2 Commits
Author SHA1 Message Date
serversdownandClaude Opus 5.5 e8eabee4a2 feat(sfm): POST /device/settings/change; retire the legacy config write
DeviceAccess.change_settings refuses before any I/O a request with no
changes, a live change without its preview's revision, or no audit log,
then dispatches the series' change (never retried).  The route returns
the preview (fields old -> new, warnings, blocked, revision) or the
result (fields old/new/now), statuses as the other changes, and marks
the cached by-host config dirty after a live change.

/device/config and /device/config/project now answer 410 with a pointer.
Deleted with them: MiniMateClient.apply_config / set_project_info and
the raw-offset _encode_compliance_config (#46 found it wrong), the
lab script poc_set_project.py and experiments.py's EXP6, both of which
wrote a live unit through it.  Git keeps them.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:51:20 -05:00
serversdownandClaude Opus 5.5 1cb11abcef fix(sfm): legacy Series-3 writes and erase refuse a unit that does not answer as Series 3
0xA2 is CONFIRM ERASE on a MiniMate and ends a call-home on a Micromate, and the
legacy host/port routes had no identity check: only the MiniMate parser's
inability to read a Micromate's replies stood between Diagnostics' Erase and a
Micromate (phase 1c safeguard, agreed with Brian 2026-10-28).

_require_series3(unit_serial, expected) refuses (409, 'nothing sent') unless the
unit's own serial is Series 3 and, when ?serial= names one, that one:
- POST /device/config (+ /config/project) and /device/events/erase: the serial
  connect() already reads -- no extra request;
- /device/rescue (when it writes call-home or erases) and POST /device/call_home:
  one SUB 0x15 read (new MiniMateClient.read_serial).
Exempt, with the reason in a comment: legacy monitor start/stop, blind stop, slow
drip, spam -- 0x96/0x97 mean the same on both series (measured), and the rescue
tools must reach a unit too wedged to answer.

Tests: each guarded route refuses a unit answering UM20147 and a different BE
unit with no write call, proceeds for the named unit (normalised), reuses
connect()'s serial where it has one; the blind stop builds no client;
read_serial decodes BE9441's recorded 0x15 reply.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:43:42 -04:00