feat(sfm): POST /device/settings/change; retire the legacy config write
DeviceAccess.change_settings refuses before any I/O a request with no changes, a live change without its preview's revision, or no audit log, then dispatches the series' change (never retried). The route returns the preview (fields old -> new, warnings, blocked, revision) or the result (fields old/new/now), statuses as the other changes, and marks the cached by-host config dirty after a live change. /device/config and /device/config/project now answer 410 with a pointer. Deleted with them: MiniMateClient.apply_config / set_project_info and the raw-offset _encode_compliance_config (#46 found it wrong), the lab script poc_set_project.py and experiments.py's EXP6, both of which wrote a live unit through it. Git keeps them. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
66bb29b9d4
commit
e8eabee4a2
10 files changed
+316
-749
No files matched your search
-107
@@ -60,7 +60,6 @@ from minimateplus.framing import build_bw_frame, SESSION_RESET
|
||||
from minimateplus.client import (
|
||||
MiniMateClient,
|
||||
_decode_compliance_config_into,
|
||||
_encode_compliance_config,
|
||||
)
|
||||
from minimateplus.models import DeviceInfo
|
||||
|
||||
@@ -462,111 +461,6 @@ def exp_fewer_polls(host: str, port: int) -> tuple[str, str, dict]:
|
||||
t.disconnect()
|
||||
|
||||
|
||||
# ══════════════════════════════════════════════════════════════════════════════
|
||||
# EXP6 — Compliance-only write (71×3→72), skip event index + trigger + waveform
|
||||
# ══════════════════════════════════════════════════════════════════════════════
|
||||
#
|
||||
# Blastware's full write sequence: 68→73 | 71×3→72 | 82→83 | 69→74→72
|
||||
# We want to know: can we write ONLY the compliance block (71×3→72)?
|
||||
#
|
||||
# Test procedure:
|
||||
# 1. Read current compliance config (SUB 1A)
|
||||
# 2. Patch the "notes" field to a test marker
|
||||
# 3. Write ONLY 71×3→72 (skip 68, 73, 82, 83, 69, 74, final 72)
|
||||
# 4. Read back (SUB 1A) and verify the change was written
|
||||
# 5. Restore original value
|
||||
#
|
||||
# If PASS: we can push individual config fields without touching event index,
|
||||
# trigger config, or waveform data — huge simplification.
|
||||
# If FAIL: the device needs the full write sequence (may reject partial write).
|
||||
#
|
||||
# SAFETY: We restore original data in a finally block. If the restore write
|
||||
# fails, the device will have the test marker in "notes" — harmless but visible.
|
||||
|
||||
_EXP6_MARKER = "[exp6-test]"
|
||||
|
||||
def exp_compliance_only(host: str, port: int) -> tuple[str, str, dict]:
|
||||
"""Write compliance block alone (71×3→72), verify, and restore."""
|
||||
client, info = connect_client(host, port)
|
||||
original_raw: Optional[bytes] = None
|
||||
try:
|
||||
proto = client._proto
|
||||
if proto is None:
|
||||
return "FAIL", "Could not get protocol handle from client", {}
|
||||
|
||||
# 1. Read current compliance
|
||||
print(" Reading current compliance config (SUB 1A)…")
|
||||
original_raw = proto.read_compliance_config()
|
||||
print(f" Got {len(original_raw)} bytes of compliance config")
|
||||
|
||||
# Find current notes value for display
|
||||
info_obj = DeviceInfo()
|
||||
_decode_compliance_config_into(original_raw, info_obj)
|
||||
cc = info_obj.compliance_config
|
||||
orig_notes = cc.notes if cc else "(unknown)"
|
||||
print(f" Current notes field: {orig_notes!r}")
|
||||
|
||||
# 2. Build modified payload with test marker in notes
|
||||
test_notes = _EXP6_MARKER
|
||||
modified_raw = _encode_compliance_config(
|
||||
original_raw,
|
||||
notes=test_notes,
|
||||
)
|
||||
print(f" Encoded modified compliance payload ({len(modified_raw)} bytes)")
|
||||
print(f" Patching notes: {orig_notes!r} → {test_notes!r}")
|
||||
|
||||
# 3. Write ONLY the compliance block: 71×3 → 72
|
||||
print(" Writing compliance ONLY (71×3→72) — skipping 68/73/82/83/69/74…")
|
||||
proto.write_compliance_config_raw(modified_raw)
|
||||
print(" Write complete — device acked 71×3→72")
|
||||
|
||||
# 4. Read back and verify
|
||||
print(" Reading back compliance config to verify…")
|
||||
readback_raw = proto.read_compliance_config()
|
||||
readback_info = DeviceInfo()
|
||||
_decode_compliance_config_into(readback_raw, readback_info)
|
||||
rb_cc = readback_info.compliance_config
|
||||
readback_notes = rb_cc.notes if rb_cc else "(decode failed)"
|
||||
print(f" Read-back notes: {readback_notes!r}")
|
||||
|
||||
write_worked = (readback_notes == test_notes)
|
||||
print(f" Write verified: {write_worked}")
|
||||
|
||||
details = {
|
||||
"original_notes": orig_notes,
|
||||
"written_notes": test_notes,
|
||||
"readback_notes": readback_notes,
|
||||
"write_verified": write_worked,
|
||||
}
|
||||
|
||||
if write_worked:
|
||||
return "PASS", "Compliance-only write works! No event index or trigger writes needed.", details
|
||||
else:
|
||||
return "FAIL", f"Write was not reflected in read-back (got {readback_notes!r})", details
|
||||
|
||||
except ProtocolError as exc:
|
||||
return "FAIL", f"Protocol error: {exc}", {}
|
||||
|
||||
finally:
|
||||
# Restore original compliance data regardless of outcome
|
||||
if original_raw is not None:
|
||||
print(" Restoring original compliance config…")
|
||||
try:
|
||||
proto2 = client._proto
|
||||
if proto2:
|
||||
proto2.write_compliance_config_raw(
|
||||
_encode_compliance_config(original_raw) # no-op patch = verbatim
|
||||
)
|
||||
print(" Restore complete")
|
||||
else:
|
||||
print(" WARNING: protocol handle gone — could not restore")
|
||||
except Exception as exc_r:
|
||||
print(f" WARNING: restore failed: {exc_r}")
|
||||
client.close()
|
||||
|
||||
|
||||
# ══════════════════════════════════════════════════════════════════════════════
|
||||
# Registry + main
|
||||
# ══════════════════════════════════════════════════════════════════════════════
|
||||
|
||||
EXPERIMENTS = {
|
||||
@@ -575,7 +469,6 @@ EXPERIMENTS = {
|
||||
"no_5a": ("EXP3", exp_no_5a, "Event record (0C) without bulk waveform (5A)"),
|
||||
"skip_1e": ("EXP4", exp_skip_1e, "0A/0C with cached key — skip initial 1E"),
|
||||
"fewer_polls": ("EXP5", exp_fewer_polls, "1 POLL before 5A instead of Blastware's 3"),
|
||||
"compliance_only": ("EXP6", exp_compliance_only, "Compliance-only write (71×3→72), no other blocks"),
|
||||
}
|
||||
|
||||
|
||||
|
||||
+2
-370
@@ -70,15 +70,8 @@ S3_MONITORING_FLAGS = frozenset({0x10, 0x0B})
