fix(sfm): a MiniMate download stores what its own file says, at the range it was recorded at (#17)
With the decode checker's fixes merged (histogram vector sum625bc39, mic psi5644dbd, the file's geophone range4844135), the event file reads everything Blastware reports. So a live download's row and samples are now the file's: peaks, vector sum, mic -- and the geophone range from the file's own setup block, the setting when the event was recorded. The live 1A is the unit's setting now, which may have changed since; it is the fallback only when the file's range does not read. Measured: K557J1KB.RQ0W (Sensitive waveform) downloaded with its settings unread -- e.g. while monitoring -- stores 0.019 / 0.055 / 0.019 and PVS 0.061, Blastware's report; its .h5 read 0.155 / 0.44 (8x) before. M010HR6K.OA0H (Sensitive histogram) likewise. K441LTON.900 (Normal) stores Blastware's values whatever the unit's current settings say, and its mic is 5.80e-4 psi (Blastware: 106.0 dB(L)). The unit's 0C summary stays the download check, and fills in the channel peaks and vector sum only when the file's range does not read (never seen in DL2) and the unit is not confirmed Normal -- the impossible-vector-sum guard kept there. The mic is the file's always. Closes the range part of open finding #17. Store consequence: new live downloads only; no backfill, no migration. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
d0c14aaec8
commit
f98c4ff129
4 files changed
+150
-77
No files matched your search
@@ -228,9 +228,9 @@ Read this first when picking the project back up.
|
||||
audit `sent: null` (#15), and page polish.
|
||||
**Batch 1 fixed (2026-10-29):** #1 (`b320a53`, settings read after unescaping:
|
||||
mode −7, rate −6, interval −4, record time +6), #9 (`ce441a0`, one reconnect for
|
||||
the read-back), #8 (`9492e49`, downloads stored through `save_imported_bw` with
|
||||
the unit's mic overlaid, its peaks/vector sum too unless Normal range is confirmed
|
||||
-- since 2026-10-31, after the checker's histogram-PVS fix -- and its range passed). #2 came with the
|
||||
the read-back), #8 (`9492e49`, downloads stored through `save_imported_bw`; since
|
||||
2026-11-02 everything comes from the file -- peaks, vector sum, mic and the range
|
||||
it was recorded at -- and the unit's 0C summary is only the download check). #2 came with the
|
||||
`dev` merge. **#15 retracted** -- `sent` NULL is "unknown", by design.
|
||||
Final review fixes: `dbd8a91` (wake before the reconnect's identity read),
|
||||
`3a1d34a` ("already stored" by Blastware name too), `a72d3a9` (the 1A write
|
||||
|
||||
@@ -685,12 +685,15 @@ a short plan; #14 waits for the line-hold decision above.
|
||||
7. `/db/events` 500 "database is locked" on the first page load against a new DB.
|
||||
8. ✅ **Fixed `9492e49`**, plus `3a1d34a` ("already stored" also matches the Blastware
|
||||
name: a histogram's row sits a second off its 0C time). The download carries the assembled Blastware file and is
|
||||
stored through `save_imported_bw` (`source.kind` "sfm-live"), and its range scales
|
||||
the samples. The unit's 0C mic is overlaid (the file reads it as 0). Its channel
|
||||
peaks and vector sum were overlaid too until 2026-10-31; since the checker's
|
||||
histogram-PVS fix (625bc39, merged `6945009`) the file's are taken when the unit
|
||||
confirms Normal range, and the unit's stand for Sensitive or an unread range (the
|
||||
file reader assumes Normal: 8x off). The label came with #41 (`a1d2b61`).
|
||||
stored through `save_imported_bw` (`source.kind` "sfm-live"). Since 2026-11-02
|
||||
(after the checker's fixes for the histogram vector sum 625bc39, the mic psi
|
||||
5644dbd and the file's geophone range 4844135) the row and samples are the
|
||||
file's: peaks, vector sum, mic, and the range the event was recorded at (the live
|
||||
1A is the unit's setting *now*, a fallback only when the file's range does not
|
||||
read). The unit's 0C summary is the download check, and fills in peaks only when
|
||||
the file's range does not read and the unit is not confirmed Normal. Until then
|
||||
the unit's 0C values were overlaid (`9492e49`, narrowed `0a87d85`). The label
|
||||
came with #41 (`a1d2b61`).
