feat(sfm): POST /device/settings/change; retire the legacy config write

DeviceAccess.change_settings refuses before any I/O a request with no
changes, a live change without its preview's revision, or no audit log,
then dispatches the series' change (never retried).  The route returns
the preview (fields old -> new, warnings, blocked, revision) or the
result (fields old/new/now), statuses as the other changes, and marks
the cached by-host config dirty after a live change.

/device/config and /device/config/project now answer 410 with a pointer.
Deleted with them: MiniMateClient.apply_config / set_project_info and
the raw-offset _encode_compliance_config (#46 found it wrong), the
lab script poc_set_project.py and experiments.py's EXP6, both of which
wrote a live unit through it.  Git keeps them.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-03 21:51:20 -05:00
1 parent 66bb29b9d4
commit e8eabee4a2
10 files changed
+316 -749

No files matched your search

-107
View File
@@ -60,7 +60,6 @@ from minimateplus.framing import build_bw_frame, SESSION_RESET
from minimateplus.client import (
MiniMateClient,
_decode_compliance_config_into,
_encode_compliance_config,
)
from minimateplus.models import DeviceInfo
@@ -462,111 +461,6 @@ def exp_fewer_polls(host: str, port: int) -> tuple[str, str, dict]:
t.disconnect()
# ══════════════════════════════════════════════════════════════════════════════
# EXP6 — Compliance-only write (71×3→72), skip event index + trigger + waveform
# ══════════════════════════════════════════════════════════════════════════════
#
# Blastware's full write sequence: 68→73 | 71×3→72 | 82→83 | 69→74→72
# We want to know: can we write ONLY the compliance block (71×3→72)?
#
# Test procedure:
# 1. Read current compliance config (SUB 1A)
# 2. Patch the "notes" field to a test marker
# 3. Write ONLY 71×3→72 (skip 68, 73, 82, 83, 69, 74, final 72)
# 4. Read back (SUB 1A) and verify the change was written
# 5. Restore original value
#
# If PASS: we can push individual config fields without touching event index,
# trigger config, or waveform data — huge simplification.
# If FAIL: the device needs the full write sequence (may reject partial write).
#
# SAFETY: We restore original data in a finally block. If the restore write
# fails, the device will have the test marker in "notes" — harmless but visible.
_EXP6_MARKER = "[exp6-test]"
def exp_compliance_only(host: str, port: int) -> tuple[str, str, dict]:
"""Write compliance block alone (71×3→72), verify, and restore."""
client, info = connect_client(host, port)
original_raw: Optional[bytes] = None
try:
proto = client._proto
if proto is None:
return "FAIL", "Could not get protocol handle from client", {}
# 1. Read current compliance
print(" Reading current compliance config (SUB 1A)…")
original_raw = proto.read_compliance_config()
print(f" Got {len(original_raw)} bytes of compliance config")
# Find current notes value for display
info_obj = DeviceInfo()
_decode_compliance_config_into(original_raw, info_obj)
cc = info_obj.compliance_config
orig_notes = cc.notes if cc else "(unknown)"
print(f" Current notes field: {orig_notes!r}")
# 2. Build modified payload with test marker in notes
test_notes = _EXP6_MARKER
modified_raw = _encode_compliance_config(
original_raw,
notes=test_notes,
)
print(f" Encoded modified compliance payload ({len(modified_raw)} bytes)")
print(f" Patching notes: {orig_notes!r} → {test_notes!r}")
# 3. Write ONLY the compliance block: 71×3 → 72
print(" Writing compliance ONLY (71×3→72) — skipping 68/73/82/83/69/74…")
proto.write_compliance_config_raw(modified_raw)
print(" Write complete — device acked 71×3→72")
# 4. Read back and verify
print(" Reading back compliance config to verify…")
readback_raw = proto.read_compliance_config()
readback_info = DeviceInfo()
_decode_compliance_config_into(readback_raw, readback_info)
rb_cc = readback_info.compliance_config
readback_notes = rb_cc.notes if rb_cc else "(decode failed)"
print(f" Read-back notes: {readback_notes!r}")
write_worked = (readback_notes == test_notes)
print(f" Write verified: {write_worked}")
details = {
"original_notes": orig_notes,
"written_notes": test_notes,
"readback_notes": readback_notes,
"write_verified": write_worked,
}
if write_worked:
return "PASS", "Compliance-only write works! No event index or trigger writes needed.", details
else:
return "FAIL", f"Write was not reflected in read-back (got {readback_notes!r})", details
except ProtocolError as exc:
return "FAIL", f"Protocol error: {exc}", {}
finally:
# Restore original compliance data regardless of outcome
if original_raw is not None:
print(" Restoring original compliance config…")
try:
proto2 = client._proto
if proto2:
proto2.write_compliance_config_raw(
_encode_compliance_config(original_raw) # no-op patch = verbatim
)
print(" Restore complete")
else:
print(" WARNING: protocol handle gone — could not restore")
except Exception as exc_r:
print(f" WARNING: restore failed: {exc_r}")
client.close()
# ══════════════════════════════════════════════════════════════════════════════
# Registry + main
# ══════════════════════════════════════════════════════════════════════════════
EXPERIMENTS = {
@@ -575,7 +469,6 @@ EXPERIMENTS = {
"no_5a": ("EXP3", exp_no_5a, "Event record (0C) without bulk waveform (5A)"),
"skip_1e": ("EXP4", exp_skip_1e, "0A/0C with cached key — skip initial 1E"),
"fewer_polls": ("EXP5", exp_fewer_polls, "1 POLL before 5A instead of Blastware's 3"),
"compliance_only": ("EXP6", exp_compliance_only, "Compliance-only write (71×3→72), no other blocks"),
}