feat(micromate): get_setup() -- the setup block decoded, checksum-verified, and read off a real unit
MicromateClient.get_setup() reads SUB 0x1A once and returns a MicromateSetup: record mode, sample rate, histogram interval, pre-trigger, stop mode, record time, auto-stop, active sensors, trigger sources, the three geophone trigger levels, mic type and (linear) mic trigger, job number, scaled distance, and the four notes. MEASURED FIELDS ONLY -- everything graded inferred or unknown in the reference stays in .raw. micromate/setup_block.py holds the decode as pure functions (no I/O), plus crc_ok(): one checksum rule for 0x1A, 0x08 and 0x2E. A failed checksum raises SetupChecksumError (a ProtocolError) unless verify=False; a short block raises either way. Two things the decoder gets right that a naive one would not: - the mic comes from channel block 4 (the ACTIVE mic), never blocks 5/6, which hold the stored settings of whichever mic is NOT fitted; - distance and charge weight convert back with the unit's own 3.2808 and 2.21, so 45 lb entered on the unit reads 45.0, not 44.89. TESTS: 69 new. 15 real fixtures (2,103 B each) -- 14 UM20147 reads from the 10-17/10-19 keypad passes, chosen so every field takes at least two values, plus UM12947's read from Thor's 9-24 capture (other firmware line). Expected values are what the operator read off the unit's screen, never the decoder's own output. Fixtures force-added, per the tests/fixtures/ convention. Full suite 541 passed; the 16 pre-existing failures (test_bw_ascii_report.py 15, test_event_file_io.py 1) are unchanged. VERIFIED ON HARDWARE: bridges/mm_client_check.py now prints the decoded setup; against UM20147 every line matched the unit's screen (Brian, 10-19). Also: the scratch harness uses the library checksum and checks all three blocks; mm_client_check's stale labels fixed (0x06 content[4:8] is the likely monitor-log count, not "unexplained"; 11.0BD is no longer "the first one this code has met"). No codec, store or DB change; no backfill. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
a74d3c9b00
commit
b3aff4ed66
22 files changed
+622
-35
No files matched your search
+51
-13
@@ -18,9 +18,9 @@ verified that way:
|
||||
than using idle-gap detection, which should be strictly more robust — but
|
||||
"should be" is the point of this script.
|
||||
* **the other firmware line.** `11.0BD` reports `flags = 0x03`, a shorter
|
||||
model string, and a `SUB 0x1C` block 4 bytes longer. Everything about that
|
||||
is currently inference from one 2026-09-23 sweep whose captures never
|
||||
landed in the repo.
|
||||
model string, and a `SUB 0x1C` block 4 bytes longer. Inferred from a
|
||||
2026-09-23 sweep; **confirmed on UM20147 2026-09-30** (forward offsets read
|
||||
a correct battery and clock).
|
||||
|
||||
Run it over both paths and diff the two reports. Anything that differs beyond
|
||||
timings is a finding.
|
||||
@@ -244,7 +244,36 @@ def _select(refs, which: str):
|
||||
return [r for r in refs if r.key_hex.lower() == which]
|
||||
|
||||
|
||||
def step(label: str, fn):
|
||||
def _setup_lines(s) -> list[str]:
|
||||
"""A decoded setup, laid out the way the unit's own menus group it."""
|
||||
def sensors(geo: bool, mic: bool) -> str:
|
||||
return " + ".join(n for n, on in (("geophones", geo), ("mic", mic)) if on) or "none"
|
||||
|
||||
stop = f"Auto, after {s.auto_stop_after_s} s quiet" if s.auto_record_stop else "Fixed"
|
||||
if s.mic_type == "linear":
|
||||
mic = f"linear, trigger {s.mic_trigger_db:.1f} dB ({s.mic_trigger_psi:.5f} psi)"
|
||||
else:
|
||||
mic = s.mic_type
|
||||
sd = (f"on: {s.distance_ft:.1f} ft, {s.charge_weight_lb:.1f} lb"
|
||||
+ (f" -> {s.scaled_distance:.2f}" if s.scaled_distance else "")
|
||||
if s.scaled_distance_enabled else "off")
|
||||
return [
|
||||
f"record mode {s.record_mode_name}",
|
||||
f"sample rate {s.sample_rate} sps",
|
||||
f"histogram interval {s.histogram_interval_s} s",
|
||||
f"record time {s.record_time_s:g} s stop: {stop}",
|
||||
f"pre-trigger {s.pretrigger_s:g} s",
|
||||
f"sensors on {sensors(s.geophones_active, s.mic_active)}",
|
||||
f"trigger on {sensors(s.trigger_on_geophones, s.trigger_on_mic)}",
|
||||
"geophone trigger " + " / ".join(f"{v:.3f}" for v in s.geo_trigger_ips) + " in/s",
|
||||
f"microphone {mic}",
|
||||
f"job number {s.job_number} ({'on' if s.job_number_enabled else 'off'})",
|
||||
f"scaled distance {sd}",
|
||||
*(f"note {k:<15}{v!r}" for k, v in s.notes.items()),
|
||||
]
|
||||
|
||||
|
||||
def step(label: str, fn, show=None):
|
||||
"""Run one read, report how long it took and what it returned."""
