feat(sfm): POST /device/settings/change; retire the legacy config write

DeviceAccess.change_settings refuses before any I/O a request with no
changes, a live change without its preview's revision, or no audit log,
then dispatches the series' change (never retried).  The route returns
the preview (fields old -> new, warnings, blocked, revision) or the
result (fields old/new/now), statuses as the other changes, and marks
the cached by-host config dirty after a live change.

/device/config and /device/config/project now answer 410 with a pointer.
Deleted with them: MiniMateClient.apply_config / set_project_info and
the raw-offset _encode_compliance_config (#46 found it wrong), the
lab script poc_set_project.py and experiments.py's EXP6, both of which
wrote a live unit through it.  Git keeps them.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-03 21:51:20 -05:00
1 parent 66bb29b9d4
commit e8eabee4a2
10 files changed
+316 -749

No files matched your search

+50 -133
View File
@@ -50,7 +50,7 @@ import tempfile
import threading
import time
from pathlib import Path
from typing import Mapping, Optional
from typing import Any, Dict, Mapping, Optional
# FastAPI / Pydantic
try:
@@ -426,6 +426,7 @@ _SERIAL_AWARE_PATHS = frozenset({
"/device/events", "/device/events/download",
"/device/monitor/start", "/device/monitor/stop",
"/device/call_home/state", "/device/call_home/enable", "/device/call_home/disable",
"/device/settings/change",
})
@@ -1112,145 +1113,61 @@ def device_event_blastware_file(
# ── Write endpoints ───────────────────────────────────────────────────────────
class DeviceConfigBody(BaseModel):
"""
Request body for POST /device/config.
All fields are optional — only supplied (non-null) fields are written to
the device. All other config bytes are round-tripped verbatim.
Recording parameters
--------------------
recording_mode : Recording mode enum. Values: 0=Single Shot, 1=Continuous, 3=Histogram, 4=Histogram+Continuous.
sample_rate : Samples per second. Valid values: 1024, 2048, 4096.
record_time : Record duration in seconds (e.g. 1.0, 2.0, 3.0).
Trigger / alarm thresholds and range (geo channels)
----------------------------------------------------
trigger_level_geo : Trigger threshold in in/s (e.g. 0.5).
alarm_level_geo : Alarm threshold in in/s (e.g. 1.0).
geo_range : Geophone range/sensitivity. 0=Normal 10.000 in/s, 1=Sensitive 1.250 in/s.
Project / operator strings (max 41 ASCII characters each)
----------------------------
project : Project description.
client_name : Client / company name.
operator : Operator / technician name.
seis_loc : Sensor location description.
notes : Extended notes.
"""
# Recording parameters
recording_mode: Optional[int] = None
sample_rate: Optional[int] = None
record_time: Optional[float] = None
histogram_interval_sec: Optional[int] = None # seconds: 2, 5, 15, 60, 300, 900 (mode-gated)
# Threshold parameters / geo range
trigger_level_geo: Optional[float] = None
alarm_level_geo: Optional[float] = None
geo_range: Optional[int] = None # 0=Normal 10.000 in/s, 1=Sensitive 1.250 in/s
# Project / operator strings
project: Optional[str] = None
client_name: Optional[str] = None
operator: Optional[str] = None
seis_loc: Optional[str] = None
notes: Optional[str] = None
_CONFIG_RETIRED = ("retired: change a unit's settings by serial with POST /device/settings/change "
"(audited, previewed, read back)")
@app.post("/device/config")
def device_config(
body: DeviceConfigBody,
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: int = Query(38400, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
serial: Optional[str] = Query(None, description=_SERIAL_CHECK_DOC),
) -> dict:
"""
Read the current device config, apply any supplied changes to the compliance
block, and write the full config back.
Only non-null fields in the JSON body are modified. All other config bytes
are round-tripped verbatim from the device.
Supply either *port* (serial) or *host* (TCP/modem).
Example body (all fields optional — include only what you want to change):
{
"recording_mode": 1,
"sample_rate": 1024,
"record_time": 3.0,
"trigger_level_geo": 0.5,
"alarm_level_geo": 1.0,
"project": "Bridge Inspection 2026",
"client_name": "City of Portland",
"operator": "Brian Harrison",
"seis_loc": "South Abutment",
"notes": "Pre-blast baseline"
}
Returns:
{"status": "ok", "updated_fields": {...}} on success.
Raises:
502 on protocol errors (timeout, bad ack, etc.).
422 if neither port nor host is provided.
"""
changed = body.model_dump(exclude_none=True)