|
||||
# ⚠ RETRACTED 2026-10-27 (#46): a trigger block "hardcoded from 3-11-26 -- no
|
||||
# read exists, Blastware writes this fixed blob". Blastware reads it first (SUB
|
||||
# 0x2E), and its byte 5 differs by unit and session (01 / 03 / 04 on record), so
|
||||
# the copy changed that setting on any unit that differed. apply_config reads
|
||||
# the unit's own block (MiniMateProtocol.read_trigger_config).
|
||||
|
||||
# Compliance ASCII slot format (confirmed from 3-11-26 capture + label search):
|
||||
# Each label occupies a 64-byte slot.
|
||||
# Value starts at slot_start + 22, max 42 bytes, null-padded.
|
||||
_COMPLIANCE_SLOT_SIZE = 64
|
||||
_COMPLIANCE_VALUE_OFFSET = 22
|
||||
_COMPLIANCE_VALUE_MAX = _COMPLIANCE_SLOT_SIZE - _COMPLIANCE_VALUE_OFFSET # 42
|
||||
# the copy changed that setting on any unit that differed. A settings write sends
|
||||
# the unit's own block back (sfm.device_access.s3 change_settings, phase 5).
|
||||
|
||||
|
||||
# ── MiniMateClient ────────────────────────────────────────────────────────────
|
||||
@@ -997,120 +990,6 @@ class MiniMateClient:
|
||||
|
||||
log.info("push_config_raw: complete")
|
||||
|
||||
def apply_config(
|
||||
self,
|
||||
*,
|
||||
# Recording parameters
|
||||
recording_mode: Optional[int] = None,
|
||||
sample_rate: Optional[int] = None,
|
||||
record_time: Optional[float] = None,
|
||||
histogram_interval_sec: Optional[int] = None,
|
||||
# Threshold parameters (geo channels, in/s)
|
||||
trigger_level_geo: Optional[float] = None,
|
||||
alarm_level_geo: Optional[float] = None,
|
||||
geo_range: Optional[int] = None, # 0x00=Normal 10in/s, 0x01=Sensitive 1.25in/s
|
||||
# Project / operator strings
|
||||
project: Optional[str] = None,
|
||||
client_name: Optional[str] = None,
|
||||
operator: Optional[str] = None,
|
||||
seis_loc: Optional[str] = None,
|
||||
notes: Optional[str] = None,
|
||||
) -> None:
|
||||
"""
|
||||
Read the current device config, apply any supplied changes to the
|
||||
compliance block, and write the full config back to the device.
|
||||
|
||||
Only non-None arguments are modified; all other bytes are round-tripped
|
||||
verbatim from the device.
|
||||
|
||||
Configurable fields
|
||||
-------------------
|
||||
Recording parameters:
|
||||
recording_mode : int — 0x00=Single Shot, 0x01=Continuous, 0x03=Histogram, 0x04=Histogram+Continuous
|
||||
sample_rate : int — samples/sec; valid values: 1024, 2048, 4096
|
||||
record_time : float — record duration in seconds (e.g. 2.0, 3.0)
|
||||
|
||||
Trigger/alarm thresholds and range (geo channels):
|
||||
trigger_level_geo : float — trigger threshold in/s (e.g. 0.5)
|
||||
alarm_level_geo : float — alarm threshold in/s (e.g. 1.0)
|
||||
geo_range : int — 0x00=Normal 10.000 in/s, 0x01=Sensitive 1.250 in/s
|
||||
(written to Tran/Vert/Long channel blocks)
|
||||
|
||||
Project / operator strings (max 41 ASCII characters each):
|
||||
project : str
|
||||
client_name : str
|
||||
operator : str
|
||||
seis_loc : str — sensor location
|
||||
notes : str — extended notes
|
||||
|
||||
Write sequence (confirmed from 3-11-26 BW TX capture):
|
||||
68→73 | 71×3→72 | 82→83 | 69→74→72
|
||||
|
||||
Write payloads:
|
||||
event_index_data : 88 bytes — read live via SUB 08
|
||||
compliance_data : ~2128 bytes — read live via SUB 1A (~2126 bytes, varies ±1-2) + \\x00\\x00 footer
|
||||
trigger_data : 26 bytes — read live via SUB 2E (was hard-coded; #46)
|
||||
waveform_data : 204 bytes — read live via SUB 09
|
||||
|
||||
Raises:
|
||||
RuntimeError: if not connected.
|
||||
ProtocolError: if any read or write step fails.
|
||||
ValueError: if compliance buffer is shorter than the 2082-byte write minimum.
|
||||
"""
|
||||
proto = self._require_proto()
|
||||
|
||||
# 1. Read current payloads from the device
|
||||
log.info("apply_config: reading event index (SUB 08)")
|
||||
event_index_data = proto.read_event_index()
|
||||
|
||||
log.info("apply_config: reading compliance config (SUB 1A)")
|
||||
compliance_raw = proto.read_compliance_config() # ~2126 bytes (varies ±1-2 by DLE jitter)
|
||||
|
||||
log.info("apply_config: reading waveform data (SUB 09)")
|
||||
waveform_data = proto.read_waveform_data_raw() # 204 bytes
|
||||
|
||||
log.info("apply_config: reading trigger config (SUB 2E)")
|
||||
trigger_data = proto.read_trigger_config() # 26 bytes, this unit's own
|
||||
|
||||
# 2. Patch the compliance buffer and build the 2128-byte write payload
|
||||
compliance_data = _encode_compliance_config(
|
||||
compliance_raw,
|
||||
recording_mode=recording_mode,
|
||||
sample_rate=sample_rate,
|
||||
record_time=record_time,
|
||||
histogram_interval_sec=histogram_interval_sec,
|
||||
trigger_level_geo=trigger_level_geo,
|
||||
alarm_level_geo=alarm_level_geo,
|
||||
geo_range=geo_range,
|
||||
project=project,
|
||||
client_name=client_name,
|
||||
operator=operator,
|
||||
seis_loc=seis_loc,
|
||||
notes=notes,
|
||||
)
|
||||
log.info("apply_config: compliance payload ready (%d bytes)", len(compliance_data))
|
||||
|
||||
# 3. Push the full write sequence to the device
|
||||
self.push_config_raw(event_index_data, compliance_data, trigger_data, waveform_data)
|
||||
log.info("apply_config: complete")
|
||||
|
||||
def set_project_info(
|
||||
self,
|
||||
project: Optional[str] = None,
|
||||
client_name: Optional[str] = None,
|
||||
operator: Optional[str] = None,
|
||||
seis_loc: Optional[str] = None,
|
||||
notes: Optional[str] = None,
|
||||
) -> None:
|
||||
"""Backwards-compat shim — delegates to apply_config()."""
|
||||
self.apply_config(
|
||||
project=project,
|
||||
client_name=client_name,
|
||||
operator=operator,
|
||||
seis_loc=seis_loc,
|
||||
notes=notes,
|
||||
)
|
||||
|
||||
# ── Call home config ──────────────────────────────────────────────────────
|
||||
|
||||
def get_call_home_config(self) -> CallHomeConfig:
|
||||
@@ -2127,253 +2006,6 @@ def _extract_project_strings(data: bytes) -> Optional[ProjectInfo]:
|
||||
)
|
||||
|
||||
|
||||
def _encode_compliance_config(
|
||||
raw: bytes,
|
||||
*,
|
||||
recording_mode: Optional[int] = None,
|
||||
sample_rate: Optional[int] = None,
|
||||
record_time: Optional[float] = None,
|
||||
trigger_level_geo: Optional[float] = None,
|
||||
alarm_level_geo: Optional[float] = None,
|
||||
geo_range: Optional[int] = None, # 0x00=Normal 10in/s, 0x01=Sensitive 1.25in/s
|
||||
histogram_interval_sec: Optional[int] = None,
|
||||
project: Optional[str] = None,
|
||||
client_name: Optional[str] = None,
|
||||
operator: Optional[str] = None,
|
||||
seis_loc: Optional[str] = None,
|
||||
notes: Optional[str] = None,
|
||||
) -> bytes:
|
||||
"""
|
||||
Patch a live 2126-byte compliance buffer (read from the device) with any
|
||||
supplied field values and return the 2128-byte write payload.
|
||||
|
||||
Only non-None arguments are modified; everything else is round-tripped verbatim.
|
||||
|
||||
Numeric field locations (all anchor-relative or label-relative — immune to
|
||||
DLE-jitter shifts):
|
||||
|
||||
Anchor: b'\\xbe\\x80\\x00\\x00\\x00\\x00' (confirmed stable, both BE11529 and BE18189)
|
||||
⚠ 2026-10-29: these RAW offsets were measured at 1024 sps, where the escape
|
||||
before `04` sits between the mode and the anchor. The decoder now reads
|
||||
the four fields after unescaping (mode -7, rate -6, interval -4, record
|
||||
time +6), so at any other layout these patch the wrong bytes. Until the
|
||||
encoder is rewritten on unescaped bytes (#46), a payload whose four fields
|
||||
do not read back as asked raises ValueError -- see the end of this function.
