feat(webapp): config and call-home writes wait for phases 4-5; Diagnostics only for a confirmed Series-3 unit

- Config, with a serial: Read shows the unit's shared UnitSettings (setup,
  record mode, sample rate, record time, histogram interval, geo trigger,
  notes; — for null) in place of the write form.  settingsRows() is in the
  device-routing block, Node-tested; the rows are rendered as text, since
  setup names and notes come from the unit.
- Write stays off for both series (and without a serial), tooltip
  "Coming in phase 5 (#46)"; Call Home write likewise, "Coming in phase 4".
- Call Home read follows controlsFor().callHomeRead; for a confirmed Series 4
  the tab says "Not yet available for Series 4".
- Diagnostics: every button follows controlsFor().diagnostics (Task 3), and a
  refresh for anything but a confirmed Series-3 unit sends nothing and says
  why.  Its requests carry the typed serial, so the server guard checks it.
- Without a serial the legacy reads are unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-29 11:59:11 -04:00
1 parent 3f249e2322
commit a709d2388d
2 files changed
+85 -3

No files matched your search

+68 -2
View File
@@ -1008,7 +1008,12 @@
═══════════════════════════════════════════════════════════════════ -->
<div id="tab-config" class="tab-pane">
<div class="cfg-grid">
<div id="cfg-settings" style="display:none; margin-bottom:12px">
<div class="cfg-section-title">On the unit (read by serial)</div>
<div class="dev-table" id="cfg-settings-table"></div>
</div>
<div class="cfg-grid" id="cfg-form">
<!-- Recording parameters -->
<div class="cfg-section">
@@ -1233,6 +1238,7 @@
<button class="btn btn-success" id="ch-write-btn" onclick="writeCallHome()" disabled>Write to Device</button>
<button class="btn btn-ghost" onclick="clearCallHomeForm()">Clear Form</button>
<span id="ch-status"></span>
<span id="ch-series-note" style="color:var(--text-dim)"></span>
</div>
</div><!-- end #tab-call-home -->
@@ -1581,6 +1587,24 @@ function eventView(ev) {
return { label, title: ev.record_type || '', peaks };
}
// What the Config tab's serial-mode Read shows for a UnitSettings reply.
function settingsRows(st) {
const dash = v => (v == null || v === '' ? '—' : v);
const hi = st.histogram_interval_s;
const rows = [
['Setup Name', dash(st.setup_name)],
['Record Mode', dash(st.record_mode)],
['Sample Rate', st.sample_rate != null ? `${st.sample_rate} sps` : '—'],
['Record Time', st.record_time_s != null ? `${st.record_time_s.toFixed(2)} s` : '—'],
['Histogram Interval', hi == null ? '—' : hi < 60 ? `${hi} s` : `${hi / 60} min`],
['Geo Trigger', st.geo_trigger_ips != null ? `${st.geo_trigger_ips.toFixed(4)} in/s` : '—'],
];
const notes = Object.entries(st.notes || {});
if (!notes.length) rows.push(['Notes', '—']);
for (const [k, v] of notes) rows.push([`Note: ${k}`, dash(v)]);
return rows;
}
function downloadSummary(body) {
if (body.inserted === false) return `already stored — ${body.stored_filename}`;
return `stored ${body.stored_filename}, ${body.filesize} bytes, check: ${(body.detail || {}).check}`;
@@ -1686,7 +1710,11 @@ function applyControls() {
cw.disabled = !c.configWrite; cw.title = c.reasons.configWrite;
const hw = document.getElementById('ch-write-btn');
hw.disabled = !c.callHomeWrite; hw.title = c.reasons.callHomeWrite;
document.getElementById('ch-read-btn').disabled = !c.callHomeRead;
const chr = document.getElementById('ch-read-btn');
chr.disabled = !c.callHomeRead;
const s4 = series === 4 ? 'Not yet available for Series 4' : '';
chr.title = s4;
document.getElementById('ch-series-note').textContent = s4;
setMonitorButtons();
}
@@ -2069,6 +2097,19 @@ function populateDeviceTab() {
renderTable('project-table', projectRows);
}
function renderTextTable(id, rows) {
const el = document.getElementById(id);
el.innerHTML = '';
