feat(codec): one settings codec for both series, on the shared layout
micromate/setup_fields.py: the fields an operator can change (record mode, sample rate, interval, record time, geophone trigger, Series 3's range and -- read-only until benched -- alarm, job number and its report flag, the four notes by slot), the units' own limits from Instantel's manuals, field-only byte patching (bit fields bit by bit; Series 3's [26:28] as Blastware writes it; Series 4's CRC recomputed), the read-back verdict compared by bytes, and the preview revision. All 11 Blastware compliance writes reproduce from the block before them (BE11529's first also shows Blastware re-rendering two mic levels through its dB value; SFM echoes the unit's bytes); Series 4 keypad fixtures reproduce pairwise. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
1bb15573fc
commit
5ba72740dd
4 files changed
+712
-1
No files matched your search
@@ -11,7 +11,7 @@
|
||||
|
||||
| Date | Section | Change |
|
||||
|---|---|---|
|
||||
| 2026-11-03 | SUB 1A / 71 / 69 (settings read and write) | **The settings block, read and written as content (measured, BE9441's 10-26 recording and BE11529's 2026-04-20 captures).** **Read:** unescape each 1A data frame and take `data[11:]`; every frame but the last starts with one `00` that is not content; dropped, the frames join into **2,090 bytes headed by N = 2090: Series IV's `0x1A` content layout** (12 / 12 reads, Blastware's 4 × 512 + 42 and SFM's 1024 + 1024 + 42). The old "stable anchor" `be 80 00 00 00 00` is content `[12:18]` (pre-trigger −0.25 + stop mode Fixed). **Round trip:** the read after each of Blastware's two 10-26 writes equals the image it had just written, all 2,090 bytes (2 / 2). While monitoring, the read returns the device-info block (`0e 'BE9441' …`, 5 / 5). **`[26:28]`:** Blastware writes `00 00` on all 11 writes; the unit reads `01 7f` after a monitoring session (BE9441 10-26, BE11529 4-20 15:19) and sets it by itself; meaning unknown. **The two bytes after the block** (`[2090:2092]` of the 0x71 image) are Blastware's own per-unit constant -- `7c ea` on all nine of BE11529's writes, `0c e9` on both of BE9441's -- not the block's CRC-16/AUG, and in no reply of BE9441's three-hour session; SFM sends `00 00`. **`0x09` `[200:202]`:** Blastware echoed the unit's `8c 76` on all nine April writes; on 10-26 it read `17 17` and wrote `78 76` (read back so); meaning unknown. Code: `minimateplus.protocol.assemble_compliance_content`, `read_compliance_content`; tests `tests/test_s3_settings_read.py`. |
|
||||
| 2026-11-03 | SUB 1A / 71 / 69 (settings read and write) | **The settings block, read and written as content (measured, BE9441's 10-26 recording and BE11529's 2026-04-20 captures).** **Read:** unescape each 1A data frame and take `data[11:]`; every frame but the last starts with one `00` that is not content; dropped, the frames join into **2,090 bytes headed by N = 2090: Series IV's `0x1A` content layout** (12 / 12 reads, Blastware's 4 × 512 + 42 and SFM's 1024 + 1024 + 42). The old "stable anchor" `be 80 00 00 00 00` is content `[12:18]` (pre-trigger −0.25 + stop mode Fixed). **Round trip:** the read after each of Blastware's two 10-26 writes equals the image it had just written, all 2,090 bytes (2 / 2). While monitoring, the read returns the device-info block (`0e 'BE9441' …`, 5 / 5). **`[26:28]`:** Blastware writes `00 00` on all 11 writes; the unit reads `01 7f` after a monitoring session (BE9441 10-26, BE11529 4-20 15:19) and sets it by itself; meaning unknown. **The two bytes after the block** (`[2090:2092]` of the 0x71 image) are Blastware's own per-unit constant -- `7c ea` on all nine of BE11529's writes, `0c e9` on both of BE9441's -- not the block's CRC-16/AUG, and in no reply of BE9441's three-hour session; SFM sends `00 00`. **`0x09` `[200:202]`:** Blastware echoed the unit's `8c 76` on all nine April