|
||||
recording_mode → uint8 at anchor_pos - 8 (raw; right at 1024 sps only)
|
||||
Values: 0x00=Single Shot, 0x01=Continuous, 0x03=Histogram, 0x04=Histogram+Continuous
|
||||
NOTE: The byte at anchor_pos - 7 is always 0x10 (a DLE marker regenerated by
|
||||
device firmware in every E5 response). It must NOT be overwritten during
|
||||
write — doing so causes anchor drift (+1 per write cycle).
|
||||
CORRECTION 2026-04-21: previous doc stated anchor-7 for write; empirically
|
||||
confirmed wrong — writing to anchor-7 shifts the anchor by 1 on every cycle.
|
||||
sample_rate → uint16 BE at anchor_pos - 6
|
||||
histogram_interval_sec → uint16 BE at anchor_pos - 4 (seconds; mode-gated to Histogram/Histogram+Continuous)
|
||||
Valid values: 2, 5, 15, 60, 300, 900 (= 2s, 5s, 15s, 1m, 5m, 15m)
|
||||
record_time → float32 BE at anchor_pos + 6
|
||||
|
||||
Channel block (anchored on b"Tran" with unit-string guard):
|
||||
geo_range → uint8 at tran_pos + 33 (confirmed 2026-04-20)
|
||||
0x00 = Normal 10.000 in/s, 0x01 = Sensitive 1.250 in/s
|
||||
Written to Tran, Vert, Long channel blocks (all three).
|
||||
adc_scale_factor → float32 BE at tran_pos + 28 (= 6.206053; do NOT write)
|
||||
trigger_level_geo → float32 BE at tran_pos + 34
|
||||
"in.\\x00" → unit string at tran_pos + 38 (layout guard)
|
||||
alarm_level_geo → float32 BE at tran_pos + 42
|
||||
"/s\\x00\\x00" → unit string at tran_pos + 46 (layout guard)
|
||||
NOTE: tran_pos+28 (float32 = 6.206053) is the ADC-to-velocity scale factor
|
||||
(= 1/sensitivity, (in/s)/V — Interface Handbook §4.5: 1.61133 V × 6.206053 = 10.000 in/s).
|
||||
This is a hardware/firmware constant common to all MiniMate Plus S3 units.
|
||||
It must NOT be written — do not add it back as a parameter.
|
||||
|
||||
String field locations (64-byte slots, label+22 format):
|
||||
b"Project:" → value at label_pos + 22, max 41 chars + null
|
||||
b"Client:" → value at label_pos + 22, max 41 chars + null
|
||||
b"User Name:" → value at label_pos + 22, max 41 chars + null
|
||||
b"Seis Loc:" → value at label_pos + 22, max 41 chars + null
|
||||
b"Extended Notes"→ value at label_pos + 22, max 41 chars + null
|
||||
|
||||
Returns:
|
||||
2128-byte write payload: patched 2126-byte buffer + 2-byte footer \\x00\\x00.
|
||||
(Checksum formula for the footer is unknown; \\x00\\x00 confirmed accepted
|
||||
by the device in POC test 2026-04-07.)
|
||||
|
||||
Raises:
|
||||
ValueError: if raw is shorter than the minimum needed for the 3-chunk write.
|
||||
"""
|
||||
# Total size is nominally ~2126 bytes but varies by ±1-2 bytes depending on
|
||||
# DLE jitter in the E5 read response (0x10 bytes in the config data cause
|
||||
# 1-byte expansions per occurrence during DLE stuffing/unstuffing). The
|
||||
# anchor-based field access and the chunk splitter (fixed chunk1=1027,
|
||||
# chunk2=1055, chunk3=remainder) both handle variable length correctly.
|
||||
# Only enforce a minimum — must have at least chunk1+chunk2 bytes of content.
|
||||
_MIN_COMPLIANCE_LEN = 1027 + 1055 # = 2082
|
||||
if len(raw) < _MIN_COMPLIANCE_LEN:
|
||||
raise ValueError(
|
||||
f"_encode_compliance_config: compliance buffer too short "
|
||||
f"({len(raw)} bytes, need at least {_MIN_COMPLIANCE_LEN})"
|
||||
)
|
||||
if len(raw) not in range(2124, 2132):
|
||||
log.warning(
|
||||
"_encode_compliance_config: unusual compliance buffer length %d "
|
||||
"(expected ~2126); proceeding with anchor-based access",
|
||||
len(raw),
|
||||
)
|
||||
|
||||
buf = bytearray(raw)
|
||||
|
||||
# ── Numeric: recording_mode + sample_rate + record_time (anchor-relative) ──
|
||||
_ANC = b'\xbe\x80\x00\x00\x00\x00'
|
||||
_anc = buf.find(_ANC, 0, 150)
|
||||
|
||||
# Log anchor position every time so we can detect unexpected shifts due to
|
||||
# DLE jitter or firmware differences. Expected position is ~15.
|
||||
if _anc < 0:
|
||||
log.warning(
|
||||
"_encode_compliance_config: anchor NOT FOUND in cfg[0:150] "
|
||||
"(buf len=%d) — all anchor-relative writes will be skipped",
|
||||
len(buf),
|
||||
)
|
||||
else:
|
||||
log.info(
|
||||
"_encode_compliance_config: anchor at cfg[%d] buf_len=%d "
|
||||
"(recording_mode@%d DLE_marker@%d sample_rate@%d:%d "
|
||||
"histogram_interval@%d:%d record_time@%d:%d)",
|
||||
_anc, len(buf),
|
||||
_anc - 8,
|
||||
_anc - 7,
|
||||
_anc - 6, _anc - 4,
|
||||
_anc - 4, _anc - 2,
|
||||
_anc + 6, _anc + 10,
|
||||
)
|
||||
|
||||
if recording_mode is not None:
|
||||
if _anc < 8:
|
||||
log.warning("_encode_compliance_config: anchor not found — cannot write recording_mode")
|
||||
else:
|
||||
# Write to anchor-8, same physical position as the E5 read format.
|
||||
# The byte at anchor-7 is a DLE marker (0x10) that the device firmware
|
||||
# regenerates in every E5 response — it must NOT be overwritten.
|
||||
# Writing to anchor-7 causes the device to add an extra byte on the
|
||||
# next read-back, drifting the anchor by +1 on every write cycle.
|
||||
# (CLAUDE.md "anchor-7 write" was incorrect — confirmed 2026-04-21)
|
||||
buf[_anc - 8] = recording_mode & 0xFF
|
||||
log.debug("_encode_compliance_config: recording_mode=0x%02X -> offset %d",
|
||||
recording_mode, _anc - 8)
|
||||
|
||||
if sample_rate is not None:
|
||||
if _anc < 6:
|
||||
log.warning("_encode_compliance_config: anchor not found — cannot write sample_rate")
|
||||
else:
|
||||
struct.pack_into(">H", buf, _anc - 6, sample_rate)
|
||||
log.debug("_encode_compliance_config: sample_rate=%d -> offset %d", sample_rate, _anc - 6)
|
||||
|
||||
if histogram_interval_sec is not None:
|
||||
if _anc < 4:
|
||||
log.warning("_encode_compliance_config: anchor not found — cannot write histogram_interval")
|
||||
else:
|
||||
struct.pack_into(">H", buf, _anc - 4, histogram_interval_sec)
|
||||
log.debug("_encode_compliance_config: histogram_interval=%ds -> offset %d",
|
||||
histogram_interval_sec, _anc - 4)
|
||||
|
||||
if record_time is not None:
|
||||
if _anc < 0 or _anc + 10 > len(buf):
|
||||
log.warning("_encode_compliance_config: anchor not found — cannot write record_time")
|
||||
else:
|
||||
struct.pack_into(">f", buf, _anc + 6, record_time)
|
||||
log.debug("_encode_compliance_config: record_time=%.3f -> offset %d", record_time, _anc + 6)