|
||||
**S3 downloads are stored from the live waveform decoder** (`store.save`), not
|
||||
the file reader that Series 4 uses (`save_imported_idf`): a histogram gets no
|
||||
samples and is labelled Waveform. Fix: store S3 downloads through the
|
||||
@@ -716,12 +719,13 @@ a short plan; #14 waits for the line-hold decision above.
|
||||
ring instead of its ack is exactly unknown, and the row's `error` says it was sent.
|
||||
16. Page: a 504 on a unit THOR holds should say "connected, but no reply --
|
||||
another program may be holding this unit's line".
|
||||
17. **Found by the Batch 1 review (open):** a MiniMate downloaded *while monitoring*
|
||||
answers 1A with its device-info block, so no range is read and the stored
|
||||
`.h5` samples assume Normal -- 8x off on a sensitive-range unit (the row's
|
||||
peaks are the unit's, overlaid). Pre-existing on the old path too. The same
|
||||
reply decodes a setup name of `:S338.17`. Live S3 downloads also no longer
|
||||
keep the `.a5.pkl` wire record.
|
||||
17. ✅ **Range part fixed 2026-11-02:** a MiniMate downloaded *while monitoring*
|
||||
answers 1A with its device-info block, so no range was read and the stored
|
||||
`.h5` samples assumed Normal -- 8x off on a sensitive-range unit. The range now
|
||||
comes from the event file itself (measured: K557J1KB.RQ0W stores 0.019 / 0.055 /
|
||||
0.019, Blastware's report, with the settings unread). Still open: the same reply
|
||||
decodes a setup name of `:S338.17`, and live S3 downloads no longer keep the
|
||||
`.a5.pkl` wire record.
|
||||
- **Same-second collisions (SDM).** Two events of one unit in the same second collide on (serial, timestamp) — a DB-wide dedup property, not 1b's.
|
||||
- **423 without `Retry-After` (1c).** Add `Retry-After` to the 423 a request gets while a download holds the unit.
|
||||
- **A lost `0C` during a Series-3 list (1c).** The strict walk raises on a lost `0A`
|
||||
|
||||
+39
-29
@@ -66,36 +66,41 @@ def _already_stored(dl: DownloadedEvent, row: dict) -> EventDownload:
|
||||
)
|
||||
|
||||
|
||||
def _overlay_s3_record(ev: Any, unit_peaks: Any, geo_range: Any) -> None:
|
||||
"""The unit's own 0C values over the file's, where the file's are not yet right.
|
||||
def _file_geo_range(bw_bytes: bytes) -> Any:
|
||||
"""The geophone range a Blastware file was recorded at (0 Normal, 1 Sensitive),
|
||||
or None when it does not read -- or the file does not decode at all."""
|
||||
from minimateplus import event_file_io
|
||||
try:
|
||||
return event_file_io.decode_blastware_bytes(bw_bytes).geo_range
|
||||
except Exception: # noqa: BLE001 -- the store reports it
|
||||
return None
|
||||
|
||||
* Mic: always the unit's -- the file reads it as 0 (its psi conversion is an
|
||||
open checker finding).
|
||||
* Channel peaks and vector sum: the file's when the unit's settings confirm
|
||||
Normal range (`geo_range` 0). The file reads them as the unit stored them
|
||||
-- K441LTON.900: 0.200 / 0.385 / 0.255 and 0.385, as Blastware's report,
|
||||
since the decode checker's fix (625bc39, 2026-10-31) -- while the 0C summary
|
||||
is read at fixed offsets and can shift (BE9441 read 0 and -0.0 for vector
|
||||
sums, bench #4). But the file reader computes every peak as if the range
|
||||
were Normal, so a Sensitive unit's come out 8x off (the checker's 33
|
||||
waveforms): for Sensitive, or a range not read (a monitoring unit's 1A
|
||||
carries no settings), the unit's own peaks stand, as before -- a vector
|
||||
sum below the largest channel peak is impossible and is not kept.