writes; on 10-26 it read `17 17` and wrote `78 76` (read back so); meaning unknown. **Blastware re-renders the mic trigger level:** on BE11529's first write (4-20 15:19) the unit read 0.005 and 0.01 psi in its two `MicL` channel blocks (3 and 7; Series 3 carries 8 channel blocks of 48 bytes from `[1708]`, the second four prefixed `0x32`) and Blastware wrote 0.004983 and 0.010058 -- the same levels to its 0.1 dB; every other write left them alone. **Every one of the 11 Blastware writes reproduces** from the block before it with only the fields Blastware changed (plus that re-render and, on 10-26, the mic bit of `[25]`). Code: `minimateplus.protocol.assemble_compliance_content`, `read_compliance_content`, `micromate.setup_fields`; tests `tests/test_s3_settings_read.py`, `tests/test_setup_fields.py`. |
|
||||
| 2026-11-03 | Appendix D.3.3, D.6.1, D.6.3, D.6.5, D.6.7, §8 | ✅ **File-only decode, second pass (on `dev`).** **D.3.3:** the footer is the file's last 26 bytes (70,041 / 70,041); an earlier stop-time record fooled the first-match search on 14 files, making histograms a day late. Its `[18:24]` is **not** fixed (retracted). **D.6.1:** STRT[18] now picks the codec; the waveform codec had claimed 2018 5 s histograms. **D.6.3:** the job number (flags `k − 9` bit `0x02`, uint16 at `k − 8`; 2,997 / 2,997). **D.6.5:** the PVS² high word is non-zero above 1.28 in/s (retracted "reads 0000"), so the layout check now uses peak ≤ PVS ≤ √3·peak (34,502,955 / 34,502,955); Blastware's "Number of Intervals" is the monitoring time ÷ the interval. **§8:** where the 1995 default-clock events come from. 18 of 88 report fields now match on every DL2 event. |
|
||||
| 2026-11-03 | call home (SUB 2C / 7E / 7F) | **SFM's call-home write, measured both ways.** SFM's 0x7E image (`write_image` of the 0x2C read with byte 5 set, framed ONCE) and its 0x7F confirm reproduce Blastware's 2026-04-20 enable and disable writes byte for byte (BE11529; `tests/test_s3_call_home_bw_frames.py`). Live on BE9441, idle: a no-op, on and off were all acked (0x81 / 0x80) and read back, and the unit's menu agreed. Only byte 5 changes: no unit-maintained field, unlike Series 4's `[118:120]`. Byte 5 is read from the UNESCAPED block. ⚠ Unescaping is not idempotent, so a built image must never pass through `write_image` again: a call-in time of 16:02-16:04 is `10 02`-`10 04` in the image. ⚠ **While monitoring, the unit answers the 0x2C read with its DEVICE-INFO block** ('Instantel', 'MiniMate Plus', its serial), as it answers 1A. Idle again, minutes later, it returns the call-home block. So a monitoring unit's call-home cannot be read-modify-written; SFM refuses with 'stop monitoring first'. A blind write while monitoring stays untested on purpose. |
|
||||
| 2026-11-02 | Appendix D.3.1, D.6 (NEW), §15 | ✅ **Event fields SFM reads from the file alone (v0.33.0, plus the range on `dev`).** New D.6 records the bytes and the DL2 verification for each field: the record type `STRT[18]`, the recording-setup block (sample rate, pre-trigger, record time, the four notes), the geophone range (label + 29 in the setup's channel blocks), each histogram interval's PVS², and the mic scale (one count = 0.25 Pa). **Retracted in place:** D.3.1's `STRT[20]` = record time (it is `00` on every DL2 file; the "70 s" SFM used to report was `STRT[18]`, the record-type byte), and the 2026-08-26 reading of sub-minute histogram records as little-endian (big-endian from byte 5 since v0.32.0, #47/#49). **For #48:** the file's copy of the block puts the pre-trigger where the 1A "stable anchor" `be 80 00 00 00 00` sits. In the file, though, it is each event's own pre-trigger, which varies on the same unit on the same day (253–256 samples at 1024 sps), and Blastware reports it per event. So the file says little about whether the live 1A loses its anchor, and #48 stays open. |
|
||||
|
||||
Reference in new issue