|
||||
|
||||
# ── Numeric: channel block (Tran label + unit-string guard) ───────────────
|
||||
# NOTE: tran_pos+24 (write format) or tran_pos+28 (E5 read format) is the
|
||||
# ADC-to-velocity scale factor (6.206053, hardware constant — never written).
|
||||
# geo_range is written to ALL THREE geo channel blocks (Tran, Vert, Long),
|
||||
# confirmed from 4-20-26 captures showing the byte at label+29 in each block.
|
||||
_needs_channel = any(v is not None for v in (trigger_level_geo, alarm_level_geo, geo_range))
|
||||
if _needs_channel:
|
||||
_tran = buf.find(b"Tran", 44)
|
||||
_valid = (
|
||||
_tran >= 0
|
||||
and buf[_tran + 4 : _tran + 5] != b"2"
|
||||
and _tran + 50 <= len(buf)
|
||||
and buf[_tran + 38 : _tran + 42] == b"in.\x00"
|
||||
and buf[_tran + 46 : _tran + 50] == b"/s\x00\x00"
|
||||
)
|
||||
if not _valid:
|
||||
log.warning(
|
||||
"_encode_compliance_config: 'Tran' channel block not found or unit "
|
||||
"guard failed — trigger/alarm/geo_range will not be written"
|
||||
)
|
||||
else:
|
||||
if trigger_level_geo is not None:
|
||||
struct.pack_into(">f", buf, _tran + 34, trigger_level_geo)
|
||||
log.debug("_encode_compliance_config: trigger_level_geo=%.4f -> offset %d", trigger_level_geo, _tran + 34)
|
||||
if alarm_level_geo is not None:
|
||||
struct.pack_into(">f", buf, _tran + 42, alarm_level_geo)
|
||||
log.debug("_encode_compliance_config: alarm_level_geo=%.4f -> offset %d", alarm_level_geo, _tran + 42)
|
||||
if geo_range is not None:
|
||||
# Write geo_range to all three geo channel blocks (Tran, Vert, Long).
|
||||
# Field at label+33 in the E5-format compliance bytes (same in read and write
|
||||
# since the 2126-byte payload is round-tripped verbatim).
|
||||
# 0x00 = Normal 10.000 in/s, 0x01 = Sensitive 1.250 in/s.
|
||||
for _ch_label in (b"Tran", b"Vert", b"Long"):
|
||||
_ch = buf.find(_ch_label, 44)
|
||||
if _ch >= 0 and buf[_ch + 4 : _ch + 5] != b"2" and _ch + 34 <= len(buf):
|
||||
buf[_ch + 33] = geo_range & 0xFF
|
||||
log.debug(
|
||||
"_encode_compliance_config: geo_range=0x%02X -> %s+33 offset %d",
|
||||
geo_range, _ch_label.decode(), _ch + 33,
|
||||
)
|
||||
|
||||
# ── ASCII strings (64-byte slot, value at label_pos+22) ───────────────────
|
||||
def _set_string(label: bytes, value: Optional[str]) -> None:
|
||||
if value is None:
|
||||
return
|
||||
idx = buf.find(label)
|
||||
if idx < 0:
|
||||
log.warning("_encode_compliance_config: label %r not found", label)
|
||||
return
|
||||
val_bytes = value.encode("ascii", errors="replace")[:_COMPLIANCE_VALUE_MAX - 1]
|
||||
padded = val_bytes + b"\x00" * (_COMPLIANCE_VALUE_MAX - len(val_bytes))
|
||||
buf[idx + _COMPLIANCE_VALUE_OFFSET : idx + _COMPLIANCE_SLOT_SIZE] = padded
|
||||
log.debug("_encode_compliance_config: %r -> %r", label, value)
|
||||
|
||||
_set_string(b"Project:", project)
|
||||
_set_string(b"Client:", client_name)
|
||||
_set_string(b"User Name:", operator)
|
||||
_set_string(b"Seis Loc:", seis_loc)
|
||||
_set_string(b"Extended Notes", notes)
|
||||
|
||||
# ── Read-back check: the payload must decode to what was asked ────────────
|
||||
# The decoder is the measured layout (every recorded reply); these offsets are
|
||||
# 1024-sps raw ones. A mode change on BE9441's 10-25 Continuous / 4096 block
|
||||
# rewrote the byte in front of the mode and read back unchanged. Refuse it
|
||||
# here, before push_config_raw sends anything.
|
||||
asked = {"recording_mode": recording_mode, "sample_rate": sample_rate,
|
||||
"histogram_interval_sec": histogram_interval_sec, "record_time": record_time}
|
||||
if any(v is not None for v in asked.values()):
|
||||
before, after = _settings_read_back(raw), _settings_read_back(bytes(buf))
|
||||
if record_time is not None:
|
||||
asked["record_time"] = struct.unpack(">f", struct.pack(">f", record_time))[0]
|
||||
want = {k: (v if v is not None else before[k]) for k, v in asked.items()}
|
||||
wrong = {k: (after[k], want[k]) for k in asked if after[k] != want[k]}
|
||||
if wrong:
|
||||
raise ValueError(
|
||||
"_encode_compliance_config: the patched block would not read back as asked ("
|
||||
+ ", ".join(f"{k} reads {got!r}, not {exp!r}" for k, (got, exp) in wrong.items())
|
||||
+ ") -- refused, nothing built or sent. The encoder's offsets were measured at "
|
||||
"1024 sps and need rewriting on unescaped bytes (#46)."
|
||||
)
|
||||
|
||||
# 2-byte footer — checksum formula unknown; \x00\x00 confirmed accepted by device
|
||||
return bytes(buf) + b"\x00\x00"
|
||||
|
||||
|
||||
def _settings_read_back(data: bytes) -> dict:
|
||||
"""Mode, sample rate, interval and record time as the decoder reads `data`."""
|
||||
info = DeviceInfo(serial="", firmware_minor=0)
|
||||
_decode_compliance_config_into(data, info)
|
||||
cc = info.compliance_config
|
||||
return {k: getattr(cc, k, None) if cc is not None else None
|
||||
for k in ("recording_mode", "sample_rate", "histogram_interval_sec", "record_time")}
|
||||
|
||||
|
||||
def _decode_compliance_config_into(data: bytes, info: DeviceInfo) -> None:
|
||||
|
||||
@@ -1,68 +0,0 @@
|
||||
"""
|
||||
poc_set_project.py — POC test for set_project_info() against a live MiniMate Plus.
|
||||
|
||||
Usage:
|
||||
python poc_set_project.py [--host IP] [--port PORT]
|
||||
|
||||
Default target: BE11529 at 63.43.212.232:9034
|
||||
"""
|
||||
|
||||
import argparse
|
||||
import logging
|
||||
import sys
|
||||
|
||||
logging.basicConfig(
|
||||
level=logging.DEBUG,
|
||||
format="%(asctime)s %(levelname)-7s %(name)s %(message)s",
|
||||
datefmt="%H:%M:%S",
|
||||
)
|
||||
log = logging.getLogger("poc_set_project")
|
||||
|
||||
from minimateplus import MiniMateClient
|
||||
from minimateplus.transport import TcpTransport
|
||||
|
||||
|
||||
DEFAULT_HOST = "63.43.212.232"
|
||||
DEFAULT_PORT = 9034
|
||||
|
||||
|
||||
def main() -> None:
|
||||
ap = argparse.ArgumentParser(description="POC: write project info to MiniMate Plus")
|
||||
ap.add_argument("--host", default=DEFAULT_HOST, help="Modem IP address")
|
||||
ap.add_argument("--port", type=int, default=DEFAULT_PORT, help="TCP port")
|
||||
ap.add_argument("--project", default="POC Write Test")
|
||||
ap.add_argument("--client-name", default="Terra-Mechanics Inc.")
|
||||
ap.add_argument("--operator", default="B. Harrison")
|
||||
ap.add_argument("--seis-loc", default="Lab Bench - POC")
|
||||
ap.add_argument("--notes", default="set_project_info POC 2026-04-07")
|
||||
args = ap.parse_args()
|
||||
|
||||
log.info("Connecting to %s:%d", args.host, args.port)
|
||||
transport = TcpTransport(args.host, port=args.port)
|
||||
|
||||
with MiniMateClient(transport=transport, timeout=60.0) as client:
|
||||
log.info("Performing POLL handshake + identity read …")
|
||||
info = client.connect()
|
||||
log.info("Connected: serial=%s firmware=%s", info.serial, info.firmware_version)
|
||||
|
||||
log.info("Calling set_project_info() …")
|
||||
client.set_project_info(
|
||||
project=args.project,
|
||||
client_name=args.client_name,
|
||||
operator=args.operator,
|
||||
seis_loc=args.seis_loc,
|
||||
notes=args.notes,
|
||||
)
|
||||
log.info("set_project_info() returned — write sequence complete")
|
||||
|
||||
log.info("Done. Reconnect Blastware to verify the fields were written.")
