Bench, 2026-10-25, Brian's go per send: 0x96 acked in 464 ms and read back
monitoring at the first 2 s poll (during the sensor check); 0x97 acked in
116 ms, then 0x49 read a new value 0x01 for ~18 s (inferred: the unit's
call-home attempts after a stop) before idle; two stops to an idle unit acked
in 10 ms and changed nothing. Retracts "no command has ever been originated"
in place in CLAUDE.md and the reference's untested list; answers the spec's
stop-while-stopped question.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- New section "Left open by the phase 1b review (2026-10-21)", after the
1a one: twelve one-line items, each naming the phase it matters to
(retry re-running a whole download, last_used after a kept-line error,
verified:null's two meanings, mic naming + the S4 0x0C mic denormal,
500 detail text, the serial as a directory name, no server-level ring
test, S3 stored record_type, a fresh S4 download's gaps, orphan files,
same-second collisions, 423 Retry-After).
- The 1b bullets now give the owed MiniMate bench check's scope: a 3+
event list (1F(browse) after 1E(arm) without 1F(arm)), a non-first
event, a histogram (capture its 0C), an event past 64 KB (the named
502), a stale id (no 5A), and a dropped reply via mm_link-style fault
injection.
- The 1b "Download" bullet's "refreshes the row" is retracted in place:
the final review changed it to "returns the row, writes nothing".
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Ten tasks, test-first: the is_open fix, two client reads, core types, the
per-unit lock, both adapters, Series-4 sessions with ring safety,
DeviceAccess with the reaper and the contract tests, the endpoints, and a
read-only bench check on UM20147.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Nothing breaks between phases: the shared models apply when a request names
the unit by serial, and the legacy Series-3 path stays as it is until the
webapp (1c) and watch_unit.sh move over.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brian's principle: talking to a Series 3 or a Series 4 unit is identical for
the user; only the serial prefix and each model's settings differ, and the
adapters absorb the rest.
Five places the draft broke it, now fixed: units are named the same way
(serial + address, no-serial kept only as a legacy Series-3 path); one set
of series-neutral response models with series-only fields under `detail`;
one opaque event_id for both; a uniform 501 "not supported for Series N
yet" instead of missing routes; and the webapp brought into scope with the
same screens for both. Adds an adapter table, contract tests that keep the
two adapters honest, and notes that existing Series-3 response shapes move
to the shared models (the webapp updates with them; Terra-View does not
call /device/*).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Parity of jobs with Series 3 for regular comms and settings (identify,
status, settings, events, download, monitor log, start/stop, call-home
enable/disable, setup push); Series-4 emergency tools deferred. A single
device-access layer: series from the serial prefix, identity confirmed
before any write, a per-unit lock, an 0xA2 opcode guard, read-back
verification of every change, distinct error codes, and an audit table.
Series-4 sessions ("stay on the line") now; Series-3 sessions after a bench
test of MiniMate hangup/DCD behaviour.
Includes the fix list found in the 2026-10-19 inventory, the to-be-added
table, and the RX55 container idea as a parking-lot item.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The wedged_unit_recovery runbook covered exactly one failure mode. BE12599
turned out to be a second one wearing the same symptoms, and the existing
procedure did not work on it.
Adds a "TWO failure modes" table up front so the next incident branches
correctly, and a full second-incident section covering what the ALEOS serial
debug log revealed: the device repeating a 29-byte AT modem-init string
(ATQ1/ATE0/ATS0=2, no ATD) every 75 s, never getting an OK because the modem
is in TCP data mode, and therefore never entering S3 mode at all. Inbound
cannot win against that, no matter how well framed.
Also records the two red herrings, since together they cost ~90 minutes:
the RV50 trusted-IP whitelist drops non-listed sources silently (presents as
a connect timeout, and Brian's dynamic dev IP had rotated off the list), and
sfm/server.py returns 502 for BOTH "Protocol error:" and "Connection error:",
so a 502 was misread as "TCP connected, device mute" and a theory built on it.
And the gotchas worth never re-deriving: slow_drip's send_error=null plus a
full duration is not success (only bytes_received > 0 is); stopping monitoring
removes the call-in trigger, so it costs you the channel; --events-only skips
the device-info step, so the serial is never read and ach_state keys on
peer:ephemeral_port, silently breaking dedup and re-downloading the same event
every session.
The plan doc captures the tool Brian wants built out of this — a rescue
listener with a real lifecycle and, critically, a confirmation gate before
shutdown, because leaving the modem's Destination pointed at a dead listener
is worse than never having started. Open questions are listed rather than
guessed at.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Qcu9ByJfuKBQxmrWb8rSrN
7-task TDD plan: shape DSP module (crest factor + points-near-peak), shape_*
columns + auto-migrate, insert_events persistence, ingest population in the
save paths, backfill script, /db/events exposure + v0.24.0 bump. Phase B
(terra-view scoring/UI/review) gets its own plan once this feed is live.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf