docs: the record chain to the footer and the sensor check (reference D.6.13)
- Reference D.6.13 (new): the tail of an event file is one record chain ending exactly at the file's end (70,041 / 70,041 DL2 files); the sensor-check header layout and what Blastware prints from it. - D.3.3: the footer is the chain's last record (length 00 1a, id 0e). - D.6.12: 'before and after' retracted in place -- one record per channel. - D.6.11, CLAUDE.md: 71 of 88 report fields match on every DL2 event (run 20261106-125854, 0 regressions; 59 before group E). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
This commit is contained in:
1 parent
f222ea9e80
commit
a80ea759e4
2 files changed
+74
-11
No files matched your search
@@ -45,12 +45,12 @@ Read this first when picking the project back up.
|
||||
- **Byte layouts** of every field read from the file:
|
||||
`docs/instantel_protocol_reference.md` Appendix **D.6**.
|
||||
|
||||
**Where the decoder stands on `dev`** (2026-11-05, run `20261105-140021`):
|
||||
**59 of 88 fields match on every event**, up from about 6 before v0.33.0 and
|
||||
47 before group D.
|
||||
**Where the decoder stands on `dev`** (2026-11-06, run `20261106-125854`):
|
||||
**71 of 88 fields match on every event**, up from about 6 before v0.33.0,
|
||||
47 before group D and 59 after it.
|
||||
- Groups A, B, C and D part 1 shipped in v0.34.0 (#50, #51).
|
||||
- D part 2 (the unit's own summary) is on `dev` and owes the next release
|
||||
a backfill.
|
||||
- D part 2 (the unit's own summary) and E (the sensor check) are on `dev`
|
||||
and owe the next release a backfill.
|
||||
- 🔑 **Events are keyed unit + time + type:** `UNIQUE(serial, timestamp,
|
||||
record_type)` (#51, Migration 3 in `sfm/database.py`, `dev`).
|
||||
- A waveform and its histogram may share a second: 209 times in prod's
|
||||
@@ -77,6 +77,14 @@ Read this first when picking the project back up.
|
||||
(fitted g 386.2238): 6,522–6,523 / 6,524. The unit stores its own
|
||||
too, which Blastware ignores. The misses are O117I1NK.R70W, whose
|
||||
samples wrap at the trigger, and S353I5PZ.EP0W Vert (open).
|
||||
- group E (D.6.13): sensor check frequency, ratio, mic amplitude and
|
||||
result, every record type. Also the unit's own, in each sensor-check
|
||||
record's header. "Check" is the unit's status code, not a limit SFM can
|
||||
recompute.
|
||||
- 🔑 **The tail of every event file is one record chain** (D.6.13):
|
||||
event record → unit summary → sensor checks → footer, each
|
||||
`[length][id][payload]`. It ends exactly at the file's end on all 70,041
|
||||
DL2 files, and SFM reads none of it otherwise.
|
||||
- 🔑 **"Units" means three different things — keep them apart** (reference
|
||||
D.6.6):
|
||||
- **Recorded data:** the mic samples and interval peaks in the file, as
|
||||
@@ -114,8 +122,8 @@ Read this first when picking the project back up.
|
||||
- ~~**D. Blastware's waveform calculations**~~ ✅ done. ZC frequency,
|
||||
displacement and time of peak are the unit's own (D.6.12); acceleration
|
||||
is Blastware's.
|
||||
- **E. Sensor check results.** Probably records `0x3c` / `0x3d`, which
|
||||
follow the unit's summary (inferred, D.6.12).
|
||||
- ~~**E. Sensor check results**~~ ✅ done (D.6.13). Plus the traces of a
|
||||
unit without a mic, which the trace decoder had been dropping.
|
||||
- **F. Monitor log:** probably not in the event file at all. Lead, not
|
||||
measured: O117I1NK's report prints its log as the event record's
|
||||
start – stop.