|
||||
|
||||
The 0C peaks remain the download *check* (verify_s3_download) either way.
|
||||
def _overlay_s3_record(ev: Any, unit_peaks: Any, unit_range: Any) -> None:
|
||||
"""The unit's own 0C peaks over the file's -- only where the file cannot be trusted.
|
||||
|
||||
The file reads everything Blastware reports (checked on 70,042 events): the
|
||||
channel peaks and the vector sum, scaled by the geophone range in its own
|
||||
setup block (4844135), and the mic (5644dbd). The 0C summary is read at
|
||||
fixed offsets and can shift -- BE9441's read 0 and -0.0 for vector sums
|
||||
(bench #4) -- so the file's values stand.
|
||||
|
||||
Except when the file's range does not read (`ev.geo_range` None; never seen
|
||||
in DL2): the decoder then assumes Normal, 8x off for a Sensitive unit. Then
|
||||
the unit's settings decide: Normal confirmed (`unit_range` 0) keeps the
|
||||
file's peaks; Sensitive or unread keeps the unit's own, as before -- a vector
|
||||
sum below the largest channel peak is impossible and is not kept. The mic
|
||||
is the file's either way: its scale does not depend on the geophone range.
|
||||
"""
|
||||
if unit_peaks is None or getattr(ev, "geo_range", None) is not None:
|
||||
return
|
||||
if unit_range in (0, "normal"):
|
||||
return
|
||||
from minimateplus.models import PeakValues
|
||||
|
||||
if unit_peaks is None:
|
||||
return
|
||||
if ev.peak_values is None:
|
||||
ev.peak_values = PeakValues()
|
||||
pv = ev.peak_values
|
||||
micl = getattr(unit_peaks, "micl", None)
|
||||
if micl is not None:
|
||||
pv.micl = micl
|
||||
if geo_range in (0, "normal"):
|
||||
return
|
||||
for name in ("tran", "vert", "long"):
|
||||
value = getattr(unit_peaks, name, None)
|
||||
if value is not None:
|
||||
@@ -149,18 +154,23 @@ def persist_download(dl: DownloadedEvent, *, store: Any, db: Any) -> EventDownlo
|
||||
family = "series4"
|
||||
else:
|
||||
# The same path production's watcher uses for Blastware's own files: the
|
||||
# event is decoded from the file (samples, histogram, setup-block sample
|
||||
# rate and record time), not from the live 5A decode. The unit's 0C mic
|
||||
# goes over the file's, and its peaks too unless Normal range is
|
||||
# confirmed (_overlay_s3_record).
|
||||
# event is decoded from the file -- samples, histogram, peaks, vector sum,
|
||||
# mic, sample rate, record time and the geophone range it was recorded
|
||||
# at -- not from the live 5A decode. The unit's 0C summary is the
|
||||
# download check (verify_s3_download); it fills in only when the file's
|
||||
# range does not read (_overlay_s3_record).
|
||||
if not dl.bw_bytes:
|
||||
raise IngestError(f"{dl.filename}: the download carried no event file; nothing was stored")
|
||||
geo_range = getattr(dl.compliance, "geo_range", None) if dl.compliance else None
|
||||
unit_range = getattr(dl.compliance, "geo_range", None) if dl.compliance else None