conn_key = _live_cache.make_conn_key(host, tcp_port, port, baud)
log.info("POST /device/config port=%s host=%s fields=%s", port, host, list(changed.keys()))
try:
def _do():
with _build_client(port, baud, host, tcp_port) as client:
info = client.connect()
_require_series3(info.serial, serial)
client.apply_config(
recording_mode=body.recording_mode,
sample_rate=body.sample_rate,
record_time=body.record_time,
histogram_interval_sec=body.histogram_interval_sec,
trigger_level_geo=body.trigger_level_geo,
alarm_level_geo=body.alarm_level_geo,
geo_range=body.geo_range,
project=body.project,
client_name=body.client_name,
operator=body.operator,
seis_loc=body.seis_loc,
notes=body.notes,
)
_run_with_retry(_do, is_tcp=_is_tcp(host))
except HTTPException:
raise
except ProtocolError as exc:
raise HTTPException(status_code=502, detail=f"Protocol error: {exc}") from exc
except OSError as exc:
raise HTTPException(status_code=502, detail=f"Connection error: {exc}") from exc
except ValueError as exc:
raise HTTPException(status_code=422, detail=str(exc)) from exc
except Exception as exc:
raise HTTPException(status_code=500, detail=f"Device error: {exc}") from exc
# Config was written to the device — the cached compliance config is now stale.
conn_key = SFMCache.make_conn_key(host, tcp_port, port, baud)
get_cache().mark_config_dirty(conn_key)
return {
"status": "ok",
"updated_fields": changed,
}
def device_config() -> JSONResponse:
"""Retired (phase 5, 2026-11-03). It wrote a MiniMate's settings through an
encoder #46 found wrong, unaudited, with no read-back, retrying the whole
write on a TCP error. Use POST /device/settings/change."""
return JSONResponse(status_code=410, content={"detail": _CONFIG_RETIRED})
# Keep the old endpoint alive under its old URL for anything already calling it
@app.post("/device/config/project")
def device_config_project(
body: DeviceConfigBody,
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: int = Query(38400, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
def device_config_project() -> JSONResponse:
"""Retired with POST /device/config -- use POST /device/settings/change."""
return JSONResponse(status_code=410, content={"detail": _CONFIG_RETIRED})
class SettingsChangeBody(BaseModel):
"""POST /device/settings/change. `changes` maps field -> new value, using
the field names in GET /device/settings' `detail.editable`. `revision` is the
one a dry run (the preview) returned; a live change without it is refused."""
changes: Dict[str, Any]
revision: Optional[str] = None
@app.post("/device/settings/change")
def device_settings_change(
body: SettingsChangeBody,
serial: str = Query(..., description=_SERIAL_DOC),
host: Optional[str] = Query(None, description="TCP host — modem IP"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
serial: Optional[str] = Query(None, description=_SERIAL_CHECK_DOC),
) -> dict:
"""Deprecated alias for POST /device/config — use that instead."""
return device_config(body=body, port=port, baud=baud, host=host, tcp_port=tcp_port, serial=serial)
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: Optional[int] = Query(None, description="Serial baud rate"),
dry_run: bool = Query(False, description="Preview: old -> new and a revision; send nothing"),
caller: Optional[str] = Query(None, description="Who is asking (recorded in the audit row)"),
):
"""Change a unit's settings by serial, both series (spec row 10, phase 5).
Preview first (`dry_run=true`): it reads the unit and returns, per field, the
value it holds and the value it would get, any warnings, anything that blocks
the change, and a `revision`. Then send the same body live with that
revision: identity read first, refused if the unit is monitoring or its
settings changed since the preview (409), sent once, never retried, read back.
Statuses as /device/monitor/start; a change that went out but was not
confirmed carries `sent` and `audit_id`."""
resp = _change_response(lambda: _device_access().change_settings(
_unit_address(port, baud, host, tcp_port), serial, changes=body.changes,
revision=body.revision, dry_run=dry_run, caller=caller or "api"))
if not dry_run:
try: # a by-host read must not serve stale settings
get_cache().mark_config_dirty(_live_cache.make_conn_key(host, tcp_port, port, baud))
except Exception as exc: # noqa: BLE001 -- the change's answer stands
log.warning("could not mark the cached config dirty: %s", exc)
return resp
# ── Monitoring endpoints ───────────────────────────────────────────────────────