["value"] for d in editable_fields(content, series)}
# ── Checking ────────────────────────────────────────────────────────────────
def _number(field: str, v: Any) -> float:
if isinstance(v, bool) or not isinstance(v, (int, float)) or not math.isfinite(v):
raise SettingsValueError(f"{field} must be a number, not {v!r}")
return float(v)
def _integer(field: str, v: Any) -> int:
if isinstance(v, bool) or not isinstance(v, int):
raise SettingsValueError(f"{field} must be a whole number, not {v!r}")
return v
def check_changes(content: bytes, series: int, changes: Dict[str, Any]) -> Dict[str, Any]:
"""The changes, normalised -- or SettingsValueError naming the first one SFM
will not make, and why. Checks names, types and the units' own limits, then
what depends on this unit's block: its unit strings and its range."""
if series not in _SERIES_FIELDS:
raise SettingsValueError(f"Series {series} has no settings SFM can change")
if not isinstance(changes, dict) or not changes:
raise SettingsValueError("no settings to change")
allowed = _SERIES_FIELDS[series]
out: Dict[str, Any] = {}
for field, v in changes.items():
if field not in allowed:
raise SettingsValueError(f"{field} is not a setting SFM can change on a Series {series} unit")
if field == "record_mode":
if v not in MODES[series]:
raise SettingsValueError(f"record_mode must be one of {', '.join(MODES[series])}, not {v!r}")
out[field] = v
elif field == "sample_rate":
if _integer(field, v) not in SAMPLE_RATES:
raise SettingsValueError(f"sample_rate must be one of {SAMPLE_RATES}, not {v}")
out[field] = v
elif field == "histogram_interval_s":
if _integer(field, v) not in INTERVALS:
raise SettingsValueError(f"histogram_interval_s must be one of {INTERVALS} s, not {v}")
out[field] = v
elif field == "geo_range":
if v not in _RANGES:
raise SettingsValueError(f"geo_range must be normal or sensitive, not {v!r}")
out[field] = v
elif field in ("geo_trigger_ips", "geo_alarm_ips"):
if field == "geo_alarm_ips" and not S3_ALARM_WRITE_MEASURED:
raise SettingsValueError("the alarm level is shown but not changed yet: a MiniMate "
"alarm write has never been measured (the bench measures it)")
x = _number(field, v)
if not TRIGGER_MIN <= x <= TRIGGER_MAX:
raise SettingsValueError(f"{field} must be {TRIGGER_MIN}-{TRIGGER_MAX} in/s, not {x}")
if abs(x - round(x, 3)) > 1e-9:
raise SettingsValueError(f"{field} must be in steps of {TRIGGER_STEP} in/s, not {x}")
out[field] = round(x, 3)
elif field == "record_time_s":
out[field] = _number(field, v)
elif field == "job_number":
if not JOB_MIN <= _integer(field, v) <= JOB_MAX:
raise SettingsValueError(f"job_number must be {JOB_MIN}-{JOB_MAX}, not {v}")
out[field] = v
elif field == "job_number_shown":
if not isinstance(v, bool):
raise SettingsValueError(f"job_number_shown must be true or false, not {v!r}")
out[field] = v
else: # note_1 .. note_4
if not isinstance(v, str):
raise SettingsValueError(f"{field} must be text, not {v!r}")
if any(not 0x20 <= ord(ch) <= 0x7E for ch in v):
raise SettingsValueError(f"{field} must be plain printable ASCII (no accents, tabs or "
"line breaks)")
if len(v) > NOTE_MAX:
raise SettingsValueError(f"{field} is {len(v)} characters; the unit holds {NOTE_MAX}")
