serversdownandClaude Opus 5.5 e8eabee4a2 feat(sfm): POST /device/settings/change; retire the legacy config write
DeviceAccess.change_settings refuses before any I/O a request with no
changes, a live change without its preview's revision, or no audit log,
then dispatches the series' change (never retried).  The route returns
the preview (fields old -> new, warnings, blocked, revision) or the
result (fields old/new/now), statuses as the other changes, and marks
the cached by-host config dirty after a live change.

/device/config and /device/config/project now answer 410 with a pointer.
Deleted with them: MiniMateClient.apply_config / set_project_info and
the raw-offset _encode_compliance_config (#46 found it wrong), the
lab script poc_set_project.py and experiments.py's EXP6, both of which
wrote a live unit through it.  Git keeps them.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:51:20 -05:00
serversdownandClaude Opus 5.5 a72d3a98a9 fix(minimateplus): refuse a settings write whose four fields would not read back as asked (#1 review)
_encode_compliance_config patches the raw SUB 1A bytes at offsets measured at
1024 sps (April 2026), where the escape before 04 sits between the mode and the
anchor.  b320a53 moved the decoder to the measured layout (unescaped: mode -7,
rate -6, interval -4, record time +6), which exposed the encoder: on BE9441's
recorded 10-25 Continuous / 4096 block a mode change rewrote the byte in front
of the mode, and on the 10-26 Histogram+Continuous / 2048 block a sample-rate
change landed one byte off.  The old decoder read the same wrong bytes, so such
a write looked as if it had taken.

The encoder now decodes its own result with the decoder and raises ValueError
when mode, sample rate, interval or record time would not read back as asked
(or a field not asked for would change) -- before push_config_raw sends a byte.
No write offset is moved: rewriting the encoder on unescaped bytes is #46's.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 23:56:44 -04:00
serversdownandClaude Opus 5.5 b320a534bc fix(minimateplus): read a MiniMate's mode, sample rate, interval and record time after removing escapes (#1)
The unit escapes 02/03/04/10 in every reply and S3FrameParser keeps the 10 of
10 02/03/04, so on the raw SUB 1A bytes an escaped mode, rate or interval
shifted every field after it: BE9441 at Histogram / 4096 sps / 2 s read back as
0 sps and a 4098 s interval (bench 2026-10-29), and a Continuous unit read as
Single Shot.  The four anchor fields are now read from unescape_reply(data):
mode anchor-7, sample rate anchor-6, interval anchor-4, record time anchor+6 --
measured on all four distinct recorded replies, two of them Blastware's own
writes (15 min, then 2 s).  The old 'anchor-7 = constant 0x10' was the escape
before 04 at 1024 sps.

The channel block and strings still read the raw bytes: their label offsets were
measured there and are wrong unescaped (pinned by a test).  A reply with no
anchor -- BE9441's monitoring-time 1A answer was its device-info block -- leaves
all four None.

Store consequence: none; this is the live settings read.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 23:19:11 -04:00