|
||||
t0 = time.monotonic()
|
||||
try:
|
||||
@@ -256,6 +285,8 @@ def step(label: str, fn):
|
||||
shown = value if isinstance(value, str) else repr(value)
|
||||
if isinstance(value, list):
|
||||
shown = f"{len(value)} entries"
|
||||
if show:
|
||||
shown = show(value)
|
||||
print(f" {label:.<26} {ms:7.0f} ms {shown}")
|
||||
return value
|
||||
|
||||
@@ -319,9 +350,8 @@ def main() -> int:
|
||||
f"fw={info.firmware_line} monitoring={info.monitoring}")
|
||||
print(f" active setup={info.active_setup!r}")
|
||||
if info.firmware_line == "thor":
|
||||
print(" *** 11.0BD unit — the FIRST one this code has met. ***")
|
||||
print(" *** Check the battery and clock below carefully: ***")
|
||||
print(" *** its 0x1C block is 4 bytes longer. ***")
|
||||
print(" (11.0BD / Thor line: 0x1C is 4 B longer -- read forward, "
|
||||
"confirmed 2026-09-30)")
|
||||
|
||||
state = step("get_state()", mm.get_state)
|
||||
if state:
|
||||
@@ -333,22 +363,30 @@ def main() -> int:
|
||||
print(" *** device clock did not decode — dump raw below. ***")
|
||||
print(f" raw 0x1C content: {_content(state.raw).hex(' ')}")
|
||||
|
||||
setup = step("get_setup()", mm.get_setup, show=lambda s: f"{s.name} (checksum ok)")
|
||||
if setup:
|
||||
print(" check each line against the unit's screen:")
|
||||
for line in _setup_lines(setup):
|
||||
print(f" {line}")
|
||||
|
||||
setups = step("list_setups()", mm.list_setups)
|
||||
if setups:
|
||||
print(f" first={setups[0]!r} last={setups[-1]!r}")
|
||||
|
||||
# ── SUB 0x06: is content[0:4] really the event count? ─────────────
|
||||
# Two samples on one unit said yes, and THOR reads it BEFORE the chain
|
||||
# walk then stops without ever reading the sentinel. A third value
|
||||
# either confirms it or kills it.
|
||||
# ── SUB 0x06: event count, and (likely) the monitor-log count ─────
|
||||
# content[0:4] is the event count: 3/3 against the chain walk, and THOR's
|
||||
# own ReadEventRecordCount agrees. content[4:8] was once recorded as "a
|
||||
# constant 9" -- it read 47 during the 10-14 ACH session against THOR's
|
||||
# "Monitor Log count: 45", so it is very likely the monitor-log count.
|
||||
# Still graded a strong candidate, not settled (reference, 10-14).
|
||||
claimed = None
|
||||
raw06 = step("0x06 storage range", mm.protocol.read_storage_range)
|
||||
if raw06:
|
||||
c = _content(raw06)
|
||||
claimed = int.from_bytes(c[0:4], "big")
|
||||
print(f" content[0:4] = {claimed} <- CANDIDATE: event count")
|
||||
print(f" content[0:4] = {claimed} <- event count")
|
||||
print(f" content[4:8] = {int.from_bytes(c[4:8],'big')} "
|
||||
f"<- unexplained (read 9 alongside a 6 on UM12947)")
|
||||
f"<- likely the monitor-log count (strong candidate)")
|
||||
|
||||
if a.download:
|
||||
print("\n event chain (read-only), via MicromateClient:")
|
||||
|
||||
+14
-1
@@ -39,8 +39,9 @@ from typing import Optional
|
||||
|
||||
from minimateplus.transport import BaseTransport
|
||||
|
||||
from .models import MicromateDeviceInfo, MicromateEventRef, MicromateState
|
||||
from .models import MicromateDeviceInfo, MicromateEventRef, MicromateSetup, MicromateState
|
||||
from .protocol import MicromateProtocol, ProtocolError
|
||||
from .setup_block import decode_setup
|
||||
|
||||
log = logging.getLogger(__name__)
|
||||
|
||||
@@ -300,6 +301,18 @@ class MicromateClient:
|
||||
"""`SUB 0x41` — the loaded `.MMB` file name, e.g. `TEST1.mmb`."""
|
||||
return _cstring(_content(self._proto.read_active_setup_name()))
|
||||
|
||||
def get_setup(self, *, verify: bool = True) -> MicromateSetup:
|
||||
"""`SUB 0x1A` — what the unit is set to, decoded. One read.
|
||||
|
||||
Raises ``SetupChecksumError`` if the block's CRC fails, unless
|
||||
``verify=False``. Offsets and what is deliberately not decoded are in
|
||||
``micromate/setup_block.py``.
|
||||
|
||||
⚠ This reads the keypad's EDIT BUFFER: if someone is in the unit's setup
|
||||
menu, unsaved values come back.
|
||||
"""
|
||||
return decode_setup(_content(self._proto.read_compliance_config()), verify=verify)
|
||||
|
||||
def list_setups(self) -> list[str]:
|
||||
"""`0x3F` then `0x40`… — every setup file stored on the unit.
|
||||
|
||||
|
||||
@@ -22,6 +22,7 @@ shrink or disappear.
|
||||
from __future__ import annotations
|
||||
|
||||
import datetime
|
||||
import math
|
||||
from dataclasses import dataclass, field
|
||||
from typing import Any, Dict, Optional, Tuple
|
||||
|
||||
@@ -480,6 +481,81 @@ class MicromateState:
|
||||
return " ".join(bits)
|
||||
|
||||
|
||||
_RECORD_MODES = {0x01: "Waveform", 0x02: "Waveform Manual", 0x03: "Histogram", 0x04: "Histogram Combo"}
|
||||
|
||||
# The unit's OWN conversion constants, identified bit-exactly from what it
|
||||
# stored for keypad entries (2026-10-19). Not the textbook 3.28084 / 2.20462:
|
||||
# convert back with these, or 45 lb entered on the unit reads as 44.89 lb.
|
||||
_FT_PER_M = 3.2808
|
||||
_LB_PER_KG = 2.21
|
||||
_PA_PER_PSI = 6894.757
|
||||
_P_REF_PA = 20e-6 # dB re 20 µPa
|
||||
|
||||
|
||||
@dataclass
|
||||
class MicromateSetup:
|
||||
"""A unit's active setup, from ``SUB 0x1A`` — see ``micromate/setup_block.py``.
