feat(sfm): POST /device/settings/change; retire the legacy config write

DeviceAccess.change_settings refuses before any I/O a request with no
changes, a live change without its preview's revision, or no audit log,
then dispatches the series' change (never retried).  The route returns
the preview (fields old -> new, warnings, blocked, revision) or the
result (fields old/new/now), statuses as the other changes, and marks
the cached by-host config dirty after a live change.

/device/config and /device/config/project now answer 410 with a pointer.
Deleted with them: MiniMateClient.apply_config / set_project_info and
the raw-offset _encode_compliance_config (#46 found it wrong), the
lab script poc_set_project.py and experiments.py's EXP6, both of which
wrote a live unit through it.  Git keeps them.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-03 21:51:20 -05:00
1 parent 66bb29b9d4
commit e8eabee4a2
10 files changed
+316 -749

No files matched your search

+2 -370
View File
@@ -70,15 +70,8 @@ S3_MONITORING_FLAGS = frozenset({0x10, 0x0B})
# ⚠ RETRACTED 2026-10-27 (#46): a trigger block "hardcoded from 3-11-26 -- no
# read exists, Blastware writes this fixed blob". Blastware reads it first (SUB
# 0x2E), and its byte 5 differs by unit and session (01 / 03 / 04 on record), so
# the copy changed that setting on any unit that differed. apply_config reads
# the unit's own block (MiniMateProtocol.read_trigger_config).
# Compliance ASCII slot format (confirmed from 3-11-26 capture + label search):
# Each label occupies a 64-byte slot.
# Value starts at slot_start + 22, max 42 bytes, null-padded.
_COMPLIANCE_SLOT_SIZE = 64
_COMPLIANCE_VALUE_OFFSET = 22
_COMPLIANCE_VALUE_MAX = _COMPLIANCE_SLOT_SIZE - _COMPLIANCE_VALUE_OFFSET # 42
# the copy changed that setting on any unit that differed. A settings write sends
# the unit's own block back (sfm.device_access.s3 change_settings, phase 5).
# ── MiniMateClient ────────────────────────────────────────────────────────────
@@ -997,120 +990,6 @@ class MiniMateClient:
log.info("push_config_raw: complete")
def apply_config(
self,
*,
# Recording parameters
recording_mode: Optional[int] = None,
sample_rate: Optional[int] = None,
record_time: Optional[float] = None,
histogram_interval_sec: Optional[int] = None,
# Threshold parameters (geo channels, in/s)
trigger_level_geo: Optional[float] = None,
alarm_level_geo: Optional[float] = None,
geo_range: Optional[int] = None, # 0x00=Normal 10in/s, 0x01=Sensitive 1.25in/s
# Project / operator strings
project: Optional[str] = None,
client_name: Optional[str] = None,
operator: Optional[str] = None,
seis_loc: Optional[str] = None,
notes: Optional[str] = None,
) -> None:
"""
Read the current device config, apply any supplied changes to the
compliance block, and write the full config back to the device.
Only non-None arguments are modified; all other bytes are round-tripped
verbatim from the device.
Configurable fields
-------------------
Recording parameters:
recording_mode : int — 0x00=Single Shot, 0x01=Continuous, 0x03=Histogram, 0x04=Histogram+Continuous
sample_rate : int — samples/sec; valid values: 1024, 2048, 4096
record_time : float — record duration in seconds (e.g. 2.0, 3.0)
Trigger/alarm thresholds and range (geo channels):
trigger_level_geo : float — trigger threshold in/s (e.g. 0.5)
alarm_level_geo : float — alarm threshold in/s (e.g. 1.0)
geo_range : int — 0x00=Normal 10.000 in/s, 0x01=Sensitive 1.250 in/s
(written to Tran/Vert/Long channel blocks)
Project / operator strings (max 41 ASCII characters each):
project : str
client_name : str
operator : str
seis_loc : str — sensor location
notes : str — extended notes
Write sequence (confirmed from 3-11-26 BW TX capture):
68→73 | 71×3→72 | 82→83 | 69→74→72
Write payloads:
event_index_data : 88 bytes — read live via SUB 08
compliance_data : ~2128 bytes — read live via SUB 1A (~2126 bytes, varies ±1-2) + \\x00\\x00 footer
trigger_data : 26 bytes — read live via SUB 2E (was hard-coded; #46)
waveform_data : 204 bytes — read live via SUB 09
Raises:
RuntimeError: if not connected.
