feat(sfm): POST /device/settings/change; retire the legacy config write

DeviceAccess.change_settings refuses before any I/O a request with no
changes, a live change without its preview's revision, or no audit log,
then dispatches the series' change (never retried).  The route returns
the preview (fields old -> new, warnings, blocked, revision) or the
result (fields old/new/now), statuses as the other changes, and marks
the cached by-host config dirty after a live change.

/device/config and /device/config/project now answer 410 with a pointer.
Deleted with them: MiniMateClient.apply_config / set_project_info and
the raw-offset _encode_compliance_config (#46 found it wrong), the
lab script poc_set_project.py and experiments.py's EXP6, both of which
wrote a live unit through it.  Git keeps them.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-03 21:51:20 -05:00
1 parent 66bb29b9d4
commit e8eabee4a2
10 files changed
+316 -749

No files matched your search

-107
View File
@@ -60,7 +60,6 @@ from minimateplus.framing import build_bw_frame, SESSION_RESET
from minimateplus.client import (
MiniMateClient,
_decode_compliance_config_into,
_encode_compliance_config,
)
from minimateplus.models import DeviceInfo
@@ -462,111 +461,6 @@ def exp_fewer_polls(host: str, port: int) -> tuple[str, str, dict]:
t.disconnect()
# ══════════════════════════════════════════════════════════════════════════════
# EXP6 — Compliance-only write (71×3→72), skip event index + trigger + waveform
# ══════════════════════════════════════════════════════════════════════════════
#
# Blastware's full write sequence: 68→73 | 71×3→72 | 82→83 | 69→74→72
# We want to know: can we write ONLY the compliance block (71×3→72)?
#
# Test procedure:
# 1. Read current compliance config (SUB 1A)
# 2. Patch the "notes" field to a test marker
# 3. Write ONLY 71×3→72 (skip 68, 73, 82, 83, 69, 74, final 72)
# 4. Read back (SUB 1A) and verify the change was written
# 5. Restore original value
#
# If PASS: we can push individual config fields without touching event index,
# trigger config, or waveform data — huge simplification.
# If FAIL: the device needs the full write sequence (may reject partial write).
#
# SAFETY: We restore original data in a finally block. If the restore write
# fails, the device will have the test marker in "notes" — harmless but visible.
_EXP6_MARKER = "[exp6-test]"
def exp_compliance_only(host: str, port: int) -> tuple[str, str, dict]:
"""Write compliance block alone (71×3→72), verify, and restore."""
client, info = connect_client(host, port)
original_raw: Optional[bytes] = None
try:
proto = client._proto
if proto is None:
return "FAIL", "Could not get protocol handle from client", {}
# 1. Read current compliance
print(" Reading current compliance config (SUB 1A)…")
original_raw = proto.read_compliance_config()
print(f" Got {len(original_raw)} bytes of compliance config")
# Find current notes value for display
info_obj = DeviceInfo()
_decode_compliance_config_into(original_raw, info_obj)
cc = info_obj.compliance_config
orig_notes = cc.notes if cc else "(unknown)"
print(f" Current notes field: {orig_notes!r}")
# 2. Build modified payload with test marker in notes
test_notes = _EXP6_MARKER
modified_raw = _encode_compliance_config(
original_raw,
notes=test_notes,
)
print(f" Encoded modified compliance payload ({len(modified_raw)} bytes)")
print(f" Patching notes: {orig_notes!r} → {test_notes!r}")
# 3. Write ONLY the compliance block: 71×3 → 72
print(" Writing compliance ONLY (71×3→72) — skipping 68/73/82/83/69/74…")
proto.write_compliance_config_raw(modified_raw)
print(" Write complete — device acked 71×3→72")
# 4. Read back and verify
print(" Reading back compliance config to verify…")
readback_raw = proto.read_compliance_config()
readback_info = DeviceInfo()
_decode_compliance_config_into(readback_raw, readback_info)
rb_cc = readback_info.compliance_config
readback_notes = rb_cc.notes if rb_cc else "(decode failed)"
print(f" Read-back notes: {readback_notes!r}")
write_worked = (readback_notes == test_notes)
print(f" Write verified: {write_worked}")
details = {
"original_notes": orig_notes,
"written_notes": test_notes,
"readback_notes": readback_notes,
"write_verified": write_worked,
}
if write_worked:
return "PASS", "Compliance-only write works! No event index or trigger writes needed.", details
else:
return "FAIL", f"Write was not reflected in read-back (got {readback_notes!r})", details
except ProtocolError as exc:
return "FAIL", f"Protocol error: {exc}", {}
finally:
# Restore original compliance data regardless of outcome
if original_raw is not None:
print(" Restoring original compliance config…")
try:
proto2 = client._proto
if proto2:
proto2.write_compliance_config_raw(
_encode_compliance_config(original_raw) # no-op patch = verbatim
)
print(" Restore complete")
else:
print(" WARNING: protocol handle gone — could not restore")
except Exception as exc_r:
print(f" WARNING: restore failed: {exc_r}")
client.close()
# ══════════════════════════════════════════════════════════════════════════════
# Registry + main
# ══════════════════════════════════════════════════════════════════════════════
EXPERIMENTS = {
@@ -575,7 +469,6 @@ EXPERIMENTS = {
"no_5a": ("EXP3", exp_no_5a, "Event record (0C) without bulk waveform (5A)"),
"skip_1e": ("EXP4", exp_skip_1e, "0A/0C with cached key — skip initial 1E"),
"fewer_polls": ("EXP5", exp_fewer_polls, "1 POLL before 5A instead of Blastware's 3"),
"compliance_only": ("EXP6", exp_compliance_only, "Compliance-only write (71×3→72), no other blocks"),
}
+2 -370
View File
@@ -70,15 +70,8 @@ S3_MONITORING_FLAGS = frozenset({0x10, 0x0B})