|
||||
|
||||
|
||||
if __name__ == "__main__":
|
||||
try:
|
||||
main()
|
||||
except KeyboardInterrupt:
|
||||
sys.exit(0)
|
||||
except Exception as exc:
|
||||
log.exception("Fatal: %s", exc)
|
||||
sys.exit(1)
|
||||
@@ -9,7 +9,7 @@ import threading
|
||||
import time
|
||||
from typing import Any, Callable, Dict, Optional
|
||||
|
||||
from .errors import ConnectFailed, DeviceError, NoAnswer, NotSupported, WrongUnit
|
||||
from .errors import BadRequest, ConnectFailed, DeviceError, NoAnswer, NotSupported, WrongUnit
|
||||
from .events import parse_event_id
|
||||
from .locks import UnitLocks
|
||||
from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, UnitAddress, UnitInfo,
|
||||
@@ -17,6 +17,7 @@ from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, Un
|
||||
from .s3 import Series3Adapter, default_s3_client_factory
|
||||
from .s4 import (
|
||||
Series4Session, default_s4_client_factory, s4_call_home_state, s4_change_call_home, s4_change_monitoring,
|
||||
s4_change_settings,
|
||||
s4_download_event, s4_identify, s4_list_events, s4_settings, s4_status,
|
||||
)
|
||||
from .series import normalise_serial, series_for_serial
|
||||
@@ -27,6 +28,9 @@ log = logging.getLogger("sfm.device_access")
|
||||
# reads, a second apart -- not the start/stop window.
|
||||
_CALL_HOME_VERIFY_TIMEOUT_S = 3.0
|
||||
_CALL_HOME_VERIFY_INTERVAL_S = 1.0
|
||||
# A settings read-back is one block read (seconds over cellular): two tries, a second apart.
|
||||
_SETTINGS_VERIFY_TIMEOUT_S = 2.0
|
||||
_SETTINGS_VERIFY_INTERVAL_S = 1.0
|
||||
|
||||
|
||||
class DeviceAccess:
|
||||
@@ -140,6 +144,34 @@ class DeviceAccess:
|
||||
lambda c, s: s4_change_call_home(c, s, address=address, **kw),
|
||||
change=True)
|
||||
|
||||
def change_settings(self, address: UnitAddress, serial: str, *, changes: dict,
|
||||
revision: Optional[str], dry_run: bool = False,
|
||||
caller: str = "api") -> ChangeResult:
|
||||
"""Change the unit's settings (spec row 10, phase 5). A dry run is the
|
||||
preview: old -> new per field and a `revision`. A live change needs that
|
||||
revision; it is audited, identity-checked, sent once, never retried, and
|
||||
read back. Refused before any I/O: no changes, a live call without a
|
||||
revision, no audit log."""
|
||||
serial = normalise_serial(serial)
|
||||
series_for_serial(serial) # BadRequest (422) before anything else
|
||||
if not isinstance(changes, dict) or not changes:
|
||||
raise BadRequest("no settings to change -- nothing sent")
|
||||
if not dry_run and not revision:
|
||||
raise BadRequest("preview first: a live change needs the revision from its preview "
|
||||
"-- nothing sent")
|
||||
if not dry_run and self._audit is None:
|
||||
raise NotSupported("no audit log is configured -- SFM refuses to change a unit "
|
||||
"without one (nothing sent)")
|
||||
kw = dict(changes=changes, revision=revision, dry_run=dry_run, audit=self._audit,
|
||||
caller=caller, sleep=self._sleep,
|
||||
verify_timeout_s=_SETTINGS_VERIFY_TIMEOUT_S,
|
||||
verify_interval_s=_SETTINGS_VERIFY_INTERVAL_S)
|
||||
return self._dispatch(
|
||||
address, serial,
|
||||
lambda a, s: self._s3.change_settings(a, s, **kw),
|
||||
lambda c, s: s4_change_settings(c, s, address=address, **kw),
|
||||
change=True)
|
||||
|
||||
def held_serial(self, address: UnitAddress) -> Optional[str]:
|
||||
"""Serial of the OPEN held Series-4 line at this address, else None. No I/O."""
|
||||
with self._sessions_guard:
|
||||
|
||||
+50
-133
@@ -50,7 +50,7 @@ import tempfile
|
||||
import threading
|
||||
import time
|
||||
from pathlib import Path
|
||||
from typing import Mapping, Optional
|
||||
from typing import Any, Dict, Mapping, Optional
|
||||
|
||||
# FastAPI / Pydantic
|
||||
try:
|
||||
@@ -426,6 +426,7 @@ _SERIAL_AWARE_PATHS = frozenset({
|
||||
"/device/events", "/device/events/download",
|
||||
"/device/monitor/start", "/device/monitor/stop",
|
||||
"/device/call_home/state", "/device/call_home/enable", "/device/call_home/disable",
|
||||
"/device/settings/change",
|
||||
})
|
||||
|
||||
|
||||
@@ -1112,145 +1113,61 @@ def device_event_blastware_file(
|
||||
|
||||
# ── Write endpoints ───────────────────────────────────────────────────────────
|
||||
|
||||
class DeviceConfigBody(BaseModel):
|
||||
"""
|
||||
Request body for POST /device/config.
|
||||
|
||||
All fields are optional — only supplied (non-null) fields are written to
|
||||
the device. All other config bytes are round-tripped verbatim.
|
||||
|
||||
Recording parameters
|
||||
--------------------
|
||||
recording_mode : Recording mode enum. Values: 0=Single Shot, 1=Continuous, 3=Histogram, 4=Histogram+Continuous.
|
||||
sample_rate : Samples per second. Valid values: 1024, 2048, 4096.
|
||||
record_time : Record duration in seconds (e.g. 1.0, 2.0, 3.0).
|
||||
|
||||
Trigger / alarm thresholds and range (geo channels)
|
||||
----------------------------------------------------
|
||||
trigger_level_geo : Trigger threshold in in/s (e.g. 0.5).
|
||||
alarm_level_geo : Alarm threshold in in/s (e.g. 1.0).
|
||||
geo_range : Geophone range/sensitivity. 0=Normal 10.000 in/s, 1=Sensitive 1.250 in/s.
|
||||
Project / operator strings (max 41 ASCII characters each)
|
||||
----------------------------
|
||||
project : Project description.
|
||||
client_name : Client / company name.
|
||||
operator : Operator / technician name.
|
||||
seis_loc : Sensor location description.
|
||||
notes : Extended notes.
|
||||
"""
|
||||
# Recording parameters
|
||||
recording_mode: Optional[int] = None
|
||||
sample_rate: Optional[int] = None
|
||||
record_time: Optional[float] = None
|
||||
histogram_interval_sec: Optional[int] = None # seconds: 2, 5, 15, 60, 300, 900 (mode-gated)
|
||||
# Threshold parameters / geo range
|
||||
trigger_level_geo: Optional[float] = None
|
||||
alarm_level_geo: Optional[float] = None
|
||||
geo_range: Optional[int] = None # 0=Normal 10.000 in/s, 1=Sensitive 1.250 in/s
|
||||
# Project / operator strings
|
||||
project: Optional[str] = None
|
||||
client_name: Optional[str] = None
|
||||
operator: Optional[str] = None
|
||||
seis_loc: Optional[str] = None
|
||||
notes: Optional[str] = None
|
||||
_CONFIG_RETIRED = ("retired: change a unit's settings by serial with POST /device/settings/change "
|
||||
"(audited, previewed, read back)")
|
||||
|
||||
|
||||
@app.post("/device/config")
|
||||
def device_config(
|
||||
body: DeviceConfigBody,
|
||||
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
|
||||
baud: int = Query(38400, description="Serial baud rate"),
|
||||
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
|
||||
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
|
||||
serial: Optional[str] = Query(None, description=_SERIAL_CHECK_DOC),
|
||||
) -> dict:
|
||||
"""
|
||||
Read the current device config, apply any supplied changes to the compliance
|
||||
block, and write the full config back.