|
||||
|
||||
**Measured fields only.** Each was located by changing that one setting on a
|
||||
unit's keypad and watching the bytes; anything graded inferred or unknown in
|
||||
the protocol reference is left in ``raw`` rather than guessed at here.
|
||||
|
||||
⚠ This is what the unit is set to *right now* — including unsaved edits if
|
||||
someone is in its setup menu, because ``0x1A`` reads the keypad's edit
|
||||
buffer. Values are in the units the unit stores, whatever it displays:
|
||||
in/s, psi, metres, kilograms.
|
||||
"""
|
||||
|
||||
name: str # ⚠ ".MMB" after a keypad save, ".mmb" after a load
|
||||
record_mode: int # see record_mode_name
|
||||
sample_rate: int # samples per second
|
||||
histogram_interval_s: int
|
||||
pretrigger_s: float # positive; the unit stores it negative
|
||||
auto_record_stop: bool # False = Fixed record time
|
||||
record_time_s: float
|
||||
auto_stop_after_s: int # quiet time before an Auto stop
|
||||
geophones_active: bool
|
||||
mic_active: bool
|
||||
trigger_on_geophones: bool
|
||||
trigger_on_mic: bool
|
||||
geo_trigger_ips: Tuple[float, float, float] # Tran, Vert, Long
|
||||
mic_type: str # "linear" | "sound_level" | "unknown (<code>)"
|
||||
mic_trigger_psi: Optional[float] # linear mic only; SLM units not measured
|
||||
job_number_enabled: bool
|
||||
job_number: int # kept while switched off
|
||||
scaled_distance_enabled: bool
|
||||
distance_m: float
|
||||
charge_weight_kg: float
|
||||
notes: Dict[str, str] # label -> value, in the unit's order
|
||||
raw: bytes = field(default=b"", repr=False) # the 2,092-byte content
|
||||
|
||||
@property
|
||||
def record_mode_name(self) -> str:
|
||||
return _RECORD_MODES.get(self.record_mode, f"unknown (0x{self.record_mode:02x})")
|
||||
|
||||
@property
|
||||
def mic_trigger_db(self) -> Optional[float]:
|
||||
"""dB re 20 µPa. Matches the unit's screen to ±0.001 dB on 131 and 140."""
|
||||
if not self.mic_trigger_psi:
|
||||
return None
|
||||
return 20.0 * math.log10(self.mic_trigger_psi * _PA_PER_PSI / _P_REF_PA)
|
||||
|
||||
@property
|
||||
def distance_ft(self) -> float:
|
||||
return self.distance_m * _FT_PER_M
|
||||
|
||||
@property
|
||||
def charge_weight_lb(self) -> float:
|
||||
return self.charge_weight_kg * _LB_PER_KG
|
||||
|
||||
@property
|
||||
def scaled_distance(self) -> Optional[float]:
|
||||
"""ft / √lb, as the unit computes it for display. It is not stored."""
|
||||
if self.charge_weight_kg <= 0:
|
||||
return None
|
||||
return self.distance_ft / math.sqrt(self.charge_weight_lb)
|
||||
|
||||
|
||||
@dataclass
|
||||
class MicromateEventRef:
|
||||
"""One entry in a unit's event chain, from `1E`/`1F` and optionally `0x0C`.
|
||||
|
||||
@@ -0,0 +1,154 @@
|
||||
"""
|
||||
setup_block.py — the Micromate setup block (`SUB 0x1A`), decoded.
|
||||
|
||||
Pure byte interpretation: no I/O, no device. `MicromateClient.get_setup()`
|
||||
does the read and hands the content here.
|
||||
|
||||
Every offset below is into **content** (response data minus its 11-byte prefix)
|
||||
and was measured on UM20147 (`11.0BD`) by changing one setting on the unit's own
|
||||
keypad and watching which bytes moved, 2026-10-17/19. Method, grades and the
|
||||
fields deliberately left out are in docs/micromate_protocol_reference.md, under
|
||||
*The `0x1A` field map from a keypad pass* and the 2026-10-19 section after it.
|
||||
"""
|
||||
|
||||
from __future__ import annotations
|
||||
|
||||
import struct
|
||||
|
||||
from .models import MicromateSetup
|
||||
from .protocol import ProtocolError
|
||||
|
||||
|
||||
class SetupChecksumError(ProtocolError):
|
||||
"""A config block's trailing CRC does not match its contents."""
|
||||
|
||||
|
||||
_CRC_POLY = 0x1021
|
||||
_CRC_INIT = 0x1D0F # CRC-16/AUG-CCITT
|
||||
_CONTENT_SIZE = 2092 # = content[0:2] (2090) + the 2-byte CRC
|
||||
|
||||
# ── Head of the block ─────────────────────────────────────────────────────────
|
||||
_MODE = 5 # 01 Waveform · 02 Manual · 03 Histogram · 04 Combo
|
||||
_SAMPLE_RATE = slice(6, 8) # uint16 BE ⚠ 4096 puts a literal 0x10 here
|
||||
_HIST_INTERVAL = slice(8, 10) # uint16 BE seconds
|
||||
_PRETRIGGER = 12 # f32 BE, NEGATIVE seconds
|
||||
_STOP_MODE = 17 # 00 Fixed · 01 Auto (u8 or u16 BE [16:18] — unresolved)
|
||||
_RECORD_TIME = 18 # f32 BE seconds
|
||||
_AUTO_STOP = 23 # seconds (u8 or u16 BE [22:24] — unresolved)
|
||||
_SENSORS = 25 # bitmask: 0x07 geophones, 0x08 mic
|
||||
_TRIGGERS = 29 # same bits: which sensors may trigger
|
||||
_DISTANCE = 30 # f32 BE metres (keypad: ft / 3.2808)
|
||||
_CHARGE = 34 # f32 BE kg (keypad: lb / 2.21)
|
||||
_REPORT_FLAGS = 39 # 0x02 job number on · 0x08 scaled distance on · 0x01 ?