out[field] = v
# What depends on this unit's block, with the NEW mode / rate / range if they change too.
c = content
if "record_time_s" in out:
t = out["record_time_s"]
if series == 4:
top: Optional[float] = S4_MAX_RECORD_S
else:
rate = out.get("sample_rate", int.from_bytes(c[_SAMPLE_RATE], "big"))
top = _s3_max_record(rate, out.get("record_mode", _mode_name(c, series)))
if top is None:
raise SettingsValueError(f"this unit's sample rate ({rate}) has no record-time limit "
"in the manual -- set the sample rate too")
if not RECORD_MIN_S <= t <= top:
raise SettingsValueError(f"record_time_s must be {RECORD_MIN_S}-{top:g} s here, not {t}")
if any(f in out for f in _LEVELS):
units = _unit_string(c)
if any(u != "in" for u in units):
raise SettingsValueError(f"this unit's geophone channels read {units}, not in/s -- only "
"in/s is measured, so SFM will not change a level")
full = _full_scale(c, series, out.get("geo_range"))
if full is None:
raise SettingsValueError("this unit's geophone range byte is not a value ever measured")
for f in _LEVELS:
if f in out and out[f] > full:
raise SettingsValueError(f"{f} {out[f]} in/s is above the range's full scale ({full} in/s)")
return out
# ── Writing ─────────────────────────────────────────────────────────────────
def encode_setup(content: bytes, series: int, changes: Dict[str, Any]) -> bytes:
"""`content` with only the changed fields' bytes moved. `changes` should
come from check_changes; this patches, it does not judge. Bit fields are
patched bit by bit. Series 3 also writes Blastware's fixed bytes; Series 4
gets its checksum recomputed."""
out = bytearray(content)
for field, v in changes.items():
if field == "record_mode":
out[_MODE] = MODES[series][v]
elif field == "sample_rate":
out[_SAMPLE_RATE] = int(v).to_bytes(2, "big")
elif field == "histogram_interval_s":
out[_HIST_INTERVAL] = int(v).to_bytes(2, "big")
elif field == "record_time_s":
struct.pack_into(">f", out, _RECORD_TIME, float(v))
elif field == "geo_trigger_ips":
for k in _GEOPHONES:
struct.pack_into(">f", out, _ch(k) + _CH_TRIGGER, float(v))
elif field == "geo_alarm_ips":
for k in _GEOPHONES:
struct.pack_into(">f", out, _ch(k) + _CH_ALARM, float(v))
elif field == "geo_range":
for k in _GEOPHONES:
out[_ch(k) + _CH_RANGE] = _RANGES[v]
elif field == "job_number":
out[_JOB_NUMBER] = int(v).to_bytes(2, "big")
elif field == "job_number_shown":
out[_REPORT_FLAGS] = (out[_REPORT_FLAGS] | _JOB_SHOWN) if v else (out[_REPORT_FLAGS] & ~_JOB_SHOWN)
elif field.startswith("note_") and field[5:].isdigit() and 1 <= int(field[5:]) <= _NOTES:
_, start = _note_offsets(int(field[5:]) - 1)
out[start:start + _NOTE_WIDTH] = v.encode("ascii").ljust(_NOTE_WIDTH, b"\x00")
else:
raise SettingsValueError(f"{field} is not a setting SFM can change")
if series == 3:
for offset, value in S3_BLASTWARE_FIXED.items():
out[offset:offset + len(value)] = value
return bytes(out)
return with_crc(bytes(out))
# ── Reading back ────────────────────────────────────────────────────────────
_COMPARED = 2090
def settings_state(before: bytes, written: bytes, now: bytes, *, series: int) -> str:
"""What a read of the unit says about a change, from the bytes alone:
"as asked" (it holds what was written), "unchanged" (it holds what it had),
or "differs". Floats are never compared -- 0.3 is the same f32 both ways.
Series 4 also needs the unit's own checksum to hold. Series 3 bytes that
differ only in Blastware's fixed bytes count as as asked: nothing the operator
asked for is different."""
a, w, n = before[:_COMPARED], written[:_COMPARED], now[:_COMPARED]
if series == 4 and not crc_ok(now):
return "differs"
if n == w:
return "as asked"
if series == 3:
fixed = {o + i for o, v in S3_BLASTWARE_FIXED.items() for i in range(len(v))}
if len(n) == len(w) and all(n[i] == w[i] for i in range(len(n)) if i not in fixed):
return "as asked"
if n == a:
return "unchanged"
return "differs"
def revision(blocks: List[bytes]) -> str:
"""A short fingerprint of the blocks a preview read; a live change must match it."""
return hashlib.sha256(b"".join(bytes(b) for b in blocks)).hexdigest()[:16]
+290
View File
@@ -0,0 +1,290 @@
"""One settings codec for both series (phase 5): the field registry, the limits,
the byte patching, and the read-back verdict.
Ground truth:
* Series 3: Blastware's own compliance writes -- BE11529's nine on 2026-04-20
(bridges/captures/4-20-26) and BE9441's two on 2026-10-26 -- each reproduced
from the block before it with the fields Blastware changed.
* Series 4: the 15 UM20147 / UM12947 keypad fixtures, pairwise.