|
||||
# The file's range is the setting when it recorded; the live 1A is the
|
||||
# unit's setting now, which may have changed since -- the fallback only.
|
||||
# None lets the store scale by the file's own range.
|
||||
ev, rec = store.save_imported_bw(dl.bw_bytes, source_path=Path(dl.filename),
|
||||
serial_hint=dl.serial, source_kind="sfm-live",
|
||||
geo_range=geo_range if geo_range is not None else "normal")
|
||||
geo_range=None if _file_geo_range(dl.bw_bytes) is not None
|
||||
else unit_range)
|
||||
if ev is not None and dl.event is not None:
|
||||
_overlay_s3_record(ev, getattr(dl.event, "peak_values", None), geo_range)
|
||||
_overlay_s3_record(ev, getattr(dl.event, "peak_values", None), unit_range)
|
||||
family = "series3"
|
||||
if ev is None or ev._waveform_key is None:
|
||||
raise IngestError(f"{dl.filename}: stored the file but could not build a database row")
|
||||
|
||||
+92
-33
@@ -296,9 +296,11 @@ def test_backfill_without_settings_changes_nothing():
|
||||
assert ev.sample_rate is None
|
||||
|
||||
|
||||
# The file path does not yet read a histogram's vector sum the way Blastware does
|
||||
# (the checker's open finding), the mic peak, or a sensitive range, so a live
|
||||
# download keeps the unit's own 0C values for those -- the Series-4 pattern.
|
||||
# Since 2026-11-02 a live download stores what its own file says -- peaks, vector
|
||||
# sum, mic, and the geophone range the event was recorded at -- and the unit's 0C
|
||||
# summary is only the download check. The file's range is the setting when it
|
||||
# recorded; the live 1A is the unit's setting now, which may have changed since.
|
||||
# Only when the file's range does not read (never seen in DL2) does the 1A decide.
|
||||
|
||||
def _with_unit_peaks(dl, *, tran, vert, long, micl, pvs):
|
||||
from minimateplus.models import PeakValues
|
||||
@@ -313,24 +315,99 @@ def _range(geo_range):
|
||||
return cc
|
||||
|
||||
|
||||
def test_a_series3_download_takes_its_peaks_from_the_file_and_its_mic_from_the_unit(sdm):
|
||||
# 2026-10-31: the file now reads a histogram's vector sum as the unit stored it
|
||||
# (0.385 here, as Blastware's report), so the row takes the file's peaks and
|
||||
# vector sum. The unit's 0C summary is read at fixed offsets and can shift
|
||||
# (bench #4 read 0 / -0.0); these believable-but-wrong values must not win.
|
||||
# The mic still comes from the unit: the file reads it as 0.
|
||||
GEO_FIX = Path(__file__).parent / "fixtures" / "geo-range-11-01-26"
|
||||
WRONG = dict(tran=0.21, vert=0.36, long=0.27, micl=0.0009, pvs=0.40) # believable, wrong; clears the old guard
|
||||
|
||||
|
||||
def _download_from(path, serial):
|
||||
from minimateplus.blastware_file import blastware_filename_time
|
||||
when = blastware_filename_time(path.name)
|
||||
return DownloadedEvent(event_id=f"{serial}:01110000:{when:%Y%m%d%H%M%S}", serial=serial, series=3,
|
||||
filename=path.name, verified=None, bw_bytes=path.read_bytes(), timestamp=when)
|
||||
|
||||
|
||||
def _h5_peaks(store, serial, name):
|
||||
from sfm import event_hdf5
|
||||
plot = event_hdf5.plot_json_from_hdf5(store.hdf5_path_for(serial, name))
|
||||
return tuple(max(abs(v) for v in plot["channels"][c]["values"]) for c in ("Tran", "Vert", "Long"))
|
||||
|
||||
|
||||
def _file_range_unread(monkeypatch):
|
||||
# A file whose range does not read: the decoder then assumes Normal.
|
||||
# K441LTON.900 is a Normal file, so its peaks are what such a decode gives.
|
||||
import minimateplus.event_file_io as efi
|
||||
real = efi.decode_blastware_bytes
|
||||
|
||||
def unread(raw, **kw):
|
||||
ev = real(raw, **kw)
|
||||
ev.geo_range = None
|
||||
return ev
|
||||
monkeypatch.setattr(efi, "decode_blastware_bytes", unread)
|
||||
|
||||
|
||||
@pytest.mark.parametrize("compliance", [_range(0), _range(1), None],
|
||||
ids=["unit-says-normal", "unit-says-sensitive", "settings-unread"])
|
||||
def test_a_series3_download_stores_what_its_file_says(sdm, compliance):