|
||||
_JOB_NUMBER = slice(40, 42) # uint16 BE
|
||||
_NAME = slice(42, 86) # setup file name, null-padded
|
||||
|
||||
_GEO_BITS, _MIC_BIT = 0x07, 0x08
|
||||
_JOB_ON, _SCALED_ON = 0x02, 0x08
|
||||
|
||||
# ── Notes: four [label 22][value 42] pairs on a 64-byte stride ────────────────
|
||||
_NOTE_LABEL, _NOTE_VALUE, _NOTE_STRIDE, _NOTES = 122, 144, 64, 4
|
||||
|
||||
# ── Channel blocks, 48 bytes each from content[1708] ──────────────────────────
|
||||
# 1-3 are the geophones. Block 4 is the ACTIVE mic: a byte copy of block 5
|
||||
# (stored linear settings) or block 6 (stored sound-level settings). Read the
|
||||
# mic from block 4 only — 5 and 6 describe whichever mic is NOT selected.
|
||||
_CHANNELS, _CHANNEL_SIZE = 1708, 48
|
||||
_CH_SENSOR_CODE = slice(4, 8) # uint32 BE: 1 geophone, 2 linear mic, 9 SLM, 0 off
|
||||
_CH_TRIGGER = 30 # f32 BE: geophone in/s, linear mic psi
|
||||
_ACTIVE_MIC = 3 # block index (0-based)
|
||||
_MIC_TYPES = {2: "linear", 9: "sound_level"}
|
||||
|
||||
|
||||
def _crc16_aug_ccitt(data: bytes) -> int:
|
||||
c = _CRC_INIT
|
||||
for b in data:
|
||||
c ^= b << 8
|
||||
for _ in range(8):
|
||||
c = ((c << 1) ^ _CRC_POLY) & 0xFFFF if c & 0x8000 else (c << 1) & 0xFFFF
|
||||
return c
|
||||
|
||||
|
||||
def crc_ok(content: bytes) -> bool:
|
||||
"""True if a config block's trailing checksum matches its contents.
|
||||
|
||||
One rule covers the setup (`0x1A`), preferences (`0x08`) and `0x2E` blocks:
|
||||
``content[0:2]`` is a uint16 BE length N, and a CRC-16/AUG-CCITT over
|
||||
``content[0:N-2]`` is stored big-endian at ``content[N:N+2]``. The two bytes
|
||||
at ``[N-2:N]`` are zero and not covered. `0x2C` (call-home) has no checksum.
|
||||
|
||||
A block too short to hold its own declared length reads as bad, not as an
|
||||
error: a truncated read is exactly what this exists to catch.
|
||||
"""
|
||||
if len(content) < 2:
|
||||
return False
|
||||
n = int.from_bytes(content[0:2], "big")
|
||||
if n < 2 or len(content) < n + 2:
|
||||
return False
|
||||
return _crc16_aug_ccitt(content[: n - 2]) == int.from_bytes(content[n : n + 2], "big")
|
||||
|
||||
|
||||
def _f32(c: bytes, offset: int) -> float:
|
||||
return struct.unpack_from(">f", c, offset)[0]
|
||||
|
||||
|
||||
def _ascii(buf: bytes) -> str:
|
||||
return buf.split(b"\x00")[0].decode("ascii", "replace").strip()
|
||||
|
||||
|
||||
def _channel(c: bytes, index: int) -> bytes:
|
||||
start = _CHANNELS + index * _CHANNEL_SIZE
|
||||
return c[start : start + _CHANNEL_SIZE]
|
||||
|
||||
|
||||
def decode_setup(content: bytes, *, verify: bool = True) -> MicromateSetup:
|
||||
"""Decode a setup block's content (``0x1A`` data minus its 11-byte prefix).
|
||||
|
||||
Raises ``SetupChecksumError`` if the trailing CRC does not match — unless
|
||||
``verify=False``, which decodes anyway, for looking at what a bad read held.
|
||||
A block shorter than 2,092 bytes raises ``ProtocolError`` either way: the
|
||||
checksum is optional, the bounds are not.
