feat(bridges): mm_dry_run -- a write's planned frames from a live unit's reads; bench-checked on UM20147

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-22 17:29:00 -04:00
1 parent cbda4b80df
commit 9ecf6e6a0c
3 files changed
+107

No files matched your search

+8
View File
@@ -27,6 +27,14 @@ Read this first when picking the project back up.
⚠ **No command has ever been originated against a unit by this project.**
Every write was performed by THOR while we recorded. That line is worth
keeping.
**Series-4 write path, phase 2 is done (2026-10-22):** the write encoder, a
send-side opcode gate and write *plans* for start/stop, call-home enable and
the setup rewrite, reproduced byte for byte against THOR's captured frames.
`bridges/mm_dry_run.py` prints a write's planned frames from a live unit's
reads (run on UM20147: sizes equal UM12947's). `MicromateProtocol._send`
refuses every write opcode unless explicitly allowed, and `0xA2` always, so
"no command has ever been originated against a unit" is still true and is now
enforced in code.
- **✅ `micromate/` HAS a live client (2026-10-02).** `framing.py`,
`protocol.py`, `client.py` + models, **119 tests**, mirroring the
`minimateplus/` stack and reusing its `transport.py` unchanged. Connect over
+84
View File
@@ -0,0 +1,84 @@
#!/usr/bin/env python3
"""Dry run a Micromate write against a live unit: do the reads, print the plan.
Sends READS only. The write frames are built from the unit's own blocks and
printed for review -- step 1 of the bench protocol for every first live write
(parity spec, Testing). The protocol's opcode gate refuses every write SUB on
this connection, so nothing else can go out even by mistake.
sg dialout -c ".venv/bin/python bridges/mm_dry_run.py /dev/ttyACM0 call-home-off"
.venv/bin/python bridges/mm_dry_run.py --host 10.0.0.5 --tcp-port 9034 setup-rewrite
The JSON carries a `reads` block (length of each block read, and for
setup-rewrite the blocks themselves in hex) so the plan can be checked against
what the unit actually said.
"""
from __future__ import annotations
import argparse
import json
import sys
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from micromate.client import CONTENT, MicromateClient # noqa: E402
from micromate.writes import ( # noqa: E402
plan_call_home_enabled, plan_setup_push, plan_start_monitoring, plan_stop_monitoring,
)
from minimateplus.transport import SerialTransport, TcpTransport # noqa: E402
ACTIONS = ("start", "stop", "call-home-on", "call-home-off", "setup-rewrite")
def _content(data: bytes) -> bytes:
"""The protocol's read_* methods return the response data with its 11-byte prefix."""
return bytes(data)[CONTENT:]
def main() -> int:
ap = argparse.ArgumentParser(description=__doc__.splitlines()[0])
ap.add_argument("port", nargs="?", help="serial port, e.g. /dev/ttyACM0")
ap.add_argument("action", choices=ACTIONS)
ap.add_argument("--host")
ap.add_argument("--tcp-port", type=int, default=9034)
ap.add_argument("--baud", type=int, default=115200)
a = ap.parse_args()
if not (a.port or a.host):
ap.error("give a serial port or --host")
transport = TcpTransport(a.host, port=a.tcp_port) if a.host else SerialTransport(a.port, a.baud)
mm = MicromateClient(transport) # no allowed_writes: the gate refuses every write
mm.open()
try:
info = mm.connect()
p = mm.protocol
reads = {}
if a.action == "start":
plan = plan_start_monitoring()
elif a.action == "stop":
plan = plan_stop_monitoring()
elif a.action.startswith("call-home"):
ch = _content(p.read_call_home_config())
reads["0x2C"] = {"len": len(ch)}
plan = plan_call_home_enabled(ch, a.action == "call-home-on")
else:
name = mm.get_active_setup()
prefs = _content(p.read_event_index())
trig = _content(p.read_trigger_config())
setup = _content(p.read_compliance_config())
reads = {"active_setup": name,
"0x08": {"len": len(prefs), "hex": prefs.hex()},
"0x2E": {"len": len(trig), "hex": trig.hex()},
"0x1A": {"len": len(setup), "hex": setup.hex()}}
plan = plan_setup_push(prefs, trig, setup, name)
out = plan.describe()
out["unit"] = {"serial": info.serial, "firmware_line": info.firmware_line}
out["reads"] = reads
print(json.dumps(out, indent=1))
finally:
mm.close()
return 0
if __name__ == "__main__":
sys.exit(main())
+15
View File
@@ -1782,6 +1782,21 @@ Do **not** retune `_GEO_LSB_IPS` — this is corroboration, not a correction.
- **Scheduler / call-home writes.** `callhome.MMB` is a file too, so it may go
through the same `0xDA` + block-write shape with a different target name.
### Write-plan dry run on a second unit and firmware line (2026-10-22)
2026-10-22 — UM20147 (11.0BD) block sizes equal UM12947's (11.0CB): `0x1A`
content 2092 B, `0x08` 90 B, `0x2E` 28 B, `0x2C` 126 B (all CRCs good where a
CRC applies). Its dry-run plans (`bridges/mm_dry_run.py`) have the same SUB
order, offsets and data lengths as THOR's frames from UM12947: `0x96` / `0x97`
(offset `0xFFFF`, 0 B); `0x7E` @ `0x007E` 126 B + `0x7F`; `0xDA` @ `0x0100` 256 B,
`0x68` @ `0x005A` 88 B, `0x73`, `0x82` @ `0x001C` 28 B, `0x83`, `0x71` @ `0x082C`
2090 B, `0x72`. So THOR's write offsets apply to both firmware lines **as far
as size goes** (measured, one unit each; **nothing sent** -- reads only, the
opcode gate refused every write SUB). Not shown: that 11.0BD *accepts* these
frames. The call-home on/off plans differ in exactly one data byte (`[5]`);
the setup-rewrite `0x71` data equals the unit's `0x1A` content `[3:2090]` behind
three zero bytes.
### ✅ `0xDA` CREATES setup files (confirmed on the device, 2026-09-24)
`TEST1.mmb` did not exist on the unit before the push. Afterwards it is