|
||||
|
||||
@@ -11,6 +11,7 @@
|
||||
|
||||
| Date | Section | Change |
|
||||
|---|---|---|
|
||||
| 2026-11-06 | Appendix D.6.13 (NEW), D.3.3, D.6.11, D.6.12 | ✅ **The record chain to the footer, and the sensor check.** Walked from the event record, the chain (event `0x05` → unit's summary `0x32`–`0x35` → sensor checks `0x3c`–`0x3f` → footer `0x0e`) ends exactly at the file's end on all 70,041 DL2 files. The footer is its last record: `00 1a` is its length, `0e` its id. **Each sensor-check record's header holds the unit's results:** channel type `[2]`, status `[4]` (0 = passed), frequency × 10 `[5:7]`, ratio × 10 `[7:9]` and amplitude mV `[9:11]`. Blastware prints them as they are: 209,943 / 209,943 geophone frequencies and ratios, 69,975 / 69,975 mic frequencies and amplitudes. The result is Passed / Check / Disabled by status and type. The status is the unit's own verdict, its bits not decoded. D.6.12's "`0x3c` / `0x3d`, before and after" retracted in place: one record per channel. **71 of 88 report fields now match on every DL2 event.** |
|
||||
| 2026-11-05 | Appendix D.6.12 (NEW), D.6.11, §7.8.9 | ✅ **The unit's own event summary, in every event file.** The embedded event record is the first of a `[length][id][payload]` chain. It holds the vector-sum peak's sample (6,492 / 6,493). Then one 22-byte record per channel, ids `0x32` Tran … `0x35` MicL: min, max, peak sample, **half-period** and a **displacement integral**. Blastware prints them as they are. **ZC frequency** = (rate / 2) / half-period, with the interval rule's words: 25,966 / 25,966 waveform and 253,958 / 253,958 histogram channel values. **Peak displacement** = half the integral: 19,479 / 19,479. Recomputing from the samples had reached 46% and 84%: the unit works at full resolution. **Times of peak** follow the unit's peak sample. That differs from the samples only on **O117I1NK.R70W**, whose stored samples wrap at the trigger by 65,536 counts (Blastware's own table has the same values). Peak acceleration is Blastware's own computation from the stored samples (group D part 1, documented here too). The unit stores its own largest step at `[15:21]` (inferred), which Blastware does not print. §7.8.9's "constant, meaning ❓" bytes amended in place. 59 of 88 report fields now match on every DL2 event (47 before group D). |
|
||||
| 2026-11-04 | SUB 1A / 09 reads, SUB 68–74 settings write, the keypad | **SFM's settings write, benched on BE9441 (Brian at the unit; ~12 writes, each with his go).** **Every write** -- trigger 0.04 ↔ 0.05, a note, several fields at once (Project, job number + its report flag, trigger), the alarm 1.0 ↔ 1.5, and a full restore -- was acknowledged on all nine steps (`97 8C 8E×5 8D 7D 7C 96 8B 8D`), read back as sent, and **confirmed on the unit's own screen**; the unit ended byte for byte as found. Moved bytes were exactly the field's: trigger f32 at each geophone channel +30 (`+31..+33` moved), **alarm f32 at channel +38** (`+39` moved; the first Series-3 alarm write), job number `[40:42]`, its report bit `[39]` `0x02`, a note's value window. **`[26:28]`** went `01 7f` → `00 00` on SFM's first write (Blastware's value) and the unit **set `01 7f` again during the next monitoring session**. The **two bytes after the block** went out as `00 00` (Blastware sends a per-unit constant) and were taken. **🔑 Escaped-checksum artifact:** when a reply's checksum byte is itself escaped (02 / 03 / 04, ~1 frame in 85), `S3FrameParser` keeps the escape's `0x10` and strips only the byte after it, so the frame's data gains one trailing `0x10`. It hit the first live 1A read (frame B 1,026 bytes after the header); the 12 recorded reads never had. SFM's settings read and waveform read now take exactly the length they asked for. **🔑 The keypad menu wins:** a write sent while the setup menu was open was acknowledged and read back, then **lost when the operator pressed Cancel or Save** -- the menu writes its own copy of the **whole** block back (both times the block returned byte for byte to its state when the menu was opened). A keypad Cancel with nothing pending leaves the block unchanged. **While monitoring**, the 1A read returns the device-info block (SFM refuses, nothing sent), and the opening poll was answered only intermittently (2 of 3 attempts timed out). Code: `minimateplus.protocol.read_compliance_content` / `read_waveform_data_raw`, `micromate.setup_fields`; notes `~/bench-logs/2026-11-04-sfm-settings/`. |