|
||||
"""
|
||||
if len(content) < _CONTENT_SIZE:
|
||||
raise ProtocolError(f"setup block content is {len(content)} B, need {_CONTENT_SIZE}")
|
||||
if verify and not crc_ok(content):
|
||||
raise SetupChecksumError(
|
||||
"setup block checksum mismatch — a short or corrupt read "
|
||||
"(decode_setup(..., verify=False) to inspect it anyway)"
|
||||
)
|
||||
c = content
|
||||
mic = _channel(c, _ACTIVE_MIC)
|
||||
mic_code = int.from_bytes(mic[_CH_SENSOR_CODE], "big")
|
||||
mic_type = _MIC_TYPES.get(mic_code, f"unknown ({mic_code})")
|
||||
flags = c[_REPORT_FLAGS]
|
||||
|
||||
notes = {}
|
||||
for n in range(_NOTES):
|
||||
label = _ascii(c[_NOTE_LABEL + n * _NOTE_STRIDE : _NOTE_VALUE + n * _NOTE_STRIDE])
|
||||
value = _ascii(c[_NOTE_VALUE + n * _NOTE_STRIDE : _NOTE_LABEL + (n + 1) * _NOTE_STRIDE])
|
||||
notes[label] = value
|
||||
|
||||
return MicromateSetup(
|
||||
name=_ascii(c[_NAME]),
|
||||
record_mode=c[_MODE],
|
||||
sample_rate=int.from_bytes(c[_SAMPLE_RATE], "big"),
|
||||
histogram_interval_s=int.from_bytes(c[_HIST_INTERVAL], "big"),
|
||||
pretrigger_s=-_f32(c, _PRETRIGGER),
|
||||
auto_record_stop=bool(c[_STOP_MODE]),
|
||||
record_time_s=_f32(c, _RECORD_TIME),
|
||||
auto_stop_after_s=c[_AUTO_STOP],
|
||||
geophones_active=bool(c[_SENSORS] & _GEO_BITS),
|
||||
mic_active=bool(c[_SENSORS] & _MIC_BIT),
|
||||
trigger_on_geophones=bool(c[_TRIGGERS] & _GEO_BITS),
|
||||
trigger_on_mic=bool(c[_TRIGGERS] & _MIC_BIT),
|
||||
geo_trigger_ips=tuple(_f32(_channel(c, i), _CH_TRIGGER) for i in range(3)),
|
||||
mic_type=mic_type,
|
||||
mic_trigger_psi=_f32(mic, _CH_TRIGGER) if mic_type == "linear" else None,
|
||||
job_number_enabled=bool(flags & _JOB_ON),
|
||||
job_number=int.from_bytes(c[_JOB_NUMBER], "big"),
|
||||
scaled_distance_enabled=bool(flags & _SCALED_ON),
|
||||
distance_m=_f32(c, _DISTANCE),
|
||||
charge_weight_kg=_f32(c, _CHARGE),
|
||||
notes=notes,
|
||||
raw=c,
|
||||
)
|
||||
+10
-21
@@ -52,6 +52,7 @@ sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
|
||||
|
||||
from bridges.mm_client_check import StdlibSerial # noqa: E402
|
||||
from micromate.client import MicromateClient # noqa: E402
|
||||
from micromate.setup_block import crc_ok # noqa: E402
|
||||
from minimateplus.transport import TcpTransport # noqa: E402
|
||||
|
||||
SNAP_ROOT = Path(__file__).resolve().parent / "mm_config_snaps"
|
||||
@@ -138,28 +139,16 @@ def _interps(a: bytes, b: bytes, off: int, run: int) -> list[str]:
|
||||
return out
|
||||
|
||||
|
||||
def crc16_aug_ccitt(data: bytes) -> int:
|
||||
"""CRC-16/AUG-CCITT: poly 0x1021, init 0x1D0F, no reflection, xorout 0."""
|
||||
c = 0x1D0F
|
||||
for x in data:
|
||||
c ^= x << 8
|
||||
for _ in range(8):
|
||||
c = ((c << 1) ^ 0x1021) & 0xFFFF if c & 0x8000 else (c << 1) & 0xFFFF
|
||||
return c
|
||||
# Blocks that carry the config checksum (micromate.setup_block.crc_ok): N =
|
||||
# content[0:2], CRC-16/AUG-CCITT over [0:N-2] stored at [N:N+2]. 0x2C has none.
|
||||
CRC_BLOCKS = {"1A_compliance", "08_event_index", "2E_trigger"}
|
||||
|
||||
|
||||
def crc_status_1a(raw: bytes) -> str:
|
||||
"""Check 0x1A's trailer: CRC over content[0:2088], stored BE at [2090:2092].
|
||||
|
||||
Found 2026-10-17 from one keypad diff and confirmed on 23 snapshots plus
|
||||
UM12947's 9-24 capture. A mismatch means a short or corrupt read -- or
|
||||
that the layout is not what this assumes, which is worth knowing too.
|
||||
"""
|
||||
def crc_status(raw: bytes) -> str:
|
||||
"""A mismatch means a short or corrupt read -- or a block this rule misses."""
|
||||
c = raw[CONTENT:]
|
||||
if len(c) < 2092:
|
||||
return f"CRC n/a (content {len(c)} B < 2092)"
|
||||
want, got = crc16_aug_ccitt(c[:2088]), int.from_bytes(c[2090:2092], "big")
|
||||
return f"CRC ok ({got:04x})" if want == got else f"CRC MISMATCH computed {want:04x}, stored {got:04x}"
|
||||
stored = c[int.from_bytes(c[0:2], "big"):][:2].hex() if len(c) >= 2 else "--"
|
||||
return f"CRC ok ({stored})" if crc_ok(c) else f"CRC MISMATCH (stored {stored})"
|
||||
|
||||
|
||||
def _runs(a: bytes, b: bytes, ignore: set[int]) -> list[tuple[int, int]]:
|
||||
@@ -314,8 +303,8 @@ def cmd_watch(mm: MicromateClient, serial: str, interval: float,
|
||||
f"{a[off:off + run].hex()} -> {b[off:off + run].hex()}")
|
||||
for line in _interps(a, b, off, run):
|
||||
print(f" {line}")
|
||||
if name == "1A_compliance":
|
||||
print(f" {crc_status_1a(cur[name])}")
|
||||
if name in CRC_BLOCKS:
|
||||
print(f" {crc_status(cur[name])}")
|
||||
print(flush=True)
|
||||
prev = cur
|
||||
except KeyboardInterrupt:
|
||||
|
||||
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
@@ -22,6 +22,7 @@ sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||||
from micromate.client import CONTENT, MicromateClient, _content, _cstring
|
||||
from micromate.framing import ETX, STX, checksum, stuff
|
||||
from micromate.protocol import ProtocolError
|
||||
from micromate.setup_block import SetupChecksumError
|
||||
|
||||
FLAGS_CB, FLAGS_THOR = 0xC5, 0x03
|
||||
|
||||
@@ -491,3 +492,47 @@ def test_the_four_extra_bd_bytes_are_not_all_zero():
|
||||
"""
|
||||
assert _content(MS_BD_MONITORING)[44:] == bytes.fromhex("0fa00004")
|
||||
assert _content(MS_IDLE)[44:] == b"", "the CB block has no such tail"
|
||||
|
||||
|
||||
# ── get_setup() ───────────────────────────────────────────────────────────────
|
||||
# Decoding itself is covered field by field in test_micromate_setup.py; these
|
||||
# check the client's read, its framing round trip and the verify switch.
|
||||
|
||||
SETUP_FIXTURES = os.path.join(os.path.dirname(os.path.abspath(__file__)), "fixtures", "micromate-setup")
|
||||
|
||||
|
||||
def _setup_read(name: str) -> bytes:
|
||||
with open(os.path.join(SETUP_FIXTURES, f"{name}.bin"), "rb") as f:
|
||||
return f.read()
|
||||
|
||||
|
||||
def test_get_setup_is_one_read_of_0x1a():
|
||||
"""One frame -- not Series III's four-frame compliance sequence."""
