docs(claude): refresh "Where things stand" -- it claimed there was no live client
Stale since 2026-09-26, and wrong in two ways that matter to anyone picking the project up: - "micromate/ still has no live client -- it is codec-only." There has been a full client since 2026-10-02: framing/protocol/client + models, 119 tests, verified on hardware across both firmware lines and both transports. - "the inbound call-home session is the only protocol unknown left." It was captured end to end on 2026-10-14. There are no protocol unknowns left. Replaced with the current state, and added the three things a reader most needs up front: that ACH has TWO paths decided by who holds the modem's single session (so silence from a probe is usually contention with THOR, not a fault); that 0xA2 ends a call-home on series IV and CONFIRMS ERASE on series III across a shared transport; and that monitor-while-calling-home blocks erase while THOR calls the session a success, which makes the server-side high-water mark load-bearing. Also named the real remaining gap honestly: config decoding, not protocol. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
This commit is contained in:
1 parent
7645c91ae2
commit
9c8eb5c5b8
1 file changed
+31
-6
@@ -10,7 +10,7 @@ pair — lives in `../terra-view/docs/tmi-stack.md`, which is also loaded as
|
||||
|
||||
---
|
||||
|
||||
## Where things stand (updated 2026-09-26)
|
||||
## Where things stand (updated 2026-10-14)
|
||||
|
||||
Read this first when picking the project back up.
|
||||
|
||||
@@ -22,14 +22,39 @@ Read this first when picking the project back up.
|
||||
firmware) or `0x03` (Thor firmware) rather than `0x10`, and the data length
|
||||
is a **uint16 BE at `payload[8:10]`** (as a byte it under-reads `SUB 0x1A`
|
||||
by 47x). Read path, event chain, setups, scheduler, monitoring control and
|
||||
per-event delete are all mapped; **the inbound call-home session is the only
|
||||
protocol unknown left.**
|
||||
per-event delete are all mapped — **and as of 2026-10-14 so is the inbound
|
||||
call-home session.** There are no protocol unknowns left.
|
||||
⚠ **No command has ever been originated against a unit by this project.**
|
||||
Every write was performed by THOR while we recorded. That line is worth
|
||||
keeping.
|
||||
⚠ `micromate/` still has **no live client** — it is codec-only. The
|
||||
`minimateplus/` stack (transport/framing/protocol/client) has no Series-4
|
||||
counterpart yet. `minimateplus.transport` is protocol-agnostic and reusable.
|
||||
- **✅ `micromate/` HAS a live client (2026-10-02).** `framing.py`,
|
||||
`protocol.py`, `client.py` + models, **119 tests**, mirroring the
|
||||
`minimateplus/` stack and reusing its `transport.py` unchanged. Connect over
|
||||
TCP or serial, identify a unit, read state/clock/battery/memory, list setups,
|
||||
walk the event chain and download + decode events. **Read-only** — every
|
||||
write remains mapped-but-unimplemented, deliberately.
|
||||
Verified on hardware across **both firmware lines** (UM12947 `11.0CB`,
|
||||
UM20147 `11.0BD`) and **both transports** (USB CDC-ACM and an RX55 over
|
||||
cellular), byte-identical.
|
||||
⚠ **The gap is config decoding**, not the protocol: `0x1A` (2,103 B) has
|
||||
about a dozen fields read; `0x2C`, `0x2E`, `0x08`, `0x01` are fetched and
|
||||
undecoded. Finishing it needs a bench session varying one setting at a time,
|
||||
as was done for Series III — not desk work.
|
||||
- **🔑 ACH / call-home, captured end to end (2026-10-14).** A Micromate signals
|
||||
`RADIO RING`; **two paths exist and timing decides which**: if anything
|
||||
already holds the modem's single TCP session the ring rides that connection,
|
||||
otherwise the modem dials out to a listener. THOR's `UnitWatchDogTimer`
|
||||
reconnects continuously, so THOR usually holds that slot — which is why
|
||||
probes and relays see silence. That is contention, not a fault.
|
||||
⚠⚠ **`SUB 0xA2` ends a call-home on Series IV and is CONFIRM ERASE on
|
||||
Series III** — same opcode, same `0x5D` response, opposite consequence.
|
||||
`minimateplus` and `micromate` share a transport; dispatch on series before
|
||||
that byte reaches a wire.
|
||||
⚠ **"Monitor While Calling Home" silently blocks erase**, and THOR reports
|
||||
the session successful anyway. A receiver therefore **cannot rely on erase to
|
||||
manage storage** — the server-side high-water mark is load-bearing.
|
||||
⚠ `bridges/mm_ach_server.py` implements the listener path only; it needs to
|
||||
also hold outbound connections and watch for the ring.
|
||||
- **Bench tooling for device diagnosis (2026-09-25).** `bridges/mm_probe.py`
|
||||
distinguishes the four faults THOR reports identically as "disconnected"
|
||||
(refused / connect timeout / **connected but no reply** / replied) and names
|
||||
|
||||
Reference in new issue
Block a user