Limits are the units' own, from Instantel's manuals (Brian, 2026-11-03).
"""
from __future__ import annotations
import glob
import itertools
import os
import re
import struct
import sys
from pathlib import Path
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from micromate import setup_fields as sf # noqa: E402
from micromate.setup_block import crc_ok # noqa: E402
from micromate.setup_fields import ( # noqa: E402
SettingsValueError, check_changes, editable_fields, encode_setup, field_bytes, field_values,
revision, settings_state,
)
from minimateplus.framing import S3FrameParser # noqa: E402
from minimateplus.protocol import assemble_compliance_content, is_compliance_content # noqa: E402
from test_minimate_write_frames import WRITES, _frames, _payload # noqa: E402
ROOT = Path(__file__).resolve().parent.parent
APRIL = ROOT / "bridges" / "captures" / "4-20-26"
S4_FIX = sorted(glob.glob(str(ROOT / "tests" / "fixtures" / "micromate-setup" / "*.bin")))
TEN26 = ROOT / "tests" / "fixtures" / "minimate-bench-10-26-26-histogram"
def _s4(path) -> bytes:
b = Path(path).read_bytes()
return b[-2092:] if len(b) > 2092 else b
def _image(frames) -> bytes:
return b"".join(_payload(f)[16:] for f in frames if _payload(f)[2] == 0x71)
def _reads(replies: bytes) -> list:
"""Each 1A read in a reply stream, assembled (a probe reply starts each)."""
reads, cur = [], None
for f in S3FrameParser().feed(replies):
if f.sub != 0xE5:
continue
if len(f.data) == 11:
cur = []
reads.append(cur)
elif cur is not None:
cur.append(bytes(f.data))
return [assemble_compliance_content(r) for r in reads if r]
def _april_pairs() -> list:
"""(name, before, after) for BE11529's April writes, in time order."""
if not APRIL.is_dir():
return []
files = sorted(glob.glob(str(APRIL / "**" / "raw_bw_*.bin"), recursive=True),
key=lambda p: re.search(r"_(\d{6})_", os.path.basename(p)).group(1))
imgs = [(os.path.basename(p), _image(_frames(Path(p).read_bytes()))) for p in files]
imgs = [(n, i) for n, i in imgs if len(i) >= 2092]
pairs = []
first_name, first_img = imgs[0]
s3 = Path(str(Path(files[0]).parent / first_name.replace("raw_bw_", "raw_s3_")))
whole = [r for r in _reads(s3.read_bytes())] if s3.exists() else []
whole = [r for r in whole if is_compliance_content(r)]
if whole: # the read Blastware took before its first write
pairs.append((first_name, whole[0], first_img))
for (_, a), (n, b) in zip(imgs, imgs[1:]):
pairs.append((n, a, b))
return pairs
def _ten26_pairs() -> list:
reads = _reads((TEN26 / "unit_replies.bin").read_bytes())
i0, i1 = _image(WRITES[0:13]), _image(WRITES[13:26])
return [("10-26 send1", reads[0], i0), ("10-26 send2", i0, i1)]
def _changes(before: bytes, after: bytes, series: int) -> dict:
a, b = field_values(before, series), field_values(after, series)
return {f: b[f] for f in b if b[f] != a[f]}
def _with_mic(encoded: bytes, after: bytes) -> bytes:
"""Test-only: BE9441's 16:26 write also turned the mic on ([25] bit 0x08), a
byte v1 does not offer. Copy that one bit from Blastware's image."""
out = bytearray(encoded)
out[25] = (out[25] & ~0x08) | (after[25] & 0x08)
return bytes(out)
def _blastware_mic_rerender(before: bytes, after: bytes) -> bytes:
"""Blastware's write with the unit's own mic trigger levels put back where
Blastware re-rendered them through its dB value. Measured on BE11529's first
write of 2026-04-20 (15:19): the unit read 0.005 and 0.01 psi (channel blocks
3 and 7, `MicL`), Blastware wrote 0.004983 and 0.010058 -- the same levels to
its 0.1 dB. SFM echoes the unit's bytes instead; every other byte must match."""