|
||||
mm, t = client([frame(0xE5, _setup_read("um20147_baseline"))])
|
||||
mm.get_setup()
|
||||
assert [w[5] for w in t.written] == [0x1A]
|
||||
|
||||
|
||||
def test_get_setup_survives_a_literal_dle_through_the_framing():
|
||||
"""4096 sps puts 0x10 in the payload, which the unit must escape on the wire
|
||||
and the parser must unescape. Wrong either way and the rate reads wrong or
|
||||
the CRC fails."""
|
||||
mm, _ = client([frame(0xE5, _setup_read("um20147_4096sps"))])
|
||||
s = mm.get_setup()
|
||||
assert s.sample_rate == 4096
|
||||
assert s.raw == _setup_read("um20147_4096sps")[CONTENT:]
|
||||
|
||||
|
||||
def test_get_setup_raises_on_a_corrupt_read_by_default():
|
||||
data = bytearray(_setup_read("um20147_baseline"))
|
||||
data[CONTENT + 5] = 0x05
|
||||
mm, _ = client([frame(0xE5, bytes(data))])
|
||||
with pytest.raises(SetupChecksumError):
|
||||
mm.get_setup()
|
||||
|
||||
|
||||
def test_get_setup_verify_false_returns_the_corrupt_read():
|
||||
data = bytearray(_setup_read("um20147_baseline"))
|
||||
data[CONTENT + 5] = 0x05
|
||||
mm, _ = client([frame(0xE5, bytes(data))])
|
||||
assert mm.get_setup(verify=False).record_mode == 0x05
|
||||
@@ -0,0 +1,272 @@
|
||||
"""
|
||||
Tests for micromate/setup_block.py — the Micromate setup block (SUB 0x1A) decoder.
|
||||
|
||||
Every fixture is a real read off a unit, taken with scratch/mm_config_diff.py
|
||||
while an operator changed settings on the unit's own keypad, 2026-10-17/19.
|
||||
**Expected values are what the operator read off the unit's screen**, recorded in
|
||||
docs/micromate_protocol_reference.md — never values computed by this decoder.
|
||||
A test whose expectation came from the code under test passes whatever the code
|
||||
does.
|
||||
|
||||
Fixtures are 2,103-byte `0x1A` response data: an 11-byte prefix, then the
|
||||
2,092-byte content the decoder reads. `um12947_2026-09-24.bin` is a second unit
|
||||
on the other firmware line, cut from Thor's 9-24 "send TEST1" capture.
|
||||
"""
|
||||
|
||||
from __future__ import annotations
|
||||
|
||||
import os
|
||||
import sys
|
||||
from pathlib import Path
|
||||
|
||||
import pytest
|
||||
|
||||
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||||
|
||||
from micromate.protocol import ProtocolError # noqa: E402
|
||||
from micromate.setup_block import SetupChecksumError, crc_ok, decode_setup # noqa: E402
|
||||
|
||||
FIXTURES = Path(__file__).parent / "fixtures" / "micromate-setup"
|
||||
ALL_FIXTURES = sorted(FIXTURES.glob("*.bin"))
|
||||
|
||||
# Small real blocks for the generic checksum rule (content only, prefix stripped).
|
||||
# 0x08 preferences, Imperial and Metric -- UM20147, 2026-10-19 17:07 / 17:14.
|
||||
PREFS_IMPERIAL = bytes.fromhex(
|
||||
"00580900000000000000000000000000000000000000000000000000000000000000000000"
|
||||
"000000000100010001000100000000000000010001000000000000000000000000000000"
|
||||
"000002000000000000000200000000b42f"
|
||||
)
|
||||
PREFS_METRIC = bytes.fromhex(
|
||||
"00580900000000000000000000000000000000000000000000000000000000010000000000"
|
||||
"000000000100010001000100000000000000010001000000000000000000000000000000"
|
||||
"000002000000000000000200000000911a"
|
||||
)
|
||||
# 0x2E, same session.
|
||||
BLOCK_2E = bytes.fromhex("001ad50000010000000000000000000000000000000000000000141a")
|
||||
|
||||
|
||||
def content_of(name: str) -> bytes:
|
||||
return (FIXTURES / f"{name}.bin").read_bytes()[11:]
|
||||
|
||||
|
||||
# ── The checksum rule ─────────────────────────────────────────────────────────
|
||||
|
||||
def test_fixtures_are_present():
|
||||
"""15 fixtures; a missing directory would otherwise make the parametrised
|
||||
tests below collect nothing and pass vacuously."""
|
||||
assert len(ALL_FIXTURES) == 15
|
||||
|
||||
|
||||
@pytest.mark.parametrize("path", ALL_FIXTURES, ids=lambda p: p.stem)
|
||||
def test_every_real_setup_read_passes_its_checksum(path):
|
||||
assert crc_ok(path.read_bytes()[11:])
|
||||
|
||||
|
||||
@pytest.mark.parametrize(
|
||||
"block", [PREFS_IMPERIAL, PREFS_METRIC, BLOCK_2E], ids=["0x08-imperial", "0x08-metric", "0x2E"]
|
||||
)
|
||||
def test_the_rule_is_the_blocks_own_length_not_the_setup_size(block):
|
||||
"""One rule covers three blocks: N = content[0:2], CRC over [0:N-2] stored at
|
||||
[N:N+2]. An implementation hard-wired to the setup block's 2088 fails here."""