|
||||
| 2026-11-03 (5) | SUB 1A / 71 / 69 (settings read and write) | **The settings block, read and written as content (measured, BE9441's 10-26 recording and BE11529's 2026-04-20 captures).** **Read:** unescape each 1A data frame and take `data[11:]`; every frame but the last starts with one `00` that is not content; dropped, the frames join into **2,090 bytes headed by N = 2090: Series IV's `0x1A` content layout** (12 / 12 reads, Blastware's 4 × 512 + 42 and SFM's 1024 + 1024 + 42). The old "stable anchor" `be 80 00 00 00 00` is content `[12:18]` (pre-trigger −0.25 + stop mode Fixed). **Round trip:** the read after each of Blastware's two 10-26 writes equals the image it had just written, all 2,090 bytes (2 / 2). While monitoring, the read returns the device-info block (`0e 'BE9441' …`, 5 / 5). **`[26:28]`:** Blastware writes `00 00` on all 11 writes; the unit reads `01 7f` after a monitoring session (BE9441 10-26, BE11529 4-20 15:19) and sets it by itself; meaning unknown. **The two bytes after the block** (`[2090:2092]` of the 0x71 image) are Blastware's own per-unit constant -- `7c ea` on all nine of BE11529's writes, `0c e9` on both of BE9441's -- not the block's CRC-16/AUG, and in no reply of BE9441's three-hour session; SFM sends `00 00`. **`0x09` `[200:202]`:** Blastware echoed the unit's `8c 76` on all nine April writes; on 10-26 it read `17 17` and wrote `78 76` (read back so); meaning unknown. **Blastware re-renders the mic trigger level:** on BE11529's first write (4-20 15:19) the unit read 0.005 and 0.01 psi in its two `MicL` channel blocks (3 and 7; Series 3 carries 8 channel blocks of 48 bytes from `[1708]`, the second four prefixed `0x32`) and Blastware wrote 0.004983 and 0.010058 -- the same levels to its 0.1 dB; every other write left them alone. **Every one of the 11 Blastware writes reproduces** from the block before it with only the fields Blastware changed (plus that re-render and, on 10-26, the mic bit of `[25]`). Code: `minimateplus.protocol.assemble_compliance_content`, `read_compliance_content`, `micromate.setup_fields`; tests `tests/test_s3_settings_read.py`, `tests/test_setup_fields.py`. |
|
||||
@@ -3466,6 +3467,10 @@ The body is reconstructed from the raw A5 bulk waveform stream frames by strippi
|
||||
The footer terminates the N00 file. Its bytes come directly from the terminator A5 frame's inner content — do NOT reconstruct from event metadata.
|
||||
|
||||
✅ **It is the file's last 26 bytes** (2026-11-03): `0e 08` and two valid times end every one of 70,041 DL2 files.
|
||||
|
||||
> 🔑 **2026-11-06 (measured):** it is the last record of the chain that starts with the event
|
||||
> record (D.6.13). The two bytes before it, `00 1a`, are its length (26), and `0e` is its id.
|
||||
> The chain lands exactly on it in all 70,041 DL2 files.
|
||||
- ⚠ **Do not search for the first `0e 08` + plausible year.** 14 DL2 files also hold an earlier record of that shape, about 1.1 KB before the end, carrying the stop time followed by zeros.
|
||||
- Taking it made a histogram start at its own stop (a day late on BE9558's daily histograms). It also cost a waveform its stop, and with it the trigger time.
|
||||
|
||||
@@ -3959,12 +3964,12 @@ All four channels match every DL2 histogram.
|
||||
|
||||
#### D.6.11 Not read from the file yet
|
||||
|
||||
*Updated 2026-11-05. 59 of 88 report fields now match on every DL2 event, up from 47
|
||||
before group D (run `20261105-140021`, 0 regressions).*
|
||||
*Updated 2026-11-06. 71 of 88 report fields now match on every DL2 event: 47 before group D,
|
||||
59 after it, 71 with the sensor check (run `20261106-125854`, 0 regressions).*
|
||||
- **Fields not read yet:**
|
||||
- extended notes
|
||||
- sensor check results (probably the records after the unit's summary, `0x3c` / `0x3d`;
|
||||
inferred, D.6.12)
|
||||
- ~~sensor check results~~ **read, 2026-11-06 (D.6.13)**: the unit's own, in the header of
|
||||
each sensor-check record
|
||||
- monitor log
|
||||
- ~~the values Blastware computes: ZC frequency, acceleration, displacement, time of peak~~
|
||||
**Read, 2026-11-04 → 05 (D.6.12).** Blastware prints the unit's own ZC frequency,
|
||||
@@ -4017,6 +4022,11 @@ channels. The 4 others are O117I1NK (below).
|
||||
**Then records `0x3c` (and on a histogram `0x3d`)**, length 202–212. Not read yet. Probably
|
||||
the sensor check, before and after (inferred, not measured).