|
||||
|
||||
Only non-null fields in the JSON body are modified. All other config bytes
|
||||
are round-tripped verbatim from the device.
|
||||
|
||||
Supply either *port* (serial) or *host* (TCP/modem).
|
||||
|
||||
Example body (all fields optional — include only what you want to change):
|
||||
{
|
||||
"recording_mode": 1,
|
||||
"sample_rate": 1024,
|
||||
"record_time": 3.0,
|
||||
"trigger_level_geo": 0.5,
|
||||
"alarm_level_geo": 1.0,
|
||||
"project": "Bridge Inspection 2026",
|
||||
"client_name": "City of Portland",
|
||||
"operator": "Brian Harrison",
|
||||
"seis_loc": "South Abutment",
|
||||
"notes": "Pre-blast baseline"
|
||||
}
|
||||
|
||||
Returns:
|
||||
{"status": "ok", "updated_fields": {...}} on success.
|
||||
|
||||
Raises:
|
||||
502 on protocol errors (timeout, bad ack, etc.).
|
||||
422 if neither port nor host is provided.
|
||||
"""
|
||||
changed = body.model_dump(exclude_none=True)
|
||||
conn_key = _live_cache.make_conn_key(host, tcp_port, port, baud)
|
||||
log.info("POST /device/config port=%s host=%s fields=%s", port, host, list(changed.keys()))
|
||||
|
||||
try:
|
||||
def _do():
|
||||
with _build_client(port, baud, host, tcp_port) as client:
|
||||
info = client.connect()
|
||||
_require_series3(info.serial, serial)
|
||||
client.apply_config(
|
||||
recording_mode=body.recording_mode,
|
||||
sample_rate=body.sample_rate,
|
||||
record_time=body.record_time,
|
||||
histogram_interval_sec=body.histogram_interval_sec,
|
||||
trigger_level_geo=body.trigger_level_geo,
|
||||
alarm_level_geo=body.alarm_level_geo,
|
||||
geo_range=body.geo_range,
|
||||
project=body.project,
|
||||
client_name=body.client_name,
|
||||
operator=body.operator,
|
||||
seis_loc=body.seis_loc,
|
||||
notes=body.notes,
|
||||
)
|
||||
_run_with_retry(_do, is_tcp=_is_tcp(host))
|
||||
except HTTPException:
|
||||
raise
|
||||
except ProtocolError as exc:
|
||||
raise HTTPException(status_code=502, detail=f"Protocol error: {exc}") from exc
|
||||
except OSError as exc:
|
||||
raise HTTPException(status_code=502, detail=f"Connection error: {exc}") from exc
|
||||
except ValueError as exc:
|
||||
raise HTTPException(status_code=422, detail=str(exc)) from exc
|
||||
except Exception as exc:
|
||||
raise HTTPException(status_code=500, detail=f"Device error: {exc}") from exc
|
||||
|
||||
# Config was written to the device — the cached compliance config is now stale.
|
||||
conn_key = SFMCache.make_conn_key(host, tcp_port, port, baud)
|
||||
get_cache().mark_config_dirty(conn_key)
|
||||
|
||||
return {
|
||||
"status": "ok",
|
||||
"updated_fields": changed,
|
||||
}
|
||||
def device_config() -> JSONResponse:
|
||||
"""Retired (phase 5, 2026-11-03). It wrote a MiniMate's settings through an
|
||||
encoder #46 found wrong, unaudited, with no read-back, retrying the whole
|
||||
write on a TCP error. Use POST /device/settings/change."""
|
||||
return JSONResponse(status_code=410, content={"detail": _CONFIG_RETIRED})
|
||||
|
||||
|
||||
# Keep the old endpoint alive under its old URL for anything already calling it
|
||||
@app.post("/device/config/project")
|
||||
def device_config_project(
|
||||
body: DeviceConfigBody,
|
||||
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
|
||||
baud: int = Query(38400, description="Serial baud rate"),
|
||||
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
|
||||
def device_config_project() -> JSONResponse:
|
||||
"""Retired with POST /device/config -- use POST /device/settings/change."""
|
||||
return JSONResponse(status_code=410, content={"detail": _CONFIG_RETIRED})
|
||||
|
||||
|
||||
class SettingsChangeBody(BaseModel):
|
||||
"""POST /device/settings/change. `changes` maps field -> new value, using
|
||||
the field names in GET /device/settings' `detail.editable`. `revision` is the
|
||||
one a dry run (the preview) returned; a live change without it is refused."""
|
||||
changes: Dict[str, Any]
|
||||
revision: Optional[str] = None
|
||||
|
||||
|
||||
@app.post("/device/settings/change")
|
||||
def device_settings_change(
|
||||
body: SettingsChangeBody,
|
||||
serial: str = Query(..., description=_SERIAL_DOC),
|
||||
host: Optional[str] = Query(None, description="TCP host — modem IP"),
|
||||
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
|
||||
serial: Optional[str] = Query(None, description=_SERIAL_CHECK_DOC),
|
||||
) -> dict:
|
||||
"""Deprecated alias for POST /device/config — use that instead."""
|
||||
return device_config(body=body, port=port, baud=baud, host=host, tcp_port=tcp_port, serial=serial)
|
||||
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
|
||||
baud: Optional[int] = Query(None, description="Serial baud rate"),
|
||||
dry_run: bool = Query(False, description="Preview: old -> new and a revision; send nothing"),
|
||||
caller: Optional[str] = Query(None, description="Who is asking (recorded in the audit row)"),
|
||||
):
|
||||
"""Change a unit's settings by serial, both series (spec row 10, phase 5).
|
||||
|
||||
Preview first (`dry_run=true`): it reads the unit and returns, per field, the
|
||||
value it holds and the value it would get, any warnings, anything that blocks
|
||||
the change, and a `revision`. Then send the same body live with that
|
||||
revision: identity read first, refused if the unit is monitoring or its
|
||||
settings changed since the preview (409), sent once, never retried, read back.
|
||||
Statuses as /device/monitor/start; a change that went out but was not
|
||||
confirmed carries `sent` and `audit_id`."""
|
||||
resp = _change_response(lambda: _device_access().change_settings(
|
||||
_unit_address(port, baud, host, tcp_port), serial, changes=body.changes,
|
||||
revision=body.revision, dry_run=dry_run, caller=caller or "api"))
|
||||
if not dry_run:
|
||||
try: # a by-host read must not serve stale settings
|
||||
get_cache().mark_config_dirty(_live_cache.make_conn_key(host, tcp_port, port, baud))
|
||||
except Exception as exc: # noqa: BLE001 -- the change's answer stands
|
||||
log.warning("could not mark the cached config dirty: %s", exc)
|
||||
return resp
|
||||
|
||||
|
||||
# ── Monitoring endpoints ───────────────────────────────────────────────────────
|
||||
|
||||
@@ -0,0 +1,70 @@
|
||||
"""DeviceAccess.change_settings (phase 5): the series-independent entry point --
|
||||
what it refuses before any I/O, and that it dispatches a change (never retried)."""