|
||||
# K441LTON.900 was recorded in Normal range, whatever the unit is set to now.
|
||||
store, db = sdm
|
||||
dl = _with_unit_peaks(_hist_download("K441LTON.900", "0111f210", datetime.datetime(2026, 10, 26, 17, 0, 36)),
|
||||
tran=0.21, vert=0.36, long=0.27, micl=0.00058, pvs=0.40) # clears the old guard
|
||||
dl.compliance = _range(0) # Normal, confirmed by the unit
|
||||
**WRONG)
|
||||
dl.compliance = compliance
|
||||
row = db.get_event(persist_download(dl, store=store, db=db).db_event_id)
|
||||
assert row["peak_vector_sum"] == pytest.approx(0.3852, abs=1e-4) # Blastware: 0.385
|
||||
assert (row["tran_ppv"], row["vert_ppv"], row["long_ppv"]) == pytest.approx((0.2, 0.385, 0.255), abs=1e-4)
|
||||
assert row["mic_ppv"] == pytest.approx(0.00058, abs=1e-6)
|
||||
assert row["peak_vector_sum"] == pytest.approx(0.3852, abs=1e-4) # Blastware: 0.385
|
||||
assert row["mic_ppv"] == pytest.approx(5.80e-4, abs=2e-6) # Blastware: 106.0 dB(L)
|
||||
assert _h5_peaks(store, "BE9441", "K441LTON.900")[1] == pytest.approx(0.385, abs=0.006)
|
||||
|
||||
|
||||
def test_an_impossible_unit_vector_sum_is_not_kept(sdm):
|
||||
# Bench finding #4: BE9441's 0C read -0.0 for a vector sum whose channels reach 1.08.
|
||||
def test_a_sensitive_waveform_downloaded_with_its_settings_unread_is_blastwares(sdm):
|
||||
# e.g. downloaded while monitoring (the 1A carries no settings). The samples
|
||||
# were scaled as Normal before -- 8x: Vert read 0.44 in the .h5.
|
||||
store, db = sdm
|
||||
dl = _download_from(GEO_FIX / "K557J1KB.RQ0W", "BE9557")
|
||||
row = db.get_event(persist_download(dl, store=store, db=db).db_event_id)
|
||||
assert (row["tran_ppv"], row["vert_ppv"], row["long_ppv"]) == pytest.approx((0.019, 0.055, 0.019), abs=6e-4)
|
||||
assert row["peak_vector_sum"] == pytest.approx(0.061, abs=6e-4) # Blastware's report
|
||||
assert _h5_peaks(store, "BE9557", "K557J1KB.RQ0W") == pytest.approx((0.019, 0.055, 0.019), abs=7e-4)
|
||||
|
||||
|
||||
def test_a_sensitive_histogram_downloaded_with_its_settings_unread_keeps_its_scale(sdm):
|
||||
from minimateplus.event_file_io import decode_blastware_bytes
|
||||
store, db = sdm
|
||||
path = GEO_FIX / "M010HR6K.OA0H"
|
||||
pv = decode_blastware_bytes(path.read_bytes()).peak_values
|
||||
persist_download(_download_from(path, "BE11010"), store=store, db=db)
|
||||
assert _h5_peaks(store, "BE11010", path.name) == pytest.approx((pv.tran, pv.vert, pv.long), abs=7e-4)
|
||||
assert max(_h5_peaks(store, "BE11010", path.name)) < 0.02 # not 8x (Vert would read ~0.07)
|
||||
|
||||
|
||||
def test_when_the_files_range_does_not_read_a_sensitive_units_own_peaks_stand(sdm, monkeypatch):
|
||||
_file_range_unread(monkeypatch)
|
||||
store, db = sdm
|
||||
dl = _with_unit_peaks(_hist_download("K441LTON.900", "0111f210", datetime.datetime(2026, 10, 26, 17, 0, 36)),
|
||||
tran=0.025, vert=0.048, long=0.032, micl=0.0009, pvs=0.0481)
|
||||
dl.compliance = _range(1)
|
||||