ProtocolError: if any read or write step fails.
ValueError: if compliance buffer is shorter than the 2082-byte write minimum.
"""
proto = self._require_proto()
# 1. Read current payloads from the device
log.info("apply_config: reading event index (SUB 08)")
event_index_data = proto.read_event_index()
log.info("apply_config: reading compliance config (SUB 1A)")
compliance_raw = proto.read_compliance_config() # ~2126 bytes (varies ±1-2 by DLE jitter)
log.info("apply_config: reading waveform data (SUB 09)")
waveform_data = proto.read_waveform_data_raw() # 204 bytes
log.info("apply_config: reading trigger config (SUB 2E)")
trigger_data = proto.read_trigger_config() # 26 bytes, this unit's own
# 2. Patch the compliance buffer and build the 2128-byte write payload
compliance_data = _encode_compliance_config(
compliance_raw,
recording_mode=recording_mode,
sample_rate=sample_rate,
record_time=record_time,
histogram_interval_sec=histogram_interval_sec,
trigger_level_geo=trigger_level_geo,
alarm_level_geo=alarm_level_geo,
geo_range=geo_range,
project=project,
client_name=client_name,
operator=operator,
seis_loc=seis_loc,
notes=notes,
)
log.info("apply_config: compliance payload ready (%d bytes)", len(compliance_data))
# 3. Push the full write sequence to the device
self.push_config_raw(event_index_data, compliance_data, trigger_data, waveform_data)
log.info("apply_config: complete")
def set_project_info(
self,
project: Optional[str] = None,
client_name: Optional[str] = None,
operator: Optional[str] = None,
seis_loc: Optional[str] = None,
notes: Optional[str] = None,
) -> None:
"""Backwards-compat shim — delegates to apply_config()."""
self.apply_config(
project=project,
client_name=client_name,
operator=operator,
seis_loc=seis_loc,
notes=notes,
)
# ── Call home config ──────────────────────────────────────────────────────
def get_call_home_config(self) -> CallHomeConfig:
@@ -2127,253 +2006,6 @@ def _extract_project_strings(data: bytes) -> Optional[ProjectInfo]:
)
def _encode_compliance_config(
raw: bytes,
*,
recording_mode: Optional[int] = None,
sample_rate: Optional[int] = None,
record_time: Optional[float] = None,
trigger_level_geo: Optional[float] = None,
alarm_level_geo: Optional[float] = None,
geo_range: Optional[int] = None, # 0x00=Normal 10in/s, 0x01=Sensitive 1.25in/s
histogram_interval_sec: Optional[int] = None,
project: Optional[str] = None,
client_name: Optional[str] = None,
operator: Optional[str] = None,
seis_loc: Optional[str] = None,
notes: Optional[str] = None,
) -> bytes:
"""
Patch a live 2126-byte compliance buffer (read from the device) with any
supplied field values and return the 2128-byte write payload.
Only non-None arguments are modified; everything else is round-tripped verbatim.
Numeric field locations (all anchor-relative or label-relative — immune to
DLE-jitter shifts):
Anchor: b'\\xbe\\x80\\x00\\x00\\x00\\x00' (confirmed stable, both BE11529 and BE18189)
⚠ 2026-10-29: these RAW offsets were measured at 1024 sps, where the escape
before `04` sits between the mode and the anchor. The decoder now reads
the four fields after unescaping (mode -7, rate -6, interval -4, record
time +6), so at any other layout these patch the wrong bytes. Until the
encoder is rewritten on unescaped bytes (#46), a payload whose four fields
do not read back as asked raises ValueError -- see the end of this function.
recording_mode → uint8 at anchor_pos - 8 (raw; right at 1024 sps only)
Values: 0x00=Single Shot, 0x01=Continuous, 0x03=Histogram, 0x04=Histogram+Continuous
NOTE: The byte at anchor_pos - 7 is always 0x10 (a DLE marker regenerated by
device firmware in every E5 response). It must NOT be overwritten during
write — doing so causes anchor drift (+1 per write cycle).
CORRECTION 2026-04-21: previous doc stated anchor-7 for write; empirically
confirmed wrong — writing to anchor-7 shifts the anchor by 1 on every cycle.
sample_rate → uint16 BE at anchor_pos - 6
histogram_interval_sec → uint16 BE at anchor_pos - 4 (seconds; mode-gated to Histogram/Histogram+Continuous)
Valid values: 2, 5, 15, 60, 300, 900 (= 2s, 5s, 15s, 1m, 5m, 15m)
record_time → float32 BE at anchor_pos + 6
Channel block (anchored on b"Tran" with unit-string guard):
geo_range → uint8 at tran_pos + 33 (confirmed 2026-04-20)
0x00 = Normal 10.000 in/s, 0x01 = Sensitive 1.250 in/s
Written to Tran, Vert, Long channel blocks (all three).
adc_scale_factor → float32 BE at tran_pos + 28 (= 6.206053; do NOT write)
trigger_level_geo → float32 BE at tran_pos + 34
"in.\\x00" → unit string at tran_pos + 38 (layout guard)
alarm_level_geo → float32 BE at tran_pos + 42
"/s\\x00\\x00" → unit string at tran_pos + 46 (layout guard)
NOTE: tran_pos+28 (float32 = 6.206053) is the ADC-to-velocity scale factor
(= 1/sensitivity, (in/s)/V — Interface Handbook §4.5: 1.61133 V × 6.206053 = 10.000 in/s).
This is a hardware/firmware constant common to all MiniMate Plus S3 units.
It must NOT be written — do not add it back as a parameter.
String field locations (64-byte slots, label+22 format):
b"Project:" → value at label_pos + 22, max 41 chars + null
b"Client:" → value at label_pos + 22, max 41 chars + null
b"User Name:" → value at label_pos + 22, max 41 chars + null
b"Seis Loc:" → value at label_pos + 22, max 41 chars + null
b"Extended Notes"→ value at label_pos + 22, max 41 chars + null
Returns:
2128-byte write payload: patched 2126-byte buffer + 2-byte footer \\x00\\x00.
(Checksum formula for the footer is unknown; \\x00\\x00 confirmed accepted
by the device in POC test 2026-04-07.)
Raises:
ValueError: if raw is shorter than the minimum needed for the 3-chunk write.
"""
