Final fix wave for phase 3 (start/stop monitoring), per the whole-phase review.
- I1 + M2: every failure after the send has started is a ChangeUnconfirmed
(audit_id, sent = "acknowledged" | "unknown", the cause's HTTP status) whose
message says the frame was sent and names the audit record -- the ring in
place of the ack, the four lost-ack follow-ups, and the three read-back
paths. Series4Session releases the line on it. Every audit finish goes
through one helper; a finish that fails is AuditIncomplete (500) and still
says what happened to the unit. The line is kept.
- I2: device_commands gains `sent` (1 acknowledged, 0 nothing sent, NULL
unknown) and `states` (before / seen / after), with an idempotent ADD COLUMN
in _migrate for a table created earlier on this branch.
- M1: a RADIO RING already buffered is caught before 0x96/0x97 goes out
(pre_send = read_unsolicited, one 10 ms transport read). That is a
CallHomeInProgress with sent=0, not ChangeUnconfirmed.
- M3: Series 3 reads the raw 0x1C flag (new MonitorStatus.state_flag); a byte
other than 0x00/0x10, or a short section, is unknown(...) and refused.
- M8: even_if_already on a unit already in the state notes that the read-back
proves nothing.
- M10: a scan pins `.protocol.execute(` to sfm/device_access/s4.py; both
scans fail closed on a file that does not parse.
- M11: docs corrected (CLAUDE.md phase-2 sentence, phase-3 bullet, REST list;
micromate/protocol.py scope and the 0x49 read_state docstring; s4.py; route
docstrings). "No command has ever been originated" is NOT retracted.
- M12: GET /db/device_commands normalises the serial.
- Minors: unused imports, S3 dry-run frames and 120 s timeout pinned, test
rename, serial-cache and short-0x49 tests, _RUN_STATES comment.
Schema: two NULLable columns on the branch-new device_commands table, added
by _migrate on open; no backfill. No codec change, TOOL_VERSION unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
0x06 content[0:4] moves from the bench tool into the client, tested against a real UM20147 read and its chain-walk count. read_unsolicited() reads without sending, for spotting RADIO RING on an idle session.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
MicromateClient.get_setup() reads SUB 0x1A once and returns a MicromateSetup:
record mode, sample rate, histogram interval, pre-trigger, stop mode, record
time, auto-stop, active sensors, trigger sources, the three geophone trigger
levels, mic type and (linear) mic trigger, job number, scaled distance, and
the four notes. MEASURED FIELDS ONLY -- everything graded inferred or
unknown in the reference stays in .raw.
micromate/setup_block.py holds the decode as pure functions (no I/O), plus
crc_ok(): one checksum rule for 0x1A, 0x08 and 0x2E. A failed checksum
raises SetupChecksumError (a ProtocolError) unless verify=False; a short
block raises either way.
Two things the decoder gets right that a naive one would not:
- the mic comes from channel block 4 (the ACTIVE mic), never blocks 5/6,
which hold the stored settings of whichever mic is NOT fitted;
- distance and charge weight convert back with the unit's own 3.2808 and
2.21, so 45 lb entered on the unit reads 45.0, not 44.89.
TESTS: 69 new. 15 real fixtures (2,103 B each) -- 14 UM20147 reads from the
10-17/10-19 keypad passes, chosen so every field takes at least two values,
plus UM12947's read from Thor's 9-24 capture (other firmware line).
Expected values are what the operator read off the unit's screen, never the
decoder's own output. Fixtures force-added, per the tests/fixtures/
convention. Full suite 541 passed; the 16 pre-existing failures
(test_bw_ascii_report.py 15, test_event_file_io.py 1) are unchanged.
VERIFIED ON HARDWARE: bridges/mm_client_check.py now prints the decoded
setup; against UM20147 every line matched the unit's screen (Brian, 10-19).
Also: the scratch harness uses the library checksum and checks all three
blocks; mm_client_check's stale labels fixed (0x06 content[4:8] is the
likely monitor-log count, not "unexplained"; 11.0BD is no longer "the first
one this code has met").
No codec, store or DB change; no backfill.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
UM20147 captured over USB with mm_client_check.py --capture, read out with
scratch/mm_frame_parse.py: 11 frames each direction, 0 bad checksums. The two
BD-specific response data sections are now verbatim fixtures; only the frame
wrapper is rebuilt, which is sound because the framing is verified 251/251
elsewhere in the same file, and the reconstruction is pinned against the
payload length the parser reported.
Every field lands where the forward-offset model says it should:
data[0] = 0x30 = 48 = 59 - 11 (CB declares 0x2C = 44; the +4 holds)
content[1] = 0x0e monitoring
content[2:10] = 30 Sep 2026 14:00:49 matches the wall clock
content[34:36] = 3.50 V
content[36:44] = 15,000,000 total / 14,848,448 free
AND THE WARNING IS NOW DEMONSTRATED ON THE UNIT IT PREDICTED. Series III reads
battery from data[-10:-8], which on this block is e1 c0 -> 577.92 V. That is
the exact figure the A/B section named, and there is now a test asserting it,
so the reason the offsets are forward cannot be quietly refactored away.
Two corrections to the reference:
1. The four extra BD bytes are `0f a0 00 04`, not `0f a0 00 00`. Only the
first two look fixed. Nothing reads them, but the last is not padding.