for (const [label, value] of rows) {
const row = document.createElement('div');
row.className = 'dev-table-row';
const l = document.createElement('div'); l.className = 'dtr-label'; l.textContent = label;
const v = document.createElement('div'); v.className = 'dtr-value'; v.textContent = value;
row.append(l, v);
el.appendChild(row);
}
}
function renderTable(id, rows) {
const el = document.getElementById(id);
el.innerHTML = '';
@@ -2120,6 +2161,10 @@ function diagResult(id, text, cls) {
async function refreshDiagnostics() {
if (!devHost()) return;
const st = document.getElementById('diag-status');
if (!controlsFor(currentUnit()).diagnostics) {
if (st) { st.textContent = 'Diagnostics are MiniMate tools: connect to a Series-3 unit first.'; st.className = ''; }
return;
}
if (st) { st.textContent = 'Reading…'; st.className = 'loading'; }
const [mon, store, idx] = await Promise.all([
@@ -2259,8 +2304,29 @@ function clearConfigForm() {
setCfgStatus('');
}
// Serial mode: the shared UnitSettings, read-only (writes wait for phase 5).
async function readSettingsBySerial() {
const btn = document.getElementById('cfg-read-btn');
btn.disabled = true;
setCfgStatus('Reading settings from the unit…');
try {
const st = await deviceFetch('settings');
renderTextTable('cfg-settings-table', settingsRows(st));
document.getElementById('cfg-settings').style.display = 'block';
document.getElementById('cfg-form').style.display = 'none';
setCfgStatus(`Settings read from ${st.serial}.`, 'ok');
} catch (e) {
setCfgStatus(`Read failed: ${e.message}`, 'error');
} finally {
btn.disabled = false;
}
}
async function readConfig() {
if (!devHost()) { setCfgStatus('Not connected.', 'error'); return; }
if (serialMode()) { await readSettingsBySerial(); return; }
document.getElementById('cfg-settings').style.display = 'none';
document.getElementById('cfg-form').style.display = '';
setCfgStatus('Reading config from device…');
document.getElementById('cfg-read-btn').disabled = true;
try {
+17 -1
View File
@@ -24,7 +24,7 @@ PAGE = Path(__file__).resolve().parent.parent / "sfm" / "sfm_webapp.html"
NODE = shutil.which("node")
pytestmark = pytest.mark.skipif(NODE is None, reason="node is not installed; the page-logic tests need it")
EXPORTS = ["seriesFromSerial", "unitQuery", "deviceUrl", "confirmedSeries", "controlsFor", "eventView",
EXPORTS = ["seriesFromSerial", "unitQuery", "deviceUrl", "confirmedSeries", "controlsFor", "eventView", "settingsRows",
"changeSummary", "downloadSummary"]
@@ -204,3 +204,19 @@ def test_event_view_reads_both_event_shapes():
assert b == {"label": "2026-10-26 16:06:37", "title": "Waveform",
"peaks": {"tran": 0.03, "vert": 0.095, "long": 0.02, "pvs": 0.1, "micPsi": 0.0001}}
assert c == {"label": "Event 5", "title": "", "peaks": None}
def test_settings_rows_show_unit_settings_with_a_dash_for_null():
full = {"serial": "UM20147", "series": 4, "setup_name": "TMI default", "record_mode": "Waveform",
"sample_rate": 1024, "record_time_s": 2.0, "histogram_interval_s": 900, "geo_trigger_ips": 0.02,
"notes": {"project": "Bench", "client": ""}}
empty = {"serial": "BE9441", "series": 3, "setup_name": None, "record_mode": None, "sample_rate": None,
"record_time_s": None, "histogram_interval_s": None, "geo_trigger_ips": None, "notes": {}}
a, b, c = run(["settingsRows", [full]], ["settingsRows", [empty]],
["settingsRows", [{**empty, "histogram_interval_s": 15}]])
assert a == [["Setup Name", "TMI default"], ["Record Mode", "Waveform"], ["Sample Rate", "1024 sps"],
["Record Time", "2.00 s"], ["Histogram Interval", "15 min"], ["Geo Trigger", "0.0200 in/s"],
["Note: project", "Bench"], ["Note: client", "—"]]
assert b == [["Setup Name", "—"], ["Record Mode", "—"], ["Sample Rate", "—"], ["Record Time", "—"],
["Histogram Interval", "—"], ["Geo Trigger", "—"], ["Notes", "—"]]
assert c[4] == ["Histogram Interval", "15 s"]