|
||||
|
||||
> ⚠ **RETRACTED 2026-11-06 (measured):** "before and after". They are the sensor check, but
|
||||
> one record per channel: `0x3c` Tran, `0x3d` Vert, `0x3e` Long, `0x3f` MicL, on waveforms and
|
||||
> histograms alike. My first walk stopped at the first id it did not know. The chain runs on
|
||||
> to the footer: D.6.13.
|
||||
|
||||
**What Blastware prints from them.** It prints the unit's values; it does not recompute them:
|
||||
|
||||
| Field | Rule | DL2 |
|
||||
@@ -4047,6 +4057,51 @@ full resolution: a stored sample of ±16 counts hides anything from 1 to 31.
|
||||
from sample 4,096 to 4,097, which its own sample table shows. Not explained. Skipping every
|
||||
4,096-sample boundary fixes this file but breaks another.
|
||||
|
||||
#### D.6.13 The record chain to the footer, and the sensor check ✅ 2026-11-06
|
||||
|
||||
**The whole tail of an event file is one record chain.** Walked from the event record by its
|
||||
length prefixes, it ends exactly at the file's last byte on **all 70,041 DL2 files**, in two
|
||||
shapes:
|
||||
|
||||
| Files | Chain |
|
||||
|---|---|
|
||||
| 70,033 | `0x05` event record → `0x32`–`0x35` unit's summary (D.6.12) → `0x3c`–`0x3f` sensor checks → `0x0e` footer |
|
||||
| 8 | the same without `0x35` and `0x3f`: BE16352, which records no mic |
|
||||
|
||||
The **footer** (D.3.3, "the file's last 26 bytes") is the chain's last record: its length
|
||||
`00 1a` sits just before it, and its first byte, `0e`, is its id. SFM reads nothing in the
|
||||
chain unless the walk ends exactly at the end of the file.
|
||||
|
||||
**Each sensor-check record** (`0x3c` Tran, `0x3d` Vert, `0x3e` Long, `0x3f` MicL) holds the
|
||||
check the unit ran: a header with its results, then the trace Blastware draws in its "Sensor
|
||||
Check" strip (`minimateplus/sensor_check.py`, since 2026-09-15). Payload after the id:
|
||||
|
||||
| bytes | content |
|
||||
|---|---|
|
||||
| `[0:2]` | `00 00` |
|
||||
| `[2]` | channel type: `01` geophone, `02` mic, `00` the check disabled |
|
||||
| `[3]` | `00` |
|
||||
| `[4]` | **status**: `00` passed; 1–15 otherwise |
|
||||
| `[5:7]` | **frequency × 10**, uint16 BE (Hz) |
|
||||
| `[7:9]` | **ratio × 10**, uint16 BE (geophones; the mic's reads 10) |
|
||||
| `[9:11]` | **amplitude, mV**, uint16 BE (the mic's; geophones carry a value too, ~260–700, not printed) |
|
||||
| `[11:19]` | not identified ❓ |
|
||||
| `[19:]` | the trace (`sensor_check.py`'s `_HEADER_LEN` = 20 counts the id byte) |
|
||||
|
||||
**What Blastware prints** (`TestFreq`, `TestRatio`, `TestAmplitude`, `TestResults`):
|
||||
|
||||
| Field | Rule | DL2 |
|
||||
|---|---|---|
|
||||
| geophone test frequency and ratio | as stored, ÷ 10 | 209,943 / 209,943 each |
|
||||
| mic test frequency and amplitude | as stored (frequency ÷ 10) | 69,975 / 69,975 each |
|
||||
| result | `Passed` at status 0, `Check` at any other, `Disabled` at channel type 0 (and nothing else printed) | every channel |
|
||||
|
||||
**The status code is the unit's verdict, not a limit SFM can recompute.** Geophones that pass
|
||||
span 6.7–9.4 Hz and ratio 1.9–6.0, yet K559L6N1's Tran reads `Check` at 8.1 Hz and 3.3. Each
|
||||
of the four bits occurs across the whole range of frequency, ratio and amplitude, so their
|
||||
meanings are not decoded. Every mic `Check` in DL2 (691) is status 13 with frequency 0 and
|
||||
amplitude 0: a mic that did not respond (inferred).
|
||||
|
||||
---
|
||||
|
||||
*All findings reverse-engineered from live RS-232 bridge captures.*
|
||||
|
||||
Reference in new issue