fix(sfm): page polish from the 1c bench -- #6, #10, #12, #16 (Batch 2)

- #6 Config tab by serial: the empty legacy edit form stays hidden (settings
  are read-only until phase 5); the settings box shows from the start, 'Not read
  yet', and a different unit's settings are never left on screen.
- #10 A start/stop that went out but was not confirmed is no longer called
  'failed'.  The route now adds 'sent' (acknowledged / unknown) and 'audit_id'
  to a ChangeUnconfirmed -- same status, same message -- and the page says
  'Start monitoring not confirmed: <what happened, audit record>'.
- #12 Device tab by serial: the empty legacy Compliance/Project tables are
  hidden behind a pointer to the Config tab; a Micromate's Firmware card reads
  'Thor line (version not read)' (its version string is in 0x01, undecoded).
- #16 A 504 with nothing sent adds: the connection opened, so the modem is
  reachable -- another program (THOR or Blastware) may be holding the line, or
  the unit is busy.  Measured 2026-10-29: THOR polling leaves SFM a 0-byte 504.

New logic lives in sfm/static/device_routing.js (firmwareLabel,
deviceErrorText, changeErrorText, serialPanes) under Node tests; the page glue
in sfm_webapp.js only applies them.  Checked in jsdom against the real page
(served at a fake origin, /static from disk): all four, legacy mode unchanged,
no script errors.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-02 16:22:22 -05:00
1 parent 2b886c4f39
commit 8123d75d72
7 files changed
+163 -22

No files matched your search

+25 -6
View File
@@ -73,9 +73,7 @@ async function deviceFetch(action, params = {}, opts = {}) {
const r = await deviceRequest(action, params, opts);
const body = await r.json().catch(() => ({}));
if (!r.ok) {
const d = body.detail;
const err = new Error(body.outcome ? changeSummary(body)
: typeof d === 'string' ? d : d ? (d.message || JSON.stringify(d)) : r.statusText);
const err = new Error(deviceErrorText(r.status, body, currentUnit(), r.statusText));
err.status = r.status; err.body = body;
throw err;
}
@@ -102,6 +100,22 @@ function applyControls() {
chr.title = s4;
document.getElementById('ch-series-note').textContent = s4;
setMonitorButtons();
applyConfigPanes();
}
// The Config tab by serial (#6): settings are read-only until phase 5, so the
// empty legacy edit form stays hidden and the settings box shows from the start.
// A different unit's settings are never left on screen.
let settingsShownFor = null;
function applyConfigPanes() {
const serial = normSerial(currentUnit().serial);
const p = serialPanes(Boolean(serial), Boolean(serial) && settingsShownFor === serial);
document.getElementById('cfg-form').style.display = p.configForm ? '' : 'none';
document.getElementById('cfg-settings').style.display = p.settingsBox ? 'block' : 'none';
if (p.settingsPlaceholder) {
settingsShownFor = null;
renderTextTable('cfg-settings-table', [['Settings', 'Not read yet — press Read from Device']]);
}
}
async function hangUp() {
@@ -430,8 +444,7 @@ async function changeMonitoring(action) {
if (body.outcome) {
setStatus(changeSummary(body), r.ok ? 'ok' : 'error');
} else {
const d = body.detail;
setStatus(`${verb} monitoring failed: ${typeof d === 'string' ? d : d ? JSON.stringify(d) : r.statusText}`, 'error');
setStatus(changeErrorText(verb, r.status, body, currentUnit(), r.statusText), 'error');
}
} catch (e) {
// No reply is not "nothing sent": the request may have reached the unit.
@@ -454,7 +467,7 @@ function populateDeviceTab() {
const cardData = [
{ label:'Serial Number', value: unitInfo.serial || '—' },
{ label:'Series', value: confirmedSeries(currentUnit()) ?? '—' },
{ label:'Firmware', value: unitInfo.firmware_version || unitInfo.firmware || '—' },
{ label:'Firmware', value: firmwareLabel(unitInfo) },
{ label:'DSP', value: unitInfo.dsp_version || (unitInfo.detail || {}).dsp_version || '—' },
{ label:'Model', value: unitInfo.model || '—' },
{ label:'Manufacturer', value: unitInfo.manufacturer || (unitInfo.detail || {}).manufacturer || '—' },
@@ -471,6 +484,11 @@ function populateDeviceTab() {
cards.appendChild(c);
}
// The legacy settings tables are empty by serial (#12); the Config tab reads them.
const legacy = serialPanes(serialMode(), false).legacyDeviceTables;
document.getElementById('dev-legacy-tables').hidden = !legacy;
document.getElementById('dev-serial-note').hidden = legacy;
// Compliance table
const cc = unitInfo.compliance_config || {};
const RECORDING_MODE_LABELS = {0: 'Single Shot', 1: 'Continuous', 3: 'Histogram', 4: 'Histogram + Continuous'};
@@ -713,6 +731,7 @@ async function readSettingsBySerial() {
try {
const st = await deviceFetch('settings');
renderTextTable('cfg-settings-table', settingsRows(st));
settingsShownFor = normSerial(st.serial);
document.getElementById('cfg-settings').style.display = 'block';
document.getElementById('cfg-form').style.display = 'none';
setCfgStatus(`Settings read from ${st.serial}.`, 'ok');