Commit Graph
16 Commits
Author SHA1 Message Date
serversdownandClaude Opus 5.5 c6f7b5c031 docs(spec): the ring cool-down is test-first -- bench procedure for the ring path and retries
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 00:20:08 -04:00
serversdownandClaude Opus 5.5 75b7694983 docs(spec): phase-3 write preconditions and the measured Series-3 verdict
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:48:52 -04:00
serversdownandClaude Opus 5.5 2a6acae259 docs(plan): Series-4 write path phase 2 -- encoder, opcode gate, write plans, dry run
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 00:14:30 -04:00
serversdownandClaude Opus 5.5 7a6c74266b docs: phase 1b re-review residuals -- bench scope gains the already-stored check, parked items corrected
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:59:25 -04:00
serversdownandClaude Opus 5.5 67a0fece34 docs(spec): park two more phase 1b items -- a lost 0C in a list, the walk retry
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:45:04 -04:00
serversdownandClaude Opus 5.5 a5ebe8d4b1 docs(spec): park the phase 1b review's open items; scope the owed MiniMate bench check
- New section "Left open by the phase 1b review (2026-10-21)", after the
  1a one: twelve one-line items, each naming the phase it matters to
  (retry re-running a whole download, last_used after a kept-line error,
  verified:null's two meanings, mic naming + the S4 0x0C mic denormal,
  500 detail text, the serial as a directory name, no server-level ring
  test, S3 stored record_type, a fresh S4 download's gaps, orphan files,
  same-second collisions, 423 Retry-After).
- The 1b bullets now give the owed MiniMate bench check's scope: a 3+
  event list (1F(browse) after 1E(arm) without 1F(arm)), a non-first
  event, a histogram (capture its 0C), an event past 64 KB (the named
  502), a stale id (no 5A), and a dropped reply via mm_link-style fault
  injection.
- The 1b "Download" bullet's "refreshes the row" is retracted in place:
  the final review changed it to "returns the row, writes nothing".

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:42:24 -04:00
serversdownandClaude Opus 5.5 6b4161ddfb docs(spec): phase 1b decisions -- header-only MiniMate list, download stores, event_id
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:40:31 -04:00
serversdownandClaude Opus 5.5 89433c1fdb docs(spec): every phase lands on this branch; one merge to dev at the end
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 15:35:26 -04:00
serversdownandClaude Opus 5.5 e1af35e1d0 docs(spec): park the phase 1a review's minor findings in the spec
They were recorded only in the plan's scratch ledger, which is deleted
when the plan finishes.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:59:42 -04:00
serversdownandClaude Opus 5.5 080e8f4704 docs: serial parameter, settings/hangup endpoints, single-worker rule, cool-down prerequisite for 1c
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:33 -04:00
serversdownandClaude Opus 5.5 bbc6fe2a61 docs(spec): serial-less requests keep today's shapes; phase 1 splits into 1a/1b/1c
Nothing breaks between phases: the shared models apply when a request names
the unit by serial, and the legacy Series-3 path stays as it is until the
webapp (1c) and watch_unit.sh move over.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 19:03:03 -04:00
serversdownandClaude Opus 5.5 68cad4e2ab docs(spec): monitor logs are their own piece of work -- row 6 moves to the parking lot
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:54:24 -04:00
serversdownandClaude Opus 5.5 435c1978a0 docs(spec): park setup files and schedules as one open question
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:42:41 -04:00
serversdownandClaude Opus 5.5 90171996d6 docs(spec): say plainly what 'no PC-side setup library' means
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:38:56 -04:00
serversdownandClaude Opus 5.5 3215c17e37 docs(spec): one user experience for both series -- the guiding principle, applied
Brian's principle: talking to a Series 3 or a Series 4 unit is identical for
the user; only the serial prefix and each model's settings differ, and the
adapters absorb the rest.

Five places the draft broke it, now fixed: units are named the same way
(serial + address, no-serial kept only as a legacy Series-3 path); one set
of series-neutral response models with series-only fields under `detail`;
one opaque event_id for both; a uniform 501 "not supported for Series N
yet" instead of missing routes; and the webapp brought into scope with the
same screens for both.  Adds an adapter table, contract tests that keep the
two adapters honest, and notes that existing Series-3 response shapes move
to the shared models (the webapp updates with them; Terra-View does not
call /device/*).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:33:48 -04:00
serversdownandClaude Opus 5.5 1c6aa04687 docs(spec): SFM Series-4 parity and a device safety layer -- design for review
Parity of jobs with Series 3 for regular comms and settings (identify,
status, settings, events, download, monitor log, start/stop, call-home
enable/disable, setup push); Series-4 emergency tools deferred.  A single
device-access layer: series from the serial prefix, identity confirmed
before any write, a per-unit lock, an 0xA2 opcode guard, read-back
verification of every change, distinct error codes, and an audit table.
Series-4 sessions ("stay on the line") now; Series-3 sessions after a bench
test of MiniMate hangup/DCD behaviour.

Includes the fix list found in the 2026-10-19 inventory, the to-be-added
table, and the RX55 container idea as a parking-lot item.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 17:41:00 -04:00