# ⚠ RETRACTED 2026-10-27 (#46): a trigger block "hardcoded from 3-11-26 -- no
# read exists, Blastware writes this fixed blob". Blastware reads it first (SUB
# 0x2E), and its byte 5 differs by unit and session (01 / 03 / 04 on record), so
# the copy changed that setting on any unit that differed. apply_config reads
# the unit's own block (MiniMateProtocol.read_trigger_config).
# Compliance ASCII slot format (confirmed from 3-11-26 capture + label search):
# Each label occupies a 64-byte slot.
# Value starts at slot_start + 22, max 42 bytes, null-padded.
_COMPLIANCE_SLOT_SIZE = 64
_COMPLIANCE_VALUE_OFFSET = 22
_COMPLIANCE_VALUE_MAX = _COMPLIANCE_SLOT_SIZE - _COMPLIANCE_VALUE_OFFSET # 42
# the copy changed that setting on any unit that differed. A settings write sends
# the unit's own block back (sfm.device_access.s3 change_settings, phase 5).
# ── MiniMateClient ────────────────────────────────────────────────────────────
@@ -997,120 +990,6 @@ class MiniMateClient:
log.info("push_config_raw: complete")
def apply_config(
self,
*,
# Recording parameters
recording_mode: Optional[int] = None,
sample_rate: Optional[int] = None,
record_time: Optional[float] = None,
histogram_interval_sec: Optional[int] = None,
# Threshold parameters (geo channels, in/s)
trigger_level_geo: Optional[float] = None,
alarm_level_geo: Optional[float] = None,
geo_range: Optional[int] = None, # 0x00=Normal 10in/s, 0x01=Sensitive 1.25in/s
# Project / operator strings
project: Optional[str] = None,
client_name: Optional[str] = None,
operator: Optional[str] = None,
seis_loc: Optional[str] = None,
notes: Optional[str] = None,
) -> None:
"""
Read the current device config, apply any supplied changes to the
compliance block, and write the full config back to the device.
Only non-None arguments are modified; all other bytes are round-tripped
verbatim from the device.
Configurable fields
-------------------
Recording parameters:
recording_mode : int — 0x00=Single Shot, 0x01=Continuous, 0x03=Histogram, 0x04=Histogram+Continuous
sample_rate : int — samples/sec; valid values: 1024, 2048, 4096
record_time : float — record duration in seconds (e.g. 2.0, 3.0)
Trigger/alarm thresholds and range (geo channels):
trigger_level_geo : float — trigger threshold in/s (e.g. 0.5)
alarm_level_geo : float — alarm threshold in/s (e.g. 1.0)
geo_range : int — 0x00=Normal 10.000 in/s, 0x01=Sensitive 1.250 in/s
(written to Tran/Vert/Long channel blocks)
Project / operator strings (max 41 ASCII characters each):
project : str
client_name : str
operator : str
seis_loc : str — sensor location
notes : str — extended notes
Write sequence (confirmed from 3-11-26 BW TX capture):
68→73 | 71×3→72 | 82→83 | 69→74→72
Write payloads:
event_index_data : 88 bytes — read live via SUB 08
compliance_data : ~2128 bytes — read live via SUB 1A (~2126 bytes, varies ±1-2) + \\x00\\x00 footer
trigger_data : 26 bytes — read live via SUB 2E (was hard-coded; #46)
waveform_data : 204 bytes — read live via SUB 09
Raises:
RuntimeError: if not connected.
ProtocolError: if any read or write step fails.
ValueError: if compliance buffer is shorter than the 2082-byte write minimum.
"""
proto = self._require_proto()
# 1. Read current payloads from the device
log.info("apply_config: reading event index (SUB 08)")
event_index_data = proto.read_event_index()
log.info("apply_config: reading compliance config (SUB 1A)")
compliance_raw = proto.read_compliance_config() # ~2126 bytes (varies ±1-2 by DLE jitter)
log.info("apply_config: reading waveform data (SUB 09)")
waveform_data = proto.read_waveform_data_raw() # 204 bytes
log.info("apply_config: reading trigger config (SUB 2E)")
trigger_data = proto.read_trigger_config() # 26 bytes, this unit's own
# 2. Patch the compliance buffer and build the 2128-byte write payload
compliance_data = _encode_compliance_config(
compliance_raw,
recording_mode=recording_mode,
sample_rate=sample_rate,
record_time=record_time,
histogram_interval_sec=histogram_interval_sec,
trigger_level_geo=trigger_level_geo,
alarm_level_geo=alarm_level_geo,
geo_range=geo_range,
project=project,
client_name=client_name,
operator=operator,
seis_loc=seis_loc,
notes=notes,
)
log.info("apply_config: compliance payload ready (%d bytes)", len(compliance_data))
# 3. Push the full write sequence to the device
self.push_config_raw(event_index_data, compliance_data, trigger_data, waveform_data)
log.info("apply_config: complete")
def set_project_info(
self,
project: Optional[str] = None,
client_name: Optional[str] = None,
operator: Optional[str] = None,
seis_loc: Optional[str] = None,
notes: Optional[str] = None,
) -> None:
"""Backwards-compat shim — delegates to apply_config()."""
self.apply_config(
project=project,
client_name=client_name,
operator=operator,
seis_loc=seis_loc,
notes=notes,
)
# ── Call home config ──────────────────────────────────────────────────────
def get_call_home_config(self) -> CallHomeConfig:
@@ -2127,253 +2006,6 @@ def _extract_project_strings(data: bytes) -> Optional[ProjectInfo]:
)
def _encode_compliance_config(
raw: bytes,
*,
recording_mode: Optional[int] = None,
sample_rate: Optional[int] = None,
record_time: Optional[float] = None,
trigger_level_geo: Optional[float] = None,
alarm_level_geo: Optional[float] = None,
geo_range: Optional[int] = None, # 0x00=Normal 10in/s, 0x01=Sensitive 1.25in/s
histogram_interval_sec: Optional[int] = None,
project: Optional[str] = None,
client_name: Optional[str] = None,
operator: Optional[str] = None,
seis_loc: Optional[str] = None,
notes: Optional[str] = None,
) -> bytes:
"""
Patch a live 2126-byte compliance buffer (read from the device) with any
supplied field values and return the 2128-byte write payload.
Only non-None arguments are modified; everything else is round-tripped verbatim.