out = bytearray(after)
for k in range(8):
o = 1708 + 48 * k
if before[o:o + 4] != b"MicL":
continue
a = struct.unpack_from(">f", before, o + 30)[0]
b = struct.unpack_from(">f", after, o + 30)[0]
if a != b and abs(a - b) <= 0.01 * abs(a): # 0.1 dB is 1.2 % in pressure
out[o + 30:o + 34] = before[o + 30:o + 34]
return bytes(out)
S3_PAIRS = _april_pairs() + _ten26_pairs()
@pytest.mark.parametrize("name,before,after", S3_PAIRS, ids=[p[0] for p in S3_PAIRS])
def test_s3_reproduces_every_blastware_write(name, before, after):
out = _with_mic(encode_setup(before[:2090], 3, _changes(before, after, 3)), after)
assert out[:2090] == _blastware_mic_rerender(before, after)[:2090]
def test_the_blastware_writes_are_all_here():
if not APRIL.is_dir():
pytest.skip("bridges/captures is not on this machine")
assert len(S3_PAIRS) >= 10 # 8 April pairs (+1 if its first read is whole) and 2 on 10-26
def _diffs(a: bytes, b: bytes) -> set:
return {i for i in range(2090) if a[i] != b[i]}
def test_s4_fixture_pairs_reproduce():
fb = field_bytes(4)
covered = 0
for pa, pb in itertools.permutations(S4_FIX, 2):
a, b = _s4(pa), _s4(pb)
d = _diffs(a, b)
if not d:
continue
touched = {f for f, bs in fb.items() if bs & d}
if d - set().union(*(fb[f] for f in touched)):
continue # a byte outside the registry moved: not a field-only pair
out = encode_setup(a, 4, {f: field_values(b, 4)[f] for f in touched})
assert out == b, (os.path.basename(pa), os.path.basename(pb))
covered += 1
assert covered >= 10
# ── limits (the units' own) ──────────────────────────────────────────────────
S3_BLOCK = _ten26_pairs()[1][2][:2090] # BE9441, 4096 sps, histogram, Normal range
S4_BLOCK = _s4(ROOT / "tests" / "fixtures" / "micromate-setup" / "um20147_baseline.bin")
def _refused(block, series, changes):
with pytest.raises(SettingsValueError):
check_changes(block, series, changes)
def test_trigger_checked_against_the_new_range():
_refused(S3_BLOCK, 3, {"geo_range": "sensitive", "geo_trigger_ips": 2.0})
assert check_changes(S3_BLOCK, 3, {"geo_range": "sensitive", "geo_trigger_ips": 1.25})
assert check_changes(S3_BLOCK, 3, {"geo_trigger_ips": 2.0})
def test_limits_refuse_outside_values():
for v in (0.004, 10.001, 0.3005):
_refused(S4_BLOCK, 4, {"geo_trigger_ips": v})
for v in (0, 10000):
_refused(S4_BLOCK, 4, {"job_number": v})
for v in (0.9, 90.1):
_refused(S4_BLOCK, 4, {"record_time_s": v})
assert check_changes(S4_BLOCK, 4, {"record_time_s": 90.0})
assert check_changes(S3_BLOCK, 3, {"record_time_s": 26.0}) # 4096 sps
_refused(S3_BLOCK, 3, {"record_time_s": 26.1})
assert check_changes(S3_BLOCK, 3, {"record_mode": "histogram_continuous", "record_time_s": 13.0})
_refused(S3_BLOCK, 3, {"record_mode": "histogram_continuous", "record_time_s": 13.1})
assert check_changes(S3_BLOCK, 3, {"sample_rate": 1024, "record_time_s": 100.0}) # the new rate counts
_refused(S3_BLOCK, 3, {"sample_rate": 8192})
_refused(S3_BLOCK, 3, {"histogram_interval_s": 30})
_refused(S3_BLOCK, 3, {"geo_trigger_ips": "0.3"}) # a number, not a string
_refused(S3_BLOCK, 3, {"job_number": True})
def test_field_not_offered_for_the_series():
with pytest.raises(SettingsValueError, match="Series 4"):
check_changes(S4_BLOCK, 4, {"geo_range": "sensitive"})
_refused(S4_BLOCK, 4, {"no_such_field": 1})
def test_alarm_is_read_only_until_measured():
assert sf.S3_ALARM_WRITE_MEASURED is False
_refused(S3_BLOCK, 3, {"geo_alarm_ips": 1.0})
alarm = next(d for d in editable_fields(S3_BLOCK, 3) if d["field"] == "geo_alarm_ips")
