feat(checker): a histogram row printing one unit in both mic columns is the mixed-units case

The ~20 histograms with one mic interval off were Blastware printing
the same number in both mic columns of a row: I145HKWT.DY0H row 672
reads 95.92 under psi(L) and dB(L) (count 5: dB), S353K894.OE0H rows
106 and 608 read 0.000 under both (count 2: psi).  SFM's count agrees
with the neighbouring rows and with the other column.  mic-units-mixed
now covers the interval mic columns too; a column names its own unit.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-09 14:45:41 -05:00
1 parent 0b6150adb5
commit 6818e3023e
6 files changed
+4779 -3

No files matched your search

+8 -3
View File
@@ -177,7 +177,9 @@ def _mic_units_mixed(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
peak = max((abs(c) for c in counts), default=None)
return alt is not None and peak is not None and not _differs(alt(peak), res.bw or "")
got = series_pairs(sfm, ref, res.field)
alt = _other_mic_unit(sfm, _mic_table_units(ref))
# An interval column names its own unit; a sample table says it in its cells.
units = res.field if res.field.startswith("intervals.") else _mic_table_units(ref)
alt = _other_mic_unit(sfm, units)
if got is None or got[1] or alt is None:
return False
differing = [(j, cell) for j, cell, v in got[0] if _differs(v, cell)]
@@ -187,13 +189,16 @@ def _mic_units_mixed(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
MIC_UNITS_MIXED = Carveout(
id="mic-units-mixed",
fields=("MicLPSPL", "samples.MicL"),
fields=("MicLPSPL", "samples.MicL", "intervals.MicL Peak psi(L)", "intervals.MicL Peak dB(L)"),
evidence=("Blastware's dB(L) / psi(L) labels do not hold for the mic on every report: 7 DL2 "
"reports print the mic peak in dB under a psi line, 3 the reverse, and some mix the "
"two inside one column -- K441L9IN.OT0W prints psi '0.000' / '-0.000' for counts of 1 "
"to 3 in a dB table, S353JTHU.DT0W psi rows then dB rows. On 19 DL2 events (14 "
"sample tables, 5 peaks) every mic cell SFM disagrees with is SFM's own value in the "
"other unit; a cell matching neither is still a mismatch. 2026-11-09."),
"other unit; a cell matching neither is still a mismatch. A histogram row can print "
"one unit in both its mic columns: I145HKWT.DY0H row 672 reads 95.92 under psi(L) "
"and dB(L) (count 5, dB), S353K894.OE0H rows 106 and 608 0.000 under both (count 2, "
"psi). 2026-11-09."),
applies=_mic_units_mixed,
)
BIN
View File
Binary file not shown.
File diff suppressed because it is too large. Load diff
BIN
View File
Binary file not shown.
File diff suppressed because it is too large. Load diff
+9
View File
@@ -544,3 +544,12 @@ def test_the_mixed_units_carveout_needs_every_cell_in_one_unit_or_the_other():
ref.sample_rows[0][i] = "50.00" # neither SFM's dB nor its psi
res = {r.field: r for r in compare(sfm_side(path.read_bytes()), ref, CARVEOUTS)}
assert res["samples.MicL"].verdict == "mismatch"
@pytest.mark.parametrize("path,column", [
(_UL / "I145HKWT.DY0H", "MicL Peak psi(L)"), # row 672: 95.92 in both mic columns (count 5: dB)
(_UL / "S353K894.OE0H", "MicL Peak dB(L)"), # rows 106, 608: 0.000 in both (count 2: psi)
])
def test_an_interval_printing_one_unit_in_both_mic_columns_is_accepted(path, column):
r = _res(path)[f"intervals.{column}"]
assert (r.verdict, r.carveout) == ("accepted", "mic-units-mixed"), r