row = db.get_event(persist_download(dl, store=store, db=db).db_event_id)
|
||||
assert (row["tran_ppv"], row["vert_ppv"], row["long_ppv"]) == pytest.approx((0.025, 0.048, 0.032), abs=1e-6)
|
||||
assert row["peak_vector_sum"] == pytest.approx(0.0481, abs=1e-6)
|
||||
assert row["mic_ppv"] == pytest.approx(5.80e-4, abs=2e-6) # the mic's scale is not the geophones'
|
||||
assert _h5_peaks(store, "BE9441", "K441LTON.900")[1] == pytest.approx(0.385 / 8, abs=7e-4)
|
||||
|
||||
|
||||
def test_when_the_files_range_does_not_read_and_the_unit_says_normal_the_files_peaks_stand(sdm, monkeypatch):
|
||||
_file_range_unread(monkeypatch)
|
||||
store, db = sdm
|
||||
dl = _with_unit_peaks(_hist_download("K441LTON.900", "0111f210", datetime.datetime(2026, 10, 26, 17, 0, 36)),
|
||||
**WRONG)
|
||||
dl.compliance = _range(0)
|
||||
row = db.get_event(persist_download(dl, store=store, db=db).db_event_id)
|
||||
assert (row["vert_ppv"], row["peak_vector_sum"]) == pytest.approx((0.385, 0.3852), abs=1e-4)
|
||||
|
||||
|
||||
def test_an_impossible_unit_vector_sum_is_not_kept(sdm, monkeypatch):
|
||||
# Bench finding #4: BE9441's 0C read -0.0 for a vector sum whose channels reach
|
||||
# 1.08. The unit's values are used only when neither range reads.
|
||||
_file_range_unread(monkeypatch)
|
||||
store, db = sdm
|
||||
dl = _with_unit_peaks(_hist_download("K441LTOK.R10", "011106a0", datetime.datetime(2026, 10, 26, 16, 6, 37)),
|
||||
tran=0.25, vert=1.08, long=0.195, micl=0.0001, pvs=-0.0)
|
||||
@@ -421,21 +498,3 @@ def test_a_letterless_stored_name_still_matches_a_lettered_download(sdm):
|
||||
store, db = sdm
|
||||
_stored_as(store, db, "K441LTOK.QZ0")
|
||||
assert db.find_event_by_blastware_name("BE9441", "K441LTOK.QZ0H")["blastware_filename"] == "K441LTOK.QZ0"
|
||||
|
||||
|
||||
|
||||
# The file reader computes every peak as if the unit were in Normal range (10 in/s);
|
||||
# a Sensitive (1.25 in/s) unit's file peaks come out 8x off (the checker's 33
|
||||
# waveforms). So the file's peaks are taken only when the unit's settings confirm
|
||||
# Normal -- the download check's rule; Sensitive or unread keeps the unit's own.
|
||||
|
||||
@pytest.mark.parametrize("compliance", [_range(1), None], ids=["sensitive", "range-unread"])
|
||||
def test_without_a_confirmed_normal_range_the_units_peaks_stand(sdm, compliance):
|
||||
store, db = sdm
|
||||
dl = _with_unit_peaks(_hist_download("K441LTON.900", "0111f210", datetime.datetime(2026, 10, 26, 17, 0, 36)),
|
||||
tran=0.025, vert=0.048, long=0.032, micl=0.00058, pvs=0.0481)
|
||||
dl.compliance = compliance
|
||||
row = db.get_event(persist_download(dl, store=store, db=db).db_event_id)
|
||||
assert (row["tran_ppv"], row["vert_ppv"], row["long_ppv"]) == pytest.approx((0.025, 0.048, 0.032), abs=1e-6)
|
||||
assert row["peak_vector_sum"] == pytest.approx(0.0481, abs=1e-6)
|
||||
assert row["mic_ppv"] == pytest.approx(0.00058, abs=1e-6)
|
||||
Reference in new issue
Block a user