assert alarm["readonly"] is True
def _with_unit(block: bytes, unit: bytes) -> bytes:
out = bytearray(block)
for k in range(3):
out[1708 + 48 * k + 34: 1708 + 48 * k + 38] = unit
return bytes(out)
def test_metric_unit_string_refuses_level_writes():
_refused(_with_unit(S4_BLOCK, b"mm\x00\x00"), 4, {"geo_trigger_ips": 0.3})
assert check_changes(_with_unit(S4_BLOCK, b"in.\x00"), 4, {"geo_trigger_ips": 0.3})
assert check_changes(_with_unit(S4_BLOCK, b"in\x00\x00"), 4, {"geo_trigger_ips": 0.3})
assert check_changes(_with_unit(S4_BLOCK, b"mm\x00\x00"), 4, {"job_number": 5}) # not a level
def test_note_edges():
assert check_changes(S4_BLOCK, 4, {"note_1": ""})
assert check_changes(S4_BLOCK, 4, {"note_1": "x" * 41})
_refused(S4_BLOCK, 4, {"note_1": "x" * 42})
_refused(S4_BLOCK, 4, {"note_1": "café"})
_refused(S4_BLOCK, 4, {"note_1": "tab\there"})
out = encode_setup(S4_BLOCK, 4, {"note_1": ""})
assert out[144:186] == bytes(42)
def test_note_labels_are_never_written():
out = encode_setup(S4_BLOCK, 4, {"note_2": "Loc 9 - North wall"})
assert _diffs(S4_BLOCK, out) <= set(range(208, 250))
assert out[186:208] == S4_BLOCK[186:208]
def test_bit_fields_keep_unknown_bits():
b = bytearray(S4_BLOCK)
b[39] = 0x81
assert encode_setup(bytes(b), 4, {"job_number_shown": True})[39] == 0x83
b[39] = 0x83
assert encode_setup(bytes(b), 4, {"job_number_shown": False})[39] == 0x81
def test_s3_fixed_bytes():
b = bytearray(S3_BLOCK)
b[26:28] = b"\x01\x7f"
assert encode_setup(bytes(b), 3, {"job_number": 7})[26:28] == b"\x00\x00"
def test_s4_encode_recomputes_the_crc():
out = encode_setup(S4_BLOCK, 4, {"job_number": 7})
assert crc_ok(out) and out[40:42] == (7).to_bytes(2, "big")
def test_f32_values_read_back_as_asked():
written = encode_setup(S4_BLOCK, 4, {"geo_trigger_ips": 0.3})
assert struct.unpack_from(">f", written, 1708 + 30)[0] != 0.3 # f32: 0.30000001192
assert field_values(written, 4)["geo_trigger_ips"] == 0.3
assert settings_state(S4_BLOCK, written, written, series=4) == "as asked"
def test_settings_state():
written = encode_setup(S4_BLOCK, 4, {"job_number": 7})
assert settings_state(S4_BLOCK, written, S4_BLOCK, series=4) == "unchanged"
other = encode_setup(S4_BLOCK, 4, {"job_number": 8})
assert settings_state(S4_BLOCK, written, other, series=4) == "differs"
bad = bytearray(written)
bad[2091] ^= 0xFF
assert settings_state(S4_BLOCK, written, bytes(bad), series=4) == "differs"
# Series 3: a block that differs from its image only in Blastware's fixed bytes is as asked
before = bytearray(S3_BLOCK)
before[26:28] = b"\x01\x7f"
before = bytes(before)
assert settings_state(before, encode_setup(before, 3, {}), before, series=3) == "as asked"
def test_revision_is_stable_and_content_sensitive():
r = revision([S4_BLOCK, b"name"])
assert r == revision([S4_BLOCK, b"name"]) and len(r) == 16
assert r != revision([S4_BLOCK, b"nams"])
def test_editable_fields_describe_both_series():
s3 = {d["field"]: d for d in editable_fields(S3_BLOCK, 3)}
s4 = {d["field"]: d for d in editable_fields(S4_BLOCK, 4)}
assert {"geo_range", "geo_alarm_ips"} <= set(s3) and not {"geo_range", "geo_alarm_ips"} & set(s4)
assert s3["record_mode"]["value"] == "histogram" and s3["sample_rate"]["value"] == 4096
assert s3["note_1"]["label"] == "Project" and s3["note_1"]["maxlength"] == 41
assert s4["note_1"]["label"] == "Location"
assert s4["record_time_s"]["max"] == 90.0 and s3["record_time_s"]["max"] == 26.0