|
||||
from __future__ import annotations
|
||||
|
||||
import os
|
||||
import sys
|
||||
|
||||
import pytest
|
||||
|
||||
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||||
|
||||
from device_access_fakes import FakeMiniMateClient, FakeMicromateClient # noqa: E402
|
||||
from sfm.device_access.access import DeviceAccess # noqa: E402
|
||||
from sfm.device_access.errors import BadRequest, NotSupported # noqa: E402
|
||||
from sfm.device_access.models import UnitAddress # noqa: E402
|
||||
|
||||
ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None)
|
||||
|
||||
|
||||
class Audit:
|
||||
def __init__(self):
|
||||
self.rows = {}
|
||||
|
||||
def begin(self, **f):
|
||||
cid = f"c{len(self.rows) + 1}"
|
||||
self.rows[cid] = dict(f, outcome="pending")
|
||||
return cid
|
||||
|
||||
def finish(self, cid, **f):
|
||||
self.rows[cid].update(f)
|
||||
|
||||
|
||||
def _never(*a, **kw):
|
||||
raise AssertionError("no connection may be opened")
|
||||
|
||||
|
||||
def _access(s3=_never, s4=_never, audit="default"):
|
||||
return DeviceAccess(s3_client_factory=s3, s4_client_factory=s4, start_reaper=False,
|
||||
audit=Audit() if audit == "default" else audit, sleep=lambda s: None)
|
||||
|
||||
|
||||
def test_live_change_without_revision_is_refused_before_io():
|
||||
with pytest.raises(BadRequest, match="preview first"):
|
||||
_access().change_settings(ADDR, "UM20147", changes={"job_number": 7}, revision=None)
|
||||
|
||||
|
||||
@pytest.mark.parametrize("changes", [{}, None, "job_number=7"])
|
||||
def test_empty_changes_is_a_bad_request(changes):
|
||||
with pytest.raises(BadRequest):
|
||||
_access().change_settings(ADDR, "BE18193", changes=changes, revision="r", dry_run=True)
|
||||
|
||||
|
||||
def test_a_live_change_without_an_audit_log_is_refused():
|
||||
with pytest.raises(NotSupported, match="audit"):
|
||||
_access(audit=None).change_settings(ADDR, "BE18193", changes={"job_number": 7}, revision="r")
|
||||
|
||||
|
||||
def test_change_settings_dispatches_by_series_with_change_true(monkeypatch):
|
||||
access = _access(s3=lambda a, **kw: FakeMiniMateClient(), s4=lambda a, **kw: FakeMicromateClient())
|
||||
seen = []
|
||||
real = access._dispatch
|
||||
|
||||
def spy(address, serial, s3_op, s4_op, *, change=False):
|
||||
seen.append((serial, change))
|
||||
return real(address, serial, s3_op, s4_op, change=change)
|
||||
monkeypatch.setattr(access, "_dispatch", spy)
|
||||
r3 = access.change_settings(ADDR, "be18193", changes={"job_number": 7}, revision=None, dry_run=True)
|
||||
r4 = access.change_settings(ADDR, "UM20147", changes={"job_number": 7}, revision=None, dry_run=True)
|
||||
assert (r3.series, r4.series) == (3, 4) and r3.outcome == r4.outcome == "dry_run"
|
||||
assert seen == [("BE18193", True), ("UM20147", True)]
|
||||
@@ -213,40 +213,8 @@ def test_each_read_returns_the_block_blastware_then_wrote(read, sub, size):
|
||||
assert block[:-2] == want[:-2] if sub == 0x69 else block == want[:-2]
|
||||
|
||||
|
||||
# -- apply_config writes this unit's own trigger block ---------------------------
|
||||
|
||||
class StubProto:
|
||||
"""Serves BE9441's blocks as read on 2026-10-26; records every write."""
|
||||
|
||||
def __init__(self):
|
||||
self.writes = []
|
||||
|
||||
def read_event_index(self):
|
||||
return _image(0x68)[:-2]
|
||||
|
||||
def read_compliance_config(self):
|
||||
return _image(0x71)[:-2]
|
||||
|
||||
def read_waveform_data_raw(self):
|
||||
return _image(0x69)
|
||||
|
||||
def read_trigger_config(self):
|
||||
return _image(0x82)[:-2]
|
||||
|
||||
def __getattr__(self, name):
|
||||
if name.startswith("write_"):
|
||||
return lambda *a, **k: self.writes.append((name, a))
|
||||
raise AttributeError(name)
|
||||
|
||||
|
||||
def test_apply_config_writes_the_units_own_trigger_block():
|
||||
from minimateplus.client import MiniMateClient
|
||||
c = MiniMateClient(transport=object())
|
||||
c._proto = StubProto()
|
||||
c.apply_config() # nothing changed: a round trip
|
||||
trig = [a[0] for n, a in c._proto.writes if n == "write_trigger_config"]
|
||||
assert trig == [_image(0x82)[:-2]]
|
||||
assert trig[0][5] == 0x01 # BE9441's; the March copy had 0x03
|
||||
# -- the unit's own trigger block is sent back: tests/test_device_access_s3_settings.py
|
||||
# (test_s3_trigger_change_sends_the_units_own_blocks), phase 5.
|
||||
|
||||
|
||||
def test_a_bad_block_is_refused_before_the_first_write_goes_out():
|
||||
|
||||
@@ -96,30 +96,5 @@ def test_a_reply_without_the_settings_block_reads_as_unknown():
|
||||
(None, None, None, None)
|
||||
|
||||
|
||||
# The write side (review finding, 2026-10-29). _encode_compliance_config patches
|
||||
# the RAW bytes at offsets measured at 1024 sps (April 2026), where an escape sits
|
||||
# between the mode and the anchor. At other rates the mode is one byte later, so
|
||||
# a mode change rewrote the byte in front of it. A payload that would not read
|
||||
# back as asked is refused before anything is sent.
|
||||
|
||||
from minimateplus.client import _encode_compliance_config # noqa: E402
|
||||
|
||||
|
||||
def _block(i):
|
||||
return _settings_replies()[i].ljust(2126, b"\x00") # a whole block's length
|
||||
|
||||
|
||||
@pytest.mark.parametrize("i, change", [
|
||||
(0, {"recording_mode": 0}), # 10-25 Continuous / 4096: mode sits at -7, not -8
|
||||
(1, {"sample_rate": 4096}), # 10-26 Histogram+Continuous / 2048: escaped mode shifts the rate
|
||||
])
|
||||
def test_a_change_that_would_not_read_back_is_refused(i, change):
|
||||
with pytest.raises(ValueError, match="read back"):
|
||||
_encode_compliance_config(_block(i), **change)
|
||||
|
||||
|
||||
def test_a_change_that_reads_back_as_asked_is_built():
|
||||
out = _encode_compliance_config(_block(0), record_time=7.0)
|
||||
cc = _decode(out)
|
||||
assert (cc.recording_mode, cc.sample_rate, cc.histogram_interval_sec, cc.record_time) == \
|
||||
(1, 4096, 5, 7.0)
|
||||
# The write side moved to the shared settings codec in phase 5 (2026-11-03):
|
||||
# tests/test_setup_fields.py reproduces every Blastware write byte for byte.
|
||||
@@ -23,7 +23,7 @@ from fastapi import HTTPException # noqa: E402
|
||||
|
||||
import sfm.server as srv # noqa: E402
|
||||
|
||||
WRITES = {"delete_all_events", "apply_config", "set_call_home_config", "stop_monitoring"}
|
||||
WRITES = {"delete_all_events", "set_call_home_config", "stop_monitoring"}
|
||||
ADDR = dict(port=None, baud=38400, host="10.0.0.9", tcp_port=9034)
|
||||
|
||||
|
||||
@@ -56,9 +56,6 @@ class Unit:
|
||||
def delete_all_events(self):
|
||||
self._rec("delete_all_events")
|
||||
|
||||
def apply_config(self, **kw):
|
||||
self._rec("apply_config")
|
||||
|
||||
def set_call_home_config(self, **kw):
|
||||
self._rec("set_call_home_config")
|
||||
|
||||
@@ -72,8 +69,6 @@ class Cache:
|
||||
|
||||
|
||||
def _call(route, serial):
|
||||
if route == "config":
|
||||
return srv.device_config(body=srv.DeviceConfigBody(), serial=serial, **ADDR)
|
||||
if route == "erase":
|
||||
return srv.device_events_erase(serial=serial, **ADDR)
|
||||
if route == "rescue":
|
||||
@@ -98,7 +93,7 @@ def unit(monkeypatch):
|
||||
return make
|
||||
|
||||
|
||||
ROUTES = ["config", "erase", "rescue", "call_home"]
|
||||
ROUTES = ["erase", "rescue", "call_home"] # /device/config is retired (410)
|
||||
|
||||
|
||||
@pytest.mark.parametrize("route", ROUTES)
|
||||
@@ -131,8 +126,8 @@ def test_guarded_route_proceeds_for_the_named_series3_unit(unit, route):
|
||||
|
||||
|
||||
def test_the_identity_check_reuses_connects_serial_where_there_is_one(unit):
|
||||
# speed: config and erase already read the serial in connect(); no extra read
|
||||
for route in ("config", "erase"):
|
||||
# speed: erase already reads the serial in connect(); no extra read
|
||||
for route in ("erase",):
|
||||
u = unit("BE9441")
|
||||
_call(route, None)
|
||||
assert "read_serial" not in u.calls
|
||||
|
||||
@@ -0,0 +1,153 @@
|
||||
"""POST /device/settings/change (phase 5), and the legacy config write retired.
