feat(bridges): mm_dry_run -- a write's planned frames from a live unit's reads; bench-checked on UM20147

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-22 17:29:00 -04:00
1 parent cbda4b80df
commit 9ecf6e6a0c
3 files changed
+107

No files matched your search

+15
View File
@@ -1782,6 +1782,21 @@ Do **not** retune `_GEO_LSB_IPS` — this is corroboration, not a correction.
- **Scheduler / call-home writes.** `callhome.MMB` is a file too, so it may go
through the same `0xDA` + block-write shape with a different target name.
### Write-plan dry run on a second unit and firmware line (2026-10-22)
2026-10-22 — UM20147 (11.0BD) block sizes equal UM12947's (11.0CB): `0x1A`
content 2092 B, `0x08` 90 B, `0x2E` 28 B, `0x2C` 126 B (all CRCs good where a
CRC applies). Its dry-run plans (`bridges/mm_dry_run.py`) have the same SUB
order, offsets and data lengths as THOR's frames from UM12947: `0x96` / `0x97`
(offset `0xFFFF`, 0 B); `0x7E` @ `0x007E` 126 B + `0x7F`; `0xDA` @ `0x0100` 256 B,
`0x68` @ `0x005A` 88 B, `0x73`, `0x82` @ `0x001C` 28 B, `0x83`, `0x71` @ `0x082C`
2090 B, `0x72`. So THOR's write offsets apply to both firmware lines **as far
as size goes** (measured, one unit each; **nothing sent** -- reads only, the
opcode gate refused every write SUB). Not shown: that 11.0BD *accepts* these
frames. The call-home on/off plans differ in exactly one data byte (`[5]`);
the setup-rewrite `0x71` data equals the unit's `0x1A` content `[3:2090]` behind
three zero bytes.
### ✅ `0xDA` CREATES setup files (confirmed on the device, 2026-09-24)