2. POLL content[3] VARIES BETWEEN UNITS -- 0x50 on UM12947, 0x56 on UM20147.
It is printable in both cases ("P" and "V"), which is a second, independent
reason the POLL block cannot be parsed by scanning for printable runs: a
scan returns "PInstantel" on one unit and "VInstantel" on the other. The
fixed offset content[4] was the right call for a reason I had not seen.
The model string sits at content[26] on both firmware lines; only its tail
differs, so anchoring on "MM/" remains correct.
98 micromate tests pass. Full suite unchanged at 16 pre-existing failures.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
UM20147 read over USB by mm_client_check.py. The Thor firmware line was
entirely inference until now, and two of its three differences were covered
only by SYNTHESISED test frames. All three held:
- flags = 0x03 identifies the line -> reported firmware_line="thor". That is
only reachable if `10 03` in the flags position destuffs before indexing,
since 0x03 is ETX -- so the escaped-flags case is confirmed too.
- the model string is shorter -> reported "MM/ISEE/S" exactly. Anchoring the
search on b"MM/" rather than a fixed span is what made this work.
- the 0x1C block is 4 bytes longer with the extras TRAILING, so from-the-start
offsets survive -> battery 3.55 V and a clock correct to the second.
That last one is the one that mattered. Series III's from-the-end offsets
would have given this unit 577.92 V, which is why mm_client_check watches for
an impossible voltage: it is a free self-check on exactly the inference most
likely to be wrong.
Also clean: serial UM20147, 5 setups (factory.MMB -> test2.mmb), active setup
test2.mmb, 15,000,000 B total and free, 21 reads / 2,165 B in.
"One protocol stack drives the whole fleet regardless of firmware line" -- the
headline finding of 2026-09-23 -- is now demonstrated by a working client
rather than by matching response SUBs.
Test and docstring claims downgraded from inference to confirmed where the
hardware settled them, and left as synthesised-frame notes where it did not:
the BEHAVIOUR is confirmed but raw BD bytes are still not in the repo.
Added --capture DIR to mm_client_check: writes a raw_bw_*/raw_s3_* pair in the
layout scratch/mm_frame_parse.py already reads, so a run on an unfamiliar unit
becomes a test fixture without setting up a relay. Verified by round-tripping
its own output through that parser: 28 frames, 0 bad checksums.
Still not covered: a download from a BD unit (UM20147 had no events stored, so
the chunk walk remains CB-only), raw BD fixture bytes, a monitoring unit, a
nearly-full buffer, and the inbound call-home session.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
Step 3 of docs/micromate_client_spec.md: micromate/client.py, two models in
micromate/models.py, 26 offline tests. Every response constant in the tests
is a real captured data section from UM12947.
Field offsets were measured rather than taken from the spec, which turned up
one general rule and one trap:
THE RESPONSE SHAPE. Every response carries an 11-byte prefix and content
starts at data[11]. One rule, every command.
THE TRAP: data[0] is the content length & 0xFF, with no high byte anywhere in
the prefix. It is therefore correct for every response under 256 bytes --
most of them -- and then reports 44 for a 2,092-byte setup block, 30 for a
286-byte monitor-log record, and 0 for a 1,024-byte download chunk. 182 of
251 captured responses agree with a naive read; the 69 that disagree are
exactly the ones >= 256 bytes.
That is the third length in this protocol read too narrow, after
payload[9]-vs-payload[8:10] in the probe response. The client takes content
as data[11:] and lets the frame's own length bound it -- nothing needs the
declared length, since the frame already knows how long it is.
Also measured:
- POLL content[3] is 0x50, printable as "P", immediately before "Instantel".
A generic printable-run scan therefore returns "PInstantel" -- it caught a
test, not a unit. Vendor comes from a fixed offset; the model is found by
searching for "MM/", which is structural rather than positional and so
survives the Thor line's shorter "MM/ISEE/S".
- The setup walk terminates on an EMPTY NAME, not an error: 23 responses, 22
names, factory.MMB first through TEST1.mmb last.
- The 0x1C clock has an unidentified byte at content[6]; the hour is at
content[7]. The protocol reference's 0x1C section already had this right
and names the byte -- its one-line summary in the divergences list reads as
six contiguous fields and is the version not to trust. Re-verified against
three captures: 19:12:25, 19:13:34 and 01:14:05 against filenames stamped
19:12:14, 19:12:14 and 01:14:03.
- Battery and memory are read FORWARD from content start, never backward from
the end. This block is 4 bytes longer on the Thor line; the Series III
from-the-end offsets give a 11.0BD unit 577.92 V. A test appends the four
trailing bytes and asserts the forward offsets survive.
connect() is narrower than the spec asked. The spec said to mirror Thor's
POLL -> SERIAL -> 0x49 -> POLL "because it is known-good"; measurement showed
that is Thor's connection check (3 of 8 sessions) and its fourth frame repeats
its first. So connect() sends the three reads that gather something, and
0x01 is not read at all -- Thor never reads it, its layout is unmapped, and
firmware_line comes free from any response's flags byte. If a unit ever
refuses the next command after a cold connect, put the fourth POLL back and
record it.
A dead clock battery yields device_time=None rather than failing the whole
state read; an unreadable active setup yields active_setup=None rather than
failing connect. Both are real device states.
Still verified only against 11.0CB and only over USB. The BD offsets follow
from the extra bytes being trailing, which is documented but not something
this code has seen.
Full suite unchanged at 16 pre-existing failures; 445 passed, up 26.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL