Group B of the file-only decode, measured on DL2 2026-11-03:
- Frequency = (sample rate / 2) / half-period: 527,915 / 527,915 cells
at 1024 sps and 1,725 / 1,725 at 2048. #50: half_period_to_hz took a
fixed 512 and halved every 2048-sps frequency; it now takes the rate
(default 1024). Blastware prints 'N/A' for a half-period of 0, '>100'
('>200' at 2048) at 5 samples or fewer, '<1.0' below 1 Hz.
- Each interval's vector sum, sqrt(PVS^2) at the event's range:
771,354 / 771,354.
- Interval size: uint16 seconds at k - 40 (Series IV [8:10]).
- Stop: the footer's (2,995 / 2,999 sampled; 4 print a second earlier).
Event gains histogram_interval_sec, interval_half_periods, interval_pvs
and stop_time; the .h5 gains /intervals/half_period/<ch>,
/intervals/pvs_ips and a histogram_interval_sec attr. The decoder walks
a histogram once (histogram_codec.channels_from_records) and takes the
event's PVS from the same records. The checker compares each interval
column, number or Blastware's word; the test that pinned Tran Freq Hz
as blank now pins the match.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
K441LA17.IN0W's report says Units 'in/s and psi(L)' yet prints
MicTriggerLevel '125.0 dB(L)'. The value states its own unit, so that
is the one compared; the report's Units is the fallback. It was the
only MicTriggerLevel mismatch in DL2 (SFM's 0.005158 psi is 125.0 dB).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Group A of the file-only decode, every field matched against every DL2
report (2026-11-03):
- Identity block before the setup name, what the live read gets from
SUB FE: serial k-202, firmware k-147, DSP version k-138, calibration
date k-132 + 'by' k-128, manufacturer k-94, model k-72, firmware
minor k-193. Event.device_info (DeviceInfo gains calibration_date /
calibrated_by). Serial, Version and Calibration 69,983 / 69,983.
- Battery: uint16 hundredths of a volt at k-190 (Event.battery_volts).
69,729 exact; the other 254 are Blastware rounding half up.
- Trigger source: the two bytes between the embedded event record's
lead and fe 80, a bitmask (0x01 Tran 0x02 Vert 0x04 Long 0x08 MicL
0x200 Manual): 6,493 / 6,493. Event.triggered_by.
- Trigger settings in Series IV's 0x1A layout: sources bitmask k-19,
stop mode k-31 (0 = Fixed), each channel's float32 level at
label+30 (geo in/s, mic psi), mic type code at MicL+4 (2 = Linear
Weighting). Geo level 6,447 / 6,447, mic 4,403 / 4,403; Blastware
prints a level when its channel is a trigger source and the event
was not Manual. The mic level's dB uses 6895 Pa/psi (4,272 / 4,272
against 4,271 at 6894.757).
- .h5 attrs for all of them (additive).
- Checker: SFM's side reports the ten fields; the mic trigger level
follows the report's dB/psi. Carve-out
units-is-a-display-preference: dB or psi is Blastware's PC setting
when it wrote the report -- DL2's reports switch fleet-wide in 61
clean runs by write time, and no byte of the file separates them.
Two tests that pinned BatteryLevel / Calibration as blank now pin the
match.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Three causes behind the histograms the checker found decoding wrongly:
1. The file decoder tried the waveform codec first, whatever the record
type. It accepted BE9440 / BE9557 / BE17354's 2018 5 s histograms and
returned ~5x too many 'samples' (K440HDXX.XH0H: SFM 44,504, Blastware
6,976). The codec now follows STRT[18] (0x46 / 0x0A on 70,041 /
70,041 DL2 files); only an unknown type falls back to trial order, and a
chosen codec that fails is a decode problem rather than a silent switch.
2. The sub-minute layout check required each record's 'zero word' to be
0000. It is the high word of the interval's PVS squared, non-zero above
1.28 in/s, so a one-block histogram with a loud interval was not
recognised (T193KR5M.X90H, K440HA3C.JM0H, R352HFZ7.530H decoded to
nothing). The check is now the measured relation peak <= PVS <=
sqrt(3) * peak, which holds on 34,502,955 / 34,502,955 DL2 sub-minute
intervals. The no-terminal-tail trim uses the same test. Two test
builders wrote PVS bytes no real record has (one still in the retracted
little-endian layout); they now write peak^2 in the measured layout, and
the retraction test keeps a legacy builder of its own.
3. Checker carve-out interval-count-is-duration: Blastware's Number of
Intervals is (stop - start) / interval from the footer times, and its
own interval table lists one block fewer when the unit never wrote the
last minute. SFM matches the table (T193KSWP.FF0H: 2,880 vs 2,850).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The setup block has Series IV's 0x1A layout here too: report flags at
k - 9 (bit 0x02 = job number shown) and the number, uint16 BE, at k - 8,
kept while switched off. The flag matches Blastware's JobNumber on
2,997 / 2,997 DL2 events that print one and 66,986 / 66,986 that don't.
Every printed value is 1 and matches; hidden ones hold real numbers
(802, 1012, 1013, 622), so the value is only proven for 1.
- ProjectInfo.job_number_enabled / job_number, named as in
micromate.setup_block.
- write_event_hdf5 stores both as .h5 attrs when read (additive).
- The checker reports the number only when shown, and scores a number
only SFM shows as a mismatch. The old test that pinned JobNumber as
sfm_blank now checks only the ZC cases it also covered.
Not carried into the DB, the API or the PDF report yet (needs a column).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
In the setup's channel blocks, the byte 29 after each geophone label is
the range: 0x00 Normal (10 in/s), 0x01 Sensitive (1.25 in/s). It matches
Blastware's GeoRange on 70,042 / 70,042 DL2 events, all three channels
agreeing on every one (35 Sensitive). SFM's live 1A has the same byte
at label+33. SFM assumed Normal, so every Sensitive event's peaks,
vector sum and .h5 samples read 8x high.
- Event.geo_range (0 / 1, None when not read -- channels disagreeing,
an unknown value or a missing block -- with a decode_problems entry).
- decode_blastware_bytes scales peaks and the histogram vector sum by it.
- event_hdf5.write_event_hdf5: geo_range defaults to None = the event's
own, else Normal; an explicit argument still wins.
- waveform_store.save_imported_bw and scripts/backfill_sidecars.py stop
forcing 'normal', so imports and the backfill store the file's range.
The waveform_store line was agreed with the parity session, which owns
that file; its own branch keeps a geo_range parameter, defaulting to
None at its next dev merge.
- The checker's SFM side converts at the event's range and reports
GeoRange; tests that pinned the old 8x gap now pin the fix, and the
saturation carve-out is still tested against an 8x value.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
SFM converted mic counts to psi with a '~0.5 psi full-scale' guess
(0.0125 / 32768 psi per count). Measured against 1,729,253 DL2
histogram intervals' 'MicL Peak' columns: one count is exactly 0.25 Pa.
count x 0.25 Pa matches Blastware's psi(L) on every interval, and
20 log10(count x 0.25 Pa / 20 uPa) its dB(L) on all but 17 exact
half-way cases.
- event_file_io: _MIC_FS_PSI -> _MIC_PSI_PER_COUNT = 0.25 / 6894.757
(3.626e-5 psi per count, was 3.81e-7). The event's mic peak in psi,
and with it the .h5 mic trace (event_hdf5 back-solves its scale from
that peak), come right on events with no report.
- waveform_codec.mic_count_to_db: the offset is 20 log10(0.25 / 20e-6)
= 81.938, not 81.94 -- the old value missed 49 of those intervals at a
rounding edge (count 119 printed 123.4, 81.94 gave 123.451).
The decoded count was always right: count 16 on K441LTON.900 is
Blastware's 106.0 dB.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
STRT[18] is the record-type byte: 0x46 on every one of DL2's 6,577
waveform files, 0x0A on every one of its 63,535 histograms. The decoder
read the type from the filename's last letter, so an event with no
Blastware name -- SFM's own downloads, the call-in path -- or a manual
download ('.QZ0') came out 'Waveform' whatever it was.
The filename is now a cross-check that logs a disagreement; the bytes
win. An unknown byte (Manual / Event / Combo never occur in DL2) is
record_type None with a decode_problems entry, not a guess.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
- A matching event that now fails outright is a regression: compare_runs
walks the previous run's matching rows, so a check that collapses to
one error row no longer hides every field it used to match. Counts
moved are taken over the events both runs checked.
- The default baseline is the newest completed run (run.json written) of
the same scope; a 2,000-event sample is no baseline for a full run.
changes.md names the previous run's scope.
- The PVS saturation carve-out now needs Blastware's OORANGE, a channel
Blastware clamped at SFM's ceiling, and SFM's sum within three channels
at the ceiling -- an unclipped Sensitive-range channel read 8x can no
longer let an 8x sum through.
- 'Fields fully matching' needs a match: an always-empty element proves
nothing. Events without a report are a line of their own.
- CLAUDE.md: histogram PVS described correctly; 35 sub-minute histograms
plus 2 one-minute no-mic ones, not '~37 sub-minute'.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
A mismatch becomes 'accepted' only through a written carve-out whose
evidence does not rest on SFM's output. Saturation: Blastware clamps a
clipped channel to the range maximum and prints OORANGE, while the file
holds counts past full scale. SFM's value must sit at the ceiling
(r - 0.0006 .. r * 1.01), so a Sensitive-range event read 8x high on
SFM's Normal assumption stays a mismatch; a vector sum is accepted when
a clipped channel under it is at the ceiling. series_pairs() is now the
one place waveform rows and interval columns are paired.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Every field the report carries (bar its format version and Blastware's
file name), the notes in order, the job number, the channel list, every
waveform sample and every histogram interval column. Numbers match at
Blastware's printed precision, halves rounding away from zero; N/A and
empty text are no_reference; >100 needs SFM's above-range flag; OORANGE
is a mismatch unless a carve-out says otherwise. Waveform rows pair
cells with the channels still running, so channels that end early
(T438HGTZ.B30W) match, and any row-length disagreement is counted.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
decode_blastware_bytes with no filename and no report: the values SFM
produces today in Blastware's field names, its notes, channels and raw
counts, with its Normal-range assumption kept.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9