Numeric field locations (all anchor-relative or label-relative — immune to
DLE-jitter shifts):
Anchor: b'\\xbe\\x80\\x00\\x00\\x00\\x00' (confirmed stable, both BE11529 and BE18189)
⚠ 2026-10-29: these RAW offsets were measured at 1024 sps, where the escape
before `04` sits between the mode and the anchor. The decoder now reads
the four fields after unescaping (mode -7, rate -6, interval -4, record
time +6), so at any other layout these patch the wrong bytes. Until the
encoder is rewritten on unescaped bytes (#46), a payload whose four fields
do not read back as asked raises ValueError -- see the end of this function.
recording_mode → uint8 at anchor_pos - 8 (raw; right at 1024 sps only)
Values: 0x00=Single Shot, 0x01=Continuous, 0x03=Histogram, 0x04=Histogram+Continuous
NOTE: The byte at anchor_pos - 7 is always 0x10 (a DLE marker regenerated by
device firmware in every E5 response). It must NOT be overwritten during
write — doing so causes anchor drift (+1 per write cycle).
CORRECTION 2026-04-21: previous doc stated anchor-7 for write; empirically
confirmed wrong — writing to anchor-7 shifts the anchor by 1 on every cycle.
sample_rate → uint16 BE at anchor_pos - 6
histogram_interval_sec → uint16 BE at anchor_pos - 4 (seconds; mode-gated to Histogram/Histogram+Continuous)
Valid values: 2, 5, 15, 60, 300, 900 (= 2s, 5s, 15s, 1m, 5m, 15m)
record_time → float32 BE at anchor_pos + 6
Channel block (anchored on b"Tran" with unit-string guard):
geo_range → uint8 at tran_pos + 33 (confirmed 2026-04-20)
0x00 = Normal 10.000 in/s, 0x01 = Sensitive 1.250 in/s
Written to Tran, Vert, Long channel blocks (all three).
adc_scale_factor → float32 BE at tran_pos + 28 (= 6.206053; do NOT write)
trigger_level_geo → float32 BE at tran_pos + 34
"in.\\x00" → unit string at tran_pos + 38 (layout guard)
alarm_level_geo → float32 BE at tran_pos + 42
"/s\\x00\\x00" → unit string at tran_pos + 46 (layout guard)
NOTE: tran_pos+28 (float32 = 6.206053) is the ADC-to-velocity scale factor
(= 1/sensitivity, (in/s)/V — Interface Handbook §4.5: 1.61133 V × 6.206053 = 10.000 in/s).
This is a hardware/firmware constant common to all MiniMate Plus S3 units.
It must NOT be written — do not add it back as a parameter.
String field locations (64-byte slots, label+22 format):
b"Project:" → value at label_pos + 22, max 41 chars + null
b"Client:" → value at label_pos + 22, max 41 chars + null
b"User Name:" → value at label_pos + 22, max 41 chars + null
b"Seis Loc:" → value at label_pos + 22, max 41 chars + null
b"Extended Notes"→ value at label_pos + 22, max 41 chars + null
Returns:
2128-byte write payload: patched 2126-byte buffer + 2-byte footer \\x00\\x00.
(Checksum formula for the footer is unknown; \\x00\\x00 confirmed accepted
by the device in POC test 2026-04-07.)
Raises:
ValueError: if raw is shorter than the minimum needed for the 3-chunk write.
"""
# Total size is nominally ~2126 bytes but varies by ±1-2 bytes depending on
# DLE jitter in the E5 read response (0x10 bytes in the config data cause
# 1-byte expansions per occurrence during DLE stuffing/unstuffing). The
# anchor-based field access and the chunk splitter (fixed chunk1=1027,
# chunk2=1055, chunk3=remainder) both handle variable length correctly.
# Only enforce a minimum — must have at least chunk1+chunk2 bytes of content.
_MIN_COMPLIANCE_LEN = 1027 + 1055 # = 2082
if len(raw) < _MIN_COMPLIANCE_LEN:
raise ValueError(
f"_encode_compliance_config: compliance buffer too short "
f"({len(raw)} bytes, need at least {_MIN_COMPLIANCE_LEN})"
)
if len(raw) not in range(2124, 2132):
log.warning(
"_encode_compliance_config: unusual compliance buffer length %d "
"(expected ~2126); proceeding with anchor-based access",
len(raw),
)
buf = bytearray(raw)
# ── Numeric: recording_mode + sample_rate + record_time (anchor-relative) ──
_ANC = b'\xbe\x80\x00\x00\x00\x00'
_anc = buf.find(_ANC, 0, 150)
# Log anchor position every time so we can detect unexpected shifts due to
# DLE jitter or firmware differences. Expected position is ~15.
if _anc < 0:
log.warning(
"_encode_compliance_config: anchor NOT FOUND in cfg[0:150] "
"(buf len=%d) — all anchor-relative writes will be skipped",
len(buf),
)
else:
log.info(
"_encode_compliance_config: anchor at cfg[%d] buf_len=%d "
"(recording_mode@%d DLE_marker@%d sample_rate@%d:%d "
"histogram_interval@%d:%d record_time@%d:%d)",
_anc, len(buf),
_anc - 8,
_anc - 7,
_anc - 6, _anc - 4,
_anc - 4, _anc - 2,
_anc + 6, _anc + 10,
)
if recording_mode is not None:
if _anc < 8:
log.warning("_encode_compliance_config: anchor not found — cannot write recording_mode")
else:
# Write to anchor-8, same physical position as the E5 read format.
# The byte at anchor-7 is a DLE marker (0x10) that the device firmware
# regenerates in every E5 response — it must NOT be overwritten.
# Writing to anchor-7 causes the device to add an extra byte on the
# next read-back, drifting the anchor by +1 on every write cycle.
# (CLAUDE.md "anchor-7 write" was incorrect — confirmed 2026-04-21)
buf[_anc - 8] = recording_mode & 0xFF
log.debug("_encode_compliance_config: recording_mode=0x%02X -> offset %d",
recording_mode, _anc - 8)
if sample_rate is not None:
if _anc < 6:
log.warning("_encode_compliance_config: anchor not found — cannot write sample_rate")
else:
struct.pack_into(">H", buf, _anc - 6, sample_rate)
log.debug("_encode_compliance_config: sample_rate=%d -> offset %d", sample_rate, _anc - 6)
if histogram_interval_sec is not None:
if _anc < 4:
log.warning("_encode_compliance_config: anchor not found — cannot write histogram_interval")
else:
struct.pack_into(">H", buf, _anc - 4, histogram_interval_sec)
log.debug("_encode_compliance_config: histogram_interval=%ds -> offset %d",
histogram_interval_sec, _anc - 4)
if record_time is not None:
if _anc < 0 or _anc + 10 > len(buf):
log.warning("_encode_compliance_config: anchor not found — cannot write record_time")
else:
struct.pack_into(">f", buf, _anc + 6, record_time)
log.debug("_encode_compliance_config: record_time=%.3f -> offset %d", record_time, _anc + 6)
