Commit Graph
5 Commits
Author SHA1 Message Date
serversdownandClaude Opus 5.5 9082236c5e fix(webapp): the final review's three page findings
- The arrow keys reached the legacy per-index waveform route in serial mode,
  even with no list loaded (an unlocked MiniMate chain walk + 5A on the same
  modem session).  perIndexLive() is now the one rule for the per-index
  buttons, the chips and the keyboard: live only for a list loaded without a
  serial that has events.
- A failed reconnect left the previous unit's confirmation live (badge,
  Diagnostics incl. the unguarded blind/slow-drip stops, call-home read).
  connectUnit() now drops it before it identifies; only this answer confirms.
- Unit strings reached innerHTML: the Device tab's cards (active_setup, new in
  1c) and its compliance/project tables now render as text, and Diagnostics'
  error spans go through escapeHtml().
- CLAUDE.md: the ring-path Runs A/B are a merge gate (the spec's prerequisite
  to a webapp sending serial), not only a use-time one.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 12:16:49 -04:00
serversdownandClaude Opus 5.5 a709d2388d feat(webapp): config and call-home writes wait for phases 4-5; Diagnostics only for a confirmed Series-3 unit
- Config, with a serial: Read shows the unit's shared UnitSettings (setup,
  record mode, sample rate, record time, histogram interval, geo trigger,
  notes; — for null) in place of the write form.  settingsRows() is in the
  device-routing block, Node-tested; the rows are rendered as text, since
  setup names and notes come from the unit.
- Write stays off for both series (and without a serial), tooltip
  "Coming in phase 5 (#46)"; Call Home write likewise, "Coming in phase 4".
- Call Home read follows controlsFor().callHomeRead; for a confirmed Series 4
  the tab says "Not yet available for Series 4".
- Diagnostics: every button follows controlsFor().diagnostics (Task 3), and a
  refresh for anything but a confirmed Series-3 unit sends nothing and says
  why.  Its requests carry the typed serial, so the server guard checks it.
- Without a serial the legacy reads are unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:59:11 -04:00
serversdownandClaude Opus 5.5 9aae3b09de feat(webapp): list and download events by serial, for both series
- Load events with a serial lists the shared EventRef shape as a table: index,
  time, type, PVS and the three peaks (or —), each row with its own Download.
- Download POSTs the row's event_id; SFM checks and stores it.  The status bar
  says what was stored (or that it already was), and the stored event opens
  in the viewer.  A refusal shows the server's detail verbatim.
- eventView() (device-routing block, Node-tested) reads both event shapes for
  the table, the chips and the peaks bar.
- A list loaded without a serial keeps the chips and the per-index Load /
  Save / Download buttons, unchanged; for a serial-loaded list those buttons
  are off with a tooltip pointing at the rows.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:54:43 -04:00
serversdownandClaude Opus 5.5 44d6e754bd feat(webapp): name a unit by serial; series badge from the unit's own answer; Hang up for Series 4
- A Serial field beside host/port.  With one, the Live tabs use the serial-based
  endpoints (both series); without, every read behaves as before.
- The series badge, Hang up (Series 4), Diagnostics (Series 3), call-home read and
  the disabled config/call-home writes all follow applyControls() <- controlsFor()
  on the unit's own /device/info answer; editing the serial, host or port drops
  the confirmation.  Erase additionally needs a confirmed Series 3.
- Every /device/ request goes through deviceRequest/deviceFetch <- deviceUrl
  (a static test enforces it); the legacy per-event routes joined deviceUrl
  (event_waveform / event_file, index in the path).
- The status panel and Device tab read both shapes (shared and legacy).
- In serial mode the connect skips the legacy storage_range read (one connection
  fewer; a Micromate has no such route).  Start/stop without a serial behave as
  before; with one, only for a confirmed series.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:50:24 -04:00
serversdownandClaude Opus 5.5 e3717706f8 feat(webapp): the device-routing rules as pure functions, tested through Node
One block of sfm_webapp.html (/* <device-routing> */) holds every rule that
decides where a /device/ request goes or whether a series-specific control is
live: seriesFromSerial, unitQuery, deviceUrl, confirmedSeries, controlsFor,
changeSummary, downloadSummary.  No DOM, no fetch, so the tests run it in Node.

The safety rules it pins: a control follows the unit's own /device/info answer,
never a typed serial alone, and stops counting when the serial is edited;
Diagnostics only for a confirmed Series 3, Hang up only for Series 4; config and
call-home writes off for both series until phases 4-5.  Also a test that the
page's inline scripts parse together (shared global scope).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:46:08 -04:00