|
||||
Handlers are called directly, every parameter passed, as in
|
||||
test_server_device_access.py."""
|
||||
from __future__ import annotations
|
||||
|
||||
import json
|
||||
import os
|
||||
import sys
|
||||
|
||||
import pytest
|
||||
|
||||
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||||
|
||||
import micromate.protocol as mm_proto # noqa: E402
|
||||
import sfm.server as srv # noqa: E402
|
||||
from device_access_fakes import FakeMicromateClient, schedule_record # noqa: E402
|
||||
from fastapi import HTTPException # noqa: E402
|
||||
from sfm.device_access.access import DeviceAccess # noqa: E402
|
||||
|
||||
TCP = dict(port=None, baud=None, host="10.0.0.5", tcp_port=9034)
|
||||
|
||||
|
||||
class Audit:
|
||||
def __init__(self):
|
||||
self.rows = {}
|
||||
|
||||
def begin(self, **f):
|
||||
cid = f"c{len(self.rows) + 1}"
|
||||
self.rows[cid] = dict(f, outcome="pending")
|
||||
return cid
|
||||
|
||||
def finish(self, cid, **f):
|
||||
self.rows[cid].update(f)
|
||||
|
||||
|
||||
class Cache:
|
||||
def __init__(self):
|
||||
self.dirty = []
|
||||
|
||||
def mark_config_dirty(self, key):
|
||||
self.dirty.append(key)
|
||||
|
||||
|
||||
@pytest.fixture
|
||||
def unit(monkeypatch):
|
||||
def make(fake):
|
||||
access = DeviceAccess(s4_client_factory=lambda a, **kw: fake, start_reaper=False,
|
||||
audit=Audit(), sleep=lambda s: None)
|
||||
monkeypatch.setattr(srv, "_device_access_instance", access)
|
||||
cache = Cache()
|
||||
monkeypatch.setattr(srv, "get_cache", lambda: cache)
|
||||
return cache
|
||||
return make
|
||||
|
||||
|
||||
def _post(changes, *, revision=None, dry_run=False, serial="UM20147"):
|
||||
return srv.device_settings_change(body=srv.SettingsChangeBody(changes=changes, revision=revision),
|
||||
serial=serial, dry_run=dry_run, caller="test", **TCP)
|
||||
|
||||
|
||||
def _body(resp):
|
||||
return json.loads(resp.body)
|
||||
|
||||
|
||||
def test_route_dry_run_returns_fields_and_revision(unit):
|
||||
cache = unit(FakeMicromateClient())
|
||||
resp = _post({"geo_trigger_ips": 0.3}, dry_run=True)
|
||||
body = _body(resp)
|
||||
assert resp.status_code == 200 and body["outcome"] == "dry_run"
|
||||
assert body["plan"]["fields"]["geo_trigger_ips"] == {"label": "Geophone trigger", "old": 0.5, "new": 0.3}
|
||||
assert len(body["plan"]["revision"]) == 16 and cache.dirty == []
|
||||
|
||||
|
||||
def test_route_verified_change_is_200_and_mismatch_409(unit, monkeypatch):
|
||||
fake = FakeMicromateClient()
|
||||
cache = unit(fake)
|
||||
rev = _body(_post({"geo_trigger_ips": 0.3}, dry_run=True))["plan"]["revision"]
|
||||
resp = _post({"geo_trigger_ips": 0.3}, revision=rev)
|
||||
assert resp.status_code == 200 and _body(resp)["state_after"] == "as asked"
|
||||
assert len(cache.dirty) == 1 # a by-host read must not serve stale settings
|
||||
# a unit that acks but stores something else reads back "differs": 409
|
||||
fake2 = FakeMicromateClient()
|
||||
unit(fake2)
|
||||
rev = _body(_post({"job_number": 7}, dry_run=True))["plan"]["revision"]
|
||||
real = fake2.protocol.execute
|
||||
|
||||
def wrong(plan):
|
||||
acks = real(plan)
|
||||
fake2.setup = fake2.setup[:40] + b"\x00\x08" + fake2.setup[42:]
|
||||
from micromate.setup_block import with_crc
|
||||
fake2.setup = with_crc(fake2.setup)
|
||||
return acks
|
||||
monkeypatch.setattr(fake2.protocol, "execute", wrong)
|
||||
resp = _post({"job_number": 7}, revision=rev)
|
||||
assert resp.status_code == 409 and _body(resp)["verified"] == "mismatch"
|
||||
|
||||
|
||||
def test_route_unconfirmed_carries_sent_and_audit_id(unit, monkeypatch):
|
||||
fake = FakeMicromateClient()
|
||||
unit(fake)
|
||||
rev = _body(_post({"geo_trigger_ips": 0.3}, dry_run=True))["plan"]["revision"]
|
||||
real = fake.protocol.execute
|
||||
|
||||
def then_drop(plan):
|
||||
acks = real(plan)
|
||||
fake.run_states = [0x03] # it began calling home before the read-back
|
||||
return acks
|
||||
monkeypatch.setattr(fake.protocol, "execute", then_drop)
|
||||
resp = _post({"geo_trigger_ips": 0.3}, revision=rev)
|
||||
body = _body(resp)
|
||||
assert body["sent"] == "acknowledged" and body["audit_id"]
|
||||
|
||||
|
||||
@pytest.mark.parametrize("fake_kw, match", [
|
||||
(dict(schedule_body=schedule_record(14, 0x02, "other.mmb") + bytes(264)), "other.mmb"),
|
||||
(dict(active_name="factory.MMB"), "factory setup"),
|
||||
(dict(run_states=[0x02]), "stop it first"),
|
||||
])
|
||||
def test_route_refusal_is_409_with_reason(unit, fake_kw, match):
|
||||
fake = FakeMicromateClient(**fake_kw)
|
||||
unit(fake)
|
||||
rev = "0000000000000000"
|
||||
if 0x02 not in fake.run_states: # a monitoring unit refuses the preview too
|
||||
rev = _body(_post({"geo_trigger_ips": 0.3}, dry_run=True))["plan"]["revision"]
|
||||
with pytest.raises(HTTPException) as e:
|
||||
_post({"geo_trigger_ips": 0.3}, revision=rev)
|
||||
assert e.value.status_code == 409 and match in str(e.value.detail)
|
||||
|
||||
|
||||
def test_route_stale_preview_is_409(unit):
|
||||
unit(FakeMicromateClient())
|
||||
with pytest.raises(HTTPException) as e:
|
||||
_post({"geo_trigger_ips": 0.3}, revision="0000000000000000")
|
||||
assert e.value.status_code == 409 and "preview again" in str(e.value.detail)
|
||||
|
||||
|
||||
def test_route_live_without_revision_is_422(unit):
|
||||
unit(FakeMicromateClient())
|
||||
with pytest.raises(HTTPException) as e:
|
||||
_post({"geo_trigger_ips": 0.3})
|
||||
assert e.value.status_code == 422 and "preview first" in str(e.value.detail)
|
||||
|
||||
|
||||
@pytest.mark.parametrize("route", ["device_config", "device_config_project"])
|
||||
def test_legacy_config_routes_are_gone(route, monkeypatch):
|
||||
monkeypatch.setattr(srv, "_build_client", lambda *a, **kw: pytest.fail("no client may be built"))
|
||||
resp = getattr(srv, route)()
|
||||
assert resp.status_code == 410 and "/device/settings/change" in _body(resp)["detail"]
|
||||
|
||||
|
||||
def test_settings_change_is_serial_aware():
|
||||
assert "/device/settings/change" in srv._SERIAL_AWARE_PATHS
|
||||
assert srv._device_guard("/device/settings/change", {"serial": "UM20147", "host": "h"}) is None
|
||||
Reference in new issue
Block a user