# ── Numeric: channel block (Tran label + unit-string guard) ───────────────
# NOTE: tran_pos+24 (write format) or tran_pos+28 (E5 read format) is the
# ADC-to-velocity scale factor (6.206053, hardware constant — never written).
# geo_range is written to ALL THREE geo channel blocks (Tran, Vert, Long),
# confirmed from 4-20-26 captures showing the byte at label+29 in each block.
_needs_channel = any(v is not None for v in (trigger_level_geo, alarm_level_geo, geo_range))
if _needs_channel:
_tran = buf.find(b"Tran", 44)
_valid = (
_tran >= 0
and buf[_tran + 4 : _tran + 5] != b"2"
and _tran + 50 <= len(buf)
and buf[_tran + 38 : _tran + 42] == b"in.\x00"
and buf[_tran + 46 : _tran + 50] == b"/s\x00\x00"
)
if not _valid:
log.warning(
"_encode_compliance_config: 'Tran' channel block not found or unit "
"guard failed — trigger/alarm/geo_range will not be written"
)
else:
if trigger_level_geo is not None:
struct.pack_into(">f", buf, _tran + 34, trigger_level_geo)
log.debug("_encode_compliance_config: trigger_level_geo=%.4f -> offset %d", trigger_level_geo, _tran + 34)
if alarm_level_geo is not None:
struct.pack_into(">f", buf, _tran + 42, alarm_level_geo)
log.debug("_encode_compliance_config: alarm_level_geo=%.4f -> offset %d", alarm_level_geo, _tran + 42)
if geo_range is not None:
# Write geo_range to all three geo channel blocks (Tran, Vert, Long).
# Field at label+33 in the E5-format compliance bytes (same in read and write
# since the 2126-byte payload is round-tripped verbatim).
# 0x00 = Normal 10.000 in/s, 0x01 = Sensitive 1.250 in/s.
for _ch_label in (b"Tran", b"Vert", b"Long"):
_ch = buf.find(_ch_label, 44)
if _ch >= 0 and buf[_ch + 4 : _ch + 5] != b"2" and _ch + 34 <= len(buf):
buf[_ch + 33] = geo_range & 0xFF
log.debug(
"_encode_compliance_config: geo_range=0x%02X -> %s+33 offset %d",
geo_range, _ch_label.decode(), _ch + 33,
)
# ── ASCII strings (64-byte slot, value at label_pos+22) ───────────────────
def _set_string(label: bytes, value: Optional[str]) -> None:
if value is None:
return
idx = buf.find(label)
if idx < 0:
log.warning("_encode_compliance_config: label %r not found", label)
return
val_bytes = value.encode("ascii", errors="replace")[:_COMPLIANCE_VALUE_MAX - 1]
padded = val_bytes + b"\x00" * (_COMPLIANCE_VALUE_MAX - len(val_bytes))
buf[idx + _COMPLIANCE_VALUE_OFFSET : idx + _COMPLIANCE_SLOT_SIZE] = padded
log.debug("_encode_compliance_config: %r -> %r", label, value)
_set_string(b"Project:", project)
_set_string(b"Client:", client_name)
_set_string(b"User Name:", operator)
_set_string(b"Seis Loc:", seis_loc)
_set_string(b"Extended Notes", notes)
# ── Read-back check: the payload must decode to what was asked ────────────
# The decoder is the measured layout (every recorded reply); these offsets are
# 1024-sps raw ones. A mode change on BE9441's 10-25 Continuous / 4096 block
# rewrote the byte in front of the mode and read back unchanged. Refuse it
# here, before push_config_raw sends anything.
asked = {"recording_mode": recording_mode, "sample_rate": sample_rate,
"histogram_interval_sec": histogram_interval_sec, "record_time": record_time}
if any(v is not None for v in asked.values()):
before, after = _settings_read_back(raw), _settings_read_back(bytes(buf))
if record_time is not None:
asked["record_time"] = struct.unpack(">f", struct.pack(">f", record_time))[0]
want = {k: (v if v is not None else before[k]) for k, v in asked.items()}
wrong = {k: (after[k], want[k]) for k in asked if after[k] != want[k]}
if wrong:
raise ValueError(
"_encode_compliance_config: the patched block would not read back as asked ("
+ ", ".join(f"{k} reads {got!r}, not {exp!r}" for k, (got, exp) in wrong.items())
+ ") -- refused, nothing built or sent. The encoder's offsets were measured at "
"1024 sps and need rewriting on unescaped bytes (#46)."
)
# 2-byte footer — checksum formula unknown; \x00\x00 confirmed accepted by device
return bytes(buf) + b"\x00\x00"
def _settings_read_back(data: bytes) -> dict:
"""Mode, sample rate, interval and record time as the decoder reads `data`."""
info = DeviceInfo(serial="", firmware_minor=0)
_decode_compliance_config_into(data, info)
cc = info.compliance_config
return {k: getattr(cc, k, None) if cc is not None else None
for k in ("recording_mode", "sample_rate", "histogram_interval_sec", "record_time")}
def _decode_compliance_config_into(data: bytes, info: DeviceInfo) -> None:
-68
View File
@@ -1,68 +0,0 @@
"""
poc_set_project.py — POC test for set_project_info() against a live MiniMate Plus.
Usage:
python poc_set_project.py [--host IP] [--port PORT]
Default target: BE11529 at 63.43.212.232:9034
"""
import argparse
import logging
import sys
logging.basicConfig(
level=logging.DEBUG,
format="%(asctime)s %(levelname)-7s %(name)s %(message)s",
datefmt="%H:%M:%S",
)
log = logging.getLogger("poc_set_project")
from minimateplus import MiniMateClient
from minimateplus.transport import TcpTransport
DEFAULT_HOST = "63.43.212.232"
DEFAULT_PORT = 9034
def main() -> None:
ap = argparse.ArgumentParser(description="POC: write project info to MiniMate Plus")
ap.add_argument("--host", default=DEFAULT_HOST, help="Modem IP address")
ap.add_argument("--port", type=int, default=DEFAULT_PORT, help="TCP port")
ap.add_argument("--project", default="POC Write Test")
ap.add_argument("--client-name", default="Terra-Mechanics Inc.")