# Total size is nominally ~2126 bytes but varies by ±1-2 bytes depending on
# DLE jitter in the E5 read response (0x10 bytes in the config data cause
# 1-byte expansions per occurrence during DLE stuffing/unstuffing). The
# anchor-based field access and the chunk splitter (fixed chunk1=1027,
# chunk2=1055, chunk3=remainder) both handle variable length correctly.
# Only enforce a minimum — must have at least chunk1+chunk2 bytes of content.
_MIN_COMPLIANCE_LEN = 1027 + 1055 # = 2082
if len(raw) < _MIN_COMPLIANCE_LEN:
raise ValueError(
f"_encode_compliance_config: compliance buffer too short "
f"({len(raw)} bytes, need at least {_MIN_COMPLIANCE_LEN})"
)
if len(raw) not in range(2124, 2132):
log.warning(
"_encode_compliance_config: unusual compliance buffer length %d "
"(expected ~2126); proceeding with anchor-based access",
len(raw),
)
buf = bytearray(raw)
# ── Numeric: recording_mode + sample_rate + record_time (anchor-relative) ──
_ANC = b'\xbe\x80\x00\x00\x00\x00'
_anc = buf.find(_ANC, 0, 150)
# Log anchor position every time so we can detect unexpected shifts due to
# DLE jitter or firmware differences. Expected position is ~15.
if _anc < 0:
log.warning(
"_encode_compliance_config: anchor NOT FOUND in cfg[0:150] "
"(buf len=%d) — all anchor-relative writes will be skipped",
len(buf),
)
else:
log.info(
"_encode_compliance_config: anchor at cfg[%d] buf_len=%d "
"(recording_mode@%d DLE_marker@%d sample_rate@%d:%d "
"histogram_interval@%d:%d record_time@%d:%d)",
_anc, len(buf),
_anc - 8,
_anc - 7,
_anc - 6, _anc - 4,
_anc - 4, _anc - 2,
_anc + 6, _anc + 10,
)
if recording_mode is not None:
if _anc < 8:
log.warning("_encode_compliance_config: anchor not found — cannot write recording_mode")
else:
# Write to anchor-8, same physical position as the E5 read format.
# The byte at anchor-7 is a DLE marker (0x10) that the device firmware
# regenerates in every E5 response — it must NOT be overwritten.
# Writing to anchor-7 causes the device to add an extra byte on the
# next read-back, drifting the anchor by +1 on every write cycle.
# (CLAUDE.md "anchor-7 write" was incorrect — confirmed 2026-04-21)
buf[_anc - 8] = recording_mode & 0xFF
log.debug("_encode_compliance_config: recording_mode=0x%02X -> offset %d",
recording_mode, _anc - 8)
if sample_rate is not None:
if _anc < 6:
log.warning("_encode_compliance_config: anchor not found — cannot write sample_rate")
else:
struct.pack_into(">H", buf, _anc - 6, sample_rate)
log.debug("_encode_compliance_config: sample_rate=%d -> offset %d", sample_rate, _anc - 6)
if histogram_interval_sec is not None:
if _anc < 4:
log.warning("_encode_compliance_config: anchor not found — cannot write histogram_interval")
else:
struct.pack_into(">H", buf, _anc - 4, histogram_interval_sec)
log.debug("_encode_compliance_config: histogram_interval=%ds -> offset %d",
histogram_interval_sec, _anc - 4)
if record_time is not None:
if _anc < 0 or _anc + 10 > len(buf):
log.warning("_encode_compliance_config: anchor not found — cannot write record_time")
else:
struct.pack_into(">f", buf, _anc + 6, record_time)
log.debug("_encode_compliance_config: record_time=%.3f -> offset %d", record_time, _anc + 6)
# ── Numeric: channel block (Tran label + unit-string guard) ───────────────
# NOTE: tran_pos+24 (write format) or tran_pos+28 (E5 read format) is the
# ADC-to-velocity scale factor (6.206053, hardware constant — never written).
# geo_range is written to ALL THREE geo channel blocks (Tran, Vert, Long),
# confirmed from 4-20-26 captures showing the byte at label+29 in each block.
_needs_channel = any(v is not None for v in (trigger_level_geo, alarm_level_geo, geo_range))
if _needs_channel:
_tran = buf.find(b"Tran", 44)
_valid = (
_tran >= 0
and buf[_tran + 4 : _tran + 5] != b"2"
and _tran + 50 <= len(buf)
and buf[_tran + 38 : _tran + 42] == b"in.\x00"
and buf[_tran + 46 : _tran + 50] == b"/s\x00\x00"
)
if not _valid:
log.warning(
"_encode_compliance_config: 'Tran' channel block not found or unit "
"guard failed — trigger/alarm/geo_range will not be written"
)
else:
if trigger_level_geo is not None:
struct.pack_into(">f", buf, _tran + 34, trigger_level_geo)
log.debug("_encode_compliance_config: trigger_level_geo=%.4f -> offset %d", trigger_level_geo, _tran + 34)
if alarm_level_geo is not None:
struct.pack_into(">f", buf, _tran + 42, alarm_level_geo)
log.debug("_encode_compliance_config: alarm_level_geo=%.4f -> offset %d", alarm_level_geo, _tran + 42)
if geo_range is not None:
