fix(sfm): page polish from the 1c bench -- #6, #10, #12, #16 (Batch 2)

- #6 Config tab by serial: the empty legacy edit form stays hidden (settings
  are read-only until phase 5); the settings box shows from the start, 'Not read
  yet', and a different unit's settings are never left on screen.
- #10 A start/stop that went out but was not confirmed is no longer called
  'failed'.  The route now adds 'sent' (acknowledged / unknown) and 'audit_id'
  to a ChangeUnconfirmed -- same status, same message -- and the page says
  'Start monitoring not confirmed: <what happened, audit record>'.
- #12 Device tab by serial: the empty legacy Compliance/Project tables are
  hidden behind a pointer to the Config tab; a Micromate's Firmware card reads
  'Thor line (version not read)' (its version string is in 0x01, undecoded).
- #16 A 504 with nothing sent adds: the connection opened, so the modem is
  reachable -- another program (THOR or Blastware) may be holding the line, or
  the unit is busy.  Measured 2026-10-29: THOR polling leaves SFM a 0-byte 504.

New logic lives in sfm/static/device_routing.js (firmwareLabel,
deviceErrorText, changeErrorText, serialPanes) under Node tests; the page glue
in sfm_webapp.js only applies them.  Checked in jsdom against the real page
(served at a fake origin, /static from disk): all four, legacy mode unchanged,
no script errors.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-02 16:22:22 -05:00
1 parent 2b886c4f39
commit 8123d75d72
7 files changed
+163 -22

No files matched your search

+9 -4
View File
@@ -2,6 +2,8 @@
FastAPI Query() defaults are FieldInfo objects, not values."""
from __future__ import annotations
import json
import os
import sys
@@ -418,10 +420,13 @@ def test_a_change_unconfirmed_keeps_its_cause_status_and_names_the_audit_record(
"failed: silent -- audit record c7", audit_id="c7", sent="acknowledged",
http_status=504)
monkeypatch.setattr(srv, "_device_access_instance", Raises())
with pytest.raises(HTTPException) as e:
srv.device_monitor_start(**CH)
assert e.value.status_code == 504
assert "audit record c7" in e.value.detail
resp = srv.device_monitor_start(**CH)
assert resp.status_code == 504 # the cause's status, unchanged
body = json.loads(resp.body)
assert "audit record c7" in body["detail"]
# #10 (2026-11-02): the page tells "may have been sent" from "nothing sent" by
# these, not by matching the message.
assert (body["sent"], body["audit_id"]) == ("acknowledged", "c7")
def test_device_commands_normalises_the_serial(tmp_path, monkeypatch):
+57 -1
View File
@@ -28,7 +28,7 @@ NODE = shutil.which("node")
pytestmark = pytest.mark.skipif(NODE is None, reason="node is not installed; the page-logic tests need it")
EXPORTS = ["seriesFromSerial", "unitQuery", "deviceUrl", "confirmedSeries", "controlsFor", "eventView", "settingsRows", "perIndexLive", "escapeHtml",
"changeSummary", "downloadSummary"]
"changeSummary", "downloadSummary", "firmwareLabel", "deviceErrorText", "changeErrorText", "serialPanes"]
def _block() -> str:
@@ -234,3 +234,59 @@ def test_the_per_index_routes_follow_the_list_not_the_keyboard():
def test_escape_html_makes_a_unit_string_inert():
r = run(["escapeHtml", ['Bench <b id="x">&\'']], ["escapeHtml", [None]], ["escapeHtml", [42]])
assert r == ["Bench &lt;b id=&quot;x&quot;&gt;&amp;&#39;", "", "42"]
# ── Batch 2 (1c bench polish, 2026-11-02) ─────────────────────────────────────
def test_firmware_label_says_which_line_a_micromate_runs():
# #12: a Micromate's version string is in 0x01, undecoded; its firmware line is known.
r = run(["firmwareLabel", [{"firmware": "S338.17"}]], ["firmwareLabel", [{"firmware_version": "S338.17"}]],
["firmwareLabel", [{"firmware": None, "detail": {"firmware_line": "thor"}}]],
["firmwareLabel", [{"firmware": None, "detail": {"firmware_line": "blastware"}}]],
["firmwareLabel", [{"firmware": None, "detail": {"firmware_line": "unknown"}}]],
["firmwareLabel", [{}]], ["firmwareLabel", [None]])
assert r == ["S338.17", "S338.17", "Thor line (version not read)", "Blastware line (version not read)",
"—", "—", "—"]
HINT = ("the connection opened, so the modem is reachable — another program (THOR or Blastware) may be "
"holding this unit's line, or the unit is busy (e.g. its sensor check)")
def test_a_504_says_another_program_may_hold_the_line():
# #16: measured 2026-10-29 -- while THOR polls a Micromate, SFM's connection is
# accepted and gets 0 bytes, a 504. The hint is not added once a change was sent.
silent = {"detail": "the unit did not answer: no reply"}
sent = {"detail": "start monitoring was sent and acknowledged, but reading the state back failed: x "
"-- audit record c7", "sent": "acknowledged", "audit_id": "c7"}
r = run(["deviceErrorText", [504, silent, S4, "HTTP 504"]], ["deviceErrorText", [504, sent, S4, "HTTP 504"]],
["deviceErrorText", [503, {"detail": "could not connect: refused"}, S4, "HTTP 503"]],
["deviceErrorText", [504, silent, {"serial": "UM20147", "host": "", "tcpPort": 9034}, "HTTP 504"]],
["deviceErrorText", [502, {}, S4, "HTTP 502"]])
assert r == [f"the unit did not answer: no reply — {HINT}", sent["detail"], "could not connect: refused",
"the unit did not answer: no reply", "HTTP 502"]
def test_a_change_that_was_sent_is_not_called_failed():
# #10: a ChangeUnconfirmed body carries `sent`; anything else is a real failure.
sent = {"detail": "start monitoring was sent and acknowledged, but reading the state back failed: x "
"-- audit record c7", "sent": "acknowledged", "audit_id": "c7"}
r = run(["changeErrorText", ["Start", 504, sent, S3, "HTTP 504"]],
["changeErrorText", ["Stop", 503, {**sent, "sent": "unknown"}, S3, "HTTP 503"]],
["changeErrorText", ["Start", 504, {"detail": "the unit did not answer: no reply"}, S3, "HTTP 504"]],
["changeErrorText", ["Stop", 409, {"detail": "not BE9441: BE12599 answered"}, S3, "HTTP 409"]])
assert r[0] == f"Start monitoring not confirmed: {sent['detail']}"
assert r[1] == f"Stop monitoring not confirmed: {sent['detail']}"
assert r[2] == f"Start monitoring failed: the unit did not answer: no reply — {HINT}"
assert r[3] == "Stop monitoring failed: not BE9441: BE12599 answered"
assert not any(x.startswith(("Start monitoring failed", "Stop monitoring failed")) for x in r[:2])
def test_serial_mode_hides_the_legacy_forms():
# #6 / #12: by serial, settings are read-only until phase 5 -- no empty edit
# form, no empty legacy tables; the settings box shows from the start.
r = run(["serialPanes", [True, False]], ["serialPanes", [True, True]], ["serialPanes", [False, False]])
assert r == [{"configForm": False, "settingsBox": True, "settingsPlaceholder": True, "legacyDeviceTables": False},
{"configForm": False, "settingsBox": True, "settingsPlaceholder": False, "legacyDeviceTables": False},
{"configForm": True, "settingsBox": False, "settingsPlaceholder": False, "legacyDeviceTables": True}]