ap.add_argument("--operator", default="B. Harrison")
ap.add_argument("--seis-loc", default="Lab Bench - POC")
ap.add_argument("--notes", default="set_project_info POC 2026-04-07")
args = ap.parse_args()
log.info("Connecting to %s:%d", args.host, args.port)
transport = TcpTransport(args.host, port=args.port)
with MiniMateClient(transport=transport, timeout=60.0) as client:
log.info("Performing POLL handshake + identity read …")
info = client.connect()
log.info("Connected: serial=%s firmware=%s", info.serial, info.firmware_version)
log.info("Calling set_project_info() …")
client.set_project_info(
project=args.project,
client_name=args.client_name,
operator=args.operator,
seis_loc=args.seis_loc,
notes=args.notes,
)
log.info("set_project_info() returned — write sequence complete")
log.info("Done. Reconnect Blastware to verify the fields were written.")
if __name__ == "__main__":
try:
main()
except KeyboardInterrupt:
sys.exit(0)
except Exception as exc:
log.exception("Fatal: %s", exc)
sys.exit(1)
+33 -1
View File
@@ -9,7 +9,7 @@ import threading
import time
from typing import Any, Callable, Dict, Optional
from .errors import ConnectFailed, DeviceError, NoAnswer, NotSupported, WrongUnit
from .errors import BadRequest, ConnectFailed, DeviceError, NoAnswer, NotSupported, WrongUnit
from .events import parse_event_id
from .locks import UnitLocks
from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, UnitAddress, UnitInfo,
@@ -17,6 +17,7 @@ from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, Un
from .s3 import Series3Adapter, default_s3_client_factory
from .s4 import (
Series4Session, default_s4_client_factory, s4_call_home_state, s4_change_call_home, s4_change_monitoring,
s4_change_settings,
s4_download_event, s4_identify, s4_list_events, s4_settings, s4_status,
)
from .series import normalise_serial, series_for_serial
@@ -27,6 +28,9 @@ log = logging.getLogger("sfm.device_access")
# reads, a second apart -- not the start/stop window.
_CALL_HOME_VERIFY_TIMEOUT_S = 3.0
_CALL_HOME_VERIFY_INTERVAL_S = 1.0
# A settings read-back is one block read (seconds over cellular): two tries, a second apart.
_SETTINGS_VERIFY_TIMEOUT_S = 2.0
_SETTINGS_VERIFY_INTERVAL_S = 1.0
class DeviceAccess:
@@ -140,6 +144,34 @@ class DeviceAccess:
lambda c, s: s4_change_call_home(c, s, address=address, **kw),
change=True)
def change_settings(self, address: UnitAddress, serial: str, *, changes: dict,
revision: Optional[str], dry_run: bool = False,
caller: str = "api") -> ChangeResult:
"""Change the unit's settings (spec row 10, phase 5). A dry run is the
preview: old -> new per field and a `revision`. A live change needs that
revision; it is audited, identity-checked, sent once, never retried, and
read back. Refused before any I/O: no changes, a live call without a
revision, no audit log."""
serial = normalise_serial(serial)
series_for_serial(serial) # BadRequest (422) before anything else
if not isinstance(changes, dict) or not changes:
raise BadRequest("no settings to change -- nothing sent")
if not dry_run and not revision:
raise BadRequest("preview first: a live change needs the revision from its preview "
"-- nothing sent")
if not dry_run and self._audit is None:
raise NotSupported("no audit log is configured -- SFM refuses to change a unit "
"without one (nothing sent)")
kw = dict(changes=changes, revision=revision, dry_run=dry_run, audit=self._audit,
caller=caller, sleep=self._sleep,
verify_timeout_s=_SETTINGS_VERIFY_TIMEOUT_S,
verify_interval_s=_SETTINGS_VERIFY_INTERVAL_S)
return self._dispatch(
address, serial,
lambda a, s: self._s3.change_settings(a, s, **kw),
lambda c, s: s4_change_settings(c, s, address=address, **kw),
change=True)
def held_serial(self, address: UnitAddress) -> Optional[str]:
"""Serial of the OPEN held Series-4 line at this address, else None. No I/O."""
with self._sessions_guard:
+50 -133
View File
@@ -50,7 +50,7 @@ import tempfile
import threading
import time
from pathlib import Path
from typing import Mapping, Optional
from typing import Any, Dict, Mapping, Optional
# FastAPI / Pydantic
try:
@@ -426,6 +426,7 @@ _SERIAL_AWARE_PATHS = frozenset({
"/device/events", "/device/events/download",
"/device/monitor/start", "/device/monitor/stop",
"/device/call_home/state", "/device/call_home/enable", "/device/call_home/disable",
"/device/settings/change",
})
@@ -1112,145 +1113,61 @@ def device_event_blastware_file(
# ── Write endpoints ───────────────────────────────────────────────────────────
class DeviceConfigBody(BaseModel):
"""
Request body for POST /device/config.
All fields are optional — only supplied (non-null) fields are written to
the device. All other config bytes are round-tripped verbatim.
Recording parameters
--------------------
recording_mode : Recording mode enum. Values: 0=Single Shot, 1=Continuous, 3=Histogram, 4=Histogram+Continuous.
sample_rate : Samples per second. Valid values: 1024, 2048, 4096.
record_time : Record duration in seconds (e.g. 1.0, 2.0, 3.0).
Trigger / alarm thresholds and range (geo channels)
----------------------------------------------------
trigger_level_geo : Trigger threshold in in/s (e.g. 0.5).
alarm_level_geo : Alarm threshold in in/s (e.g. 1.0).
geo_range : Geophone range/sensitivity. 0=Normal 10.000 in/s, 1=Sensitive 1.250 in/s.
Project / operator strings (max 41 ASCII characters each)
----------------------------
project : Project description.
client_name : Client / company name.
operator : Operator / technician name.
seis_loc : Sensor location description.
notes : Extended notes.
