A Micromate event read without Thor's report (SFM's own downloads) came out
with sample rate, pre-trigger and record time 0, empty notes, and a
1970-01-01 time; every Micromate .h5, report or not, stored pre-trigger 0.
- The settings were found by the bytes be 80 00 00 00 00 -- a -0.25 s
pre-trigger and Fixed stop mode, not a marker -- so any other pre-trigger
left them unread. The event's settings record is now found by its own
signature 00 2a 04 00 00 (fields at the live 0x1A block's head offsets).
- The event time is read at settings record + 0x34, not two fixed offsets
that miss a header shape.
- The four notes are read at 0x23c ([label 22][value 42] x 4).
- IdfEvent.to_minimateplus_event sets pretrig_samples.
- save_imported_idf fills the pre-trigger and notes from the file when the
report lacks them.
Measured against Thor's own reports on 2,027 corpus files: sample rate and
notes 2,027 / 2,027; record time and pre-trigger 291 / 291 waveforms; event
time = filename on 2,384 / 2,384. The issues' 20 UM12947 bench files now
store 4096 S/s, 4096 pre-trigger samples (1.0 s), 3 s and their notes.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R9LdWawLzUxwewZGA1