# Write geo_range to all three geo channel blocks (Tran, Vert, Long).
# Field at label+33 in the E5-format compliance bytes (same in read and write
# since the 2126-byte payload is round-tripped verbatim).
# 0x00 = Normal 10.000 in/s, 0x01 = Sensitive 1.250 in/s.
for _ch_label in (b"Tran", b"Vert", b"Long"):
_ch = buf.find(_ch_label, 44)
if _ch >= 0 and buf[_ch + 4 : _ch + 5] != b"2" and _ch + 34 <= len(buf):
buf[_ch + 33] = geo_range & 0xFF
log.debug(
"_encode_compliance_config: geo_range=0x%02X -> %s+33 offset %d",
geo_range, _ch_label.decode(), _ch + 33,
)
# ── ASCII strings (64-byte slot, value at label_pos+22) ───────────────────
def _set_string(label: bytes, value: Optional[str]) -> None:
if value is None:
return
idx = buf.find(label)
if idx < 0:
log.warning("_encode_compliance_config: label %r not found", label)
return
val_bytes = value.encode("ascii", errors="replace")[:_COMPLIANCE_VALUE_MAX - 1]
padded = val_bytes + b"\x00" * (_COMPLIANCE_VALUE_MAX - len(val_bytes))
buf[idx + _COMPLIANCE_VALUE_OFFSET : idx + _COMPLIANCE_SLOT_SIZE] = padded
log.debug("_encode_compliance_config: %r -> %r", label, value)
_set_string(b"Project:", project)
_set_string(b"Client:", client_name)
_set_string(b"User Name:", operator)
_set_string(b"Seis Loc:", seis_loc)
_set_string(b"Extended Notes", notes)
# ── Read-back check: the payload must decode to what was asked ────────────
# The decoder is the measured layout (every recorded reply); these offsets are
# 1024-sps raw ones. A mode change on BE9441's 10-25 Continuous / 4096 block
# rewrote the byte in front of the mode and read back unchanged. Refuse it
# here, before push_config_raw sends anything.
asked = {"recording_mode": recording_mode, "sample_rate": sample_rate,
"histogram_interval_sec": histogram_interval_sec, "record_time": record_time}
if any(v is not None for v in asked.values()):
before, after = _settings_read_back(raw), _settings_read_back(bytes(buf))
if record_time is not None:
asked["record_time"] = struct.unpack(">f", struct.pack(">f", record_time))[0]
want = {k: (v if v is not None else before[k]) for k, v in asked.items()}
wrong = {k: (after[k], want[k]) for k in asked if after[k] != want[k]}
if wrong:
raise ValueError(
"_encode_compliance_config: the patched block would not read back as asked ("
+ ", ".join(f"{k} reads {got!r}, not {exp!r}" for k, (got, exp) in wrong.items())
+ ") -- refused, nothing built or sent. The encoder's offsets were measured at "
"1024 sps and need rewriting on unescaped bytes (#46)."
)
# 2-byte footer — checksum formula unknown; \x00\x00 confirmed accepted by device
return bytes(buf) + b"\x00\x00"
def _settings_read_back(data: bytes) -> dict:
"""Mode, sample rate, interval and record time as the decoder reads `data`."""
info = DeviceInfo(serial="", firmware_minor=0)
_decode_compliance_config_into(data, info)
cc = info.compliance_config
return {k: getattr(cc, k, None) if cc is not None else None
for k in ("recording_mode", "sample_rate", "histogram_interval_sec", "record_time")}