"""
# Recording parameters
recording_mode: Optional[int] = None
sample_rate: Optional[int] = None
record_time: Optional[float] = None
histogram_interval_sec: Optional[int] = None # seconds: 2, 5, 15, 60, 300, 900 (mode-gated)
# Threshold parameters / geo range
trigger_level_geo: Optional[float] = None
alarm_level_geo: Optional[float] = None
geo_range: Optional[int] = None # 0=Normal 10.000 in/s, 1=Sensitive 1.250 in/s
# Project / operator strings
project: Optional[str] = None
client_name: Optional[str] = None
operator: Optional[str] = None
seis_loc: Optional[str] = None
notes: Optional[str] = None
_CONFIG_RETIRED = ("retired: change a unit's settings by serial with POST /device/settings/change "
"(audited, previewed, read back)")
@app.post("/device/config")
def device_config(
body: DeviceConfigBody,
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: int = Query(38400, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
serial: Optional[str] = Query(None, description=_SERIAL_CHECK_DOC),
) -> dict:
"""
Read the current device config, apply any supplied changes to the compliance
block, and write the full config back.
Only non-null fields in the JSON body are modified. All other config bytes
are round-tripped verbatim from the device.
Supply either *port* (serial) or *host* (TCP/modem).
Example body (all fields optional — include only what you want to change):
{
"recording_mode": 1,
"sample_rate": 1024,
"record_time": 3.0,
"trigger_level_geo": 0.5,
"alarm_level_geo": 1.0,
"project": "Bridge Inspection 2026",
"client_name": "City of Portland",
"operator": "Brian Harrison",
"seis_loc": "South Abutment",
"notes": "Pre-blast baseline"
}
Returns:
{"status": "ok", "updated_fields": {...}} on success.
Raises:
502 on protocol errors (timeout, bad ack, etc.).
422 if neither port nor host is provided.
"""
changed = body.model_dump(exclude_none=True)
conn_key = _live_cache.make_conn_key(host, tcp_port, port, baud)
log.info("POST /device/config port=%s host=%s fields=%s", port, host, list(changed.keys()))
try:
def _do():
with _build_client(port, baud, host, tcp_port) as client:
info = client.connect()
_require_series3(info.serial, serial)
client.apply_config(
recording_mode=body.recording_mode,
sample_rate=body.sample_rate,
record_time=body.record_time,
histogram_interval_sec=body.histogram_interval_sec,
trigger_level_geo=body.trigger_level_geo,
alarm_level_geo=body.alarm_level_geo,
geo_range=body.geo_range,
project=body.project,
client_name=body.client_name,
operator=body.operator,
seis_loc=body.seis_loc,
notes=body.notes,
)
_run_with_retry(_do, is_tcp=_is_tcp(host))
except HTTPException:
raise
except ProtocolError as exc:
raise HTTPException(status_code=502, detail=f"Protocol error: {exc}") from exc
except OSError as exc:
raise HTTPException(status_code=502, detail=f"Connection error: {exc}") from exc
except ValueError as exc:
raise HTTPException(status_code=422, detail=str(exc)) from exc
except Exception as exc:
raise HTTPException(status_code=500, detail=f"Device error: {exc}") from exc
# Config was written to the device — the cached compliance config is now stale.
conn_key = SFMCache.make_conn_key(host, tcp_port, port, baud)
get_cache().mark_config_dirty(conn_key)
return {
"status": "ok",
"updated_fields": changed,
}
def device_config() -> JSONResponse:
"""Retired (phase 5, 2026-11-03). It wrote a MiniMate's settings through an
encoder #46 found wrong, unaudited, with no read-back, retrying the whole
write on a TCP error. Use POST /device/settings/change."""
return JSONResponse(status_code=410, content={"detail": _CONFIG_RETIRED})
# Keep the old endpoint alive under its old URL for anything already calling it
@app.post("/device/config/project")
def device_config_project(
body: DeviceConfigBody,
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: int = Query(38400, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
def device_config_project() -> JSONResponse:
"""Retired with POST /device/config -- use POST /device/settings/change."""
return JSONResponse(status_code=410, content={"detail": _CONFIG_RETIRED})
class SettingsChangeBody(BaseModel):
"""POST /device/settings/change. `changes` maps field -> new value, using
the field names in GET /device/settings' `detail.editable`. `revision` is the
one a dry run (the preview) returned; a live change without it is refused."""
changes: Dict[str, Any]
revision: Optional[str] = None
@app.post("/device/settings/change")
def device_settings_change(
body: SettingsChangeBody,
serial: str = Query(..., description=_SERIAL_DOC),
host: Optional[str] = Query(None, description="TCP host — modem IP"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
serial: Optional[str] = Query(None, description=_SERIAL_CHECK_DOC),
) -> dict:
"""Deprecated alias for POST /device/config — use that instead."""
return device_config(body=body, port=port, baud=baud, host=host, tcp_port=tcp_port, serial=serial)
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: Optional[int] = Query(None, description="Serial baud rate"),
dry_run: bool = Query(False, description="Preview: old -> new and a revision; send nothing"),
caller: Optional[str] = Query(None, description="Who is asking (recorded in the audit row)"),
):
"""Change a unit's settings by serial, both series (spec row 10, phase 5).
Preview first (`dry_run=true`): it reads the unit and returns, per field, the
value it holds and the value it would get, any warnings, anything that blocks
the change, and a `revision`. Then send the same body live with that
revision: identity read first, refused if the unit is monitoring or its
settings changed since the preview (409), sent once, never retried, read back.
Statuses as /device/monitor/start; a change that went out but was not
confirmed carries `sent` and `audit_id`."""
resp = _change_response(lambda: _device_access().change_settings(
_unit_address(port, baud, host, tcp_port), serial, changes=body.changes,
revision=body.revision, dry_run=dry_run, caller=caller or "api"))
if not dry_run:
try: # a by-host read must not serve stale settings
get_cache().mark_config_dirty(_live_cache.make_conn_key(host, tcp_port, port, baud))
except Exception as exc: # noqa: BLE001 -- the change's answer stands
log.warning("could not mark the cached config dirty: %s", exc)
return resp
# ── Monitoring endpoints ───────────────────────────────────────────────────────
+70
View File
@@ -0,0 +1,70 @@
"""DeviceAccess.change_settings (phase 5): the series-independent entry point --
what it refuses before any I/O, and that it dispatches a change (never retried)."""