|
||||
assert crc_ok(block)
|
||||
|
||||
|
||||
@pytest.mark.parametrize("offset", [5, 144, 1738, 2087], ids=["mode", "note", "trigger", "last-covered"])
|
||||
def test_one_changed_byte_fails_the_checksum(offset):
|
||||
c = bytearray(content_of("um20147_baseline"))
|
||||
c[offset] ^= 0x01
|
||||
assert not crc_ok(bytes(c))
|
||||
|
||||
|
||||
def test_a_changed_trailer_fails_the_checksum():
|
||||
c = bytearray(content_of("um20147_baseline"))
|
||||
c[2091] ^= 0x01
|
||||
assert not crc_ok(bytes(c))
|
||||
|
||||
|
||||
@pytest.mark.parametrize("n", [0, 1, 2, 100, 2091], ids=lambda n: f"{n}B")
|
||||
def test_a_block_too_short_for_its_own_length_fails(n):
|
||||
"""A truncated read must read as bad, never raise IndexError and never pass."""
|
||||
assert not crc_ok(content_of("um20147_baseline")[:n])
|
||||
|
||||
|
||||
# ── Fields: every value below is what the operator read off the screen ────────
|
||||
|
||||
@pytest.mark.parametrize(
|
||||
"name, mode_code, mode_name",
|
||||
[
|
||||
("um20147_waveform", 0x01, "Waveform"),
|
||||
("um20147_waveform_manual", 0x02, "Waveform Manual"),
|
||||
("um20147_histogram_300s", 0x03, "Histogram"),
|
||||
("um20147_baseline", 0x04, "Histogram Combo"),
|
||||
],
|
||||
)
|
||||
def test_record_mode(name, mode_code, mode_name):
|
||||
"""Same codes as Series III, one byte later than the S3 analogy put them.
|
||||
The keypad menu order is 03 04 01 02, so an off-by-one enum reads wrong here."""
|
||||
s = decode_setup(content_of(name))
|
||||
assert s.record_mode == mode_code
|
||||
assert s.record_mode_name == mode_name
|
||||
|
||||
|
||||
@pytest.mark.parametrize(
|
||||
"name, rate",
|
||||
[("um20147_baseline", 1024), ("um20147_waveform_manual", 2048), ("um20147_4096sps", 4096)],
|
||||
)
|
||||
def test_sample_rate(name, rate):
|
||||
"""4096 puts a literal 0x10 (DLE) at content[6] -- the case that shifted
|
||||
every later field by one byte on Series III."""
|
||||
assert decode_setup(content_of(name)).sample_rate == rate
|
||||
|
||||
|
||||
@pytest.mark.parametrize("name, seconds", [("um20147_baseline", 2), ("um20147_histogram_300s", 300)])
|
||||
def test_histogram_interval(name, seconds):
|
||||
"""300 = 01 2c: the high byte is what proves the field is two bytes wide."""
|
||||
assert decode_setup(content_of(name)).histogram_interval_s == seconds
|
||||
|
||||
|
||||
@pytest.mark.parametrize("name, seconds", [("um20147_baseline", 1.0), ("um20147_pretrig025_auto", 0.25)])
|
||||
def test_pretrigger_is_reported_positive(name, seconds):
|
||||
"""Stored as NEGATIVE seconds (-1.0 / -0.25); the screen shows 1.0 / 0.25."""
|
||||
assert decode_setup(content_of(name)).pretrigger_s == seconds
|
||||
|
||||
|
||||
@pytest.mark.parametrize(
|
||||
"name, auto, record_time, auto_stop",
|
||||
[("um20147_baseline", False, 10.0, 3), ("um20147_pretrig025_auto", True, 11.0, 1)],
|
||||
)
|
||||
def test_record_time_window(name, auto, record_time, auto_stop):
|
||||
s = decode_setup(content_of(name))
|
||||
assert s.auto_record_stop is auto
|
||||
assert s.record_time_s == record_time
|
||||
assert s.auto_stop_after_s == auto_stop
|
||||
|
||||
|
||||
@pytest.mark.parametrize(
|
||||
"name, geo_on, mic_on, trig_geo, trig_mic",
|
||||
[
|
||||
("um20147_baseline", True, True, True, True),
|
||||
("um20147_geo_only", True, False, True, False),
|
||||
("um20147_mic_only", False, True, False, True),
|
||||
("um20147_geo_trigger_off", True, True, False, True),
|
||||
],
|
||||
)
|
||||
def test_active_sensors_and_trigger_sources_are_separate_masks(name, geo_on, mic_on, trig_geo, trig_mic):
|
||||
"""content[25] is which sensors are on, content[29] which may trigger.
|
||||
geo_trigger_off has both sensors on but only the mic triggering -- a decoder
|
||||
reading both from one byte gets that fixture wrong."""
