- #6 Config tab by serial: the empty legacy edit form stays hidden (settings are read-only until phase 5); the settings box shows from the start, 'Not read yet', and a different unit's settings are never left on screen. - #10 A start/stop that went out but was not confirmed is no longer called 'failed'. The route now adds 'sent' (acknowledged / unknown) and 'audit_id' to a ChangeUnconfirmed -- same status, same message -- and the page says 'Start monitoring not confirmed: <what happened, audit record>'. - #12 Device tab by serial: the empty legacy Compliance/Project tables are hidden behind a pointer to the Config tab; a Micromate's Firmware card reads 'Thor line (version not read)' (its version string is in 0x01, undecoded). - #16 A 504 with nothing sent adds: the connection opened, so the modem is reachable -- another program (THOR or Blastware) may be holding the line, or the unit is busy. Measured 2026-10-29: THOR polling leaves SFM a 0-byte 504. New logic lives in sfm/static/device_routing.js (firmwareLabel, deviceErrorText, changeErrorText, serialPanes) under Node tests; the page glue in sfm_webapp.js only applies them. Checked in jsdom against the real page (served at a fake origin, /static from disk): all four, legacy mode unchanged, no script errors. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
2b886c4f39
commit
8123d75d72
7 files changed
+163
-22
No files matched your search
@@ -681,7 +681,9 @@ a short plan; #14 waits for the line-hold decision above.
|
||||
4. List vector sum 0 / −0 for three events whose peaks reach 1.08 in/s --
|
||||
suspected escapes in the `0C` record (not checked).
|
||||
5. Stored S3 event: client "Terra-Mechanic" (last letter missing) -- unexplained.
|
||||
6. Page: the Config tab shows the empty write form until Read in serial mode.
|
||||
6. ✅ **Fixed 2026-11-02 (Batch 2):** by serial the edit form stays hidden and the settings
|
||||
box shows from the start ("Not read yet"); another unit's settings are cleared.
|
||||
Page: the Config tab shows the empty write form until Read in serial mode.
|
||||
7. `/db/events` 500 "database is locked" on the first page load against a new DB.
|
||||
8. ✅ **Fixed `9492e49`**, plus `3a1d34a` ("already stored" also matches the Blastware
|
||||
name: a histogram's row sits a second off its 0C time). The download carries the assembled Blastware file and is
|
||||
@@ -704,10 +706,14 @@ a short plan; #14 waits for the line-hold decision above.
|
||||
**S3 start over a modem:** the line dropped during the sensor check, the
|
||||
read-back hit `Broken pipe` and did not reconnect → 503 though the start
|
||||
worked. Fix: reconnect for the read-back (reads only; the send stays single).
|
||||
10. Page: "Start monitoring failed:" on a sent-but-unconfirmed change -- wording.
|
||||
10. ✅ **Fixed 2026-11-02 (Batch 2):** the start/stop route adds `sent` + `audit_id` to a
|
||||
ChangeUnconfirmed (same status and message); the page says "… not confirmed:".
|
||||
Page: "Start monitoring failed:" on a sent-but-unconfirmed change -- wording.
|
||||
11. S3 stop ~19 s, 11.6 s of it the identity check (a full connect) vs ~1 s for a
|
||||
serial-only read. **Identified only** (speed is secondary to reliability).
|
||||
12. Page, serial mode: the Device tab's empty legacy compliance table; S4
|
||||
12. ✅ **Fixed 2026-11-02 (Batch 2):** by serial the legacy tables are hidden behind a
|
||||
pointer to the Config tab; a Micromate's Firmware reads "Thor line (version not read)".
|
||||
Page, serial mode: the Device tab's empty legacy compliance table; S4
|
||||
Firmware "—" (should say Thor line).
|
||||
13. S4 mic in the event's peaks "0.0 dBL" vs 96.54 dB(L) in the file -- the
|
||||
`0x0C` mic denormal parked above, now visible.
|
||||
@@ -717,7 +723,10 @@ a short plan; #14 waits for the line-hold decision above.
|
||||
**RETRACTED 2026-10-29: not a bug.** `sent` is documented as 1 acknowledged, 0
|
||||
nothing sent, NULL unknown (`sfm/database.py`, `change.py`); a frame answered by a
|
||||
ring instead of its ack is exactly unknown, and the row's `error` says it was sent.
|
||||
16. Page: a 504 on a unit THOR holds should say "connected, but no reply --
|
||||
16. ✅ **Fixed 2026-11-02 (Batch 2):** a 504 with nothing sent adds "the connection opened,
|
||||
so the modem is reachable — another program (THOR or Blastware) may be holding
|
||||
this unit's line, or the unit is busy".
|
||||
Page: a 504 on a unit THOR holds should say "connected, but no reply --
|
||||
another program may be holding this unit's line".
|
||||
17. ✅ **Range part fixed 2026-11-02:** a MiniMate downloaded *while monitoring*
|
||||
answers 1A with its device-info block, so no range was read and the stored
|
||||
|
||||
Reference in new issue
Block a user