from __future__ import annotations
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from device_access_fakes import FakeMiniMateClient, FakeMicromateClient # noqa: E402
from sfm.device_access.access import DeviceAccess # noqa: E402
from sfm.device_access.errors import BadRequest, NotSupported # noqa: E402
from sfm.device_access.models import UnitAddress # noqa: E402
ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None)
class Audit:
def __init__(self):
self.rows = {}
def begin(self, **f):
cid = f"c{len(self.rows) + 1}"
self.rows[cid] = dict(f, outcome="pending")
return cid
def finish(self, cid, **f):
self.rows[cid].update(f)
def _never(*a, **kw):
raise AssertionError("no connection may be opened")
def _access(s3=_never, s4=_never, audit="default"):
return DeviceAccess(s3_client_factory=s3, s4_client_factory=s4, start_reaper=False,
audit=Audit() if audit == "default" else audit, sleep=lambda s: None)
def test_live_change_without_revision_is_refused_before_io():
with pytest.raises(BadRequest, match="preview first"):
_access().change_settings(ADDR, "UM20147", changes={"job_number": 7}, revision=None)
@pytest.mark.parametrize("changes", [{}, None, "job_number=7"])
def test_empty_changes_is_a_bad_request(changes):
with pytest.raises(BadRequest):
_access().change_settings(ADDR, "BE18193", changes=changes, revision="r", dry_run=True)
def test_a_live_change_without_an_audit_log_is_refused():
with pytest.raises(NotSupported, match="audit"):
_access(audit=None).change_settings(ADDR, "BE18193", changes={"job_number": 7}, revision="r")
def test_change_settings_dispatches_by_series_with_change_true(monkeypatch):
access = _access(s3=lambda a, **kw: FakeMiniMateClient(), s4=lambda a, **kw: FakeMicromateClient())
seen = []
real = access._dispatch
def spy(address, serial, s3_op, s4_op, *, change=False):
seen.append((serial, change))
return real(address, serial, s3_op, s4_op, change=change)
monkeypatch.setattr(access, "_dispatch", spy)
r3 = access.change_settings(ADDR, "be18193", changes={"job_number": 7}, revision=None, dry_run=True)
r4 = access.change_settings(ADDR, "UM20147", changes={"job_number": 7}, revision=None, dry_run=True)
assert (r3.series, r4.series) == (3, 4) and r3.outcome == r4.outcome == "dry_run"
assert seen == [("BE18193", True), ("UM20147", True)]
+2 -34
View File
@@ -213,40 +213,8 @@ def test_each_read_returns_the_block_blastware_then_wrote(read, sub, size):
assert block[:-2] == want[:-2] if sub == 0x69 else block == want[:-2]
# -- apply_config writes this unit's own trigger block ---------------------------
class StubProto:
"""Serves BE9441's blocks as read on 2026-10-26; records every write."""
def __init__(self):
self.writes = []
def read_event_index(self):
return _image(0x68)[:-2]
def read_compliance_config(self):
return _image(0x71)[:-2]
def read_waveform_data_raw(self):
return _image(0x69)
def read_trigger_config(self):
return _image(0x82)[:-2]
def __getattr__(self, name):
if name.startswith("write_"):
return lambda *a, **k: self.writes.append((name, a))
raise AttributeError(name)
def test_apply_config_writes_the_units_own_trigger_block():
from minimateplus.client import MiniMateClient
c = MiniMateClient(transport=object())
c._proto = StubProto()
c.apply_config() # nothing changed: a round trip
trig = [a[0] for n, a in c._proto.writes if n == "write_trigger_config"]
assert trig == [_image(0x82)[:-2]]
assert trig[0][5] == 0x01 # BE9441's; the March copy had 0x03
# -- the unit's own trigger block is sent back: tests/test_device_access_s3_settings.py
# (test_s3_trigger_change_sends_the_units_own_blocks), phase 5.
def test_a_bad_block_is_refused_before_the_first_write_goes_out():
+2 -27
View File
@@ -96,30 +96,5 @@ def test_a_reply_without_the_settings_block_reads_as_unknown():
(None, None, None, None)
# The write side (review finding, 2026-10-29). _encode_compliance_config patches
# the RAW bytes at offsets measured at 1024 sps (April 2026), where an escape sits
# between the mode and the anchor. At other rates the mode is one byte later, so
# a mode change rewrote the byte in front of it. A payload that would not read
# back as asked is refused before anything is sent.
from minimateplus.client import _encode_compliance_config # noqa: E402
def _block(i):
return _settings_replies()[i].ljust(2126, b"\x00") # a whole block's length
@pytest.mark.parametrize("i, change", [
(0, {"recording_mode": 0}), # 10-25 Continuous / 4096: mode sits at -7, not -8
(1, {"sample_rate": 4096}), # 10-26 Histogram+Continuous / 2048: escaped mode shifts the rate
])
def test_a_change_that_would_not_read_back_is_refused(i, change):
with pytest.raises(ValueError, match="read back"):
_encode_compliance_config(_block(i), **change)
def test_a_change_that_reads_back_as_asked_is_built():
out = _encode_compliance_config(_block(0), record_time=7.0)
cc = _decode(out)
assert (cc.recording_mode, cc.sample_rate, cc.histogram_interval_sec, cc.record_time) == \
(1, 4096, 5, 7.0)
# The write side moved to the shared settings codec in phase 5 (2026-11-03):
# tests/test_setup_fields.py reproduces every Blastware write byte for byte.
+4 -9
View File
@@ -23,7 +23,7 @@ from fastapi import HTTPException # noqa: E402
import sfm.server as srv # noqa: E402
WRITES = {"delete_all_events", "apply_config", "set_call_home_config", "stop_monitoring"}
WRITES = {"delete_all_events", "set_call_home_config", "stop_monitoring"}
ADDR = dict(port=None, baud=38400, host="10.0.0.9", tcp_port=9034)
@@ -56,9 +56,6 @@ class Unit:
def delete_all_events(self):
self._rec("delete_all_events")
def apply_config(self, **kw):
self._rec("apply_config")
def set_call_home_config(self, **kw):
self._rec("set_call_home_config")
@@ -72,8 +69,6 @@ class Cache:
def _call(route, serial):
if route == "config":
return srv.device_config(body=srv.DeviceConfigBody(), serial=serial, **ADDR)
if route == "erase":
return srv.device_events_erase(serial=serial, **ADDR)
if route == "rescue":
@@ -98,7 +93,7 @@ def unit(monkeypatch):
return make
ROUTES = ["config", "erase", "rescue", "call_home"]
ROUTES = ["erase", "rescue", "call_home"] # /device/config is retired (410)
@pytest.mark.parametrize("route", ROUTES)
@@ -131,8 +126,8 @@ def test_guarded_route_proceeds_for_the_named_series3_unit(unit, route):
def test_the_identity_check_reuses_connects_serial_where_there_is_one(unit):
# speed: config and erase already read the serial in connect(); no extra read
for route in ("config", "erase"):
# speed: erase already reads the serial in connect(); no extra read
for route in ("erase",):
u = unit("BE9441")
_call(route, None)
assert "read_serial" not in u.calls
+153
View File
@@ -0,0 +1,153 @@
"""POST /device/settings/change (phase 5), and the legacy config write retired.