|
||||
s = decode_setup(content_of(name))
|
||||
assert (s.geophones_active, s.mic_active) == (geo_on, mic_on)
|
||||
assert (s.trigger_on_geophones, s.trigger_on_mic) == (trig_geo, trig_mic)
|
||||
|
||||
|
||||
@pytest.mark.parametrize(
|
||||
"name, level",
|
||||
[("um20147_baseline", 0.5), ("um20147_waveform_manual", 0.6), ("um12947_2026-09-24", 0.3)],
|
||||
)
|
||||
def test_geophone_trigger_level_per_channel(name, level):
|
||||
s = decode_setup(content_of(name))
|
||||
assert s.geo_trigger_ips == pytest.approx((level, level, level), abs=1e-6)
|
||||
|
||||
|
||||
@pytest.mark.parametrize("name, db", [("um20147_baseline", 131.0), ("um20147_mic_140db", 140.0)])
|
||||
def test_linear_mic_trigger_is_psi_and_reads_back_as_the_screens_db(name, db):
|
||||
s = decode_setup(content_of(name))
|
||||
assert s.mic_type == "linear"
|
||||
assert s.mic_trigger_psi is not None
|
||||
assert s.mic_trigger_db == pytest.approx(db, abs=0.01)
|
||||
|
||||
|
||||
def test_the_mic_comes_from_block_4_not_from_the_stored_setups():
|
||||
"""Block 4 is the ACTIVE mic; blocks 5/6 are stored linear/SLM settings.
|
||||
With a sound-level mic selected, block 5 still holds a linear mic -- read it
|
||||
and the decoder reports a mic that is not plugged in."""
|
||||
s = decode_setup(content_of("um20147_sound_level_mic"))
|
||||
assert s.mic_type == "sound_level"
|
||||
assert s.mic_trigger_psi is None # its unit is not measured; not exposed
|
||||
assert s.mic_trigger_db is None
|
||||
|
||||
|
||||
@pytest.mark.parametrize(
|
||||
"name, enabled, number",
|
||||
[
|
||||
("um20147_baseline", False, 0),
|
||||
("um20147_job_1234", True, 1234),
|
||||
("um20147_scaled_distance", False, 1234), # switched off, number kept
|
||||
],
|
||||
)
|
||||
def test_job_number(name, enabled, number):
|
||||
s = decode_setup(content_of(name))
|
||||
assert s.job_number_enabled is enabled
|
||||
assert s.job_number == number
|
||||
|
||||
|
||||
def test_scaled_distance_uses_the_units_own_conversion_constants():
|
||||
"""Entered as 123 ft and 45 lb; the screen then showed scaled distance 18.34.
|
||||
Stored as metres and kg via ft / 3.2808 and lb / 2.21 -- converting back with
|
||||
the textbook 2.20462 shows 44.89 lb, not what the operator typed."""
|
||||
s = decode_setup(content_of("um20147_scaled_distance"))
|
||||
assert s.scaled_distance_enabled is True
|
||||
assert s.distance_ft == pytest.approx(123.0, abs=1e-3)
|
||||
assert s.charge_weight_lb == pytest.approx(45.0, abs=1e-3)
|
||||
assert s.scaled_distance == pytest.approx(18.34, abs=0.005)
|
||||
|
||||
|
||||
def test_scaled_distance_off_with_no_charge_weight():
|
||||
s = decode_setup(content_of("um20147_baseline"))
|
||||
assert s.scaled_distance_enabled is False
|
||||
assert s.scaled_distance is None # no charge weight: nothing to divide by
|
||||
|
||||
|
||||
def test_notes_are_label_value_pairs():
|
||||
s = decode_setup(content_of("um20147_location_bench01"))
|
||||
assert list(s.notes) == ["Location", "Client", "Company", "General Notes"]
|
||||
assert s.notes["Location"] == "BENCH01"
|
||||
|
||||
|
||||
def test_a_second_unit_on_the_other_firmware_line():
|
||||
"""UM12947 (11.0CB), cut from Thor's 9-24 capture: a different unit, firmware
|
||||
and setup. Strings are this job's notes as the read returned them."""
|
||||
s = decode_setup(content_of("um12947_2026-09-24"))
|
||||
assert s.name == "Univ of Pitt-1st Yr. Housing-Loc1 Ruskin.mmb"
|
||||
assert s.notes == {
|
||||
"Location": "Univ of Pitt-1st Yr Housing-Loc1 Ruskin",
|
||||
"Client": "PJ Dick Inc.",
|
||||
"Company": "Terra-Mechanics, Inc. - Harrison",
|
||||
"General Notes": "Loc#1-Univ of Pitt. - Ruskin Hall",
|
||||
}
|
||||
|
||||
|
||||
def test_raw_is_the_content():
|
||||
c = content_of("um20147_baseline")
|
||||
assert decode_setup(c).raw == c
|
||||
|
||||
|
||||
# ── Errors ────────────────────────────────────────────────────────────────────
|
||||
|
||||
def test_a_corrupt_block_raises_rather_than_decoding_garbage():
|
||||
c = bytearray(content_of("um20147_baseline"))
|
||||
c[5] = 0x05 # a mode byte no keypad produces
|
||||
with pytest.raises(SetupChecksumError):
|
||||
decode_setup(bytes(c))
|
||||
|
||||
|
||||
def test_a_checksum_error_is_a_protocol_error():
|
||||
"""Callers already catching ProtocolError around a read keep working."""
|
||||
assert issubclass(SetupChecksumError, ProtocolError)
|
||||
|
||||
|
||||
def test_verify_false_decodes_a_corrupt_block_anyway():
|
||||
"""For diagnosis: see what a bad read contained instead of only that it was bad."""
|
||||
c = bytearray(content_of("um20147_baseline"))
|
||||
c[5] = 0x05
|
||||
s = decode_setup(bytes(c), verify=False)
|
||||
assert s.record_mode_name == "unknown (0x05)"
|
||||
|
||||
|
||||
@pytest.mark.parametrize("verify", [True, False])
|
||||
def test_a_short_block_raises_even_without_verify(verify):
|
||||
"""verify=False skips the checksum, never the bounds -- a short read would
|
||||
otherwise decode as zeros, or raise an IndexError from deep in a slice."""
|
||||
with pytest.raises(ProtocolError, match="2092"):
|
||||
decode_setup(content_of("um20147_baseline")[:1900], verify=verify)
|
||||
Reference in new issue