Handlers are called directly, every parameter passed, as in
test_server_device_access.py."""
from __future__ import annotations
import json
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
import micromate.protocol as mm_proto # noqa: E402
import sfm.server as srv # noqa: E402
from device_access_fakes import FakeMicromateClient, schedule_record # noqa: E402
from fastapi import HTTPException # noqa: E402
from sfm.device_access.access import DeviceAccess # noqa: E402
TCP = dict(port=None, baud=None, host="10.0.0.5", tcp_port=9034)
class Audit:
def __init__(self):
self.rows = {}
def begin(self, **f):
cid = f"c{len(self.rows) + 1}"
self.rows[cid] = dict(f, outcome="pending")
return cid
def finish(self, cid, **f):
self.rows[cid].update(f)
class Cache:
def __init__(self):
self.dirty = []
def mark_config_dirty(self, key):
self.dirty.append(key)
@pytest.fixture
def unit(monkeypatch):
def make(fake):
access = DeviceAccess(s4_client_factory=lambda a, **kw: fake, start_reaper=False,
audit=Audit(), sleep=lambda s: None)
monkeypatch.setattr(srv, "_device_access_instance", access)
cache = Cache()
monkeypatch.setattr(srv, "get_cache", lambda: cache)
return cache
return make
def _post(changes, *, revision=None, dry_run=False, serial="UM20147"):
return srv.device_settings_change(body=srv.SettingsChangeBody(changes=changes, revision=revision),
serial=serial, dry_run=dry_run, caller="test", **TCP)
def _body(resp):
return json.loads(resp.body)
def test_route_dry_run_returns_fields_and_revision(unit):
cache = unit(FakeMicromateClient())
resp = _post({"geo_trigger_ips": 0.3}, dry_run=True)
body = _body(resp)
assert resp.status_code == 200 and body["outcome"] == "dry_run"
assert body["plan"]["fields"]["geo_trigger_ips"] == {"label": "Geophone trigger", "old": 0.5, "new": 0.3}
assert len(body["plan"]["revision"]) == 16 and cache.dirty == []
def test_route_verified_change_is_200_and_mismatch_409(unit, monkeypatch):
fake = FakeMicromateClient()
cache = unit(fake)
rev = _body(_post({"geo_trigger_ips": 0.3}, dry_run=True))["plan"]["revision"]
resp = _post({"geo_trigger_ips": 0.3}, revision=rev)
assert resp.status_code == 200 and _body(resp)["state_after"] == "as asked"
assert len(cache.dirty) == 1 # a by-host read must not serve stale settings
# a unit that acks but stores something else reads back "differs": 409
fake2 = FakeMicromateClient()
unit(fake2)
rev = _body(_post({"job_number": 7}, dry_run=True))["plan"]["revision"]
real = fake2.protocol.execute
def wrong(plan):
acks = real(plan)
fake2.setup = fake2.setup[:40] + b"\x00\x08" + fake2.setup[42:]
from micromate.setup_block import with_crc
fake2.setup = with_crc(fake2.setup)
return acks
monkeypatch.setattr(fake2.protocol, "execute", wrong)
resp = _post({"job_number": 7}, revision=rev)
assert resp.status_code == 409 and _body(resp)["verified"] == "mismatch"
def test_route_unconfirmed_carries_sent_and_audit_id(unit, monkeypatch):
fake = FakeMicromateClient()
unit(fake)
rev = _body(_post({"geo_trigger_ips": 0.3}, dry_run=True))["plan"]["revision"]
real = fake.protocol.execute
def then_drop(plan):
acks = real(plan)
fake.run_states = [0x03] # it began calling home before the read-back
return acks
monkeypatch.setattr(fake.protocol, "execute", then_drop)
resp = _post({"geo_trigger_ips": 0.3}, revision=rev)
body = _body(resp)
assert body["sent"] == "acknowledged" and body["audit_id"]
@pytest.mark.parametrize("fake_kw, match", [
(dict(schedule_body=schedule_record(14, 0x02, "other.mmb") + bytes(264)), "other.mmb"),
(dict(active_name="factory.MMB"), "factory setup"),
(dict(run_states=[0x02]), "stop it first"),
])
def test_route_refusal_is_409_with_reason(unit, fake_kw, match):
fake = FakeMicromateClient(**fake_kw)
unit(fake)
rev = "0000000000000000"
if 0x02 not in fake.run_states: # a monitoring unit refuses the preview too
rev = _body(_post({"geo_trigger_ips": 0.3}, dry_run=True))["plan"]["revision"]
with pytest.raises(HTTPException) as e:
_post({"geo_trigger_ips": 0.3}, revision=rev)
assert e.value.status_code == 409 and match in str(e.value.detail)
def test_route_stale_preview_is_409(unit):
unit(FakeMicromateClient())
with pytest.raises(HTTPException) as e:
_post({"geo_trigger_ips": 0.3}, revision="0000000000000000")
assert e.value.status_code == 409 and "preview again" in str(e.value.detail)
def test_route_live_without_revision_is_422(unit):
unit(FakeMicromateClient())
with pytest.raises(HTTPException) as e:
_post({"geo_trigger_ips": 0.3})
assert e.value.status_code == 422 and "preview first" in str(e.value.detail)
@pytest.mark.parametrize("route", ["device_config", "device_config_project"])
def test_legacy_config_routes_are_gone(route, monkeypatch):
monkeypatch.setattr(srv, "_build_client", lambda *a, **kw: pytest.fail("no client may be built"))
resp = getattr(srv, route)()
assert resp.status_code == 410 and "/device/settings/change" in _body(resp)["detail"]
def test_settings_change_is_serial_aware():
assert "/device/settings/change" in srv._SERIAL_AWARE_PATHS
assert srv._device_guard("/device/settings/change", {"serial": "UM20147", "host": "h"}) is None